Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹31.4 L+₹4.9 L (18.6%)Rejected-Finance HN 2 PREETI NAGAR PHASE II FAIZULLAGANJ LUCKNOW UTTAR PRADESH 226020 | LUCKNOW | UTTAR PRADESH | 226020 | L2 | Rejected-Finance Over all rates are higher than L1. | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate category | |
| 4 | Rejected-Technical SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | - | Rejected-Technical Not enlisted in appropriate category | |
| 5 | Rejected-Technical 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | - | Rejected-Technical Not enlisted in appropriate category |
Tender Value
₹32.9 L
EMD Value
₹65,800
Closing Date
12 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Bareilly
CWE AF Bareilly
REPAIR REPLACEMENT OF HT NETWORK AND OTHER ALLIED WORK AT AIR FORCE STATION BKT
2021_MES_442945_1
81254/E8 Repair replacement of HT Network
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
BKT
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) BKT
₹65,800
Yes
29 Jun 2021
15 May 2021
14 Jun 2021
15 May 2021
12 Jun 2021
31 May 2021
15 May 2021 - 24 May 2021
60 days
Amount
Testing of 33/11 KV, 01 MVA step down transformer on site and generation of testing report and earth resistance test, O.T.I/ W.T.I , Buchholz circuit test serviciability and wiring from VCB panel to transformer , including following tests complete all as specified and as dorected : - a) Insulation Test (IR/ Megger Values ) b) Open Circuit/Ratio test. c) Short Circuit Test. d) Magnetic Balance Test. e) Magnetization current Test. f) BDV Value of T/F Oil.
Servicing of HT (33 KV ) panel (1 incoming 02 outgoing ) , detection of defective components, replacement of worn out parts and servicing/ cleaning of mechanical components, through authorized representative service centre of VCB manufacturer channel partner /OEM or UPPCL approved vendor for VCB repairing agency , Testing for smooth operation manual/ remote after caliberation of relay and resetting & generation of testing report by the primary injection set For 3x33 KV VCB for OC/EF ,parameter of relay setting ,complete all as specified and directed by Engr-in-Charge. Note: Worn out minor parts shall be deemed to be included in unit rate.
Servicing of HT panel (02 incoming 06 outgoing and buscoupler ) , detection of defective components, replacement of worn out parts and servicing/ cleaning of mechanical components, through authorized representative service centre of VCB manufacturer channel partner /OEM or VCB repairing agency, Testing for smooth operation manual/ remote after caliberation of relay and resetting & generation of testing report by the primary injection set For 6x11 KV VCB for OC/EF ,parameter of relay setting for healthy system , complete all as specified and directed by Engr-in-Charge. Note: Worn out minor parts shall be deemed to included in qupoted rate
M&L Transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement all as specified and as directed by Engr-in-Charge. (Oil should be supplied in sealed barrel of Power/Transol brand) Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.
Dehydration /Filteration of Transformer Oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS- 355, Breakdown voltage should not be less than 50 KV complete all as specified and directed.
Taking up U/S HT Cable of size 95sqmmx3.0 core complete all as specified and directed by Engr-In-Charge.
Supply, laying, jointing and testing of HT XLPE PVC insulated PVC sheathed armoured heavy duty electric cable with aluminium conductor for working voltage upto 11000 Volts (E) , graded of cross sectionsal area 95 sqmm 3 core , complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc and getting out cable cover and stacking for reuse/ credit , trimming sides and forming bottom surface complete all as specified and directed. Note :- Getting out of cable and deposit in store yard shall be measered and paid separately.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified.and directed.
Removing surplus excavated soil n exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for Sand cushioning/sand covering for underground cable protection complete 8 cm below the cable and 15 cm above the cable complete all as specified and directed. Note:- Punned thickness shall be measured.
Supplying and laying un-reinforced precast concrete cable cover class HV type 1 flat size 300mmX180mmX40mm complete all as specified and directed.
Relaying un-reinforced precast concrete cable cover class HV type 1 flat size 300mmX180mmX40mm complete all as specified and directed.
Supplying, installing, testing and commissioning in replacement of triple pole gang opearted air-break, triple pole off load switch with drop out use set with 12 insulator, mounted on channels steel vertical mounting type HT 11 KV , 50 Hz rating 200 Amps ,outdoor , mechanically operated, mounted on insulators and frame work with operating mechanism worked from ground level with adequate length of GI pipe 25 mm dia medium grade and locking arrangements including Godrej (Navtal) 65 mm pad locks with two keys, complete with fuse carriers and HT use elements 10 amp rating suitable or including necessary electric connections in repairs , complete all as speciied and as directed by Enge-in-Charge
M&L cable jointing kit for 11 KV (E) grade cable for indoor end termination heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 sqmm 3 core in repair including cutting of existing wornout termination kit , complete all as specified and directed.
M&L cable jointing kit for 11 KV (E) grade cable for out door end termination heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 sqmm 3 core in repair including cutting of existing wornout termination kit , complete all as specified and directed.
M&L cable jointing kit for 11 KV (E) grade cable for straight through heat shrink type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 sqmm 3 core in repair including cutting of existing wornout straight through joint , complete all as specified and directed.
M&L cable jointing kit for 33 KV (E) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for XLPE insulated armoured aluminium conductor cable of size 120 sqmm in repair including cutting of existing wornout termination kit , complete all as specified and directed.
M&L cable jointing kit for 33 KV (E) grade cable for out door end termination heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm in repair including cutting of existing wornout termination kit , complete all as specified and directed.
M&L cable jointing kit for 33 KV (E) grade cable for straight through heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm 3 core in repair including cutting of existing wornout straight through joint , complete all as specified and directed.
M&L for Painting of transformer after preparation of existing surface of transformer , remove oil stains, dust etc and applying two coat of hammertone by spray paint incl writing SM No/MES No , capacity of transformer of following capacity all as directed by Engr-in-Charge :-
(a) 25 KVA to 100 KVA
(b) 150 KVA to 315 KVA
M&L of Earthing complete with galvanized steel earth plate electrode 60 x60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to GI earth lead 32 x 6 mm dia by means of bolts nuts, check nut and washers of GI and GI tubing 40 mm bore, light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) typeC 1 pre cast RCC (1:2:4) type B1 cover slab 450 x 450 x 50 mm with one handle for lifting made out of 8 mm dia MS bar, wire mash, 20 mm bore GI tubing (light grade) for watering ,charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed Electrical plate no 3 of SSR Part-I comlete all as specified and directed. Note :- Taking out of earth lead from test terminal to Pit chamber of earthing and incuding demolition of pit cover and make good surfce of Ground deemed to be included in unit rate
Supply and fix pin type porcelain vitreous white brown insulator confirming to IS : 731 - 1971 & IS: 2486 Part _II - 1989 including one galvanized mild steel spindle two galvanized iron washers and one galvanized iron nut for 33 KV grade complete all as specified and directed.
Supply and fixing Battery 2 Volt 100 AH for battery Bank installed in 33 KV MRS for HT control Panel complete with termination clips complete all as specified and directecd.
Supply and fix disc type porcelain vitreous ball and socket type white brown double disc assembly insulator confirming to IS : 731 - 1971 & IS: 2486 Part - II - 1989 for tension with tension clamp for conductors working pressure 33 KV complete all as specified and directed.
Supply & fixing of Silica gel in granular form for transformer air breather complete all as specified & directed by Engr-In-Charge.
M&L for Painting of 33/11 KV Main Receiving Station switch yard including preparation of surface of Steel Structure , removal of dust etc and applying two coat of aluminium paint complete all as directed by Engr-in-Charge.
Detection of pin point fault in HT cable (burried in ground/under road/path up to depth of 1.5 m) by cable fault locating machine comprising impulse generator,acoustic fault locator and reflectometer (laptop based) complete all as specified and as directed by Engr-in-Charge. Notes- (i) Cable fault locating machine to be arranged at site with in 12 hrs after intimation (ii) Earth work will be measured seperatly. (iii) Cost of transpotation in unit rate is deemed to be included.
Taking out U/S LT Cable from trenches or in air of 50 -120sqmm x3.5 core size complete all as specified and directed.
Taking out U/S LT Cable from trenches or in air of 10sqmm x2.0 core size all as directed by Engineer in charge complete.
Laying only cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of sizes 120 Sqmm 3.5 core .complete all as specified and directed. (Note :- LT UG Cable will be issued by department under Sch B.)
Laying only cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of sizes 95 Sqmm 3.5 core complete all as specified and directed. (Note :- LT UG Cable will be issued by department under Sch B.)
Laying only cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of sizes 50 Sqmm 3.5 core complete all as specified and directed. (Note :- LT UG Cable will be issued by department under Sch B.)
Laying only cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of sizes 10 Sqmm 2 core complete all as specified and directed. (Note :- LT UG Cable will be issued by department under Sch B.)
Laying only retrieved bricks,from trenches for protection of underground cable complete all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete all as specified and directed.
S&F of 33KV 10 KA metal oxide (Gap less type ), heavy duty single pole self supporting station class ,class II insulation level 70KV incuding taking out old one complete all as specified and directed.
Disconnecting of HV / LV cable from transformer 1MVA 33/11KV at site , and loading and unloading of Transformer at both side MRS of GE AF BKT and repair work premises , hiring of crane and transportation charges to and from complete all as specified and directed.
Labour only for opening of top cover and allied parts of transformer, lifting of Core for repair , preheating charges for copper coils, assy of core coil assy including assy of copper coils, Tapping connections , insulation on Tap leads with insulation paper , Star , star connection by new EC grade copper on HV & LV side ., Baking charges for transformer job for each proper IR value in vacuum Chamber ( Auto Clave ) , refitting of HV / LV bushing and transformer accessories with top cover, M& L for painting of transformer tank having hot oil resistant paint inside complete all as specified and directed.
M&L for changing of Old / Burnt Copper coil by new EC grade copper coils with complete including insulation material of transformer cap 1 MVA complete all as specified and directed.
M& L connecting of HV / LV connection at site and testing of transformer including replacement of Silica Gel , connecting earth strip all as spd
Ajanta Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .