Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC B 148 2ND FLOOR B BLOCK NEAR MOTHER DIARY SECTOR 8 DWARKA NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹29.6 L+₹2.9 L (10.8%)Rejected-Finance | L2 | Rejected-Finance Quoted Higher than L1 | |
| 3 | Not Admitted-Fee | - | Not Admitted-Fee Fee not received |
Tender Value
₹30.8 L
EMD Value
₹61,631
Closing Date
4 Dec 2019, 5:00 pmClosed
AGM (Engg.Elect.), AAI, B.M.Airport, Ranchi
AAI, B.M.Airport, Ranchi
SITC of PBBs and AVDGS at B.M. Airport, Ranchi. SH - Construction of two nos. additional fixed finger routanda at B.M.Airport, Ranchi - Electrical Works.
2019_AAI_34899_1
AAI/RC/ENGG/ROUTANDA/2019-20
Open Tender
Electrical Works
Works
150 days
AAI, B.M.Airport
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,120
AIRPORTS AUTHORITY OF INDIA
₹61,631
21 Jan 2020
30 Oct 2019
11 Dec 2019
30 Oct 2019
4 Dec 2019
30 Oct 2019
30 Oct 2019 - 2 Dec 2019
Amount
Internal EI Works Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Internal EI Works Supplying and drawing following sizes of FRLSH PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
a) 1 x 1.5 sq. mm
b) 2 x 1.5 sq. mm
c) 2 x 4.0 sq.mm
Internal EI Works Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Internal EI Works Supplying, installation, testing and commissioning of following ways surface/ recess mounting, double door, 415 volts, TPN MCB distribution board, double door type suitable for three phase outgoings made of sheet steel, dust protected, duly phosphatized and painted, tined copper busbar, ( without MCB's) , common neutral link, earth bar, din bar for mounting MCB's, detachable gland/ knock out plate, superior make terminal connectors for all incoming and outgiong circuits, interconnections etc. as required.
(8+12) way TPN, double door.
Internal EI Works Supplying, installation, testing and commissioning of following ways surface/recess mounting, double door, 240 volts, SPN MCB distribution board, double door type suitable for single phase outgoings made of sheet steel, 1.6 mm thick dust protected, duly phosphatized and painted, tined copper busbar, ( without MCB's) , common neutral link, earth bar, din bar for mounting MCB's, detachable gland/ knock out plate, superior make terminal connectors for all incoming and outgiong circuits, interconnections etc. as required.
12 way SPN, double door.
Internal EI Works Supplying and fixing 6 Amps to 32 Amps rating, 240 volts, C-series 10 KA MCB of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required :
(a) Single pole
(b) Single pole and neutral
Internal EI Works Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLSH PVC insulated copper conductor single core cable etc. as required.
Internal EI Works Wiring for light/ power plug with 2X4 sq. mm FRLSH PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLSH PVC insulated copper conductor single core cable for loop earthing as required.
Internal EI Works Supplying and drawing following pair unarmoured 0.5 sq mm PVC Insulated Telephone Cables for indoor applications confirming to TEC specification G/WIR06/02 in the existing surface/ recessed steel/ PVC conduit as required.
Internal EI Works Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Internal EI Works Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
a) 15/16 amp switch with Indicator
b) 6 pin 15/16 amp Multistandard Socket
c) Telephone Socket Outlet
Internal EI Works Supply of LED type recessed mounting Lumanaires 1'x4' having minimum system lumen output of 3600 lumens, maximum 36 watt input power, power coated CRCA housing with sufficient nos. of high power LEDS with suitable lens to ensure uniform distribution of light, integral elecronics power driver suitable for 230 V + 10% ,50HZ AC supply,Indoor, thermal management with heat sinks, average life of LED > 50000 hrs, power factor > 0.95, mounting arrangement with all acessories, etc as required. (LED, electronic driver, accessories shall have minimum 5 year warantee). (Model equivalent : Bajaj- SKYLUX BZRSLL 36 W GZ1 WH)
Internal EI Works Supply of LED type recessed Lumanaires 1'x4' having minimum system lumen output of 2800 lumens, maximum 28 watt input power, power coated CRCA housing with sufficient nos. of high power LEDS with suitable lens to ensure uniform distribution of light, integral elecronics power driver suitable for 230 V + 10% ,50HZ AC supply,Indoor, thermal management with heat sinks, average life of LED > 50000 hrs, power factor > 0.95, mounting arrangement with all acessories, etc as required. (LED, electronic driver, accessories shall have minimum 5 year warantee) . (Model equivalent : Bajaj-CONNECT BRTX 28 W LED 4F WH)
Internal EI Works Supply of LED type round recessed mounting downlighters Lumanaires having minimum system lumen output of 1200 lumens, maximum 12 watt input power, power coated CRCA housing with sufficient nos. of high power LEDS with suitable lens to ensure uniform distribution of light, integral elecronics power driver suitable for 230 V + 10% ,50HZ AC supply,Indoor, thermal management with heat sinks, average life of LED > 50000 hrs, power factor > 0.95, mounting arrangement with all acessories, etc as required. (LED, electronic driver, accessories shall have minimum 5 year warantee) . (Model equivalent: Bajaj-DOVEE BZSLO 12 W WH PRO)
Internal EI Works Installation, testing and commissioning of pre-wired, LED fitting / compact LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLSH PVC insulated, copper conductor, single core cable and earthing etc. as required.
Internal EI Works Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
a) 600 mm width X 50 mm depth X 2.0 mm thickness
Internal EI Works Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply & Laying of Cable Supply of following size power cables of 1.1 KV grade, XLPE insulated PVC Sheathed aluminium conductor cable, armoured, and PVC sheathed conforming to IS 7098 Part-I and as specified & as required.
a) 3.5 C x 50 Sq.mm
b) 3.5 C X 25 Sq.mm.
Supply & Laying of Cable Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray/ surface as required.
a) Upto 35 sq.mm. (clamped with 1 mm thick saddle)
b) Above 35 sq.mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supply & Laying of Cable Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
a) 3.5 X 25 sq.mm.
b) 3½ X 50 sq.mm.
Supply & Laying of Cable Supplying and fixing 4P, 125A MCCB with breaking capacity 50kA including providing and fixing SS MCCB enclosure on wall along with necessary accessories and connections complete as required.
Air Conditioning Supply, Installation, Testing and Commissioning of Ceiling mounted Chilled water Cassette units of 2.5TR capacity complete with pre-filter, fan section and Chilled water coil section, powder coated galvanized steel housing , 3-speed motors, drain pump complete as per specifications suitable to connect with existing HVAC system.
Air Conditioning Supply, Installation, Testing and Commissioning of Chilled water valve set for Cassette Units which includes 1 no. ball valve with strainer, 1 no. ball valve without strainer and 01 no. two way On-Off type Valve of dia 25 mm.
Air Conditioning Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with elastometric nitrile rubber including and over the protective covering of chilled water pipes complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
a) 50 mm dia. (32 mm thick insulation)
b) 25 mm dia. (32 mm thick insulation)
Fire Fighting- Sprinkler System Providing and laying MS (C Class) Pipe IS:1239 marked including all forged fittings and accessories such as screwed/welded flanges, tees, reducers etc. complete including painting, welding, jointing and neoprene gaskets, nuts, bolts etc. as required of the following pipes painted with one coat of primer & two coats of post office red enamel paint fixed in ceiling, walls, coloumns for all heights with hangers, supports and fasteners all as per drawing including chasing of walls/columns/ceilings etc. and making good the same complete as required (for Sprinkler System). Note:-The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150 mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35 mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
a) 50 mm dia
b) 40 mm dia
c) 32 mm dia
d) 25 mm dia
Fire Fighting- Sprinkler System Providing, fixing, testing & commissioning of sprinkler heads of the following type :
a) Pendant & rosette adjustable type with quartzond bulb operating temperature at 68 deg. C as per specification.
Fire Alarm Supply installation testing and commissioning of Multi Co-operative Sensing Type intelligent Analog addressable smoke detector with mounting based LED, soft addressing complete as required. (Equivalent to SIEMENS make/ Model: HFP-11 and suitable for SIEMENS make Fire Alarm Panel/ Model: XLS).
Fire Alarm Supply installation testing and commissioning of Remote LED indicator complete as per specification as required (Equivalent to SIEMENS make/ Model: HFP-11 and suitable for SIEMENS make Fire Alarm Panel/ Model: XLS).
Fire Alarm Suppy and laying of MS steel factory red painted conduit along with the fittings and saddles for drawing detector control cables on surface/recess above false ceiling/concealed space/wall concealed etc.
a) 20 mm dia
b) 25 mm Dia
Fire Alarm Supply and laying of 2 x 1.5 sq.mm. PVC insulated copper wire Fire alarm system arm cable (red) through conduits / surface/ recess / above false ceiling /concealed space/wall concealed, etc. for control cabling of all fire detection and alarm devices and interconnecting as required.
Guidance Signages SITC of internally illuminated LED based mandatory information Runway/ Taxiway guidance signages (as per ICAO standard) made of 2-mm anodized aluminium sheet/ profile frame and body , 4-mm thick glare free, UV, abrasion, high temparature resistant poly carbonate with non-specular surface and suitable back ground coloured vinyl. The letters and symbols made out from 3M film shall be internally pasted/screen printed with required colouring , suitable arrangement shall be made to function on series circuits through Constant Current Regulator by providing suitable converter with internal control circuits. Suitable arrangement shall be made for water tightness and locking arrangement, sign boards shall be uniformly internally illuminated with required number of LEDs of appoved make having 11 Nos LED’s of 0.5 W or equivalent, with thermal management having LED life >50000 hours to achieve required illumination level (average sign illuminace shall be at least : Red - 10 cd/sqm, Yellow - 50 cd/sqm, White - 100 cd/sqm), operated on input source of 2.8 Amps. to 6.6 Amps. constant current but excluding isolation transformer and should have uniform brightness across the entire range of current variation from 2.8A to 6.6A. Board shall have secondary leads protected with flexible pipe including nut bolt, frangible mounting legs with base flange, nut bolts etc. The board shall have necessary water proof protection and shall be as per latest ICAO standards in all respect. Each leg of the signage board shall be installed by anchor bolts, nuts etc. including providing and laying in position cement concrete 1:2:4 (1 cement:2 Coarse sand:4 graded stone aggregate 20 mm nominal size) of suitable dimension as per the direction of engineer-in-charge.
Guidance Signages SITC of Bay Indicator at stand fabricated with central split type opening for easy maintenance made of reinforced 2mm thick anodized aluminum profile with suitable support. The rear panel shall 1.2 mm thick with ready to install fitting for mounting on pole or façade. The long-life facia is UV stabilized polycarbonate face of 4mm thickness with special adhesive and vinyl pasting from inside of polycarbonate face. The board shall have hinged front face to allow easy access for maintenance. Even light distribution ensured due to LED array. The boards shall be internally uniformly illuminated with LED lamp (modules) and all other accessories including having individual LED drivers to work on 230V AC supply complete with all internal wirings, connectors etc.as required. The board shall be in aviation yellow colour or any other colour as decided by EIC.
Guidance Signages SITC of Location signage as per ICAO Standard made of high intensity retro-reflective encapsulated lens type sheeting pasted on 2 mm thick aluminium sheet. The signage matter will be of electro-cut computerized automated self adhesive retro-reflective sheeting. The size of the Board will be as per ICAO standards of 1100 mm height. The Board shall be fixed by means of rivets on 35mmX35mmX5mm Al frame as required and supported by means of one no. frangible post with base flange. The back ground colour and colour of lettering shall be as per ICAO specifications. Each leg of the board shall be installed by anchor bolts, nuts etc. including providing and laying in position cement concrete 1:2:4 (1 cement:2 Coarse sand:4 graded stone aggregate 20 mm nominal size) of suitable dimension as per the direction of engineer-in-charge.
Guidance Signages Supplying and fixing 63 Amps rating, 415 volts, C-series 10 KA TPN MCB of in the existing MCB DB complete with connections, testing and commissioning etc.as required.
National Electric Store
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .