| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Non Responsive |
| 5 | Rejected-Technical | Rejected-Technical Non Responsive |
Tender Value
₹18.4 L
EMD Value
₹37,000
Closing Date
29 May 2024, 3:00 pmClosed
Ex Engineer ED-1st Srinagar
Office of the Ex Engineer ED-1st Srinagar Basantbagh
Supply Installation Testing Commissioning of 630KVA 6.6-11 /.433 KV (dual ratio) 3 Phase 50 Hz outdoor type vector Group DYN 11 ONAN Cooled Copper Wound Step down Transformer confirming to IS 2026 at Yatri Niwas Panthachowk
2024_PDD_248728_1
EDI No 006 of 2024-25
Open Tender
Electrical Works
Lump-sum
10 days
Office of Executive Engineer Electric Division Ist
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Yes
Ex Engineer ED-1st Srinagar
₹37,000
Yes
1 Jun 2024
20 May 2024
30 May 2024
20 May 2024
29 May 2024
20 May 2024
20 May 2024 - 21 May 2024
Supply, Installation, Testing, Commissioning 630 KVA , 6.6-11/.433 KV (dual ratio), 3 Phase, 50 Hz, outdoor type, vector Group: DYN 11, ONAN Cooled, Copper Wound, Step down Transformer confirming to IS 2026 with Ratio changing mechanism
Supply, Installation, Testing, Commissioning of ST Poles 9 Mt SP-33
Supply, Installation, Testing, Commissioning of ST butt 12 Ft long
Supply, Installation, Testing, Commissioning of 0.05 ACSR Conductor
Supply, Installation, Testing, Commissioning of 11 KV Double Break isolator with earthing blade
Supply, Installation, Testing, Commissioning of G.I. Channel iron (100x50x6)mm (75x40x6)mm
Supply, Installation, Testing, Commissioning of LT Distribution Box with 630 Amp MCCB 3P (36 KA) adjustable for incomer & 200 Amp 3 P (16 KA) 4 No.s fixed for Outgoing Circuits
Supply, Installation, Testing, Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply, Installation, Testing, Commissioning of 11 KV LA (9KV,10KA,station type)
Supply, Installation, Testing, Commissioning of11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply, Installation, Testing, Commissioning of LT Shackle Insulators with Mukki Clamps
Supply, Installation, Testing, Commissioning of Galvanized Nuts & Bolts of sizes
Supply, Installation, Testing, Commissioning of Earthing complete for metering box (Spike earthing Rod 20mm,2.5 with G.I strip (25x3)mm)
Supply, Installation, Testing, Commissioning of Earthing of substation --Excavation of earth pit of dia 650mm & depth 3000mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply, Installation, Testing, Commissioning of Danger Plates
Supply, Installation, Testing, Commissioning of Anti climbing Device
Supply, Installation, Testing, Commissioning of Alumunium thimbles of sizes
Supply, Installation, Testing, Commissioning of SL Clamps
Supply, Installation, Testing, Commissioning of Al Paint
Supply, Installation, Testing, Commissioning of Red Oxide Primer
Supply, Installation, Testing, Commissioning of Cement bottoming 1:2:4 mix 9 Mt ST Poles
Supply, Installation, Testing, Commissioning of 400 mm² Single-Core Cable,1.1k V Grade, XLPE un armoured FRLS type
Supply, Installation, Testing, Commissioning of 11 kV HT Metering CT and PT Operated.
M/S QADRI ELECTRICALS
UBAID SUPPLIERS AND CONTRACTORS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .