Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical document are not as per requirement |
Tender Value
₹14.3 L
EMD Value
₹14,500
Closing Date
30 Dec 2021, 12:00 pmClosed
SE,EUDC-VII,Ciss-Gomti,LESA,
33/11 K.V. Substation,sct-5D,Vrandavan Yojna,LESA, Lucknow.
Different type of repairing and maintenence work in the area of various 33/11 KV Sub Stations and lines under jurisdiction of E.E., EUDD., Vrindavan, LESA, Lucknow
2021_MVVNL_657761_1
35/EUDC-VII/LESA/2021-22
Open Tender
Miscellaneous Works
365 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
A/CNo-1277784945,IFSC Code-CBIN0280140,
₹14,500
20 Jan 2022
18 Dec 2021
30 Dec 2021
18 Dec 2021
30 Dec 2021
18 Dec 2021
Amount
Safe carriage, Loading unloading with proper stacking of following material from ESC-Daliganj to Work site/Je-Dump Store
PCC Pole 8.5/9mtr long
S.T.P. Pole 9/11 Mtr Long
Different maintenance material Cable. Joint Kit, PVC Cable, ACSR wire, Insulators. Transformer oil, ABC cable, fuse Units, Fuse wire, back entry, spring contacts etc.
11 kv HT XLPE cable 3x185 sqmm, 3x120sqmm, 3x40sqmm, etc.
Fabrication and erection of missing/damaged wiremess fencing 02mtr. Height with gate and retaining wall including grouting of fabricated MS angle 65x65x6 mmsq support and its painting as per specification.
Repairing of damaged massonery transformer plinth of size as per requirement at site to maintain the height of 1.5mtr brick bllast, filling of sand in the hollow space, plastening of surface in ratio 1:4:6: and top of plinth 4" thickness concealing. (Including all materials and labour and T&P)
Repairing of damaged/ rusted steel tubular pole by digging of pit up to 2" for proper position putting 3nos. angle from of size 35x35x6 sqmm3 nos angle around the damaged part of pole and welding properly and also grouting and plastering 300 mm with cement concrets.
Erection of sub-station type Double pole on 9/11 meter long S.T. Pole along with fixing of necessary clamp/accessories required including fixing of straight M.S. 100x50 mm. Top channel 125x65x6mm (2240 mm long) one no. Dropper channel 100x50mm.(2028mmlong )/Angle 100x50 mm 02 nos with arrangement of fixing of 03 nos. Pin insulator including Sub-station base angle of 65x65x6mm (2250mm) channel 02 nos. earthing it properly as per RESPO specification.
Laying of 11 KV 3x185,3x120, 3x240Sqmm. XLPE Cable with drilling machine as per norms of UPPCL.
Erection, of single pole PCC/ST Pole 11 Mtr long with all accessories.
Supply and repairing/ replacement of damaged tailless fuse unit/materials on LT distribution piller box with clamping lug of required size of LT PVC.
500 Amp. 600 Volts.
300 Amp., 600 Volts.
Resagging of existing LT/HT line opening of ABC on service point and opening of consumers service cable after re-sagging of ABC re-connection of consumers service cable. (In breakdown time man power has been provided 24 Hours.)
Providing chemical earthing of existing 400/630 KVA transformer by boaring & lowering 20" electrode and put chemical for improve earthing resistance below than 1 OHM and connecting of transformer body and neutral with GL Strip.
Arresting oil leackage from transformer by replacement of oil seal, cork sheet and packing of transformer also replacement of bushing rod 250/400 KVA transformer along with L-piece.
Grouting and nozzelling of stay set complete 16X1800mm.sp. with cement concreat sand, brick, blast.
Re-grouting cable and laying cable during breakdown period/faults on main road etc.
Construction of ring main unit (RMU) to provide ring system and backfeed system to on feeder to another feeder to maintain 24 hours supply.
Top-up distilled water in battery bank time to time and maintain DC supply for healthy tripping also maintained water density.
Supply and fixing of DTS name plates on distribution transformers of size 24X24 mm with radium colour along with clamps.
Supply and fixing of Feeders (I/C cable & O/G cable) name plates on double pole and four pole of size 24X24 mm with radium colour along with clamps.
Shifting of transformer from one plinth to another plinth and installed trolly with the help of crane during repairing of plinth
Note-:The Tendering authority can split the tender among different bidders/cancel/modify the above tender without any reason
BALAJI BHAGWATI ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid