Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC 301 VARDHAMAN CHAMBER II VIKASPURI NEW DELHI 110018 | WEST | DELHI | 110018 | ₹1.8 Cr | L1 | Accepted-AOC EMD amount deducted from RA Bill. |
| 2 | L2₹1.9 Cr+₹8.7 L (4.81%)Rejected-Finance D S 185 186 SECTOR D LDA COLONY KANPUR ROAD LUCKNOW LUCKNOW UTTAR PRADESH 226012 | LUCKNOW | UTTAR PRADESH | 226012 | ₹1.9 Cr+₹8.7 L (4.81%) | L2 | Rejected-Finance Bidder not quoted lowest price. |
| 3 | L3₹2.1 Cr+₹25.1 L (13.8%)Rejected-Finance E 2 216 GROUND FLOOR SHIV RAM PARK NEAR LUCKY GARDEN NANGLOI NEW DELHI 110041 | WEST DELHI | DELHI | 110041 | ₹2.1 Cr+₹25.1 L (13.8%) | L3 | Rejected-Finance Bidder not quoted lowest price. |
| 4 | L4₹2.1 Cr+₹28.4 L (15.7%)Rejected-Finance 12 14 BRADY HOUSE VEER NARIMAN ROAD FORT MUMBAI 400001 MUMBAI MAHARASHTRA 400001 DL03E0007147 07AABCB4175F1ZW B R MSME STATUS AS VERIFIED | MUMBAI | MAHARASHTRA | 400001 | ₹2.1 Cr+₹28.4 L (15.7%) | L4 | Rejected-Finance Bidder not quoted lowest price. |
| 5 | L5₹2.4 Cr+₹54.0 L (29.8%)Rejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹2.4 Cr+₹54.0 L (29.8%) | L5 | Rejected-Finance Bidder not quoted lowest price. |
Tender Value
₹2.3 Cr
EMD Value
₹4.6 L
Closing Date
13 May 2022, 5:30 pmClosed
Jt. GM (EE).
Jt. GM (EE), AAI, SGRDJ International Airport, Amritsar.
Annual operation and maintenance of 3x600 TR (Carrier make), 3x300TR (York make), VRV and precision type air- conditioners, window/ split AC units, water coolers, RO system and water purifiers at SGRDJI Airport, Amritsar. (For 02 Years).
2022_AAI_113678_1
AAI/ASR/Engg(E)/eNIT-01/21-22
Open Tender
Electrical Works
Works
730 days
Amritsar Airport
As per Tender Document.
17 documents required · 17 mandatory
₹1,180
₹4.6 L
3 Oct 2022
23 Apr 2022
17 May 2022
23 Apr 2022
13 May 2022
23 Apr 2022
23 Apr 2022 - 29 Apr 2022
Amount
O&M of water cooled central Air conditioning system by operation of centrifugal type chilling machines (3 Nos.) of 600 TR capacity (Carrier make) and operation & maintenance of high side equipment such as chilled water pumps, condensor water pumps, cooling towers and low side equipment consisting of 43 nos. of AHUs of different capacities, ceiling suspended centrifugal fans, etc. complete as required and as specified in the contract agreement.
Supply and replacement of following items as and when required or as per the direction of Engineer-in-charge.
Belt (Part No. A-76)
Belt (Part No. A-78)
Belt (Part No. A-50)
Belt (Part No. B-65)
Belt (Part No. B-68)
Belt (Part No. B-76)
Belt (Part No. B-88)
Belt (Part No. B-95)
Belt (Part No. B-115)
Belt (Part No. 2600)
Belt (Part No. C-124)
Belt (Part No. C-118)
Belt (Part No. C-110)
Bearing No. 6310
Bearing No. 6309
Bearing No. 6308
Bearing No. 6307
Bearing No. 6312
Bearing No. 6313
Bearing No. 6315
Bearing No. 6316
Bearing No. 6209
Bearing No. 6210
Bearing No. P-212
Bearing No. P-213
Bearing No. UK-211
Gear Oil
O&M of water cooled central Air conditioning system by operation of screw type chilling machines (3 Nos.) of 300 TR capacity (York make) and operation & maintenance of high side equipment such as chilled water pumps, condensor water pumps, cooling towers and low side equipment consisting of 13 nos. of AHUs of different capacities, ceiling suspended centrifugal fans, etc. complete as required and as specified in the contract agreement.
Complete items of CPWD Schedule of Rates (DSR) HVAC 2018 (Rates shall be quoted in multiples eg. 0.99 or 1.01 for below/above. (Item includes Labour Cess, terminal building charges but excludes GST).
Annual all inclusive Comprehensive Maintenance Contract of RO/ water purifier RO system of AAI/ BCAS building having capacity of 10 Ltrs. per hour of make ION Exchange (Zero B Model) installed at AAI/ BCAS building including preventive & breakdown maintenance, attending to complaints/ faults/ breakdowns and taking rectification action, testing ensuring serviceablility / satisfactory working condition of RO system, maintaining of records / documentation etc. complete as required & as specified.
Annual all inclusive Comprehensive maintenance of Water coolers of all makes of capacity upto 40 litres installed at AAI/ BCAS building which includes replacement of defective compressor with company make original uncut compressor along with stablizers at different locations including providing all necessary consumables & spares complete as required & as specified.
Annual all inclusive Comprehensive Maintenance of following capacity Airconditioners of all makes which includes replacement of defective compressor with company make original uncut compressor along with stablizers at different locations including providing all necessary consumables & spares complete as required & as specified.
1.5 TR (Split Type)
1.5TR (Window Type)
2 TR (Split Type)
2 TR (Window Type)
3TR/3.8TR (Cassette / Floor mounted type)
Annual all inclusive Comprehensive Maintenance of following capacity Airconditioners of all makes which includes replacement of all defective parts, spares and consumables along with sockets and stabilisers, but excludes replacement of defective compressors at different locations, complete as required & as specified. Note: The compressors for these ACs are under warranty of their respective OEMs and are thus not covered in the comprehensive maintenance.
1.5 TR (Split Type)
2 TR (Split Type)
2 TR (Cassette Type)
Annual all inclusive Comprehensive maintenance of Water coolers of all makes of capacity upto 150 litres which includes replacement of defective compressor with company make original uncut compressor along with stablizers at different locations including providing all necessary consumables & spares complete as required & as specified.
Annual all inclusive Comprehensive maintenance of Water purifiers (RO) of following capacity at different locations. Items covered under this AMC : RO membrane, booster pump, Sediment Filter, Carbon filter, UV tube more than 10 W, Nano silver filter, adaptor, pipe & fittings,softner consumables & spares complete as required & as specified.
Annual all inclusive Comprehensive maintenance of Water Dispenser ,Floor mounted cooling type, 3 litres water storage capacity and cabinet capacity 16 Liters.
Blue star make Cooling Capacity 3 ltr/hr Hot water capacity 6 ltr/hr
Voltas/Media make Cooling Capacity 3 ltr/hr Hot water capacity 4 ltr/hr
Testing of Drinking Water through FSSAI authorised vendors as per IS:10500-2012 complete in detail (Chemical & bacteriological) testing including collection of sample from Airport premises & submission of test report after testing complete as required & as specified.
Testing of Drinking Water through Govt. Laboratory quarterly basis including collection of samples from Airport premises & submission of test report after testing complete as specified.
Annual operation of 4 x 18 TR Precision package Air - conditioning system of Stulz make installed at ASR/MSSR building in operational area involving round the clock operation, daily monitoring, maintaining the records/ documentation etc. as per detailed specifications, terms and conditions covered under this contract on all days i/c Sundays and Holidays and including deployment of man power round the clock in three shifts as required & as specified.
All inclusive Comprehensive Maintenance Contract of 4 x 18 TR Precision package Air - conditioning system of Stulz make installed at ASR/MSSR building in operational area complete including preventive & breakdown maintenance through OEM/authorized service agency, attending the complaints, ensuring serviceability/ satisfactory working condition of the system complete as required & as specified.
Annual all inclusive Comprehensive Maintenance Contract of VRV Type Air-conditioning system of AAI/ BCAS building of DAIKIN Make with 206 HP total capacity including preventive & breakdown maintenance of all equipment (IDU/ODU/control system) through OEM/authorized service agency, attending to complaints/ faults/ breakdowns and taking rectification action, ensuring serviceablility / satisfactory working condition of Air-conditioning system complete as required & as specified.
Annual all inclusive Comprehensive maintenance contract of Air cooled ductable Packged Air Conditioning Unit of Blue star make of following capacities with hermetically sealed scroll compressor operating on R-407/R-410 /Non CFC (Eco Friendly) installed at CCR hall first floor building including preventive & breakdown maintenance through OEM/authorized service agency, attending complaints, ensuring serviceability/ satisfactory working condition of the system complete as required & as specified.
16.5 TR - 04 nos. (Model: DPA1983R2A-I)
5.5 TR - 01 no. (Model: DPA661-R2A-I)
Rewinding of motors of pumps/cooling towers of following capacities with copper winding of suitable capacity as reqd complete in all respect. (Dismantled copper wire can be kept by the contractor & rewound motor shall have minimum warranty period of 06 (Six) months).
Overhauling of pumps of all capacities including replacement/repair of shaft, mechanical seals/gland dori, bearings, coupling tyre and greasing/oiling of all parts and replacement/repair of any other component required for efficient operation of the pumps complete in all respect.
Anoop Refrigeration
Supertech Engineers
Brady Services Pvt. Ltd.
Blue Star Limited
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .