Executive Engineer
RSAMB Electric Division Jaipur
Package 01/2022-23 Various Electrification work at KUMS Raisinghnagar
2022_RSAMB_275748_3
RSAMB/Elec/NIT-02/2022-23
Open Tender
Electrical Works
Percentage
120 days
Jaipur
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
EE RSAMB Electric Division Jaipur
₹42,240
Yes
3 Jun 2022
19 May 2022
31 May 2022
19 May 2022
30 May 2022
19 May 2022
Amount
Part-A (Providng and fixing of prepaid energy meter in mandi yard at KUMS - Raisinghnagar)
Design, supply, installation, testing and commissioning of KEYPAD operated, single, PREPAID, electronic energy meters for measurement of active energy (kWh) and Max Demand (kW MD) of 1P2W, Static, 1x240Volt / 3x240 Volt, 10-60Amps, Class 1.0, 50 Hz, LT AC Consumers as per the specifications given below:
Standard: The prepaid meter shall comply accuracy class 1.0 required for measurement of active energy & shall confirm to IS13779 with latest amendments
Operating Temperature: The prepaid meter shall suitable for satisfactory continuous operation under hot, tropical and dusty climate with reference temp of 27°C. The prepaid meter shall work to 55°C & 90% humidity
Current & Voltage: • The current rating shall be Ib=10 & Imax =60A • Reference voltage shall be 1x240Volt / 3x240 Volt with ± 30% • Frequency shall be 50Hz with ± 5% variance
Display & Keypad: The prepaid meter shall have a LCD display to see the consumption. The consumer display unit shall have high resolution LCD display that shall be connected with meter through RJ11/CAT-5 cable (Max length to 20m inclusive) & alphanumeric Keypad to feed the recharge token. The keypad IP rating shall be adequate to permit use with moist or wet.
• Display Parameters : The prepaid meter shall display Balance kWh, Cu kWh consumed, current month MD, date & time etc. parameters in auto scroll mode.
• The meter shall display following parameters in push button mode by pressing respective key like Approx days left, Last day/ week/ last 06 months kWh consumption, Overload limit, Date & Time, last recharge token, Cu recharge, meter no, alarm limit set, Active instant power, phase current, neutral current, last 06 months kWh consumption & MD, Balance kWh etc.
Auto cut of Device: The prepaid meter must have a low consumption programmable switch/ relay to disconnect the load incase of crossing maximum demand & Zero credit balance. The device must be internal to meter & could not accessible from outside. Max capacity of the programmable switch/relay shall be adequate to operate with 120% of Imax
Meter Enclosure: The prepaid meter shall be fixed in cost inclusive enclosure made of high grade engineering plastic to avoid shock & having provision of main cable incoming, outgoing load cable, data cable for consumer display unit etc
Communication Port: The prepaid meter shall have an optically isolated RS232 communication port as per IEC1107 to connect external communication device like CMRI for meter data downloading for analysis purposes. The meter shall have RS485 port for consumer display unit connection.
Payment Option: The prepaid meter shall accept recharge token of electricity consumption (kWh) using numeric 20 digits encrypted token that can be printed on a paper and punched manually into prepaid meter using meter keypad or display unit keypad.
Audible Alarm & LED: The consumer display unit shall give an audible alarm incase of low credit balance & overload. Consumer load shall disconnect after one minute incase of overload and shall resume by pressing zero key. A visual Bi-color LED shall also be provided on prepaid meter & display unit for low credit indication.
LCD Indication: The prepaid meter & consumer display unit LCD display shall have icon for supply phase, reverse current, earthed load, tamper etc. indications.
Tamper & Fraud proof: The prepaid meter shall operate normally under the following condition and such tampers shall be logged into the meter memory: i). Phase Current Reversal: The prepaid meter shall record energy consumption in forward direction only. ii). Neutral Current Reversal: The prepaid meter shall record energy consumption in forward direction iii). Phase & Neutral interchange: The prepaid meter shall record energy consumption in forward direction.
iv). Incoming Neutral removed and load is connected with earth wire: The prepaid meter shall remain OFF and no power shall draw through meter v). Partial or Full load bypass: The prepaid meter shall have DUAL element metering for both phase & neutral element and energy shall be recorded using higher current of any elements.
vi). Magnet Tamper: The prepaid meter shall log date & time incase of magnet is applied to meter and switch to Imax as defraud metering vii). Top cover open: The prepaid meter shall log date & time incase of meter top cover & base opening and consumer load shall disconnect instantly.
Prepaid Metering: The meter shall credit kWh through recharge token generated by vending server. Credited kWh shall decrease as per instant load of the consumer and last 06 month kWh & MD history shall be stored into meter NVM.
Any reputed make prepaid Kwh meter shall be acceptable for tender participates if they fulfil all below given pre-qualification requirement. * Vender must be Indian original energy meter manufacturer & of approved in Rajasthan discom. * Vender must have own R & D team & have CMMI level 3 software certification. * Vender must have their own NABL accredited meter testing lab * Vender shall have ISO 9001 : 2008, ISO 14001 : 2000 * Vender shall have metering experience of 6 years.
The work shall include all cable connections, sealing, fixing of prepaid meter on wall etc. as required at site for smooth operation of energy meters as desired by Engineer in-charge
(A) Single phase 1x240 volt class-I, 50 Hz. 10-60 Amp. prepaid electronic energy meter
(Genous, Secure, Neptune Make)
(B) Three phase 3x240 volt class-I, 50 Hz. 10-60 Amp. prepaid electronic energy meter
(Genous, Secure, Neptune Make)
Vending Software: Upgrading already existing software as vending station for vend codes (Tokens) generation suitable for kWh recharging of single/three phase prepaid energy meters along brief of the prepaid software is given below:
Client Based System: The software shall work offline where no need requires for internet connectivity
Rights Distribution: The software shall be user definition based where operational rights & roles shall defined by system admin as desired
System Configuration: The software shall have provision for flat tariff configuration, consumer database definition, Max load limit configuration, various MIS report generation etc.
20 Digits Token: The software shall generate 20 digits numeric token for meter recharging & its configurations.
Meter Analysis: The software shall be compatible for meter reading data uploading and its report generation accordingly
System Backup: The software shall have provision for auto backup and on-demand backup for recovery purposes
The System emergency credit limit should incresed from upto 100 units
The system can be setup to define friendly credit house to avoid any inconvenience during odd hours
a. No disconnections on weekends.
b. No disconnections during night hours.
c. No disconnections on public holidays.
d. Update of the calender for public holidays is performed using handheld device.
e. Token Generation for Recharging any amount
The meter can decrement the credit to register negative values if the load could not be disconnected when the credit has been consumed dut to friendly credit hours. The debit is subtracted in the next credit transaction
Certificate :-
i. Item taken in the detailed estimate as specified are not available in Gem portal.
ii. Rates of non BSR items are lowest market rates.
iii. Market rate analysis as per general norms.
Repairing & improvement of updating software in existing prepaid energy meter due to technical parameters falt in prepaid meter complete update energy meter including display unit complete as required.
Part-B (Providing & maintenance of CCTVs Camera & annual maintenance & repair work in mandi yard at KUMS - Raisinghnagar)
SITC of IP 67, IK 10, full HD 1920x1080, 20-60 fps, 4 MP, ONVIF profile S/profile G, True day/night, Bullet camera having wide dynamic range up to 120 dB 2.8-12mm fixed lens with 16X digital zoom, S/N ratio 50-60 dB, Provision of Auto/manual white balance, gain control & on board micro SD card support, IPv6 ready, Supports all standard protocols, operating temperature range of 20 degree celcius to 50 degree celcius. The work includes complete installation, outdoor weather proof camera enclosure, mounting brackets, clamps etc. required for successful operation of system of make BOSCH/CP PLUS/ Honeywell (HBW4PER2) / Sony.
SITC of IP 66, IK 10, full HD 2560x1440, 20-60 fps, 4 MP, ONVIF profile S/profile G, True day/night, PTZ Dome camera having wide dynamic range up to 120 dB 4.3-129mm fixed lens with 16X digital zoom, S/N ratio 50-60 dB, Provision of Auto/manual white balance, gain control & on board micro SD card support, IPv6 ready, Supports all standard protocols, focus mode auto, panning range 0-360 deg., operating temperature range of -15 degree celcius to 90 degree celcius. The work includes complete installation, outdoor weather proof camera enclosure, mounting brackets, clamps etc. required for successful operation of system of make BOSCH/CP PLUS/ Honeywell (HBW4PER2) / Sony.
SITC of network video recorder of 32 channel HD recording, user friendly operation with features to view record, playback, live view and remotely control the system simultaneously with 4 SATA interface to support 04 TB HDD, 19PoE, VGA output, HDMI, multiscreen display of 1/4/8/16 windows, recording regulations 4 K (3840x2160) recording device NVR, power consumption 6.9 watt, Ethernet LAN with RJ-45 connector of make, Samsung/Sony/CP-PLUS/Honeywell.
SITC of IP65 outdoor high gain wireless radio link of minimum 2.4-5.0 GHZ, upto 1200 Mbps speed, 16 dBi dual polarized, compliant with 802.11a, 802.11b/g/n, Multi operation support gate way/VVIP S/Client/Access Point/ Repeater. The antenna should have ESD protection of 15 KV, lighting protection 4 KV, integrated firewall, 64/128 bit WEP encryption, powered by passive POE injector/12 V DC supply. The work includes supply & fixing of weather proof MS box, S&F of 4 port switch, power distribution unit, connecting cables from camera to switch & antenna, complete work including making connection of power cable etc. as required for successful transmission of video data to control room of make WIS- NETWORK/TP-LINK/ALCON.
SITC of high performance 4 TB surveillance Hard Disc Drive to be fitted in existing NVR speed 7200 RPM, Dim. 82x111x21mm of make Western Digital (WD)/Seagate.Toshiba.
All in all comprehensive maintenance of wireless CCTV system including replacement of components, consumables, servicing etc. complete in all respect after defect liability period of the equipment to keep the wire less CCTV working through out the year.
Bidder Name
Amount
GANPATI COMMUNICATION SERVICES(GSTN-08AMAPG7177L1ZP)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .