| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC | ₹14.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹15.7 L+₹79,313 (5.31%)Rejected-AOC | ₹15.7 L+₹79,313 (5.31%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical 50 1 56 13 SURYA TOWERS ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | - | - | Rejected-Technical NA due to the firm is enlisted for Cat c (vi) Repairs Only. |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
13 Jan 2020, 6:00 pmClosed
Shri Vineet Modi
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
SPECIAL REPAIRS TO EXISTING FIRE ALARM SYSTEM (PANEL AND SMOKE DETECTOR) AT SDI AF
2019_MES_305885_1
87549CWEAFNMAR
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF MARATHAHALLI
AS PER NIT
5 documents required · 5 mandatory
₹500
GE AF MARATHAHALLI
₹52,000
Yes
12 Feb 2020
12 Dec 2019
14 Jan 2020
12 Dec 2019
13 Jan 2020
1 Jan 2020
13 Dec 2019 - 23 Dec 2019
Amount
Taking down of old existing fire detection/fire alarm panel complete with 2 loop micro sencor panel with heat/smoke sensor response indicator manual call point, wall sounder beacon, isolator base control wirings complete in all respect and making good existing surface to match with adjacent surfaces etc complete all as specified and directed by Engineer--in-Charge.
Supply, Installation,commessoning and Testing of 2 loop addressable surface mounting FACP certified to EN54-2/EN54-4norms with 8x40 character LCD capable of 127 devices per loop. The FACP shall be certified as meeting the requirements of EN54-2 and EN54-4 by a suitable, notified body. In order to facilitate re-configuration and system extension, the allocation of addresses to devices shall be independent of their physical arrangement on the loops.The FACP shall have an event log capable of storing the last 500 events that have occurred. Up to 127 individually addressed standard devices shall be configured on each addressable loop. Loop powered sounders incorporated as a sensor bases shall be available. The FACP shall have the capability to support sub-addressing of addressable modules. The FACP shall monitor all critical system components and interconnections, internal and external, such that a failure, which would prevent the correct operation of the alarm functions, causes the FAULT indicator to light and a message to be given on the alphanumeric display within 60 seconds of occurrence.The FACP shall support minimum Four access levels,flash EPROM, 4 Nos. of programmable relay controls. The FACP Shall be housed in Ms Powder coated Cabinet, complete with exclusive Notification Circuits, and with Fire, Fault & Auxiliary Relays.The Panel shall support to programmed as a node on a peer to peer network with other Panels.etc complete all as specified and directed by Engineer--in-Charge. Part No- Tl-001900/ (CF-HFP AP -2SS) Make- Ceasefire or equivalent/ higher specification model in Honeywell/LST/Securezone/Hochiki.
Supply installation , commessoning and testing of Analogue Addressable photo Electric smoke sensor with Short circuit isolator base having removable high performance chamber with Twin fire LED's allow 360 degree veiwing, lock mechanism ( sensor to base),can adjust sensitivity range between 1% to 4.5% obs/mtr at any level ,Electronically addressed, approved by LPCB. Flat Response technique which nullifies the need for having ionisation detectors. Devices include High Performance optical chamber for effective and accurate analysis of causes of fire. FAST addressing technique Flexible (programmed in any sequence), Automatic (stored in EEPROM), Secure (cannot be changed easily) and Time saving etc complete all as specified and directed by Engineer--in-Charge. Part No- TI 000067A/CF-ALN-E(HFP) Make - Ceasefire or or equivalent/ higher specification model in Honeywell/LST/ Securezone/Hochiki.
M & L Response indicator for detector above false ceiling etc complete all as specified and directed by Engineer--in-Charge. Make : Ceasefire/Honeywell/LST/Secure zone/Hochiki or as per Original Manufacturers recommendations make.
Supply, Installation,commessoning and Testing of Analogue Addressable Manual Call Point having status LED for Alarming & standby mode,inbuild short circuit isolator,Electronically addressed approved by LPCB as EN54-11: 2001 . Rapid response using operation of a call point to the system indicating fire condition is typically less than 1.5 seconds FAST addressing technique Flexible (programmed in any sequence), Automatic (stored in EEPROM), Secure (cannot be changed easily) and Time saving complete.etc complete all as specified and directed by Engineer--in-Charge. Part No- TI-002056/(CFHCP-E (HFP)- SCI) Make - Ceasefire or or equivalent/ higher specification model in Honeywell/LST/Securezone/Hochiki.
Supply, Installation,commessoning and Testing of An Addressable Loop-Powered Wall Sounder Beacon as per the CHQ-WS but additionally featuring an integral beacon within the horn which utilises high intensity LED technology. Special bases available: YBO-R/3(RED), YBO-R/ SCI(RED), YBO-R/3(WHT) and YBO-R/SCI(WHTSNDR). etc complete all as specified and directed by Engineer--in-Charge. Part No- TI000800/CF-CHQ.) Make - Ceasefire or or equivalent/ higher specification model in Honeywell/LST/ Securezone/Hochiki..
Supply, Installation,commessoning and Testing of Isolator Base fully monitored for short/Open circuit compatible with ESP Analogue Addressable Protocol,Electronically addressed, approved by LPCB,unit incorporated an amber LED to show when it is isolating a section of a Loop. etc complete all as specified and directed by Engineer--in-Charge. Part No. TI- 000073/CF-YBO-R/SCI Make Ceasefire or or equivalent/ higher specification model in Honeywell/LST/Securezone/Hochiki.
Supply, Installation,commessoning and Testing of Armoured electric control cable (heavy duty) with stranded copper conductor cable of size 1.5 sq mm 2 core 1100 volt grade Note Rates quoted are deemed to be included for Laying , clamping, with suitable size pvc conduit and its accessories and necessary excavation returning filling where ever necessarye and making good to disturbed sirface of wall floor etc. complete all as specified and directed by Engineer--in-Charge. Make: Havells/Finolex/Polycab
Supply, Installation,commessoning and Testing of Armoured electric control cable (heavy duty) with stranded copper conductor cable of size 2.5 sq mm 2 core 1100 volt grade Note Rates quoted are deemed to be included for Laying , clamping, with suitable size pvc conduit and its accessories and necessary excavation returning filling where ever necessarye and making good to disturbed sirface of wall floor etc complete all as specified and directed by Engineer--in-Charge.. Make: Havells/Finolex/Polycab NOTE for Ser No 2 to 9:- (A) Design and Testing of Fire alarm:- (i) The contractor is responsible to obtain Design of the proposed fire alarm system complete in all respects from the Original Manufacturers/ Manufacturers authorized Distributor/ dealer by considering Sch BOQ items and ground requirements and submit the same to the Garrison Engineer along with Make approval letter. (ii) The Contractor is responsible to carry out the entire work by the manufacturers Engineers/ Manufacturers recommended consultancy/ firm/ team being a specialized nature of work. (iii) After completion of entire work on the ground in all respects and before issuing of the completion by Garrison Engineer, the contractor is responsible to carry out testing of entire fire alarm system in all respects as per manufacturers recommendations by their Engineers in the presence of Officer as detailed by the Accepting officer, Users representative and Engineer-in-charge etc.
M&L Boring of holes under road, Hard standing,Payment 1.5 to 2 mtrs below ground level by trenchless using ultra sounding technique and necessary tools takles machines including HDPE pipe of 40 mm dia for passing of U G cable complete Including Earth work to insert up to depth of 1.5 to 2 Mtrs etc complete all as specified and directed by Engineer--in-Charge.
M&L for cutting exixting road / PCC 100 mm thick for laying of LT UG cable and making good to the disturbed surface with cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate etc complete all as specified and directed by Engineer--in-Charge. (A) Digital Camera record :-Sl No 1 to 11. (i) The necessary photography and video to be recorded with digital camera by engineer-in-charge of JE of MCM electrician in the presence of contractor or contractor Engineer/ Supervisor (Digital camera to be arranged by Garrison Engineer to sub division) in respect of Sch 'A' BOQ items before commencement of execution, during receipt/ execution of Sch 'A' BOQ items / works on site in all respect along with boring, PCC and control cable works etc. The contractor is responsible to make a CD of the video and photos and to submit E-8 section along with each RAR for scrutiny, passing of bill and record purpose.
Satya Dharam Vikas Fire Safety & Security Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .