Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.2 LAccepted-AOC OPPOSITE J K BANK BAROO NH1 HAIDERY COMPLEX BAROO KARGIL BAROO KARGIL LADAKH 194103 | KARGIL | LADAKH | 194103 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹47.6 L+₹1.4 L (3.02%)Rejected-AOC | L2 | Rejected-AOC Not accepted being L2 bidder | |
| 3 | L3₹51.4 L+₹5.2 L (11.3%)Rejected-AOC 84 B LOWER BURDWAN COMPOUND RANCHI 834001 JHARKHAND | RANCHI | JHARKHAND | 834001 | L3 | Rejected-AOC Not accepted being L3 bidder | |
| 4 | L4₹52.3 L+₹6.1 L (13.2%)Rejected-AOC | L4 | Rejected-AOC Not accepted being L4 bidder | |
| 5 | L5₹55.0 L+₹8.8 L (19.1%)Rejected-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L5 | Rejected-AOC Not accepted being L5 bidder |
Tender Value
₹77.7 L
EMD Value
₹1.4 L
Closing Date
4 Jan 2020, 6:00 pmClosed
CWE Panagarh
HQ CWE PANAGARH, POST-PANAGARH, DIST-BURDHWAN, PIN-713420,WB
SPECIAL REPAIR / REPLACEMENT OF OH LT LINE TO LT UG CABLE IN CERTAIN AREA AT PANAGARH MIL STN UNDER GE PANAGARH
2019_MES_302426_1
8576/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Panagarh
As per tender documents
7 documents required · 7 mandatory
₹1,000
GE PANAGARH
₹1.4 L
Yes
9 Jan 2020
30 Nov 2019
6 Jan 2020
30 Nov 2019
4 Jan 2020
21 Dec 2019
Amount
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth and getting out in soft/loose soil,complete all as specified and as directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in soft/loose soil , complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exc. 1.5 m above the starting point , complete all as specified and as directed.
Supply and laying for dry river sand filling for cable protection with a layer of 8 cm deep before laying and 15cm covering above the top edge of cable after laying, complete all as specified and as directed. (Note : Punned thickness shall be measured and paid).
Supply and laying well burnt Sub Class 'B' locally available best quality laid in trenches perpendicular to UG cable above sand cushioning for cable protection, complete all as specified and as specified.
M&L for 80 mm bore GI tubing medium grade ISI marked for protection of cable including necessary joint ,complete all as specified and as directed. (Make TATA/JINDAL/BANSAL).
M&L for 40 mm bore GI tubing medium grade ISI marked for protection of cable including necessary joint , complete all as specified and as directed. (Make TATA/JINDAL/BANSAL).
M&L for heavy duty XLPE insulated, screened, PVC bedded galvanized steel strip armoured heavy duty electric cable with aluminium conductor cross sectional area 400 Sqmm 3.5 core of 1100 volts grade laid in trenches or passing through pipe and testing , complete all as specified and as directed. (Make : KEI/HAVELLS/FINOLEX/NICCO/POLYCAB/RR KABEL) Note : (i) Earth work in excavation, sand cushioning, cable cover, cable protection, GI pipe shall be measured and paid separately under relevant items. (ii) Cable route indicator of metal of height 300 mm above GL duly written "LT CABLE" on every 30 mtr to be fixed with PCC, 150 mm below the GL , Cost of route indicator and PCC for fixing indicators to be deemed in this item rate.
All as per item No 08 here-in-before but 185 Sqmm 3.5 core ,complete all as specified and as directed.
All as per item No 08 here-in-before but 150 Sqmm 3.5 core ,complete all as specified and as directed.
All as per item No 08 here-in-before but 120 Sqmm 3.5 core ,complete all as specified and as directed.
All as per item No 08 here-in-before but 95 Sqmm 3.5 core ,complete all as specified and as directed.
All as per item No 08 here-in-before but 70 Sqmm 3.5 core ,complete all as specified and as directed.
All as per item No 08 here-in-before but 25 Sqmm 4 core ,complete all as specified and as directed.
All as per item No 08 here-in-before but 16 Sqmm 4 core ,complete all as specified and as directed.
All as per item No 08 here-in-before but 16 Sqmm 2 core ,complete all as specified and as directed.
All as per item No 08 here-in-before but 10 Sqmm 2 core ,complete all as specified and as directed.
M&L for heat shrink type straight through jointing kit for 1.1 KV XLPE/PVC cables of size 6 to 16 Sqmm 4 core including testing after jointing, complete all as specified & as directed. Make : Birla-3M/Denson/Raychem.
All as per item No 18 here-in-before but 25 to 50 Sqmm 4 Core, complete all as specified & as directed.
All as per item No 18 here-in-before but 70 to 120 Sqmm 4 Core, complete all as specified & as directed.
All as per item No 18 here-in-before but 150 to 185 Sqmm 4 Core, complete all as specified & as directed.
Dismantling/taking out carefully of old LT cable of any size type or core and kept aside for reuse / rerouting / jointing / replacement etc, complete all as specified and as directed.
Dismantling / taking out old unserviceable bricks from the trench for taking out old cables etc. Staking aside for reuse or disposal, complete all as specified and as directed.
M&L for sheet metal enclosure for DBs 4 way double door TPN DB IP 43 suitable for MCCB 4 pole 63A as incomer and SP and/or TP MCBs (up to 40A) as outgoing including taking down old Unserviceable one ,complete all as specified and as directed. Make: Schnieder/legrand/L&T
M&L for MCCB Four pole 63A, 25kA, 415V,50Hz, complete all as specified and as directed. Make : C&S/Legrand/L&T/Indoasian.
M&L for MCB single pole 6 to 32 Amps 240 V 'C' series after and including taking down old Unserviceable one, complete all as specified and as directed. Make : C&S/Legrand/L&T/Indoasian.
M&L for sub main wiring with two singlecore PVC insulated cable with Copper conductor unshethered cable of size 4 sqmm drawn through & including PVC casing caping with 4 sqmm PVC insulated copper wire single core for continuous earthing complete all as directed . Make : Plaza/ Havells Note : Two run 4 sqmm of cable shall be measured as single run
Dismantling of cross arms of MS channel or angle iron sections etc complete and setting aside, complete all as specified and as directed.
Dismantling of insulators any type any size, complete all as specified and as directed.
Dismantling steel earth wire from existing overhead service feeder etc, complete all as specified and as directed.
Dismantling ACSR conductor of any size from existing overhead service feeder etc, complete all as specified and as directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, the earth plate surrounded by alternative layer of charcoal dust and salt with thickness of 150 mm to a packed thickness of 150 mm on all sides with and including necessary exacavation earth work including GI strip 25 X 4 mm as earthing lead connected with bolted and reveted to earth plate at one end in and connected to continuous GI strip 25 X 4 mm and including all as shown in electrical plate No 5 including taking down old unserviceable one, complete all as specified and as directed.
Supply, commissioning and testing Outdoor type LT Distribution Panel, Double Door type, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension (1500 x 2200 x 600)mm for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. . New Panel board shall comprise of :- (a) Copper Busbar rating- 800 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) ACB - 630 Amp, 4 pole, 50 KA Manually operated, microprocessor based, 415 V, 50 Hz AC-01 No(Incoming) (Make - L&T/Schneider/Seimens) (d) MCCB-200 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Outgoing) (Make - GE/Schneider/Seimens) (e) MCCB-160 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-04 No(Outgoing) (Make - GE/Schneider/Seimens) (f) MCCB-100 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-06 No(Outgoing) (Make - GE/Schneider/Seimens) (g) MCCB-63 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-04 No(Outgoing) (Make - GE/Schneider/Seimens) (h) S&F digital ampere meter 3 1/2 display incl CT having CTR 500/5-01 Nos (j) S & F digital voltmeter 0-500 V = 01 Nos
Supply, commissioning and testing Outdoor type LT Distribution Panel,Double Door type, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension (1500 x 1800 x 600)mm for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. New Panel board shall comprise of :- (a) Copper Busbar rating- 400 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-160 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Incoming) (Make - GE/Schneider/Seimens) (d) MCCB-100 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Outgoing) (Make - GE/Schneider/Seimens) (e) MCCB-63 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Outgoing) (Make - GE/Schneider/Seimens) (f) MCB-63 Amp, 4 pole, 10KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-04 No(Outgoing) (Make - GE/Schneider/Seimens) (g) S&F digital ampere meter 3 1/2 display incl CT having CTR 500/5-01 Nos (h) S & F digital voltmeter 0-500 V = 01 Nos
Supply, commissioning and testing Outdoor type LT Distribution Panel,Double Door type, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension (1500 x 1200 x 600)mm for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. New Panel board shall comprise of :- (a) Copper Busbar rating- 400 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-250 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Incoming) (Make - GE/Schneider/Seimens) (d) MCCB-200 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Outgoing) (Make - GE/Schneider/Seimens) (e) MCCB-100 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Outgoing) (Make - GE/Schneider/Seimens) (f) MCCB-63 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-04 No(Outgoing) (Make - GE/Schneider/Seimens) (g) MCB-63 Amp, 4 pole, 10KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-06 No(Outgoing) (Make - GE/Schneider/Seimens) (h) S&F digital ampere meter 3 1/2 display incl CT having CTR 500/5-01 Nos (j) S & F digital voltmeter 0-500 V = 01 Nos
Supply, commissioning and testing Outdoor type LT Distribution Panel,Double Door type, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension (1500 x 1200 x 600)mm for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. New Panel board shall comprise of :- (a) Copper Busbar rating- 400 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-250 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Incoming) (Make - GE/Schneider/Seimens) (d) MCCB-125 Amp, 4 pole, 36KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-02 No(Outgoing) (Make - GE/Schneider/Seimens) (e) MCCB-63 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-04 No(Outgoing) (Make - GE/Schneider/Seimens) (f) MCB-63 Amp, 4 pole, 10KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-06 No(Outgoing) (Make - GE/Schneider/Seimens) (g) S&F digital ampere meter 3 1/2 display incl CT having CTR 500/5-01 Nos (h) S & F digital voltmeter 0-500 V = 01 Nos
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure,complete all as specified and as directed.
Schedule of Credit
BANSAL CONSTRUCTION
UNITED BUILDERS
SARASWATI ENTERPRISE (INDEX NO CEEC D-81)
Prasur Electricals & Engineering Co.
Anmol Yash S.D. Construction Pvt. Ltd.
S. K. CONSTRUCTION SYNDICATE AND ENGINEERING CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .