Loading…
Loading…
Tender Value
₹54.3 L
EMD Value
₹1.3 L
Closing Date
12 Jun 2026, 10:00 pmClosed
Directorate of Municipal Administration
Mallikarjun JE
Construction of Dry waste processing unit at swm site in Kavitala town limit.
DMA/2025-26/BD/WORK_INDENT56273/CALL-3
DMA/2025-26/BD/WORK_INDENT56273/CALL-3
Open
Buildings
Two Tender Document System(Two Cover)
DMA Town Panchayat Kavithal
10 documents required · 10 mandatory
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs.32.10 lAKHS (50% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (PCC / RCC 136.76 cum, TMT Steel 3.36 Tonne, Structural Steel 5386.40 Kgs, G.S. sheet roofing 650.72 Sqm, Solid Concrete Blocks 508.9 Sqm) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. 32.10LAKHS (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. 32.10LAKHS (not less than 50% of electrical works) n any one yea
Owning the following key and critical equipment for this work
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. 64.20Lakhs)
Liquid assets and /or availability of credit facilities of no less than Rs. 19.26 Lakhs (estimated cash flow for 3 months of peak construction period)
₹1,360
₹1.3 L
5 Jun 2026
5 Jun 2026
15 Jun 2026
11 Jun 2026
Construction of Dry waste processing unit at swm site in Kavitala town limit.
Earth work excavation for Foundation by mechanical means for all works depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, cautio...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS...
providing size stone mesonry with hard stone in foundation and plinth with cement mortar 1:6 ( 1 CEMENT : 6 COURSE SAND ) ---- approve
Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub-structure works of bridges, Drain works other parallel works from 0.50m to 3.50 m height. Th...
Providing and laying in position Reinforced cement concrete for all super structures of building, road works, watrworks irrigation works & super structures works of bridges, from 0.50m to 3.50 m h...
Providing and laying in position Reinforced cement concrete for all super structures of building, road works, watrworks irrigation works super structures works of bridges, from 0.50m to 3.50 m he...
Providing and laying in position Reinforced cement concrete for all super structures of building, road works, watrworks irrigation works & super structures works of bridges, from 0.50m to 3.50 m h...
Supplying, Fitting and Placing TMT Fe 500 550 D , steel reinforcement as per Drawing and Technical Specifications. For Building works ---- approve
Providing fixing corrugated G.S. sheet roofing including vertical
curved surface fixed with polymer coated J or L hooks, bolts and nuts 8
mm diameter with bitumen and G.I. limpet washers or with G....
Providing and fixing Steel work in built up tubular round, square or
rectangular hollow tubes etc.trusses etc., including cutting, hoisting,
fixing in position and applying a priming coat of ...
Providing and laying in Cement Concrete for all Basement surface level
works, return walls, retaining walls, sunken floors etc. The granite/trap/
basalt crushed graded coarse aggregates and fi...
Providing and constructing load bearing wall with Solid Concrete blocks of size
400x200x200mmhavingblockdensitymorethan1800kg/m3andminimumcompressive
strengthof4.00Nper mm2conformingtoIS2185 2005and...
Providing and fixing G.I.chain link fabric fencing of required width in meshs ize 50x50mm
including strengtheningwith 2mmdiawire or nuts, bolts andwashers as required
completeasper thedirectionofEngi...
Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:
6 fine sand) including rounding off corners wherever required smooth
rendering, providing and removing scaffolding, including cost of m...
Finishing walls with Acrylic Smooth exterior paint of required shade :New
work (Two coat applied 1.67L/10 m² over and including priming coat of
exterior primer applied 2.20 kg/10 m²) with paint...
Supplyingandfixingrollingshuttersofapprovedmake,madeof requiredsizeM.S. laths,
interlocked together through their entire lengthand jointed together at theendbyend
locks, mounted on specially designed ...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
GEN-KW-3 DWP UNIT.docx
Tender Document • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .