Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.1 CrAdmitted-Finance | -33.33% | ₹3.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.2 Cr+₹9.6 L (3.09%)Admitted-Finance | -31.27% | ₹3.2 Cr+₹9.6 L (3.09%) | L2 | Admitted-Finance |
| 3 | L3₹3.3 Cr+₹23.9 L (7.69%)Admitted-Finance R O FIRDOUS COLONY BUCHPORA SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | -28.20% | ₹3.3 Cr+₹23.9 L (7.69%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | - | Rejected-Technical multiple necessary documents not uploaded |
| 5 | Rejected-Technical | - | - | - | Rejected-Technical experice certificate for similiar nature work not uploaded and has not uploaded requiste MOU |
Tender Value
₹4.7 Cr
EMD Value
₹9.3 L
Closing Date
24 Nov 2025, 6:00 pmClosed
Executive Engineer RnB Div Sgr Core
Office of The Executive Engineer RnB Division Sgr Core
Construction of compund walling including gate, Structural Steel Canopy. Water storage Tanks with underground Sump, Approach Road for GDC Eidgah
2025_PWDJK_294047_1
46 of RNB//Sgr-Core/2025-26
Open Tender
Civil Works
Percentage
365 days
Eidgah Srinagar
please refer tender docs
4 documents required · 4 mandatory
₹5,500
Executive Engineer RnB Div Sgr Core
₹9.3 L
Office of the SE RnB Circle Sgr North
15 Dec 2025
3 Nov 2025
25 Nov 2025
3 Nov 2025
24 Nov 2025
3 Nov 2025
14 Nov 2025
Civil Part
Supply and filling of earth including breaking of cloding , leveling, rolling with half tonne roller each and every third layer not exceeding in 20cm in depth including watering compaction of top most layer with 8-10 tonne road roller including carriages for a lead of 20 KM.complete job as per the directions of Engineer Incharge.
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth,consolidating each deposited layer by ramming and watering lead upto 50 m and lift upto 1.5m.
Dewatering of seepage water from trench by engagement of hydraulic motor with necessary pipe , and including using of fuel like petrol or diesel and engaement of skilled LABOUR FOR OPERATING OF PUMP INCLUDING ALL LEAD LIFT INVOLVED COMPLETE JOB
Boring, providing and installing bored cast-in-situ reinforced cement concrete pile of specified grade concrete mix, diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embeded in the pile cap etc. all complete including removal of excavated earth with all lifts and leads(Length of pile for payment Shall be measured from top of shoe to the bottom of pile cap) 450mm dia piles using M-25 grade of concrete
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor pile method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete Routine test (Test laod 1.5 times the safe capacity)
Providing and laying of hand packed soling stone consolidated rammed filling the voids compacting all complete carriage upto site of work all head loads complete job.
Providing and laying in position cement concrete mix (1:4:8) of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with:
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge.All works above plinth level upto floor V level using M-25 grade of concrete
Hours
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Electric Component
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns
Walls (any thickness) incl.attached pilasters,betresses,plinth and string cources etc.
Suspended floors,roofs,landing,balconies and access plateforms.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in charge. The product performance shall carry guarantee for 10 years against any leakage. (inside tank) a) For vertical surface two coats @ 0.70 kg per sqm
b) For horizontal surface one coat @1.10 kg per sqm.
Providing and applying of Polyurethane waterproofing coating (out side tank)for hohizontal and vertical surfaces
12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) in fine sand
6mm cement plaster to ceilings of mix 1:3 (1 cement : 3 fine sand)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing of submercible pump 1.5KW/ 1HP (CROMPTON) including all fixtures comp. job.
Pressure Pump with danfoss switch Kirloskar Brothers JALRAAJ-I ULTRA 1 HP incl all fixtures comp. job.
P/L, 75mm compacted thick WBM grade -ll with 63mm-45mm size stone with 1302mm screening incld supplying, spreading, watering and compacting with road roller to the required grade and camber spreading of binding material carriage of materials comp. job.(2 layers=150mm)
25mm nominal outer dia pipes.
50mm nominal outer dia pipes.
Providing and filling sand of grading zone V or coarser grade all-round the Composite Pipes in external work & lay dry brick over sand layer to protect the pipe. 110 mm dia. PP SWR socketed pipe with rubber ring joints .
Providing and fixing PP Based soil, waste and vent pipes (Silencio as per DIN4109) suitable to rubber ring joints, which includes bends, rubber ring, jointing, junctions, clean out plug , cowls, offsets, collar, M.S holder-bat clamps, access pieces, trap of self-cleansing design .etc. complete including jointing. For Under Ground Sewage System in the Existing Excavated Trench.of approved / standard Makes to be certified by the Engineer in charge 110 mm dia. PPSWR socketed pipe with rubber ring joints.
160 mm dia. PP SWR socketed pipe with rubber ring joints.
non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
160 mm dia. PP SWR socketed pipe with rubber ring joints.
Supply, Installation of PVC Gully Trap of Size 110 mm of approved / standard Makes to be certified by the Engineer incharge
Constructing brick masonry chamber for underground C.I. inspection Chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement :4 coarse sand) C.I cover with frame (light duty) 455x610 mm internal dimensions, total wieght of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)R.C.C top slab with 1:11/2 :3mix ( 1 cement : 1 1/2 coarse sand : 3 gradedstone aggregate 20mm nominal size), foundation concrete 1:5:10( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc., complete as per standard design: Inside dimension 455x610mm and 45 cm deep for single pipe line.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
Providing and fixing brass stop cock of approved quality. 15 mm nominal bore
20 mm nominal bore
Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality.
Brick work with common burnt clay (
A) T.Bolts i) 100 mm
Providing and fixing stainless steel (Grade 304) railing made of Hollowtubes channels, plates etc. including welding ,grinding, buffing, polishingand making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Structural steel work in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
C.G.I. SHEETS ROOFING Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Laying fibre reinforced M30 Grade (1:cement/1:sand/3:aggregate), upto 4 inches thick and positively admixed with: (a) A polycarboxylic ether (PCE) based, high range high performance super plasticising admixture based on polycarboxylic ether polymers with long chains specially designed to enable the water content of the concrete to perform more eff ecƟ vely. This eff ect can be used in high strength concrete to achieve highest concrete durability and performance with dosage @ 1-2% by weight of cement or its equivalent. The proposed Specific gravity of 1.07 ± 0.02 and pH value of 6.9 conforming with IS 9103:1999 and ASTM C494, Type A and G. (b) a high performance micro silica @2.5% by weight of cement will be added to the concrete mix. (c) a one component styrene butadiene rubber latex designed to improve the physical properties of cement mixes and slurries will be used. It has a Density (g/cm³): 1.020 ± 0.020 at +25°C, pH: 8 ± 1.0, Dry solids content (%): 36 ± 2%. Application temperature: from +5°C to +40°C, Density of mix (kg/m³) : 2,000, Compressive strength according to the EN 12190 (MPa): - after 1day: 7, after 7 days: after 28 days: 33, Adhesion to substrate according to EN 1542 (+21̐°C - 50% U.R.) (MPa): after 28days > 2.0
Providing and laying of a loosely laid, non-reinforced, cured, 1.2mm thick, single ply roofing EPDM Membrane conforming to ASTM D 4537 Type 1 Standards with Tensile strength of 9.0 Mpa, passing dynamic puncture resistance with 300% elongation, tear resistance of 26.27 kN/m & weather guarantee period of 15 years for all weather conditions at Srinagar (J&K) from a recognised and approved manufacturer (Firestone, Sika, STP, Mapei) as per required quantity with application of 2 sided tape from the same manufacturer with prior application of primer from the same manufacturer.
providing and fixing of stainless steel alphabits (304 ) grade as per requirement and desired by eic incl. all labour components like grinding, matching, fitting involved at site of work incl. all taxes involved upto site of work carriage, scafffolding, nuts, carriage complete job.
P/F of tubular steel section for gate of required length as per derection of incharge engineer with necessary red oxide and cutting, welding, bending, straighting, hosting incl. all carriage up to site of work complete job.
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screw. First class kail wood (35mm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work.
per letter
Providing and fixing panelling or panelling and glazing in panelled or panelle and glazed shutters for doors, windows and clerestory windows (Area ofopening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick. First class kail wood
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class deodar wood
Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Providing/Fixing of door window stard wire fittings
B) Handles
Providing/Fixing of door window stard wire fittings
C) L-drops (Link)
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Painting with cement bound paint of approved brand and manufacture to give an even shade. Two or more coats on new work.
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. NOTE:- To be used for maintenance work judicially necessary deduction for scaffolding in the existing item to be done
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 11.66.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
a) Carriage of stone aggregate for an average lead of 12km
b) Carriage of sand for an avg. lead of 18km
c) Carriage of bricks for an avg. lead of 50km
Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design
Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM Earth Wire
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Single pole and neutral
Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32 A F.P MCB 10 Ka "C" Curve
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying, installation of 20-25W Ground Recessed linear 600MM Washer 3000K Product Family JS-RL, Type of Item Outdoor WallWasher ,Warranty-2 Years, Wattage 20-25w ,IP Rating-IP65, LED Colour Temperature, White (6k)/Warm White (3k)/Neutral White , BodyMaterial Aluminium Die Cast , Beam Angle 15°/elliptical Product Dimensions in MM L-600mm x W-30 x H-30mm, Length 600mm , Width- 30mmHeight, 30mm ,Input Voltage ,12v/24v/220v ,PRODUCT OPTIONS LED Colour Options,Neutral White (4k)
Supply installation testing and commissioning of 15 W Updown lighter Pressure die-cast aluminium housing with specially designed optics, provide uniform light distribution to redefine outdoors and enhance architectural design with System efficacy of 100 lm/W.L70 life of 50000 Hrs. P.F.>0.95 with THD<10% ,CCT 5700 K,CRI 70,Surge Protection 4 Kv. Input voltage range of 120V to 300V.Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab.
Supply installation testing and commissioning of 30 W Flood Light made out of Pressure die-cast aluminium housing with specially designed optics, provide uniform light distribution to redefine outdoors and enhance ar
chitectural design with System efficacy of 100 lm/W.L70 life of 50000 Hrs. P.F.>0.95 with THD<10% ,CCT 5700 K,CRI 70,Surge Protection 4 Kv. Input voltage range of 120V to 300V.Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab.
4 X 10 sq. mm (25mm)
Supply installation testing and commissioning of 7 W COB IP65 Light with System efficacy of 100 lm/W.L70 life of 50000 Hrs. P.F.>0.95 with THD<10% ,CCT 5700 K,CRI 70,Surge Protection 4 Kv. Input voltage range of 120V to 300V.Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab.
3 Core 10 sq.mm
3 x 10 Sq. mm.
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required. 4.0 C X 10 Sq.mm A2XFY
LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin),SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty and Isolated Driver. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness > 0.50 mm) 36 watt
Approach Road BWO GSB
Engagement of JCB for removing of earthen humps, dressing of roads, removing and disposal of unwanted material outside the site complete job
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.72 MB
Tendernotice_2.pdf
PDF • 1.17 MB
BOQ_951214.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .