Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹63,800Qualified Make: APC
Model: UPS APC BX600C-IN 600VA B 163 SUPER BAZAR NAVDEEP HOUSE NEAR INCOME TAX CROSS ROAD ASHRAM ROAD AHMEDABAD AHMEDABAD CITY GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | Make: APC
Model: UPS APC BX600C-IN 600VA | ₹63,800 | L1 | Qualified |
| 2 | L2₹66,000+₹2,200 (3.45%)Qualified Make: APC
Model: APC MAKE BX600C-IN PATA MATA VIJAYWADA ANDHRA PRADESH 520010 | NTR | ANDHRA PRADESH | 520010 | Make: APC
Model: APC MAKE BX600C-IN | ₹66,000+₹2,200 (3.45%) | L2 | Qualified |
| 3 | L2₹66,000+₹2,200 (3.45%)Qualified Make: APC
Model: APC BX600C-IN ALIGANJ LUCKNOW 2845 226024 INDIA | LUCKNOW | UTTAR PRADESH | 226024 | Make: APC
Model: APC BX600C-IN | ₹66,000+₹2,200 (3.45%) | L2 | Qualified |
| 4 | L3₹66,660+₹2,860 (4.48%)Qualified Make: APC
Model: APC -APC BX600C-IN 36 DURGA PLAZA KAMLA NEHRU MARG DEWAS ROAD FREEGANJ UJJAIN MADHYA PRADESH 456010 UDYAM MP 49 0014085 | UJJAIN | MADHYA PRADESH | 456010 | Make: APC
Model: APC -APC BX600C-IN | ₹66,660+₹2,860 (4.48%) | L3 | Qualified |
| 5 | Disqualified Make: zebronic
Model: Zebronics U725 UPS 2 SHAH MARKET KATPIECE GALI BOMBAY BAZAR KHANDWA MADHYA PRADESH 450001 | EAST NIMAR | MADHYA PRADESH | 450001 | Make: zebronic
Model: Zebronics U725 UPS | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
11 Aug 2018, 5:00 pmClosed
Line Intractive UPS with AVR Experience with Gov. Required 2 Year (s) Line Intractive UPS With AVR ( 22 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 0.5/84 As per GeM Catalogue. Technology MOSFET-PWM MOSFET-PWM
IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP-21 IP-21
IP 20 Inverter Efficiency (%) >/= 60% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year 1 year
3 Years Warranty for Line Interactive UPS 2 Years 1 Year
2 Years
5 Years
3 Years Installation and commissioning instructions Yes - 1/4 CONSTRUCTIONAL Type of enclosure ABS - AC out put for printer (not through inverter) No Yes
No Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 Yes - 2/4 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date - - Name Of Lab - - Address of Lab - - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anand Mangalvedhe 500058
Quality Centre Building
DRDL
Kanchanbagh 22 15
448050
GEM/2018/B/63345
Line Intractive UPS with AVR
15 days
Telangana; Hyderabad
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Experience with Gov. Required 2 Year (s) Line Intractive UPS With AVR ( 22 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 0.5/84 As per GeM Catalogue. Technology MOSFET-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP-21 IP-21 | - | - | - |
| IP 20 Inverter Efficiency (%) >/= 60% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year 1 year | - | - | - |
| 3 Years Warranty for Line Interactive UPS 2 Years 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years | - | - | - |
| 3 Years Installation and commissioning instructions Yes - 1/4 CONSTRUCTIONAL Type of enclosure ABS - AC out put for printer (not through inverter) No Yes | - | - | - |
| No Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 Yes - 2/4 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date - - Name Of Lab - - Address of Lab - - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anand Mangalvedhe 500058 | - | - | - |
| Quality Centre Building | - | - | - |
| DRDL | - | - | - |
| Kanchanbagh 22 15 | - | - | - |
Exempted
11 Aug 2018
8 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_448050.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .