| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC NO 9 LAKSHMI NIVAS SOMASHETTAHALLI CHIKKABANAVARA POST BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹1.2 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹1.3 CrRejected-Finance NO 650 3RD CROSS MATHIKERE BANGALORE 560 054 | BENGALURU URBAN | KARNATAKA | 560054 | ₹1.3 Cr | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹1.3 CrRejected-Finance | ₹1.3 Cr | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 4 | L4₹1.3 CrRejected-Finance 121004 | ₹1.3 Cr | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 5 | L5₹1.3 CrRejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | ₹1.3 Cr | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| Sl No | Description | Qty | Unit | LAKSHMI ELECTRICAL ENTERPRISES L5 | A.GOVINDARAJ L3 | M/S SRI BALAJI ENTERPRISES L6 | LAKSHMI CONSTRUCTIONS L1 | shashi shekar construction L10 | Maruthi constructions L2 | RAMESH BABU CO L11 | Moulya Builders L9 | Neptune Engineers and Builders L4 | devan enterprises L8 | SREE BUILDERS L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed. | 1 | Cum | 750 ₹750 | 820 ₹820 | 1,424 ₹1,424 | 1,200 ₹1,200 | 703 ₹703 | 1,380 ₹1,380 | 822 ₹822 | 835 ₹835 | 700 ₹700 | 755 ₹755 | 700 ₹700 |
| 2.00 | M&L RCC, Cement concrete type B0 1:2:4 (12.5mm graded stone aggregate) as in floor/roof Slab and roof projection Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like similar work complete all as specified and directed. | 1 | Cum | 7,500 ₹7,500 | 7,500 ₹7,500 | 7,565 ₹7,565 | 7,800 ₹7,800 | 7,400 ₹7,400 | 7,456 ₹7,456 | 8,500 ₹8,500 | 8,500 ₹8,500 | 7,450 ₹7,450 | 7,450 ₹7,450 | 8,500 ₹8,500 |
| 3.00 | M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, column, beam landings and similar work n exc 200mm thick complete all as specified and directed. | 15 | Sqm | 420 ₹6,300 | 450 ₹6,750 | 676 ₹10,140 | 500 ₹7,500 | 390 ₹5,850 | 650 ₹9,750 | 400 ₹6,000 | 410 ₹6,150 | 400 ₹6,000 | 360 ₹5,400 | 100 ₹1,500 |
| 4.00 | M&L MS TMT bars 10 mm dia and above , cut to length ,bent to shape required , including cranking , bending , spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all as specified and directed. | 80 | Kg | 110 ₹8,800 | 120 ₹9,600 | 135 ₹10,800 | 120 ₹9,600 | 120 ₹9,600 | 128 ₹10,240 | 100 ₹8,000 | 105 ₹8,400 | 100 ₹8,000 | 125 ₹10,000 | 100 ₹8,000 |
| 5.00 | M&L for Dismantling/ taking down old existing unserviceable cement plaster, loose/ unsound weaken cement concrete of any description and in any position from existing external / internal surface of RCC roof/ slab/ beams/ columns/ RCC facias for an average depth of 25mm (Approx height 7.5m from natural ground level) with power driven pneumatic flat/pointed chisel and removing the honeycombed area including all the corners and making a neat profile of the cavities, roughen the smooth surface , scrapping out/removing corrosion all loose/scale/rust etc form the visible reinforcement by applying rust remover such as Rust Off 100 of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermax Limited( as approved by GE) and cleaning the steel reinforcement properly all as per manufacturer instructions and all as specified and directed and comprising of below mentioned process :- | 34 | Sqm | 1,100 ₹37,400 | 1,300 ₹44,200 | 1,325 ₹45,050 | 1,300 ₹44,200 | 1,000 ₹34,000 | 1,290 ₹43,860 | 1,250 ₹42,500 | 900 ₹30,600 | 1,250 ₹42,500 | 1,200 ₹40,800 | 1,200 ₹40,800 |
| 6.00(a) Providing cement based admixed with Sikacim, integral waterproofing liquid M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, , M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd (as approved by GE) @ 0.2% by weight of cement or as per manufacturer’s instructions over a coat of acrylic emulsion bonding agent such as per as Sika Latex in 1:1:3 ratio of Make M/s Sika India Pvt Ltd, or equivalent in M/S Fosroc chemicals, M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd (as approved by GE) having specific gravity of 1.02 or as per manufacturer’s instructions with necessary surface preparation such as creating mechanical key like roughening the surface by scrabbing, grit blasting and cleaning the existing surface using high pressure water jet machine having pressure upto 500 bar pressure to remove the dirt, dust, loose particles , wax, efforencene and other contaminations from the surface of RCC columns/ beams/ slabs/ facia/ any brick/ stone surfaces etc all as per manufacturer instructions and all as specified and directed by Engineer-in-Charge. | ||||||||||||||
| 7.00(b) Providing and applying FRIAZINC R, corrosion inhabiliting Active Zinc rich primer of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, , M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd (as approved by GE) along the exposed reinforcement surface property and allowed to dry. | ||||||||||||||
| 8.00(c) Providing and applying Hibond, Epoxy based Thixotropic bonding adhesive of Make of M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd ( as approved by GE) over the prepared concrete surface to get a good bonding between existing concrete surface and providing Sika Rep Microcrete 4 Fiber reinforced cementitious repair micro concrete of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd ( as approved by GE) over Epoxy based bonding agent applied area before 6 Hrs etc including providing necessary proportions , bracing and runners to relieve the member from the load coming on it including scaffolding leak proof shuttering with working platform as required and as per design and pattern complete including preparing the surface to match with the existing surface all as specified and directed. | ||||||||||||||
| 9.00(d) Note : The work under (Item No. 5 to 8 of BOQ) shall be carried out through authorized and qualified applicators of the any following manufacturer only. M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s STP Limited, M/s BOSTIk India pvt limited,M/s Thermax Limited | ||||||||||||||
| 10.00(i) A performance guarantee certificate for two years shall be submitted by the contractor to the GE on completion of work as specified. | ||||||||||||||
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
31 Mar 2026, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT TO WORN OUT SURFACES JOINERY WORK GLASS PANE WIRE MESH ROOFING PLINTH PROTECTION GEYSERS SOLAR WATER HEATERS CEILING FAN EXHAUST FAN AND CERTAIN MISC BR AND EM WORKS AT AFS JALAHALLI
2026_MES_755091_1
8301/E8
Open Tender
Civil Works
180 days
Garrison Engineer M AF Jaalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Garrison Engineer M AF Jalahalli
₹2.0 L
Yes
11 Apr 2026
3 Mar 2026
7 Apr 2026
3 Mar 2026
31 Mar 2026
24 Mar 2026
3 Mar 2026 - 10 Mar 2026
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L RCC, Cement concrete type B0 1:2:4 (12.5mm graded stone aggregate) as in floor/roof Slab and roof projection Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like similar work complete all as specified and directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, column, beam landings and similar work n exc 200mm thick complete all as specified and directed.
M&L MS TMT bars 10 mm dia and above , cut to length ,bent to shape required , including cranking , bending , spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all as specified and directed.
M&L for Dismantling/ taking down old existing unserviceable cement plaster, loose/ unsound weaken cement concrete of any description and in any position from existing external / internal surface of RCC roof/ slab/ beams/ columns/ RCC facias for an average depth of 25mm (Approx height 7.5m from natural ground level) with power driven pneumatic flat/pointed chisel and removing the honeycombed area including all the corners and making a neat profile of the cavities, roughen the smooth surface , scrapping out/removing corrosion all loose/scale/rust etc form the visible reinforcement by applying rust remover such as Rust Off 100 of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermax Limited( as approved by GE) and cleaning the steel reinforcement properly all as per manufacturer instructions and all as specified and directed and comprising of below mentioned process :-
(a) Providing cement based admixed with Sikacim, integral waterproofing liquid M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, , M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd (as approved by GE) @ 0.2% by weight of cement or as per manufacturer’s instructions over a coat of acrylic emulsion bonding agent such as per as Sika Latex in 1:1:3 ratio of Make M/s Sika India Pvt Ltd, or equivalent in M/S Fosroc chemicals, M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd (as approved by GE) having specific gravity of 1.02 or as per manufacturer’s instructions with necessary surface preparation such as creating mechanical key like roughening the surface by scrabbing, grit blasting and cleaning the existing surface using high pressure water jet machine having pressure upto 500 bar pressure to remove the dirt, dust, loose particles , wax, efforencene and other contaminations from the surface of RCC columns/ beams/ slabs/ facia/ any brick/ stone surfaces etc all as per manufacturer instructions and all as specified and directed by Engineer-in-Charge.
(b) Providing and applying FRIAZINC R, corrosion inhabiliting Active Zinc rich primer of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, , M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd (as approved by GE) along the exposed reinforcement surface property and allowed to dry.
(c) Providing and applying Hibond, Epoxy based Thixotropic bonding adhesive of Make of M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd ( as approved by GE) over the prepared concrete surface to get a good bonding between existing concrete surface and providing Sika Rep Microcrete 4 Fiber reinforced cementitious repair micro concrete of make M/s Sika India Pvt Ltd, or equivalent in M/s Fosroc Chemicals, M/s BOSTIk India pvt limited, M/s STP Limited, M/s Thermex Ltd ( as approved by GE) over Epoxy based bonding agent applied area before 6 Hrs etc including providing necessary proportions , bracing and runners to relieve the member from the load coming on it including scaffolding leak proof shuttering with working platform as required and as per design and pattern complete including preparing the surface to match with the existing surface all as specified and directed.
(d) Note : The work under (Item No. 5 to 8 of BOQ) shall be carried out through authorized and qualified applicators of the any following manufacturer only. M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s STP Limited, M/s BOSTIk India pvt limited,M/s Thermax Limited
(i) A performance guarantee certificate for two years shall be submitted by the contractor to the GE on completion of work as specified.
(ii) The unit rate quoted for item No. 5 to 8 of BOQ is deemed to be included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land Note: Periodicity of cutting of grass shall be before commencement of work and after completion of repairs.
M&L Repair to ends of chajjas/ parapets by removing old concrete, loose material & cleaning of the reinforcement and finishing the surface with rich cement mortar 1:3 , finished fair & even and making good with existing finishes complete all as specified and as directed. Note: Rate quoted by the tenderer shall be deemed to inclusive of double steel scaffolding.
M&L for providing and laying / fixing TPO membrane of non-flammable waterproofing of roof which shall be 1.5mm thick loose laid membrane using Fosroc Proofex ORG membrane, layers are overlaped to achieve a minimum weld of 110mm. Hot air welding can be either hand applied or by means of automatic machines and the roll's either end are overlapped with 110mm are in staggered position and the membrane shall be laid over the layers of non-woven geotextile fiber. The seperation layer provided to prevent the mechanical abrasion and cushioning between the fosroc proofex ORG membrane and the concrete substructure . The termination of fosroc proofex ORG by aluminium strip anchoring incl removal of existing treatment. Note: Work shall be executed directly by manufacturer or through their authorised and qualified applicators, of any following manufacturer only.M/s Fosroc chemicals, M/s Thermax Limited, M/s Tiki Tar Danosa India Ltd.
M&L Petty repair to existing roof treatment by means of torching to old APP membrane, sealing to joints, bitumen sealent,incl aluminium paint etc complete all as specified and direcetd
Petty repair to aluminium section/glass doors, windows, ventilators, partitions and making good the same size upto 2 Sqm (i.e. including change of Handles, hinges, star lock, rubber beadings, bottom bearing, clips etc) included taking down and refixing complete all as specified and directed.
Taking down and refixing MS window shutters n. exc 1.5 sqm through cutting of existing any type of hinges, handle and tower bolt and fixing new box type hinges, MS handle and MS tower bolt to the same window by necessary welding. The quoted rates shall be included the following aspect:- (a) Cutting of existing piano hinges, handle and tower bolt from window frame and shutter. (b) Fixing of removed shutter in the same frame on MS box type hinges 100mm, MS handle 100mm and MS tower bolt 100mm by welding. (c) Easing and adjusting the shutter before re-fixing if required. (d) Finishing the window frame and shutter with two coat of synthetic enamel paint. (e) Necessary scaffolding material to be included as the building height is more than 10mtr. Note : Box type hinges, handle and tower bolt shall be measured separately as supply only and labour element is deemed to be included in this item.
Supply only MS Handle 100mm.
Supply only MS tower bolt 75mm
Supply only MS Box type hinges 50mm.
Supply and fixing in repair steel window peg stay all as specified and directed.
Petty repair to door shutters for easy closing/opening (size upto 3 Sqm) including minor repair and easing, adjustment/alignment to openable with assessories and including taking down and refixing, tightening of hinges or changing the position of hinges,welding of hinges door to frame adjustment of tower bolts, sliding bolts with new screws etc, complete all as specified and directed.
Taking down chowkhat or frame (wooden/steel) exceeding 1.50 Sqm and not exceeding 4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
Taking down shutters of any description exc 1.0 Sqm and n.exc 2.0 Sqm each complete all as specified and directed.
M&L Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Supply and Fixing 30 mm thick factory made flush shutter solid core construction with block board core and plywood face panels, comercial type on both faces complete all as specified and directed.
S&F 2nd class hard wood 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); all as specified and directed.
S&F 2nd class hard wood 35mm thick Factory made plain framed panelled shutter (Two Panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
Preparation of new wood or wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
M & L Providing two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces all as specified and directed.
Supply and fixing 100mm long Butt hinges medium weight cold rolled stainless steel, and fixed complete all as specified and as directed.
Supply and fixing 200 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed.
S&F aluminium handles cast type anodised 200 mm long complete all as specified and as directed.
Supply and fixing 150 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed.
Supply and fixing aluminium handles cast type anodized 150 mm long complete all as specified and as directed.
S&F 300mm aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast- aluminium alloy and fixed complete all as specified and as directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed.
M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 sqm in each pane complete all as specified and directed.
M&L Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm thick plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass exc 0.5 sqm in each pane complete all as specified and directed.
S&F Aluminium body door closer hydraulically regulated,designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed including taking existing one complete as directed.
S&F in repair looking mirror of size 600mm x 450mm on commerical ply wood 6mm thick with PVC/ wooden moulding beading fixed to wooden plugs with chromium plated brass, screws and cup, washers, aluminium frame and fixed complete all as specified and directed.
Supply and fixing in repairs MS Mortise lock, 4 levers vertical type, size 100 mm for fixing to glass all as specified and directed.
Supply and fixing in repair 100mm long Butt hinges medium weight cold rolled stainless steel, fixed to wooden frame/welded to metal frame complete all as specified and as directed.
Supply and fixing in repairs 200 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed.
Supply and fixing in repairs aluminium handles cast type anodised 200 mm long complete all as specified and as directed.
Supply and fixing in repairs 150 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed.
Supply and fixing in repairs aluminium handles cast type anodised 150 mm long complete all as specified and as directed.
Supply and Fixing in repairs 300mm aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast- aluminium alloy and fixed complete all as specified and as directed.
S&F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed.
S&F in repairs 300mm, ordinary mild steel rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F in repairs floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm complete all as specified and as directed.
Petty repair to easing of wooden window, wooden ventilator, cupboard door, wardrobe door, PVC door, window shutters, kitchen cupboard shutters, show case shutter drawers including fixing of screws adjusting handles, knobs tightening piano hinges including misc small adjustments , (size upto 3 Sqm). minor repair and easying and adjustment/alignment to openable with accessories and including taking down and refixing complete all as directed.
Taking down chowkhat or frame(wooden/steel) not exceeding 1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
S&F in Steel windows with side hung shutters including projecting type hinges, frame with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F 4 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50sqm in each pane complete all as specified and directed.
S&F 4 mm thick sheet glass ordinary quality and glazing complete in square exc 0.50sqm in each pane complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and directed.
S&F Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and directed.
S&F in Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
Providing and injecting chemical for post constructional Anti TermiteTreatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same all as specified and directed.
S&F In repair MS anchor bolt fastner for fixing mosquito wire of dia 10mm and length n less than 15cm complete all as specified and directed
S&F In repair 4mm dia Galvanised mild steel plain wire fixed completed all as specified and directed
S&F in repair 20-25mm thick SS curtain rail incl brackets fixed into wall using wooden plug, screw etc complete all as specified and directed.
Supply & fixing factory made WPC single extruded 100% lead free ISO certified board of 18mm thick pre laminated Both side shutter for Kitchen/Room cupboard. The laminated shutter shall be of 0.14 micron prelaminated both side with different design and density not less than 700 kg / cum manufactured by an ISO 9001:2015 certified company. The 18mm board will be water proof, termite proof and borer proof and shall have good screw holding capacity complete all as specified and directed.Make-Black Kobra or Equivalent
Supply and fixing of stainless steel self closing hinges, 75mm size, 8 crank for cubboard shutter complete all as specified and directed.
Taking down and re-fixing the same existing aluminium door/window/partitions (each shutter area n. exc 5sqm) after carrying out certain repairs as required, removing the existing beading and fixing new (i.e. including change of Handles, hinges, star lock, rubber beadings, bottom bearing, clips etc) rubber beading of suitable size with adhesive, overhauling of floor springs including repairing/cleaning/greasing etc and making the same fully functional all as specified and directed.
Supply and fixing in repairs Powder coated aluminium (minimum thickness of powder coating 50 micron) frame work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws,included rubber beading complete all as per architectural drawings and as directed.
S&F in aluminium anodised grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC15) of approved design/pattern(DG 104), with approved standard section and fixed to existing window frame with CP brass/stainles steel screwnot less than 50mm and @ 200mm c/c, incl cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised alu standard section ( 28mm x 19mm x 2mm thick) around the opening
Supply and fixing in repairs powder coated aluminium for shutters of window and ventilator shutters, side hung type without sash bars/sliding type, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, star lock, including rubber beading complete all as per architectural drawings and the directions of Engineer-in-Charge.
S&F 5.50 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50 Sqm in each pane complete all as specified and directed.
S&F 5.50 mm thick sheet glass ordinary quality and glazing complete in square exc 0.50 Sqm in each pane complete all as specified and directed.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel covert governing pivot made of brass, other parts made of mild steel heavy duty in repairs complete all as specified and directed.
Supply and fixing Anodized aluminium size 605 x 605 mm snap grid frame work for false ceiling as per manufacturer instructions, with hangers of GI wire of suitable dia (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and 6mm thick Non asbestos fibre cement building boards, fixed to sheet suitably placed in false ceiling grid made of Aluminium/G.I./ M.S.as per specification and drawing and including dismantling old unservicable ceiling board including frame of any type and description, complete all as specified and directed.
M&L for Preparation of old decorated plastered or unplastered surface of wall, Washing, rubbing down and stopping of distempered and painted surfaces and applying one coat oil bound distemper complete all as specified and as directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, chajja, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applying one coat of white wash complete all as specified and directed.
Material and labour for Preparation of old plastered or unplastered surface of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for Preparation of old decorated surfaces of walls by Washing, rubbing down and stopping of distempered and painted surfaces,applying one coat of wall 1mm thick care putty and then applying two coats of premium oil bound distemper over one coat of primer as per manufauture instruction of required shade complete all as specified and directed.
Complete removal of existing water proofing treatment of any description and in any position including PCC padding any thickness and cleaning, wire brushing, watering & removal of debris outside MOD land. NOTE :- Unit rate quoted shall also include for removal of PVC water storage tank and water pipe lines wherever existing carefully and refixing at the same or other position after completion of roof repair work
M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) complete all as specified and directed.
Roughening surfaces of old concrete floors by picking, sweeping clean and washing down with waters to remove dusts etc. complete all as specified and directed.
M&L for Brushing neat cement slurry with 3kg/sqm all as specified and directed.
M&L Cement concrete 1:2:4 type B1using 20 mm graded stone aggregate as in lintels, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, padding, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed .
M & L for 10 mm thick screed bed or bedding layer of mortar in cement mortar (1:4) for laying roof finish as padding finished with liquid WPC as per manufacturer instructions, complete all as specified and directed NOTE :- Integral WPC shall be measured and paid separately.
Apply oil bound bitumen primer @ 0.40 Litre / Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg / Litre at 25 degree Celsius on the prepared dry roof surface complete all as specified and as directed.
M&L APP polymeric membrane min weight 3.0kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric(wt not less than 150 gms/sqm laid on primed surfaces by torch application method complete all as specified and directed.
M&L for preparation of new surfaces of any description not otherwise described over 10cm width or girth and applying two coats of solar reflective aluminium paint @ 0.10 kg/sqm of membrane surfaces complete all as specified and directed.
Removing plant/Uprooting of vegetation growth including roots on wall/roof/parapet near pipes etc and applying acid treatment after removing roots for preventing regrowth and making good disturbed surfaces/area in superficial area exc 150sq.cm but n.exc 400 sq.cm and averaging depth not exceeding 10 cm by using PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) or 10mm thick plastering in cement mortar 1:3 as required and finishing the surfaces to match with the existing surface complete all as specified and directed.
M&L for cement plaster rendering 15mm thick on fair faces of brick/concrete surfaces with two coats i.e. (10mm thick backing coat in CM 1:6 and 5mm thick finishing coat in CM 1:4) and mixed with liquid water proofing compound as per manufacturer instructions, finished even and smooth without using extra cement (WPC to be measured and paid separately) and Taking down old cement plaster on brick or stone walls, or concrete walls etc., hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises complete all as per specified and directed.
M&L applying two coat of cement based paint over a coat of primer, including preparation of newly plastered wall surfaces with smooth finish of any description, complete all as specified and as directed.
M&L for cement plaster rendering 10mm thick in CM 1:6 on fair faces of brickwork or concrete surface as on wall finished even and smooth without using extra cement and taking down old cement plaster on brick or stone walls, or concrete walls etc., hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises complete all as per specified and directed.
M & L for preparation of new plastered surfaces of walls applying wall care putty of one coat over plastered surface to prepare the surface even and smooth finish and applying two finishing coat of oil bound distemper over a coat of primer complete all as specified and directed.
M&L Vitrified Ceramic tiles 8-10 mm thick, (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer, 15 mm thick in Cement Mortar (1:6) complete including dismantling of existing old tiles and disposal to outside MD land all as specified and as directed.
M&L Vitrified Ceramic tiles 8-10 mm thick, (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertcal surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in coloured / white cement to match the tiles inc rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as in backing coat including dismantling of existing old tiles and disposal to outside MD land all as specified and as directed.
Material and labour for 25 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in flooring surface as in level course etc including demolition of existing old cement concrete, including disposal of demolition material upto 500mtr from MD land complete all as specified and directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc.complete all as specified and as directed
M&L Machine cut kota stone slab 20-25 mm thick as in flooring, laid over and incl 20 mm thick screed bed in CM 1:3 set and jointed in neat cement slurry and pointed with cement and pigment to match the shade of the slab incl rubbing and polishing complete all as specified and as directed.
Grinding of existing mozaic/kota stone/tiles in wall/flooring including mirror polishing, cleaning and joints filling and apply white cement complete all as specified and directed.
Supply and fixing in repairs 7 feet 4 pipes pulley operated cloths drying system consisting of aluminium pipe of outer dia 22mm, inner dia 19.80mm, made up of detrin with rope guide mounted on channel pair of length 24 feet (distance between two pipes is adjustable) locking system to hide rope knot, channel to be mounted or fixed with self taping screws provided in kit. Rope will be HDPE double core of 4mm dia fixing to ceiling as specified and directed by Engr-in-Charge and minimum weight of one pipe shall not be less than 0.20kg/, minimum weight of rope shall not be less than 7700Gms/unit. Make Easydry or equivalent.
S&F Pre painted Coloured Galvalume roofing sheets 0.50 mm thick having Zinc aluminium alloy coating double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws and including dismantling of any type of old sheets in roof coverings complete all as specified & directed.
S&F in repairs Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws etc, including dismantling of old one complete all as specified and directed.
S&F in repairs 0.56 mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) including dismantling of old one complete all as specified and directed.
M&L MS Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161-1979 grade St.-240 complete all as specified and directed.
M&L for Preparation of old painted surfaces of steel and applying one coat of synthetic enamel paint over 10 cm width or girth, not other wise described complete all as specified and as directed.
M&L for Treatment of the sunken floor slab comprises of the following specification and all as specified and directed. Make :- Dr Fixit/ M/s Sika india Pvt Ltd/ STP Ltd/ M/s Fosroc Chemicals
(a) Demolition of cement concrete filling of any description in sunken portion in toilet and removing debris outside MD land.
(b) Cleaning the sunken/ lowered portion of RCC slab surfaces (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope including cutting holes in bricks or RCC wall for spout (WPC shall be measured and paid separately)
(c) Rendering of uneven surfaces with 10mm thick in CM 1:4 mixed with integral water proofing as per manufacturer instruction. Fill it with water and check dampness and seepage. Where dampness/ seepage is noticed, nozzles shall be fixed and grouting carried out. (WPC shall be measured and paid separately).
(d) All junctions points of side wall spout where CI/ GI pipes are passing through shall be sealed with epoxy putty.
(e) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean.
(f) Material and labour for applying two coats of polymer modified cementious water proof coating as per manufactures instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.
(g) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound as per manufacturers specification including rounding of corners and junctions sloping towards spout. (WPC shall be measured & paid separately).
(h) Material and labour for PCC 1:5:10 type E2, n exc 150mm thick complete all as specified
(j) Material and labour for PCC 1:2:4 type B0 12.5mm thick aggregate, 50mm thick complete all as specified
Note for item No 103 to 112 :- Test the water proof area (ponding test) by filling water for at least 72 hours and tested for leakage, seepage to the entire satisfaction of GE.
Test shall be done in presence of Engineer-in-Charge.
The treatment shall be carried out by authorised applicator of chemicals. Cost of testing is included in the unit quoted rate above.
Supply Only integral water proofing compound complete all as specified and as directed. Make:-Dr. Fixit Pidi Proof and equivalent.
Note for item No 117 :- The work shall be carried out by authorised and qualified applicators of the above mentioned manufacturer.
M&L Petty repairs to leaking water in bib taps, pillar cock, stop cock, angle valve, concealed stop valve, bottle trap of any description by changing the PVC washers/ Sheet washers,spindle brass,jumper brass or any other minor accessories (incl taking down and refixing) complete all as specified and directed
S & F in repair bib tap standard of PTMT any colour screwed for iron pipe and fixed,15 mm bore (minimum weight 90gms) complete all as specified and as directed.
S&F in repairs of pillar tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-110gms) complete all as specified and as directed.
S&F in repairs of Stop Valve standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms) complete all as specified and as directed.
S&F in repairs 2 way bib cock with wall flange PTMT screwed down screwed for iron pipe in repairs 15mm bore complete all as specified and as directed.
S&F in repair of Push tap any colour high pressure of PTMT screwed for iron pipe and fixed, (Minimum weight 15mm-47gms) complete all as specified and directed.
S&F in repairs Vitreous China, half stall Urinal (back or corner wall type), complete including providing and fixing plugs, Urinal spreader, CP push cock, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and as directed
S&F in repairs PVC waste pipe 32/40mm bore for WHB, Urinal & Sink complete all as specified and as directed.
S & F in repairs vitreous china wash down water closet (Pedestral pattern) EWC white incl plastic water closet seat cover and mild steel chromium plated or aluminium hinging device and connecting to 'P' or 'S' trap incl connecting flush pipe with flushing rim complete all as specified and as directed.
Supply and fixing in repairs plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device all as specified and directed.
Taking down & re fixing high or low level flushing cistren 10 ltrs capacity & connections to pipes & fixing of chain & pull or lever after cleaning inside of all dirt, scale formation, replacement of including rubber washers, syphon set, float valve, handle,fixing to wall clamp/bracket, stopping of leakage etc wherever required complete all as specified and as directed
S & F in repairs PVC low level flushing cistern 10 Lit capacity including necessary brackets incl connecting flush pipe etc and making good the disturbed surfaces complete all as specified and as directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including taking down existing one complete all as specified and as directed.
S&F in repairs grating doom 125mm dia with waste hole of Chromium plated (Min wt 40 gms) complete all as specified and as directed.
Petty repair to internal/external water inlet water pipe line coming from over head tank to the quarter including socket,elbow,nipple ,with repair to water blockage , pipe line leakage, cleaning internally , removing the blockage including concealed water tubing etc of any height using scaffolding and and making the water supply functional complete all as specified and directed.
Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed.
Supply and fixing 20 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing complete all as specified and directed.
Supply and fixing in repairs 20mm dia gun metal gate valve with iron wheel screwed both ends for iron pipe all as specified and directed.
S&F Rotational moulded polyethylene water storage tank of 500 Ltrs capacity cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down old unserviceable tank complete all as specified and directed.
S&F in repairs of Swivel Shower with arm of PTMT any colour and 195mm long bend of 45 degree with flange for fixed with 15mm pipe(Minimum weight15mm-90gms) complete all as specified and as directed.
S&F in repairs Overhead Shower rose 125mm size (Brass Chrome Plated) complete all as specified and as directed.
S&F 300mm arc size, 5mm thick corner glass shelf with stainless steel brackets, stainless steel railing in bathroom and fixed to wall with brackets including removing the existing fitting as required at site complete all as specified and as directed
S & F in repairs PVC connection pipe 15 mm dia, 600 mm long with check nut and bolt with washer complete all as specified and as directed.
S&F Towel Ring stainless steel chromium plated round including taking down existing one complete all as specified and as directed.
S&F in repair Chromium plated soap dish including fixing arrangement complete all as specified and directed .
S & F in repair Toilet paper holder box type of vitreous china fixed to walls with chromium plated (CP) brass screws and complete all as specified and as directed.
S & F in repair tubular towel rail brass chromium plated 20 mm dia 'D' type 60 cm long between flanges complete all as specified and as directed.
S&F in repair vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, Urinal spreader, CP push cock, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed.
Petty repairs to refixing the existing Wash hand basin and Sinks made of stainless steel 1mm thick kitchen flat back with including fixing cantilever CI/Angle iron brackets embedded in concrete block including connecting waste coupling 32mm bore, including bedding, waste fitting, waste pipe in cement mortar to dwarf wall and connecting union to pipe, filling gap in white cement and all necessary fittings to fixed in repair (including taking down and refixing in same position) complete all as directed.
S&F Wash hand basin table counter type 560x400x200mm vitreous china (white) with cantilever CI/Angle iron brackets embedded in concrete block, including long shank pillar tap, Brass chromium plated waste coupling 32mm bore, Waste pipe bottle trap, including taking down existing one complete all as specified and directed.
S&F in repairs 40mm bore unplasticised PVC pipe of pressure rating 10 kgf/Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed.
S&F 32 mm Waste Coupling fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed including taking down existing one complete all as specified and as directed.
S&F Rotational moulded polyethylene water storage tank of 1000 Ltrs capacity cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down of old unserviceable tank complete all as specified and directed.
Cleaning of air/dust blokages in the internal water supply lines concealed or fixed on the wall or floor surfaces by dismantling the fitting such as taps, valves, unions etc to facilitate/stimulate clearance of blockages/airlocks and re fixing the dismantled items after clearance of blockage/airlocks including fiiitngs etc complete all as specified and as directed
S & F in repairs Bib taps cast copper alloy chromium plated fancy type screwed down screwed for iron pipe or for brass ferrule and fixed for 15 mm bore complete all as specified and as directed.
S & F in repairs pillar tap with capstan heads chromium plated fancy type screwed down high pressure with or without letter 'Hot' or 'Cold' with long screwed shanks and flynuts screwed for galvanised iron pipe and fixed complete for 15 mm bore complete all as specified and as directed.
S & F in repairs 15 mm dia stop valves of cast copper alloy fancy type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and as directed.
S&F In repair 25 mm dia Concussive push button taps of cast copper alloy, screwed for iron pipe and fixed
S&F Angular stop cock, chromium plated valves high pressure screwed both ends iron pipe or for unioins 15mm dia, including taking existing one complete as directed.
S&F CP Concealed stop cock, Regular body with adjustable wall flange screwed down screwed for iron pipe 15mm bore. including taking down existing one complete all as specified and as directed.
S&F in repairs 150 mm dia round/square grating of CP with or without hole including Jointed to PVC pipe complete all as specified and as directed..
S&F in repairs Wash basin vitreous china (flat back or angle back type) size 580x400mm including taps waste chain and plug and porceline stopper but brackets including cutting for and pinning in ends of brackets or erecting stand with waste pipe, complete all as specified and directed.
S&F in repairs 40 mm Waste coupling fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed one complete and all as specified and as directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450 mm including taking down existing one complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tank of 2000 Ltrs capacity cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down old unserviceable tank complete all as specified and directed.
Petty repair to wall mixer,basin mixer,sink mixer etc including replacement of spindle brass, Jumper brass, rubber washer, head incl taking down and refixing ete all as specified and directed
S&F Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm fixed in repairs all as specified and directed. Make : M/s Diamond / Nirali / Amco / TATA.
S&F in repair Brass Chromium plated wall mixer for mixing hot & cold water screwed down for 15mm bore iron pipe complete all as specified and directed.
S&F CP sink cock with swinging casted round shape spout screwed down screwed for iron pipe in repairs 15mm bore including taking down existing one complete all as specified and as directed.
S&F Plate rack of size 65 cm x 96 cm (heavy duty) made of stainless steel fixed in repairs complete all as specified and directed.
M&L Granite 18 to 20mm thick (table rubbed and polished) in steps,Jamps, Pillars, Windows, cills, platforms and like CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigments to match with marble shade of Granite over screed bed or bedding layer of mortar 20mm thick for laying floor finishes in cement mortar (1:4) all as specified and as directed.
M&L Repair to leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horinzontal pipe embeded in floor in bathroom or kitchen making good to the damaged portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed
M&L Repair to leakage/seepage from the wall/ door bend /door tee/ 'Y' junction/ 'T' Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC of the upper Qtr or at the ground floor Qtr including change of any damaged soil waste pipes or fittings of any shape, specification and size, making good to the damaged portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and finished the surfaces matching to existing wall to avoid the leakage/ seepage at the site of work complete all as specified and directed.
Note for item No 170 & 171 :- (a) Find out main cause of leakage and take necessary steps to resolve / rectify. (b) Replace existing tiles in case leakage through NT/FT. (c) The rate also include provision of new NT/FT. (d) The unit rate is also deemed to be included for reqd bonding chemicals to arrest the leakage/seepage as directed by the manufacturer's specification. Make : M/s Sika Chemical, M/s Pidilite, M/s Dr Fixit
S&F in repairs CP 2 way bib cock with wall flange fancy type screwed down screwed for iron pipe in repairs 15mm bore complete all as specified and as directed.
S & F in repair viterous china squatting pan 'Orissa pattern ' size 580 x 440mm white with integral foot rests incl connecting to 'P' or 'S' trap and to flush pipe anti syphonage pipe etc complete including provn of lime concerte bedding and making good to floor complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L for ceramic coloured tiles of size 350mmx250mm/ 300mm X 450mmx7 to 8 mm thick, on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured / white cement to match the tiles inc rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles etc complete all as specified and directed.
Dismantling floor, floor hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises and supplying and fixing Joint free Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile of size n exc 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incuding screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:6) complete all as specified and directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches bore of pipe 75 mm with PVC clamps and saddles including taking down old existing pipes and dismantling of cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches bore of pipe 110 mm with PVC clamps and saddles including taking down old existing pipes and dismantling of cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed
S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 75 mm complete all as specified and as directed.
S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 110 mm complete all as specified and as directed.
S & F in repairs PVC (SWR) junction single (single T) equal or unequal with access door bore of pipe 75 mm complete all as specified and as directed.
S & F in repairs PVC (SWR) junction single (single T) equal or unequal with access door bore of pipe 110 mm complete all as specified and as directed.
S & F in repairs 125/ 110 mm bore PVC (SWR) floor trap plain with grating incl jointing with solvent cement complete all as specified and as directed.
M&L for cement plaster rendering 5mm thick in CM 1:3 on fair faces of brickwork or concrete surface as on ceiling finished even and smooth and taking down cement plaster on ceilings surface etc., hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises complete all as per specified and directed.
M&L preparation of newly plastered surfaces of ceiling and applying three coats of white washing on ceiling surfaces with smooth finish complete all as specified and directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, washing down, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat of cement based paint complete all as specified and as directed.
M&L for preparation of old plastered surfaces of wall by using pressure washer, removal all dirt and dust and applying one coat of exterior emulsion weather proof paint complete all as specified and as directed.
M&L for Preparation of old painted wooden surface of any description and applying one coats of synthetic enamel paint not otherwise described over 10 cm width or girth, complete all as specified and directed.
Petty repair to renewing/matching glazed or ceramic coloured tiles in floors/walls in patches area not exceeding 5.00 Sqm including dismantling, removing and cleaning old tiles preparing beds and laying screed bed in CM 1:4 setting, jointing and pointing new or old tiles and joints filling and apply white cement and complete all as specified and directed
M&L polished Sadarahalli granite stone slab flooring 18-20 mm thick with grey cement slurry mixed with pigment to match the shade of the slab including 20mm thick screed bed in cement mortar 1:4 complete incl dismantling old stone slab complete all as specified and as directed.
M&L for 18 to 20mm thick polished sadarahalli granite tiles as in riser and dado of steps over 10mm thick cement mortar 1:4 incl dismantling old stone slab complete all as specified and as directed.
S&F in collapsible steel gates, top hung,consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets including dismantling old one , complete all as specified and directed.
M & L Providing one coat of synthetic enamel paint on steel surfaces n exc 10 cm width or girth including preparation of old steel surfaces all as specified and directed.
M&L for welding in repairs exceeding 2.5cm n exc 5cm length and exc 9mm n exc 20mm thickness of metal to be welded not exceeding 6mm complete all as spcified and directed.
M & L for 75 mm thick PCC type C1, 1:3:6 (20 mm graded stone aggregate) as in plinth protection finishing the surface even and smooth with using extra cement all as speecified and as directed.
Site clearance by Scraping of grass/wild growth/trees cutting n.exc 0.30m girth etc in soft/loose soil by manually/mechanically including removing of rubbish from the site to a distance exc, 250m but n. exc 500m and deposited where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed
Demolition of cement concrete (unreinforced) of Concrete of any description and in any position not otherwise specifically provided complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade with grey cement and pigment all as specified and directed.
M & L for Sand filling under floors or in foundations including watering and consolidation and all as specified and directed.
M&L Pre-cast PCC 1:3:6 type C1 (using 20 mm graded stone agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 built in cement mortar of any description complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar (1:4) on brick or concrete surfaces of wall and finishing the surface even and smooth without using extra cement complete all specified and directed.
M&L Inspection, checking adjustments and minor repairs of storage water heater 25/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :- (a) Inspection, taking out of drain plug & dewatering and re-fixing the same complete all as directed . (b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f) Checking functioning of heating element and correct setting adjustment of thermostat. (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) Replacement of defective spares shall be measured and paid under relevant items mentioned below separately as supply and fix.
Note : The following deemed to be inclusive in quoted rate :-
The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge before commencement of work.
In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
In case of minor defects, entire job shall be completed with in 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
The entire job will be carried out in entire area of Air Force stn Jalahalli
All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
Supply and fixing Heating element 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed.
Supply and fixing PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe including taking down existing one complete all as specified and as directed.
Supply and fixing in replacement thermostat switch range of 30-80 degree celsius suitable for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed.
Supply and fixing Heating element 2.0 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity ,any type and any make including taking down old one including washer/ packing suitable complete all as specified and as directed.
Supply and fixing in replacement pressure relieving valve CP brass confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed.
Material and labour for Cutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc including taking down existing one complete all as specified and directed.
Supply and fixing in replacement bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
Supply and fixing in replacement brass non return valves, screwed down, high pressure, screwed both ends for 15mm bore iron pipe or for union, ISI marked, complete all as specified and as directed.
Supply and fixing Outer body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enamelled paint including taking down existing one complete all as specified and as directed.
Material and labour for Grouting 4 Nos of M12 X100mm bolt in stone /brick masonry wall with 1:4 CM suitable for hanging geysers complete all as specified and as directed.
Supply and fixing Indicator lamp for geyser 25/50 ltr capacity of colour green & red complete all as specified and as directed.
Taking down carefully storage water heater (geyser) 25 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixing in repair of heavy duty pin type fastener 4" long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed. Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.
Material and labour for painting of outer surface of 25 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
Supply and install water heater storage type (Geyser) vertical of capacity 25 Ltr, suitable for high pressure up to 8 bar powder coated metal body, temperature indicating dial , glass line coated tank, magnesium anode, efficient long life copper heating element, wattage 2 KW electrically operated, AC 230 Volt, BEE 5 Star Rated with complete fittings/parts and accessories for fixing on wall/surface all as per site requirement and specified and directed . Note:- Old Unserviceable water heater shall be deposited to MES store yard. Make:- Bajaj / Racold / Havells
Supply and fixing in repair 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair Chlorinated PVC (CPVC)Gate Valve of size 20 mm dia, (ISI marked) complete all as specified and as directed.
Supply and fixing in repair 25 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair Chlorinated PVC (CPVC) Gate Valve of size 25 mm dia,( ISI marked) complete all as specified and as directed.
S&F in repair PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 Sqmm 3 core,complete all as spcified and directed. Make : Havells/ Polycab/ Plaza
Supply and fixing 15 mm dia Stop valves, fancy type, chromium plated with long shank and cup(concealed type),screwed down,high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S & F of bib tap cast copper alloy chromium plated, fancy type screwed down with screwed both ends for iron pipe 15 mm bore complete all as specified and as directed.
Taking down carefully storage water heater (geyser) 50 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including Supply and fixing in repair of heavy duty pin type fastener 4" long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed. Note :- Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness.
Material and labour for painting of outer surface of 50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No. on the geyser complete all as specified and as directed.
Dismantling carefully solar storage water heating system of 100/200/300 Ltr capacity any type for following works with testing and refixing the same in original position making all water/ electric connection to entire satisfaction of Engineer-in-charge after repair as under :-(a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank. (b) Checking water tightness of storage tank after cleaning. (c) Checking and correcting earth continuity of electrical items. (d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (e) Replacement of damaged solar cells (f) Necessary T&P such as ladder, helper shall be contractor responsibility.
Note : The following deemed to be inclusive in quoted rate :-
The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced to the Engr-in-Charge, before commencement of work.
In case of major defects, entire job shall be completed within 15 days from the date of registration of complaint, failing which penalty charges @ Rs. 500/- per day shall be recovered.
In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ Rs. 100/- per job shall be recovered.
The entire job will be carried out in entire area of Air Force stn Jalahalli
Necessary T&P such as ladder, helper shall be contractor responsibility.
All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
Supply and replacement of solar tube as per existing type complete all as specified and directed.
Supply and fixing in replacement thermostat switch suitable for solar water heater of any make and size complete all as specified and as directed.
Supply only solar cells to replace the damaged cells in the solar panel for solar water heater 200 Ltr capacity complete all as specified and directed.
Hose pipe for solar water heater panel suitable for 200/100Ltr capacity complete all as specified and directed.
Supply and fixing in replacement bib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe, ISI marked, complete all as specified and as directed.
Supply and fixing in replacement gate valve , cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 25 mm bore iron pipe, ISI marked, complete all as specified and as directed.
Supply and fix in replacement rotational moulded polyethylene water storage tank of 300 litres capacity three layered HDPE water storage tanks cylindrical vertical with closed top as per IS 12701-1996 hoisted and fixed in position, including provn of inlet pipe, over flow pipe, washout pipe etc complete all as specified and directed.
Material and labour for Staging / steel frame work for Solar water tanks using standard mild steel sections like angle iron / MS pipe / flat iron / sheets etc using steel of Fe 410-W (Gde E-250) quality - A including necessary welding suitable to keep 300 ltrs PVC water tank in repairs complete all as specified and directed.
Gasket set for solar water heater panel suitable for 100Ltr capacity complete all as specified and directed.
S&F in replacement Pressure switch of pressure pump suitable capacity of 0.5 HP to 1 HP complete all as specified and directed.
Supply and Fix in replacement of solar water heater tank 100 ltr capacity tank should be 1.60 mm thickness low carbon steel with porcelain coating, outer tank should be 0.4 mm thickness stainless steel 202 grade Non Magnetic grade, insulation in PUF 50mm including provn for suitable solar tubes complete all as specified and directed. Note :- Solar tubes shall be measured and paid separately
Supply and replace solar panel glass suitable for 100 ltrs capacity solar water heater with gasket complete all as specified and directed.
Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing and connection complete all as specified and directed..
Supply and fixing 20 mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking up or down old steel tubing and connection complete all as specified and directed..
Supply and fixing in repair 20 mm dia PPR Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair PPR Gate Valve (brass insert) of size 20 mm dia, (ISI marked) complete all as specified and as directed.
Supply and fixing in repair 25 mm dia PPR Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair PPR Gate Valve (brass insert) of size 25 mm dia,( ISI marked) complete all as specified and as directed.
Supply and fixing in repair 32 mm dia PPR Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair PPR Gate Valve (brass insert) of size 32 mm dia,( ISI marked) complete all as specified and as directed.
Supply and fixing in repair 40 mm dia PPR Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair PPR Gate Valve (brass insert) of size 40 mm dia,( ISI marked) complete all as specified and as directed.
Material and labour for taking down of ceiling fan of size 1200/1400mm for safety checking by replacing defective parts/painting/rewinding and re-fixing the ceiling fan after repairs, all as specified and as directed by Engr-in-charge. (Note:- The replacement of unserviceable items like capacitor, Bearings, Bush, Canopy, down rod and winding etc. shall be made as directed by the Engineer-in-Charge which will be measured and paid separately under respective items as Supply only. However, parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conduct of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) including cost of labour for above replacement are deemed to be inclusive in quoted rate all as directed.
Note:- The following items shall be deemed to be inclusive in the unit rate quoted against Sl Item No 134 (a) In each job, checking the functioning of fan including its connections, cleaning of fan, greasing of fan and mechanical check i.e. tightening of loose screw, nuts, bolts, etc are inclusive in unit quoted rate.
(b) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced, before commencement of work.
(c) Replacement of unserviceable parts like rubber bush, clamps, bolts, nuts, washers, safety pin, bearing etc will be paid under respective item here-in-after as supply only through proper documentation.
(d) The entire job will be carried out in Air Force stn Jalahalli
(e) Necessary T&P such as ladder, required manpower for taking down and refixing after repair shall be of contractor's responsibility.
(f) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
(g) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(j) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
(k) In case of minor defects, entire job shall be completed within12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
Supply only rotor of ceiling fan of any size complete all as specified and directed.
Supply only fan bearing suitable for ceiling fan 1200mm /1400 mm sweep (bearing with 8 balls shall be used ) Make:- NBC/TATA/SKF
Supply only 'U' clamp for hanging ceiling fan with all nuts, bolts and washers complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 45cm and not more than 60cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only Rubber reel bushes for ceiling fan of size 1200/1400mm complete all as specified and directed.
Supply only steel screw (for fixing of fan blade) as per site requirement for any make of ceiling fan complete all as specified and directed.
Supply only gun metal bush of suitable size for ceiling fan 1200mm /1400 mm sweep complete all as specified and directed.
Supply only fan canopies for ceiling fan size of 1200mm/1400mm complete all as specified and directed.
Supply only outer body of ceiling fan of any size complete all as specified and directed.
Supply only blades (made of aluminum) suitable for 1400mm sweep ceiling fan of any make with set of screws complete all as specified and directed.
Supply only safety pins 40mm to 50mm long with nuts and bolt with washers for ceiling fan of size 1200/1400mm complete all as specified and directed.
Supply only down rod for ceiling fan with 15mm dia (of length not less than 90cm and not more than 120cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply only blades (made of aluminum) suitable for 1200mm sweep ceiling fan of any make with set of screws complete all as specified and directed .
Supply only down rod for ceiling fan with 15mm dia (of length not less than 180cm and not more than 210cm) with hanging clamps for ceiling fan complete all as specified and directed.
Supply and fixing in replacement of unserviceable Ceiling fan 1200mm sweep, energy efficient ISI marked with star rating 230 Volts AC 50 Hz, single phase including provision of fixing arrangement, nut and bolt and suitable flexible copper cable not less than 0.5 m long complete writing MES No. with synthetic enamel paint complete all as specified and directed. Make : Havells/ Bajaj/ Orient Note:- (a) Old Unserviceable ceiling fan shall be deposited to MES store yard by the contractor.
Refixing existing serviceable ceiling fans 1200/1400 mm sweep servicing, painting. of ceiling fan with one coat of synthetic enamel paint by spraying including greasing/oiling, filling cavities with filler after cleaning all dust etc. complete all as specified and as directed by Engineer-in-Charge. Note : cost includes for replacement of rubber bush ,hanging hook with new cotter pins etc
Taking down of exhaust fan any size/capacity after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling including replacement of parts of minor nature such as screws, lugs, insulation tape, nuts, bolts, washers etc after cleaning the metal surface, greasing/lubricant etc to make it functional and making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.5 Sqmm from ceiling rose/ connector fan (minimum 0.50 Mtr length) are deemed to be inclusive in quoted rate all as specified and as directed. Note:- (a) Rewinding, and materials to be replaced are measured separately.)
(b) The above job shall be carried out by a trained electrician having qualified in ITI ( electrician Trade), documentary proof of the education of tradesman shall be produced to Engr-in-Charge before commencement of work.
(c) Defective unserviceable part like fan bush, bearing etc. will be paid under respective item here-in-after as supply only through proper documentation.
(d) The entire job will be carried out in Air Force stn Jalahalli
(e) Necessary T&P such as ladder, helper shall be contractor responsibility.
(f) All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any extra cost to the department.
(g) Any fan found defective/not working shall be brought to AGE E/M store yard & re-fixed after repairing.
(j) In case of major defects, entire job shall be completed within 10 days from the date of registration of complaint, failing which penalty charges @100/- per day shall be recovered.
(k) In case of minor defects, entire job shall be completed with 12 hrs from the time of registration of complaint, failing which penalty charges @ 50/- per job shall be recovered.
Supply only 3.15 mfd capacity exhaust fan condenser complete all as specified and directed.
Supply only fan bush of suitable size for exhaust fan of the any sweep complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 250mm sweep including greasing complete all as specified and directed.
Supply only 2.5 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 250mm sweep complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 300mm sweep including greasing complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 300 mm sweep complete all as specified and directed.
Supply only fan bearing of suitable size for exhaust fan of 450mm sweep including greasing complete all as specified and directed.
Supply only 4 mfd capacity ceiling /exhaust fan condensers complete all as specified and directed complete all as specified and directed.
Supply only metal louvers of suitable size for exhaust fan of the 450 mm sweep complete all as specified and directed.
M&L for cutting of hole through stone wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.
Supply and fixing Exhaust fan 250 mm sweep with louvers, copper winding 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Material and labour for winding of Exhaust fan 250 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
M&L for cutting of hole through brick wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.
Supply and fixing Exhaust fan 300 mm sweep with louvers, copper winding 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Material and labour for winding of Exhaust fan 300 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
M&L in repair for stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/wooden beading fixed on wall including necessary fixing arrangement up to height 11 mtr complete all as specified and directed. Note : All safety measures shall be the responsibility of the contractor
Supply and fixing Exhaust fan 300 mm sweep with blades, frame and louvers 230/ 240 volt AC single phase Metal body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Material and labour for winding of Exhaust fan 450 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 250 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Supply and fixing Exhaust fan 450 mm sweep with blades, frame and louvers 230/ 240 volt AC single phase Metal body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make-Havells /bajaj/ Crompton Greaves. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
Taking down of wall mounted/Pedastal fan of size 400/450mm after disconnecting cable connection, and refixing same in original position after necessary repair/over hauling . (Note:- Repair, rewinding, over hauling and materials to be replaced are measured separately.)
Supply only fan bush of suitable size for wall mounted/Pedastal fan of the any sweep complete all as specified and directed.
Supply only fan bearing of suitable size for wall mounted/Pedastal fan of 400 mm sweep complete all as specified and directed.
Material and labour for winding of wall mounted fan 400 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of sizenot less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Material and labour for winding of wall mounted/Pedastal fan 450 mm sweep of any make with super enamelled copper winding wire of existing gauge (wt of copper winding wire per fan 350 to 500 gms) including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections with twin core copper flexible wire of size not less than 0.75 mm of length not more than one meter with each fan complete all as specified and directed. Note :- (i) Old burnt wire shall be contractor’s property and necessary credit shall be recovered as per credit schedule.
Taking down carefully copper/aluminum point wiring (light, fan, Power) complete fittings such as switches , ceiling roses pendents , regulators sockets light fittings etc and making good disturbed surface of wall, floors , roof etc all as specified and directed.
M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealed rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & maching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame , concealed in wall and 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/Havells Note: Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
All as per item No. 323 here in before but for one light point controlled by one way switch.
All as per item No. 323 here in before but for one Exhaust fan/ceilling fan controlled by one by one way switch.
All as per item No. 323 here in before but for one bell point controlled by one bell push.
All as per item No.323 here in before but for one 3 pin socket outlet 5/6 Amp on the same board
All as per item No. 323 here in before but for one switch socket outlet 3 pin 5/6 Amps on independent board
All as per item No. 323 here -in - before but for One light point controlled by two, two way switches.
All as per Sl No 323 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor (FRLS) controlled by one 15/16A switch socket independently complete all as specified and directed.
Supply and Fix switch piano flush type 5/6 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 15/16 Amps 240 volts complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 5/6 Amps 240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 5/6 Amps 240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered socket outlet 3 pin 5/6 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered switch socket outlet 3 pin 5/6 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5/6 and 15/16 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian
S&F fan regulator stpped type electronic for ceiling fan complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth and getting out insoft/lose soil , complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed.
Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.
Material and labour for well burnt bricks ‘B’ class as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed. (iii) Removing excavated material out side MD land. (iv) Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Supply only of GI pipe light grade for cable protection of size 50 mm bore with fittings, complete all as specified and directed.
Material and labour for Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including supply of HDPE pipes upto 50 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed.
Taking down of old U/S UG cable of any type and any size complete all as specified and directed.
Material and labour for 4 core 16 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 16 Sqmm to 25 Sqmm, complete all as specified and directed.
Supply, installation, commissioning and testing of floor mounted, free standing OEM made type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of CPRI approved IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color temp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20 mm graded aggregate for bedding upto a height of 45 CM above ground level, including dismantling and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed and comprising of the following:-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KA - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amp, 16 KA - 03 Nos. (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (f) Space for spare feeder - 01 No. Note :- (i) The contractor shall submit CPRI approved IP65 certificate and all type test reports of polycarbonate modular enclosure as per norms mentioned above in BOQ alongwith the make approval. (ii) The Contractor shall submit the drawing for approval of GE before executing the work. (iii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
M&L in repair Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit, including taking down old u/s earth pit cover, complete all as specified and directed.
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip of any description, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.
Taking down of old U/S submain wiring of any type complete all as specified and directed.
S&F Sub main wiring with 2 runs of single core, 4 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 4.00 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. (Note : Two runs of cable and one run of earth wire including PVC conduit/casing capping shall be measured as one run length) Make : Havells, Polycab, Plaza
S&F factory made powder coated distribution board VTPN, 4 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB with fitting fixture complete all as specified and directed. Make : Indoasian/ Havells/ Legrand.
S&Fdistribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian
Taking down of old U/S earth enclosure with MCB any type complete all as specified and directed.
S&F of Single pole and neutral enclosure with a two pin and earth plug and socket with single pole MCB 32 Amps complete all as pecified and directed. Make Legrand /Schneider /ABB
Taking down of old U/S MCB DB TPN any type complete all as specified and directed.
S&F factory made powder coated distribution board TPN, 4 way double door MCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete complete all as specified and directed. Make : Indoasian/ Havells/ Legrand.
S & F TPN, MCB 40 to 63 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including rigid non metalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & matching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame, concealed in wall and 1.5 sq mm multi stranded copper conductor FRLS cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/Havells Note: Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
All as per item No. 384 here in before but for one light point controlled by one way switch.
All as per item No384 but for One ceiling fan /exhaust point controlled by one switch one way 5/6 Amps and fan speed regulator
All as per item No. 384 here in before but for one bell point controlled by one bell push.
All as per item No. 384 here -in - before but for One 2/3 pin switch socket point controlled by 5/ 6 Amps switch on Independent board.
All as per item No 384 but for One socket outlet point 5/6 Amps 3 pin on same board.
All as per item No. 384 here -in - before but for One light point controlled by two, two way switches.
All as per item No.384 here -in - before but for One 3 pin switch socket outlet combination, 15 Amps, with cables 4 sq mm all as specified and directed.
Supply and Fix modular switch 1 way 5/6 Amp,1 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular switch 1 way 15/16 Amp,1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular Socket,5/6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular Socket, 5/15/ and 6/16A - 3/5 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular switch 2 way 5/6 Amp, 1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular bell push 5/6 Amp,1 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian
S&F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directed.
Supply & fix of ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and as directed.
Taking down of old switch /shocket /regulator/ bell push complete all as specified and directed.
S&F Sub main wiring with 2 runs of single core, 6 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling etc including 6.00 Sqmm PVC insulated, unsheathed, single core, multistranded, copper conductor as earth continuity wire complete as specified and directed. (Note : Two runs of cable and one run of earth wire including PVC conduit/casing cappingshall be measured as one run length) Make : Havells, Polycab, Plaza
Taking down of old U/S MCB DB SPN with MCB any type complete all as specified and directed.
S&F factory made powder coated distribution board SPN 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S&F factory made powder coated distribution board SPN 6 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S&F factory made powder coated distribution board SPN 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S&F factory made powder coated distribution board SPN 12 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F MCB SPN 240 volts upto 40 Amps 'C' series 10 KA breaking capacity complete fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian.
S & F MCB SPN 240 volts 63 Amps 'C' series 10 KA breaking capacity complete complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian.
S & F MCB single pole 240 volts upto 40 Amps 'C' series 10 KA breaking capacity complete complete all as specified and as directed.Make : Legrand/ L&T/ Indo Asian.
Note :- An amount of Rs 1,77,953.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
stage.html
html • 0.07 MB
technical_845727.pdf
techsummary_845727.pdf
finance_845727.pdf
BOQ Comparative Chart
xlsx
finsummary_845727.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
8301GENPAGE.pdf
Tender Documents • 0.55 MB
BOQ_845727.xls
BOQ • 0.56 MB
8301PS.pdf
Additional Documents • 0.90 MB
Download all tender documents and submit your bid