Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-Finance | L1 | Accepted-Finance Ok | |
| 2 | L2₹2.9 L+₹6,150.98 (2.20%)Accepted-Finance | L2 | Accepted-Finance Ok |
Tender Value
Refer Docs
EMD Value
₹5,700
Closing Date
21 Dec 2021, 1:00 pmClosed
EE EnM HP I
DELHI JAL BOARD GOVT OF NCT OF DELHI OFFICE OF THE EXECUTIVE ENGINEER EnM HP I HAIDERPUR WATER WORKS DELHI 110085
Improvement of power factor by renovation of APFC panel installed at filter house at Bawana WTP.
2021_DJB_212740_8
NIT 18
Open Tender
Miscellaneous Works
Item Rate
30 days
Haiderpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹5,700
Yes
24 Dec 2021
14 Dec 2021
21 Dec 2021
14 Dec 2021
21 Dec 2021
14 Dec 2021
Dismantling of defective components like capacitors, relays, MCB, contactors, indication lights, panel locks, from APFC panel, including dismantling of terminations, control and power wirings, hardware and various rusted parts etc. as required at site
Supply of Heavy duty Round type capacitors of various capacities rated at 440V, 50 Hz, 3 phase AC complete with terminal cover and discharge device to replace defective capacitors in APFC panels as per requirement of each stage of the panel -make standard
Banking of capacitor units to form banks of suitable capacity by interconnection with necessary links/wires etc. as required at site to form capacitor banks of suitable rating as per requirement of individual stage to avoid frequent switching of capacitor banks and increase life of capacitors by reducing switching operations
Supply of microprocessor based APFC relay with digital display of power factor and other parameters for replacement of defective APFC relay of capacitor panel having 12 Steps for giving signal to contactor coils for switching ON and OFF required number of capacitor banks of suitable rating to achieve target power, control voltage of APFC relay is 230 V and CT secondary ration is 5A -make STANDARD
Supply of panel locks for replacement against the defective broken locks resulting in ill-fitting of panel door and risk of moisture and vermin ingress in to the panel
Supply of MNX-70 contractor with equivalent capacity contactor in replacement of defective contactor for switching of capacitor bank on receipt of signal from APFC relay-make L&T/Schneider/Havells
Supply of MNX-32 contractor with equivalent capacity contactor in replacement of defective contactor for switching of capacitor bank on receipt of signal from APFC relay-make L&T/Schneider/Havells
Supply of MNX-25 contractor with equivalent capacity contactor in replacement of defective contactor for switching of capacitor bank on receipt of signal from APFC relay-make L&T/Schneider/Havells
Supply of 1.5 mm sq. multistrand copper wire for replacement of burnt-out control wiring of various control circuits
Supply of 10 mm sq. multistrand copper wire for replacement of burnt-out power wiring of various power circuits
Supply of TP MCB up to 32 A rating for replacement of defective MCB for protection of capacitor bank in each stage in APFC panel -make L&T/Havells/Schneider
Supply of TP MCB up to 63 A rating for replacement of defective MCB for protection of capacitor bank in each stage in APFC panel -make L&T/GE/Schneider
Supply of LED type Indication lights of various colours for indication of status of capacitor banks in replacement of defective lights- make FTC/Standard
Installation, of all components and termination of incoming/outgoing connections with copper wires, lugs tapes etc. and using necessary hardware for proper fitment of all components to ensure compatibility with the existing one as per available space as required at site
Servicing of APFC panels including complete dusting of the panel, cleaning of contact points, Decarbonising of joints, alignment of doors, checking of all nuts & bolts control circuit and power circuit wiring dressing and renovation of control and power terminations with lugs tapes etc. as required at site
Testing & commissioning of APFC panel as per required parameters including following i. Programming of APFC relay for target power factor ii. Meggaring of all equipment for phase to phase, Phase to neutral and phase to earth. iii. All function tests iv Monitoring of power factor during warranty period
STANDARD CAPACITORS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .