| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.9 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Accepted due to L1 | |
| 2 | L2₹48.0 L+₹7.0 L (17.2%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC higher rate |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
21 Mar 2022, 6:00 pmClosed
GE NEW DELHI
GE NEW DELHI
CA NO GE/ND82/202122 REPAIR/MAINT OF EXTERNAL WATER SUPPLY AND EXTERNAL ELECTRIC SUPPLY AT NAVY AREA UNDER GE NEW DELHI
2022_MES_509090_1
GE/ND-82/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE NEW DELHI
Refer tender documents
7 documents required · 7 mandatory
₹500
GE NEW DELHI
₹94,000
Yes
31 Mar 2022
18 Feb 2022
24 Mar 2022
18 Feb 2022
21 Mar 2022
7 Mar 2022
Amount
S&F in replacement of Brush suitable for suction head 2' length complete all as specified and directed by Engr-in-charge.
M&L for repair for repair/maint/servicing to suction sweeper 2 HP cap including carrying the same to the workshop opening the pump and replacing the bearing , ring,gland packing , impeller complete and making the sweeper functional in all respect complete all as specified. Note : Rewinding of motor shall be measured and paid separately.
M&L for rewinding of motor 2HP to 3HP with super enamelled winding copper wire of existing size/gauge after cutting of buried winding including all insulation material such as insulation varnish , PVC copper cable lead glass fiber sleeves cotton tape insulation paper and heating in heat chamber at appropriate temp complete all specified and directed.
S&F in replacement flexible PVC heavy duty suction pipe of size 40mm as per sample all as specified.
S&F in replacement float ball PVC 8" (200mm dia) as per sample all as specified.
Repair/maintenance/ servicing to 3 phase electric driven air compressor with motor of capacity 5 HP (Make: EVEREST BLOWER) for filtration plant after disconnecting the electrical connection , dismantling, the compressor and motor from foundation taking to the civil workshop and carry out the repair by replacing compressor bearing gland packing , nut bolt and washer including necessary greasing , oiling , machining work for its smooth bringing back/fixing at its original position and testing complete including painting the complete set with 2 coat of synthetic enamel paint of approved colour complete all as specified and directed by Engr -in charge ( Rewinding of motor shall be measured and paid separately )
M&L for rewinding of 5.0 HP motor with super enamelled winding copper wire of existing size/gauge after cutting of buried winding including all insulation material such as insulation varnish , PVC copper cable lead glass fiber sleeves cotton tape insulation paper and heating chamber at appropriate temp complete all as specified and directed
Supplying, injecting and mixing of alum sulphate in swimming pool through dozing system installed complete all as specified and directed by Engr-in-charge.
Supplying, injecting and mixing of soda ash in swimming pool through dozing system installed complete all as specified and directed by Engr-in-charge.
Supplying, injecting and mixing of TCC A90 in swimming pool through dozing system installed complete all as specified and directed by Engr-in-charge.
Supplying, injecting and mixing of copper sulphate in swimming pool through dozing system installed complete all as specified and directed by Engr-in-charge.
Supplying, injecting and mixing of HCL in swimming pool through dozing system installed complete all as specified and directed at site.
Supply and filling AQUAFIT brand calcium hypochlorite 65% to 70 % chlorine content (in drum) the form of granular and tablet complete all as specified and directed.
M&L for isolation of power supply from the existing electric panel , Lifting of submersible pumping set of any capacity from deep bore well of any depth with chain and pulley arrangement ,transportation of submersible pump set to civil workshop,returning back of pump set on site after repair work completed and lowering down the submersible pump set Complete all as specified and directed.
S&F in replacement nuts, bolts, rubber gasket complete set complete all as specified and directed by Engineer-in-charge. Note :One job shall be inclusive of all nuts, bolts, washers and rubber gasket required for lifting/lowering of pipe line for one pumping set complete all as specified and directed by Engineer-in-charge.
M&L complete overhauling/repair of defective submersible pump/sewage pump of 5 HP to 7.5 HP ,dismantling of UNSV motor from pump set and opening the pump including cleaning of all parts, oiling/greasing, replacing of unserviceable parts such as CI connection piece,CI stage bowl,GM neck ring, remelting of GM impeller turning,GM DOL bush,SS stud with nut,water seal, revolving disc,EPV impeller,impeller key,repairing of stamping of stator,CI DOL piece,SS coupling with key,CI suction Piece.GM sand guard and any other parts of pump of capacity 5HP to 7.5 HP, 3 phase motor driven (excluding motor winding) cast iron/cast steel body complete and connecting with motor portion complete all as specified and directed.
M&L complete overhauling/repair of defective submersible pump/sewage pump of 10HP to 12.5 HP ,dismantling of UNSV motor from pump set and opening the pump including cleaning of all parts, oiling/greasing, replacing of unserviceable parts such as CI connection piece,CI stage bowl,GM neck ring, remelting of GM impeller turning,GM DOL bush,SS stud with nut,water seal, revolving disc,EPV impeller,impeller key,repairing of stamping of stator,CI DOL piece,SS coupling with key,CI suction Piece.GMsand guard and any other parts of pump of capacity 5HP to 7.5 HP, 3 phase motor driven (excluding motor winding) cast iron/cast steel body complete and connecting with motor portion complete all as specified and directed.
M&L in replacement of re-winding of motor of submersible pump /sewage pump set of capacity 5HP to 7.5 HP with suitable size copper conductor wire after cutting of existing burnt winding including replacement of unserviceable parts such as GM bearing,Rotor sleeve,water seal,thrust bearing segment,thrust bearing counter,thrust plate,T-bolt,submersible cable jointing kit,revolving disc,Rotor sleeve,impeller,distance sleeve,guide bush,DOL sleeve,O ring,motor seal,CI lower housing and upper housing, diffuser,all insulating materials such as insulation varnish, PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper and heating in heat chamber at appropriate temperature complete all as specified & directed.
M&L in replacement of re-winding of motor of submersible pump/sewage pump set of capacity 10 HP to 12.5 HP with suitable size copper conductor wire after cutting of existing burnt winding including replacement of unserviceable parts such as GM bearing,Rotor sleeve,water seal,thrust bearing segment,thrust bearing counter,thrust plate,T-bolt,submersible cable jointing kit,revolving disc,Rotor sleeve,impeller,distance sleeve,guide bush,DOL sleeve,O ring,motor seal,CI lower housing and upper housing, diffuser,all insulating materials such as insulation varnish, PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper and heating in heat chamber at appropriate temperature complete all as specified & directed.
M&L for isolation of power supply from the existing electric panel , Lifting of sewage pumping set of any capacity from deep sewage well of any depth with chain and pulley arrangement ,transportation of sewage pump set to civil workshop,returning back of pump set on site after repair work completed and lowering down the pump set Complete all as specified and directed.
M&L for isolation of power supply from the existing electric panel, taking out unserviceable booster pump set of cap 12.5 HP by unscrewing of bolts of pumpset casing from MS base frame and keeping aside , transportation of booster pump to civil workshop, dismantling of UNSV pumpset in including cleaning of all parts, oiling/greasing including reassembling the same after repair , and back to site, fixing of repaired booster pump set on its original foundation making proper alignment , including restoration of power supply and testing, commissioning to the entire satisfaction of Engr-in-Charge.
M&L for isolation of power supply from the existing electric panel, taking out unserviceable booster pump set of cap 25 HP by unscrewing of bolts of pumpset casing from MS base frame and keeping aside , transportation of booster pump to civil workshop, dismantling of UNSV pumpset in including cleaning of all parts, oiling/greasing including reassembling the same after repair , and back to site, fixing of repaired booster pump set on its original foundation making proper alignment , including restoration of power supply and testing, commissioning to the entire satisfaction of Engr-in-Charge.
M&L for isolation of power supply from the existing electric panel, taking out unserviceable booster pump set of cap 100 HP by unscrewing of bolts of pumpset casing from MS base frame and keeping aside , transportation of booster pump to civil workshop, dismantling of UNSV pumpset in including cleaning of all parts, oiling/greasing including reassembling the same after repair , and back to site, fixing of repaired booster pump set on its original foundation making proper alignment , including restoration of power supply and testing, commissioning to the entire satisfaction of Engr-in-Charge.
M&L for rewinding of 12.5 HP booster motor with new super enamelled winding copper wire of existing size/gauge after cutting of burned winding including all insulating materials such as insulation varnish,bush, PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper,bearing sleeve,pump shaft welding,turning,grinding,making key way,TC coupling,CI impeller,CI interstage ring,gland packing,wear ring,bearing housing,fastener,air release valve,eye bolt,ball bearing,water liquid deflector,motor & pump coupling and heating in heat chamber at appropriate temperature complete all as specified and directed.
M&L for rewinding of 25 HP booster motor with new super enamelled winding copper wire of existing size/gauge after cutting of burned winding including all insulating materials such as insulation varnish, bush,PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper,bearing sleeve,pump shaft welding,turning,grinding,making key way,TC coupling,CI impeller,CI interstage ring,gland packing,wear ring,bearing housing,fastener,air release valve,eye bolt,ball bearing,water liquid deflector,motor & pump coupling and heating in heat chamber at appropriate temperature complete all as specified and directed.
M&L for rewinding of 100 HP booster motor with new super enamelled winding copper wire of existing size/gauge after cutting of burned winding including all insulating materials such as insulation varnish, bush,PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper,bearing sleeve,pump shaft welding,turning,grinding,making key way,TC coupling,CI impeller,CI interstage ring,gland packing,wear ring,bearing housing,fastener,air release valve,eye bolt,ball bearing,water liquid deflector,motor & pump coupling and heating in heat chamber at appropriate temperature complete all as specified and directed.
Taking out Manhole cover and Desludging the existing manhole septic tank including removing of Sludge/Mud/Muck, Desilting/Dechocking with combine high pressure water jetting cum suction (Vacuum) type machine mounted on LCV/HCV and disposed off outside MD land and blocking of the sewage line of septic tank to stop the entry of waste water/sludge/mud in sewage well.
M & L for disposal of waste water up to 06 feet depth of Sewage well and 04 Feet depth of Man Hole by using Portable sewage pumping set of capacity 7.5 HP and filling of waste water in a covered trolley and disposed off outside MD land all as specified and directed.
M & L for removal of Sludge/Mud/Muck/Waste material/Silt upto a depth of 14 feet , Desilting/Dechocking with high pressure super socker machine and cleaning of surface of sump of sewage well using wire brushes and other scrapping tools to remove dirt and scales to make it free from all deposits and disposed of the same to outside MD land all as specified and directed.
Opening of Manhole cover and connecting of the sewage line of septic tank with sewage well complete all as specified and directed by Engineer-in-charge.
M&L for development of tube well for improvement of water yield by 210 CFM compressor including taking out existing submersible pump set complete with pipe and cable and lowering the same after water yield improvement including necessary transportation and minor spare parts complete all as specified.
S&F in replacement of Cosmic Star Standard Automatic Star Delta Starter/controller for submersible / sewage/mono block pump set of capacity 12.5 HP comprising of item Single phasing preventor, overload relay,Auto/Manual Switch, Amp meter, voltmeter, ON/Off Push Button, Light indicator and other connected accessories in housing in Sheet steel enclosure including connection in existing system with cable and all arrangement complete all as specified and directed. Make:- Havells/ L&T/ Standard.
S&F in replacement of Cosmic Star Standard Automatic Star Delta Starter/controller for submersible / sewage/mono block pump set of capacity 10 HP comprising of item Single phasing preventor, overload relay,Auto/Manual Switch, Amp meter, voltmeter, ON/Off Push Button, Light indicator and other connected accessories in housing in Sheet steel enclosure including connection in existing system with cable and all arrangement complete all as specified and directed. Make:- Havells/ L&T/ Standard.
S&F in replacement of DOL Direct Online Starter suitable for submersible pump set/ mono block pump set of capacity 7.5 HP comprising of item Single phasing preventor, overload relay,Auto/Manual Switch, Amp meter, voltmeter, ON/Off Push Button, Light indicator and other connected accessories in housing in Sheet steel enclosure including connection in existing system with cable and all arrangement complete all as specified and directed. Make:- Havells/ L&T/ Standard.
S&F in replacement of DOL Direct Online Starter suitable for submersible pump set/ mono block pump set of capacity 5 HP comprising of item Single phasing preventor, overload relay,Auto/Manual Switch, Amp meter, voltmeter, ON/Off Push Button, Light indicator and other connected accessories in housing in Sheet steel enclosure including connection in existing system with cable and all arrangement complete all as specified and directed. Make:- Havells/ L&T/ Standard.
M&L for repair & maintenance of air curtain complete by replacing rewinding of motor with new super enamelled winding copper wire of existing size/gauge after cutting of burned winding including all insulating materials such as insulation varnish, PVC copper cable lead, glass fiber sleeves, cotton tape, insulation paper and heating in heat chamber at appropriate temperature including replacement of ball bearing, fan condenser including cleaning/servicing of air curtain complete all as specified.
S & F in replacement waterproof submersible copper cable flat 6 Sqmm 3 core for bore well of any depth with fitting and connections complete all as specified and as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall surface with MS clip or on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing as required 32x6 mm galvanised iron strip all as specified.
S&F in replacement of UNSV pump single phase 240 V, 50 Hz AC supply suitable for RO plant of capacity 50 to 70 ltr per hour. Make:- KELVIN/KENT/AQUA FRESH
M&L for servicing of RO Plant of capacity 50 to 80 ltr including replacement of UNSV membrane, carbon filter, sedimentation filter complete all as specified and directed by Engr-in-Charge. Make:- KELVIN/KENT/AQUA FRESH
S & F in replacement of GI water tubing, medium grade, galvanised (ISI marked as IS-1239), with all fittings including short lengths, fixed to walls, fixed in sewage well, U/G sump, concealed in wall and ceiling or laid in floor trench complete with all fittings (such as bends, elbows, flanges Tee, short pieces,reducer,nipple, connectors, back nuts, diminishing pieces, caps and plugs, unions etc), complete, all as specified and directed, of the following sizes:-
(a) 150 mm bore
(b) 100 mm bore
(c) 80mm bore
(d) 50mm bore
(e) 40mm bore
(f) 25mm bore
(g) 20mm bore
S&F in replacement of cast iron sluice valve, 100mm bore, hand wheel operated , non rising type with steel spindle complete with flanged ends and gun metal parts including necessary nut, bolts, washers and rubbers gaskets, 3mm thick, heavy duty and iron wheel all as per site requirement complete with jointing material including taking out old unserviceable sluice valve complete all as specified
S&F in replacement of cast iron Gate/sluice valve, 80mm bore, hand wheel operated ,non rising type with steel spindle complete with flanged ends and gun metal parts including necessary nut, bolts, washers and rubbers gaskets, 3mm thick, heavy duty and iron wheel all as per site requirement complete with jointing material including taking out old unserviceable sluice valve complete all as specified
S&F in replacement of non return valve, 150mm with flanged ends ,doors and discs cast integral cast hinge lugs to allow free door and disc operation without by pass arrangement, including necessary nut, bolt, washer and rubber gaskets, 3mm thick, heavy duty all as per site requirement including taking out old existing unserviceable non return valve of the size 150mm dia all as specified.
S&F in replacement of non return valve, 100mm with flanged ends ,doors and discs cast integral cast hinge lugs to allow free door and disc operation without by pass arrangement, including necessary nut, bolt, washer and rubber gaskets, 3mm thick, heavy duty all as per site requirement including taking out old existing unserviceable non return valve of the size 100mm dia all as specified.
S&F in replacement of non return valve, 80mm with flanged ends ,doors and discs cast integral cast hinge lugs to allow free door and disc operation and without by pass arrangement, ISI marked including necessary nut, bolt, washer and rubber gaskets, 3mm thick, heavy duty all as per site requirement including taking out old existing unserviceable non return valve of the size 800mm dia all as specified.
S&F in replacement of cast iron body butterfly valve, wafer type, gear operated with stainless steel disc of size 150mm, with integrally moulded rubber lining of silicon, double flange all as per site requirement complete all as specified.
S&F in replacement of cast iron body foot valve with strainer, single door, swing check type of size 150mm with all the material and components, flanged ends all as per site requirement complete all as specified .
S&F in replacement of cast iron body foot valve with strainer, single door, swing check type of size 100mm with all the material and components, flanged ends all as per site requirement complete all as specified .
S&F in repair 40 mm dia gate valve, gun metal, heavy duty screwed down both ends with iron wheel head after taking down old existing gate valve complete all as specified and directed at site.
S&F in repair 20/25 mm dia gate valve, gun metal, heavy duty screwed down both ends with iron wheel head after taking down old existing gate valve complete all as specified and directed at site.
Servicing of DG set 166.6 KVA of make KIRLOSKAR by taking out U/S spares, Cleaning by brushing to remove dust including cleaning of filter,Checking of all nuts, bolts tightening wherever necessary, check up engine oil level, coolant level and Labour for top up if necessary, adjustment belt tension,Tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking For smooth functioning of DG Set. Note :- 1. Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured paid for separately under respective items. 2. Minor spares like nuts,bolts etc cost up to Rs 200 shall be included in the rate quoted above.
M&L for"B" Check DG set 166.6 KVA of make KIRLOSKAR by taking out U/S spares, Cleaning by brushing to remove dust including labour for Changing engine oil l coolant etc to max level, adjustment belt tension,Tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking For smooth functioning of DG Set Note :- Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured and paid separately under respective items .
Supply in replacement Fan belt B-56, for DG set
Supply in replacement Air cleaner for DG set
Supply in replacement Diesel Filter for DG set
Supply in replacement Oil filter for DG set
Supply in replacement High pressure wire braided diesel pipe with benjo bolt 1 mtr long for DG Set
Supply in replacement Kirloskar Engine Oil 20W 40 Make: Castrol/HP /Equivalent
Supply in replacement Battery terminal gun metal as per sample
Supply in replacement Battery Lead of existing sizes
Supply in replacement Coolant ready mix Make: Castrol /Equivalent
Supply in replacement Relay 24V, 11 pin with base for AMF Panel Make – PIC/ Teknika /Equivalent
Supply in replacement Under Voltage relay 415 VAC for AMF Panel Make – PIC/ Teknika /Equivalent
Supply in replacement Battery Charger 12 Volt DC,for AMF Panel Make:Teknika/Equivalent
Supply in replacement Single phase preventor VSP II for 3 phase motor
S&F in replacement of PVC float valve complete of size 40mm dia including necessary fittings/ fixtures all as specified.
S&F in replacement of battery 180 Ah,12 Volts maintenance free including battery terminal alongwith connecting wire of suitable gauge upto 2 mtr length min as required on site all as specified and directed by Engineer-in-Charge. Make:- Exide/Amaron/ Luminous.
M&L for construction of valve pit chamber of internal size 600x600x600mm depth with 230mm thick walls using sub class 'B' bricks, built in CM 1:6 including angle iron frame of size 40x40x6mm duly welded with 2 nos. hold fast made out of 100mm x 30mm x 3mm thick flat iron & MS sheet 16 gauge cover with suitable steel hinging arrangement, round bar 12mm dia MS handle for lifting, suitable locking arrangement & painting with 2 coats of black bituminous paint over a coat of red oxide primer, internal and top surfaces of pit plastered with 15mm thick CM 1:4 and external surfaces to be flushed in the same mortar as the work proceeds, 75mm thick PCC 1:3:6 using 40mm graded stone aggregate as in foundation extended 75mm on either side from external face of brick walls, 50mm thick PCC 1:2:4 using 20mm graded stone aggregate laid in floor of pit complete all as specified and directed by Engr-in-Charge.
All as per above item No. 76 but the internal size of 900x900x1200mm
All as per above item No. 76 but the internal size of 1200x1200x1200mm
M&L for cleaning of RCC underground water sump of approx capacity upto 455000 Ltrs by removing the mud/settled bleaching powder and all other foreign material from the sump and depositing where directed but not less than 50 mtr from the starting point including scraping / removing all dirt/scales from the internal wall of the sump and washing the bottom surface and wall surface of the sump with clean water, draining out the dirty water so that the whole sump be thoroughly cleaned after pumping out all existing water by portable centrifugal/mono block submersible pumping set, applying one coat of bleaching powder on the all inner wall surface of sump including bottom surface and writing the date of cleaning on the sump complete all as directed at site by AGE E/M New Delhi.
Supply, installation, testing & commissioning of digital water level monitoring system at UG sump with innovative piezo-resistive linear sensor non ambiguous display 3 ½ digit (1999 counts maximum) unit options: any two of Cm, Ltr/Kltr, % (percent), resolution: 0.1 for % and 1 Cm upto 20 Mtrs deep tank DATUM: level adjustable power: 10-14 VDC (5 watts) temperature: 0-550 Celsius Relay: NO-230 VAC, 6 Ampere sensor on tripod stand no electrical contact with water no-long-term effect of salinity on sensor complete with followings:- (a) Wall hanging bracket IPX2 enclosure 420mmx210mmx240mm. (b) SMPS power adaptor (5 watts). ( c) 12V/220 volts input hooter facility. (d) Audible alarm facility. Make: IPC (IPCDLLMS) / Kratos (KELMS100).
S and F three core pvc copper cable of size 2.5 sqmm, 1100 volts grade, shieled complete all as specified.
S and F rigid non-metallic PVC conduit medium grade of size 20 mm dia complete with fixing saddles, tee, bends, elbows all as specified.
Comprehensive, preventive and periodical maintenance of washer extractor (03 Nos) of capacity 30 Kg per charge Make: STEFAB/FEBCARE installed at NOM-Varuna in reliable, safe and efficient manner by regular examining, lubricating and adjusting the mechanical and electrical driving equipment including replacement of defective / spares parts as "Supply only" and testing on completion to the entire satisfaction of Engr-in-charge complete all as specified. Note:- (i) The contractor shall have MOU for providing service and material with Laundry plant manufacturer, M/s STEFAB, FEBCARE. (ii) Spare parts to be replaced as listed in sch 'A' to be measured and paid separately as supply only. Fixing charge is deemed to be included in item No. 83. (iii) All the complaints will be rectify within 24 hrs from the time of receipt of complaint. If contractor fails to rectify the complaint within 24 hrs from the time of receipt of complaint, the compensation / penalty of Rs 500.00 per complaint per day shall be recovered from the contractor's dues. (iv) Any items not covered under as supply only shall be deemed to be included in this section for the smooth functioning of laundry plant and the contractor may quote the rate accordingly. Contractor is expected to inspect the laundry plant at NOM Varuna before quoting the rate."
Supply only in replacement Programmable Logical Card (PLC) ST-6 type complete Make Stefab complete all as directed
Supply only in replacement of heating element 6KW, 440 Volts, 50Hz suitable for 30 Kg per charge Make:STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of thermostat suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of water solenoid valve 25 mm dia suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of V-Belt of sizes suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of main water inlet valve suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of main drain valve suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of filter regulator suitable for 10 bars maximum pressure & 0.5-10 bars pressure range suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of lubricator suitable for 10 bars maximum pressure suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of PU tube of approx 2.00 meters length suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of VSP D-1 type suitable for 415 volts AC suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of pneumatic cylinder kit for FPE-150 suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of filter suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of flexible Hose pipe suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of ball bearing C040 of main shaft suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of gland packing with housing unit suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of main door glass toughened suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement of Digital Display Controller Unit suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified.
Supply only in replacement variable frequency drive suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified
Comprehensive, preventive and periodical maintenance of drying tumbler (02 Nos) of capacity 30 Kg per charge Make: STEFAB/FEBCARE installed at NOM-Varuna in reliable, safe and efficient manner by regular examining, lubricating and adjusting the mechanical and electrical driving equipment including replacement of defective / spares parts as "Supply only" and testing on completion to the entire satisfaction of Engr-in-charge complete all as specified. Note:- (i) The contractor shall have MOU for providing service and material with Laundry plant manufacturer, M/s STEFAB, FEBCARE. (ii) Spare parts to be replaced as listed in sch 'A' to be measured and paid separately as supply only. Fixing charge is deemed to be included in item No. 103. (iii) All the complaints will be rectify within 24 hrs from the time of receipt of complaint. If contractor fails to rectify the complaint within 24 hrs from the time of receipt of complaint, the compensation / penalty of Rs 500.00 per complaint per day shall be recovered from the contractor's dues. (iv) Any items not covered under as supply only shall be deemed to be included in this section for the smooth functioning of laundry plant and the contractor may quote the rate accordingly. Contractor is expected to inspect the laundry plant at NOM Varuna before quoting the rate.
Supply only in replacement Programmable Logical Card (PLC) ST-4 type complete all as directed. Make: Stefab
Supply only in replacement of contactor 4 pole 230 volts of capacity 40 Amps all as directed Make :L&T/C&S
Supply only in replacement of Digital Display Controller Unit suitable for 30 Kg per charge Make: STEFAB/FEBCARE drying tumbler complete all as specified.
Supply only in replacement of air filter suitable for 30 Kg per charge Make: STEFAB/FEBCARE drying tumbler complete all as specified.
Supply only in replacement of regulator suitable for 30 Kg per charge Make: STEFAB/FEBCARE drying tumbler complete all as specified.
Supply only in replacement of lubricator suitable for 30 Kg per charge Make: STEFAB/FEBCARE drying tumbler complete all as specified.
S&F in replacement of rubber packing suitable for 30 Kg per charge Make: STEFAB/FEBCARE drying tumbler complete all as specified.
Supply only in replacement of PU pipe suitable for 30 Kg per charge Make: STEFAB/FEBCARE drying tumbler complete all as specified.
Supply only in replacement of water solenoid valve size 25mm with diaframe inside suitable for 30 Kg per charge Make: STEFAB/FEBCARE drying tumbler complete all as specified.
Supply only in replacement of Automatic steam inlet valve suitable for 30 Kg per charge Make: STEFAB/FEBCARE drying tumbler complete all as specified.
Supply only in replacement of heating coil complete suitable for 30 Kg per charge Make: STEFAB/FEBCARE drying tumbler complete all as specified.
Supply only in replacement of main door glass toughened suitable for 30 Kg per charge Make: STEFAB/FEBCARE drying tumbler complete all as specified.
M&L for descaling of 300 LPD direct thermostat type solar panel including tank & flat plate collector (03 Nos) by applying descaling chemical and washing the same with fresh water complete all as specified.
M&L for descaling of 20 mm GI water pipe line by applying descaling chemical and washing the same with fresh water complete all as specified.
S&F in replacement of heating element 4 KW, 240 volts, 50 Hz suitable for solar water heating unit all as specified.
S&F in replacement of thermostat 20 Amps, 240 volts, 50 Hz suitable for solar water heating unit all as specified.
M&L for insulation to 20 mm GI pipe line network with 5 mm thick PUF thermal foam insulation sheet cut into pieces algorithm length, wrap around pipe and covered with self adhesive tape from tank/panel to all exposed portion upto tape including taking out old UNSV insulation complete all as specified & directed By Engr-in-charge.
Supply only in replacement of Oil Seal suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified
Supply only in replacement of Galon Rope suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified
Supply only in replacement of Inner Bearing suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified
Supply only in replacement of Sleave suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified
Supply only in replacement of Bolts suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified
Supply only in replacement of Table stand suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified
Supply only in replacement of Table switch suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified
Supply only in replacement of Grease suitable for 30 Kg per charge Make: STEFAB/FEBCARE washer extractor complete all as specified
S&F in replacement Off load Changeover Switch - AC 23 (side handle) in sheet enclosure, 415 Vac, 50 Hz. 4 pole 200 Amp/415 volts on load side handle operated type including taking down old change over complete all as specified and directed. Make: Havells/L&T/Standard.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanised iron strip 25x4 mm by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to starter panel all complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement of old unserviceable overload relay suitable for 25 HP motor and connected internal wiring complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable contactor suitable for 25 HP motor and connected internal wiring complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable single phase preventor and connected internal wiring suitable for 25 HP motor starter complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable phase sequence corrector relay 440V , 50 HZ Supply suitable for 25 HP motor starter and connected internal wiring complete all as specified and directed by Engineer -In- Charge. Note:- The rate is inclusive of connection out the starter and make the connection after replacement of relay.
S & F in replacement of old unserviceable indication lamp in R,Y,B colour and connected internal wiring for motor starter complete all as specified and directed by Engineer-In-Charge.
S & F in replacement of old unserviceable Rotary switch and connected internal wiring for motor starter complete all as specified and directed by Engineer-In-Charge.
S & F in replacement of old unserviceable push button and connected internal wiring for motor starter complete all as specified and directed by Engineer-In-Charge.
S&F in replacement Off load Changeover Switch - AC 23 (side handle) in sheet enclosure, 415 Vac, 50 Hz. 4 pole 400 Amp/415 volts on load side handle operated type including taking down old change over complete all as specified and directed. Make: Havells/L&T/Standard.
Excavating in trenches in any type of soil n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in any type of soil complete all as specified and directed by Engr-in-charge.
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified and directed by Engr-in-charge
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for laying of LT under ground cable/ GI pipe complete all as specified
Returning filling including spreading, levelling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified.
Removing excavated materials to a distance not exec. 50 mtr and deposing where directed at a level not exec 1.5 mtr above the starting point all as specified.
M&L for Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and as directed
Laying only serviceable sub class ‘B’ bricks as retrieved from Srl item No 10 complete all as specified and directed by Engr-in-Charge.
Supply & Laying in replacement of XLPE LT cable 1100 volts grade heavy duty with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC Tape armoured with galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS-7098 (Part-I) with latest amendments laid in tranches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-Charge of the following size:-. Note : Excavation , earth work, sand cushioning , brick protection and pipe shall be measured and paid separately under appropriate item of this schedule.
(a) 25 sqmm 3.5 core
(b) 35 sqmm 3.5 core
(c) 50 sqmm 3.5 core
(d) 70 sqmm 3.5 core
(e) 120 sqmm 3.5 core
(f) 185 sqmm 3.5 Core
(g) 240 sqmm 3.5 Core
Arranging fault locating machine to locate the fault in underground electric power cable of any length & any type of 11 KV/1.1 KV grade HT/ LT cables & pin point the fault, it also include testing of the cable after locating fault and cutting the cable at Fault to fix the joint including excavation and earth work in any type of soil complete Note :(i) Cable joint shall be measured and paid separately under respective of Sch 'A' (ii) If fault is not rectified within 24 hours after receiving message , the contractor shall be charged penalty for Rs 500/- per Hours & the same has been deduced from his account during RAR
Supply , fixing testing and commissioning in replacement of cable joint kit for 1.1 KV grade cable for straingt through joint heat shrinkable type joint complete with jointing material and accessories suitable for following size of XLPE/PVC aluminium conductor cable :-
(a) 25 to 35 Sq mm cable of 3.5/ 4 core size
(b) 50 to 95 Sq mm cable of 3.5core size
(c)120 to 180 Sq mm cable of 3.5 core size
(d)240 to 400 Sq mm cable of 3.5core size
Demolition of cement concrete (un-reinforced) in ground floor and paving thickness not exc. 15 cm (below or above ground level) for removal of LT underground cable/GI pipe of any size description and making good ( PCC 1:3:6) the same as per existing specifications after relaying new cable / GI pipe complete all as specified and as directed by the Engineer -in-Charge.
M&L for supply, erection, testing & commissioning of 8 metre high made out of 3 mm thick galvanized iron sheet hot dip octagonal street light pole in one segment with one longitudinal welding joint including galvanized MS sheet with window/door opening at 420 mm height from bottom with one MCB SP 16 Amps, 10 kA & TPN connector block 40 Amps having flash cover including necessary earth work (excavation, returning filling & removal) in soft/loose soil, RCC (grade M20) in foundation as per recommended design of manufacturer considering safe soil bearing capacity at site including suitable size & minimum 04 Nos foundation bolts of minimum dia 22 mm & 750 mm long "J"-type alongwith nuts, washers, anchor plates and templates, 50 mm dia PVC pipe in foundation for entering cable complete including dismantling of PCC pole all as specified. The foundation details shall be as under:- (a) RCC foundation size below GL will be 600 mm x 600 mm x 1300 mm (depth) (minimum) and above GL shall be 300 mm high of same section. (b) Main reinforcement in RCC shall be 20 mm dia 8 Nos TMT steel bars in vertical and stirrups of 8 mm dia @ 190 mm c/c. ( c) Base plate and anchoring plate shall be of minimum size 225 x 225 x 16 mm thick. (d) RCC (grade M20) in foundation. (e) Anchoring bolts shall be of "J"-type 750 mm long and 22 mm dia MS rod. Note: Foundation drawing of manufacturer of pole shall be approved by GE before execution of work at site. Make: Cat Pt No. HM-1109P of Crompton Greaves or equivalent in L& T/schneider
S&F of single arm bracket of minimum length 1.00 mtr, 40 mm (OD) ERW pipe duly fixed with 300 mm long pole cap suitable for 8 mtr high octagonal street light pole complete all as specified.
S&f In replacement of MCCB, 4 pole, 415 volt of capacity 100 amp, Ics=100% Icu, adjustable thermal setting 80-100% with breaking capacity 16 KA all as specified
All as per Srl item No. 166 here-in-before but 125 Amps breaking capacity not less than 16 KA
All as per Srl item No. 166 here-in-before but 160 Amps breaking capacity not less than 36 KA
All as per Srl item No. 166 here-in-before but 250 Amps breaking capacity not less than 36 KA
All as per Srl item No. 166 here-in-before but 630 Amps breaking capacity not less than 50 KA
All as per Srl item No. 166 here-in-before but 3 Pole 63 Amps breaking capacity not less than 16 KA
All as per Srl item No. 166 here-in-before but 3 Pole 100 Amps breaking capacity not less than 16 KA
All as per Srl item No. 166 here-in-before but 3 Pole 160 Amps breaking capacity not less than 36 KA
All as per Srl item No. 166 here-in-before but 3 pole 200 Amps breaking capacity not less than 36 KA
All as per Srl item No. 166 here-in-before but 3 pole 250 Amps breaking capacity not less than 36 KA
All as per Srl item No. 166 here-in-before but 3 Pole 400 Amps breaking capacity not less than 36 KA
S&F in replacement MCB TPN/ Isolator 4P from 40 Amps 415 volts, 'C' Series 10 KA as per site requirement and as directed of approved make. Make : Legrand/ABB/Crabtree
S&F in replacement MCB TPN/ Isolator 4P from 63 Amps 415 volts, 'C' Series 10 KA as per site requirement and as directed of approved make. Make : Legrand/ABB/Crabtree
S&F in replacement MCB TPN/ Isolator 4P from 100 Amps 415 volts, 'C' Series 10 KA as per site requirement and as directed of approved make. Make : Legrand/ABB/Crabtree
S&F in replacement MCB TP 3P from 63 Amps 415 volts, 'C' Series 10 KA as per site requirement and as directed of approved Make : Legrand/ABB/Crabtree
S&F decorative LED type post top lanterns luminaire 40 watts, out door type for 360 degree indirect light with resistant to corrosion, glare free having better uniformity complete with suitable driver all as specified. Make:Cat pt No. LPTO-40/CDL of Crompton Greaves make or equivalent in Philips/Havells
S&F LED bollard luminaire 10 watts, inverted pyramid tripod type with soft 360 degree light out door type having resistant to corrosion with better optics for uniform distribution complete with suitable driver & fixing nuts, bolts & washers all as specified. Make: Cat pt No LBLSN-10CDL of Crompton Greaves or equivalent in Philips/Havells
S & F LED flood light luminaires 90 watts, 230 volts AC, out door type with pressure die cast housing resistant to impact and corrosion, glare free complete with lamp, driver complete all as specified. Make: CG cat pt No.LFLN-90-CDLL or equivalent in Philips/Havells .
S&F in replacement of LED fountain light luminaire 1x9 watts, ,underwater type , adjustable type IP 67 type complete with stainless steel housing toughened glass LED Lens as of approved colour temperature including fixing on existing surface with including suitable nuts , bolt& washer and making proper electrical connection complete all as specified
S&F in replacement of LED Security light fitting 120 Watt Highly efficient made of pressure die cast aluminium housing with lens & toughened glass in replacement of old unserviceable conventional security light fitting including fixing material ie MS clamp, Nut and bolt,anchor fastener washer etc complete all as directed . Make:Havells/CG/Philips
S&F LED flood light luminaires 135 watt , 230 volt AC, out door type with pressure die cast housing resistant to impact and corrosion, glare free complete with lamp, driver complete all as specified. Make:Philips/Havells/CG
S & F in replacement of ornamental street light 120 Watt, 230 Volt AC ,outdoor type with spun aluminium designer housing with clear acrylic for city beautification with IP 65 protection all as specified and directed by Engineer-In-Charge Make: Cat No HLOSL-04-120-CWL or equivalent model in CG/Havells/Philips.
S&F in replacement of LED driver having input voltage as 200-260 Volts AC 50 HZ & output voltage as 12 Volt DC Suitable upto 120 watt LED Fitting driver fixed in & suitable size thermoplastic box having IP protection complete including making proper electric connection complete all as specified.
S&F in replacement of machined cast bronze natural finish fountain nozzle 15 mm PF 3452 type with cascade complete as specified Make : Aquascape /Sant
M&L for painting of steel tubular pole after Cleaning and scraping with wire brush complete with two coat of aluminium paint over a coat of red oxide primer and applying one coat of cement base paint on PCC coping complete all as directed
M& L for Painting of LT Panel of any sizes after cleaning and scraping old paint with wire brush with two coat existing paint over a one coat of red oxide primer by using spray gun and applying one coat of cement base paint on PCCfoundation complete all as directed
S & F in replacement of Integral aviation obstruction light luminaires comprising of aluminium housing with polycarbonate encloser including 230 volts, 50 Hz red coloured complete with all fixing accessories including minimum 01 RM medium grade GI tube of 25 mm bore with suitable reducer & suitable PCC foundation and all standard accessories all as specified. Make: Bajaj/Philips/Wipro.
Taking out complete 8 Mtr street light pole along alongwith street light fitting from existing site and refixing the same pole with new foundation concrete , including grouting with new nut bolts, and refixing/reconnecting the street light after completion of fixing of pole work complete all as specified and directed by Engr-in -Charge
S&F in replacement cable PVC insulated, multi stranded, unsheathed 1100 volts, three core copper conductor of size 6.0 sqmm drawn in pole/post/conduit all as specified.
S & F of angled Gi Bracket for fixing of building security light including clamps,Nut,Bolts complete all as specified & directed
Comprehensive maintenance for checking of Door sensor at ABHM including maintaining the functionality each month & all the spare parts complete all as specified & directed.
M & L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25X4 mm up to 7.50 RM bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board / test point at the other and watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh etc including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil all as specified.
Material and labour for design, development, commissioning & testing EHCC certified ground tubular effective earthing system to give earth resistance less than 2 ohm ,hollow tube solid bar (CPRI tested for 15 kA current capacity for LT line) highly anticorrosive long life electrode with and including adequate protective coating to withstand severe wear conditions in the earth pit and of size std medium grade GI tube outside secondary conductor of 80mm dia and main primary conductor inside of 25x6mm copper strip 3000mm length ready to install with suitable connecting terminal confirming to IS: 3043:1987 specification highly conductive packing material to be filled in earth pits for providing uniform low resistivity anticorrosive hygroscopic medium around the earth system for improving the efficiency of current dissipation 25 Kg per bag (3 bag per kit) min or sufficient quantities required as per site complete including main copper earthing lead of size 25x6 mm up to 7.50 metre to connect with equipment and including PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate pit chamber with FRP pit cover of size 0.30x0.30x0.30m and cutting of rocks if available at site in a rocky area including necessary earth work in any type of soil complete all as specified. Make of chemical:-Erove or equivalent
M&L Earth continuity conductor fixed to wall or buried on ground or any other indicated situation for loop earthing etc with Aluminium strip of size 25x4mm mm all as specified and directed .
Supply, Installation, testing and commissioning in replacement of 4 Pole Automatic Transfer Switch (ATS) 400 Amps, 415 Volts, 50 Hz, automatic/manual type with inbuilt time delay complete with enclosure all as specified.
Supply, Installation, testing and commissioning in replacement of 4 Pole Automatic Transfer Switch (ATS) 630 Amps, 415 Volts, 50 Hz, automatic/manual type with inbuilt time delay complete with enclosure all as specified.
Supply, installation, testing and commissioning in replacement of 4 pole phase corrector unit 100 Amps, 415 Volts, 50 Hz, automatic/manual type with inbuilt time delay complete with enclosure all as specified. Make: Havells/Universal Switchgear Control/Sinetrac.
Shifting of bollard light from existing position and fixing on PCC foundation (1x1x1 ft) by grouting , Nut bolt and making arrangement in PCC and fixing iron box with bus bar for termination of cable all as specified and directed by Engr-in-Charge
S&F thermoplastic cable junction box with metric knock out for cable entry of size 200x160x98mm with 4 Nos of 200A aluminium busbar mounted on insulators, terminal and MCB 10A capacity including fixing with clamp 30x5mm iron flat, nuts, bolts and washer complete including providing of steel conduit of dia 32mm bore of length 1.60 mtr including earth work for taking out of cable and fixing complete all as specified and directed.
Supply only aluminium/copper thimble ring/pin type of size 6 Sq mm to 35 sq mm all as specified
Supply only aluminium/copper thimble ring/pin type of size 50 Sq mm to 120 sq mm all as specified
Supply only aluminium/copper thimble ring/pin type of size 150 Sq mm to 300 sq mm all as specified
Taking out of unserviceable motor of high mask light pole and carrying out necessary repair work ,replacement of unserviceable spare parts and refix the motor to its original position, making all the connections properly and testing carried out upto satisfactory level of Engr-In-Charge by lowering and lifting the high mask light complete all as specified and directed.
S & F in replacement of Auto/ Manual switch for security light panel as per sample
S & F in replacement of timer MCX 31,4 pole, 240 Volt, 50 HZ for security light panel all as specified and directed by Engr-In-Charge.
S & F in replacement of HRC Fuse 20 Amps for security light panel all as specified and directed by Engr-In-Charge.
S & F in replacement of fuse 630 Amps for fuse box all as specified and directed by Engineer-In-Charge.
M&L 15mm thick rendering on fair or other than fair faces of brick work or concrete surfaces in cement mortar 1:4 finish even and smooth without using extra cement including taking down of cement plaster or brick wall surface including recking out joints hacking for key scrubbing down with water etc and removing the rubbish out of MOD Land complete all as specified and directed.
All as per Item No 217 above but cement mortar 1:6
M&L Preparation of new plastered or un-plastered surface of walls and applying two coats of oil bound distemper on walls over a coat of primer and over incl one coat of 3 mm thick wall care putty complete all as specified and directed.
M&L preparation of new plastered surfaces of wall and applying two coats of Finishing wall with acrylic smooth exterior paint of required shade: New work (Two or more coat applied @ 3.28Ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20/10 sqm Exterior Emulsion paint (APEX ULTIMA) over one coat of primer and over incl one coat of 1mm thick wall care putty all as specified and directed.
S&F in replacement of Powder coated aluminium (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long - 01 Nos, hinges type B-21 100mm long- 02 Nos, suitable handle - 01 Nos etc in each shutter including frame for window and ventilator shutters complete all as specified and directed.
S&F in replacement of powder coated aluminium doors shutter using Top and bottom Rails Jindal section No. 19511 (114.3x44.45x3.18mm), Vertical section No. 19509 (85.00x44 45x3.00mm), Middle section No. 19511 (114.30x44.45x3.18mm), Glazing plate section No. 19353 and Glazing clip section No. 19377 and 5 mm thick composite panels between aluminium sections as approved colours and where required and fixed with Builders hardware such as 02 Nos of aluminium tower bolt 150mm long, aluminium sliding door bolt 300mm long, 100mm stainless steel butt hinges 04 Nos in each shutter, 200mm aluminium handles 02 Nos for each shutter, Door stopper one for each shutter and necessary fittings, suitable size of rubber packing including frame for doors complete all as specified and directed
M/S ANIL KUMAR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .