Loading…
Loading…
Tender Value
₹33.0 L
EMD Value
₹65,900
Closing Date
16 Jul 2026, 6:00 pm7d left
CE CG GOA
INDIAN COAST GUARD CHICOLNA JNC NAGAR ROAD BOGMALO POST
PROVISION OF SMART METERING SYSTEM FOR SAMARTH ARUSH ABHIRAJ AMEYA AND ANKIT BUILDING AT CHICOLNA GOA
2026_MES_771027_1
84063
Open Tender
Civil Works
180 days
GOA
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE I CG GOA
₹65,900
Yes
10 Jun 2026
10 Jun 2026
23 Jul 2026
11 Jun 2026
16 Jul 2026
9 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Site survey, planning, Design, Supply, Install, integrate, testing, commissioning, demonstration for acceptance, training, operate & maintain the Advance Metering Infrastructure (AMI) at TRV Area & DHQ-11 Area Chicolna, Goa for End-to-End Smart Metering solution with pre- payment & post payment features & to enable complete energy accounting with zero manual intervention & thus to facilitate seamless operation of utility (MES unit(s)) businesses. Prior approval of Accepting Officer shall be obtained for the detailed planning before execution of work and contractor shall incorporate changes wherever required/ suggested/ordered by accepting officer and the rates quoted above shall deemed to inclusive of such provisions and its accessories before designing / execution. | |||||
| 1.01 | Supply and Installation of RF Smart Single Phase Meter with the following specifications:
• AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 & with BIS identification mark on Name Plate and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor, Bidirectional Communication; Integrated Load limiting /connect/disconnect switch; recording and reporting; Power event alarms; Remote firmware upgrade; TOD features; On demand reading and LED/LCD based circuitry.
• Meter Should support sending the following data to the software : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand
• Meter should have connect / disconnect functionality operable from prepaid billing software.
• The meter should support open communication protocol DLMS with the software
MAKE: Anchor (Panasonic),Secure, L&T, Schneider,Elmeasure
Note:
(a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES.
(b) It would be possible to run the meter in both prepaid and postpaid mode
(c) The meters would carry 5 year warranty. | 184 | Each | - | - |
| 2 | Supply and Installation of IP-67 protection Data Concentrator Units (DCU) compatible for remote Automatic Metering Infrastructure (AMI) solution and capable of communicating with the smart energy Meter in the corresponding frequency band and with the data server through GPRS/Ethernet. It would have internal memory to store data of at least 200 modules. It would have inbuilt battery back-up. It would have IP-67 protection. It would support auto discovery of the meters and self healing mechanism for the breaks in the RF network. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 500 Nos. of any type of smart meter (1ph/3ph). It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features.
Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc. DCU/Gateway shall be compatible with the Smart Meters mentioned above and the HES/MDMS which has been deployed for existing Smart Meters at CG Goa colonies.
Make: Anchor (Panasonic),Secure, L&T, Schneider, CyanConnode,Elmeasure | 1 | Each | - | - |
| 3 | Supply and Installation of single phase meter as repeaters (Signal booster) | 2 | Each | - | - |
| 4 | M & L for integration meter with existing server (GCC) complete all specifed & directed by Engr-in-Charge | 184 | Each | - | - |
| 5 | Comprehensive maintenance for RF Metering system including operating costs during two years of defect liability period. They would include the following items:
(a) Monthly SIM charges for the DCU. The contractor would ensure supply of appropriate SIMs to ensure necessary single availability. The contractor would change the SIM or SIM provider as required. In case of network issues, the contractor would liaison with the telecom service providers for necessary resolution.
(b) Recurring SMS charges. The SMS would be issued for the payments alerts, low balance alerts and disconnection / connection alerts.
(c) Software AMC. This would include necessary upgradations in the software such as support to the chrome browser changes, android version changes , iOS version changes. These changes happen on frequent basis and the software would support all the changes. | 4,416 | Each Meter per Month | - | - |
| - | Two years GCC Cloud Hosting charges during defect liability period | 304 | Each Meter per Year | - | - |
| - | Eight year comprehensive maintenance for RF Metering system including operating costs after two years of defect liability period. They would include the following items:
(a) Monthly SIM charges for the DCU. The contractor would ensure supply of appropriate SIMs to ensure necessary single availability. The contractor would change the sim or sim provider as required. In case of network issues, the contractor would liaison with the telecom service providers for necessary resolution.
(b) Recurring SMS charges. The SMS would be issued for the payments alerts, low balance alerts and disconnection / connection alerts.
(c) Software AMC. This would include necessary upgradations in the software such as support to the chrome browser changes, android version changes , iOS version changes. These changes happen on frequent basis and the software would support all the changes.
(d) Changes in the government tariff structure. The government tariff structure changes may require software upgrade. The same would be included in the AMC scope of work.
(e) Remote server admin support - Ensuring adequate database back up, upgradations in the operating system, anti virus updates, database upgrade etc.
(f) Reports Development - The additional reports as needed for the success of the project would be developed
(g) Software installation on any alternate / backup server if required
(h) The communication network monitoring and support
(i) Configuration of the repaired / replaced hardware in the system
(j) Trouble shooting and necessary actions to run the system as required.
(k) Software bug fixing as and when required | 17,664 | Each Meter per Month | - | - |
| - | Eight years GCC Cloud Hosting charges after defect liability period | 1,216 | Each Meter per Year | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
TENDERPAGES_84063.pdf
Tender Documents • 1.08 MB
BOQ_863431.xls
BOQ • 0.29 MB
AMDT_Letter_84063.pdf
PDF • 0.36 MB
Postpone.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid