Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹17.1 L+₹1.7 L (10.7%)Rejected-Finance GALI MODI THEKEDAR AMLOH ROAD KHANNA DISTT LUDHIANA | KHANNA | LUDHIANA | PUNJAB | L2 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
30 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lalgarh Jattan
GE Lalgarh Jattan
REPAIR/MAINT OF SEWAGE LINES ETC OF ZONE A, C AND D AT LGJ MIL STN
2021_MES_479255_1
8932-42/21-22
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
Class E cat a(ii)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹29,000
Yes
17 Nov 2021
1 Oct 2021
1 Nov 2021
1 Oct 2021
30 Oct 2021
16 Oct 2021
60 days
Amount
Excavation in trenches n.exc. 1.5 m wide and n.exc. 1.5m in depth and getting out in any type of soil complete all as specified and directed by Engr-in-charge.
Returning filling in including spreading leveling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and directed by Engr-in-charge.
Removal of excavated soil to a distance n.exc. 50m above the starting point complete all as specified and directed by Engr-in-charge.
M&L PCC 1:4:8 type C2 using 40mm graded stone aggregate as in foundation filling complete all as specified and directed by Engr-in-charge.
Demolition of brick work built in cement mortar including coping etc of manholes/septic tank in any position complete all as specified and directed by Engr-in-charge.
M&L fly ash brick work with sub class 'B' brick straight or curved on plan exc 6m mean radius in CM 1:4 complete all as specified and directed by Engr-in-charge.
M&L 15mm thick rendering on brick surfaces of wall in cm 1:4 finished even and smooth without using extra cement including mixing of WPC compound complete all as specified and directed by Engr-in-charge. Note : WPC shall be measured and paid separately
Supply only Integral water proofing compound complete all as specified and directed by Engr-in-charge.
Material and labour for moorum bed to drain pipes, spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-Charge.
Supply and laying DWCPE (SN8) 180 (OD)/163 (ID) mm diameter drain pipes as per IS-16098 (Part-II), laid in trenches on moorum bed to required slope, including all accessories/fittings, jointing and tested complete all as specified and as directed by Engineer-in-Charge
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregates for coping & benching to main holes etc complete all as specified and directed by Engr-in-charge.
Material and labour for cleaning of blockage of bathroom, kitchen,urinals and WHB at any location, in any lenght, at any floor by cleaning the nanitraps/gully traps by rodding/choke remover, manually or other wise including refixing of oval assess door covers with new nuts & washers, including removing of all wastes solid or liquid sludge throgh closed containter to any distance outside the cantonment area complete all as specified and as directed by Engr-in-Charge
Material and labour for cleaning of blockage of WC (any type) including cleaning of SGSW/CI pipe of any lenght upto Ist manhole by rodding choke remover, manually or otherwise including refixing of assess door covers with new nuts & washers, including removing of all wastes solid or liquid sludge throgh closed containter to any distance outside the cantonment area complete all as specified and as directed by Engr-in-Charge
Cleaning of underground SGSW/DWCPE/SN2 sewage pipes (Cleaning length n.exc. 30m from manhole to manhole or from manhole to septic tank) including taking off manhole cover and cleaning of manholes of any size and depth by using mechanized suction machine and throwing water into non residential area or in drain/nallah and replacing manhole cover in position after cleaning. Complete all as specified for sewage pipe lines of 150 mm bore pipes size. NOTE: (a) Cost of excavation and earth work for pits for burrying the waste/sludge etc shall deemed to be including the unit rate. (b) Any damage caused during cleaning shall be made good to the entire satisfaction to Engineer-in-charge by the contractor without any extra cost. (c) Once cleaned the sewage lines, the contractor shall maintain the lines funtional upto date of completion.
Cleaning of underground SGSW/DWCPE/SN2 sewage pipes (Cleaning length n.exc. 30m from manhole to manhole or from manhole to septic tank) including taking off manhole cover and cleaning of manholes of any size and depth by using mechanized suction machine and throwing water into non residential area or in drain/nallah and replacing manhole cover in position after cleaning. Complete all as specified for sewage pipe lines of 200 mm bore pipes size. NOTE: (a) Cost of excavation and earth work for pits for burrying the waste/sludge etc shall deemed to be including the unit rate. (b) Any damage caused during cleaning shall be made good to the entire satisfaction to Engineer-in-charge by the contractor without any extra cost. (c) Once cleaned the sewage lines, the contractor shall maintain the lines funtional upto date of completion.
Cleaning of underground SGSW/DWCPE/SN2 sewage pipes (Cleaning length n.exc. 30m from manhole to manhole or from manhole to septic tank) including taking off manhole cover and cleaning of manholes of any size and depth by using mechanized suction machine and throwing water into non residential area or in drain/nallah and replacing manhole cover in position after cleaning. Complete all as specified for sewage pipe lines of 250 mm bore pipes size. NOTE: (a) Cost of excavation and earth work for pits for burrying the waste/sludge etc shall deemed to be including the unit rate. (b) Any damage caused during cleaning shall be made good to the entire satisfaction to Engineer-in-charge by the contractor whtout any extra cost. (c) Once cleaned the sewage lines, the contractor shall maintain the lines funtional upto date of completion.
Supply and fixing cast iron acess door cover for 75mm bore pipes including all accesseries complete all as specified and directed by Engr-in-charge.
,---ditto all as per serial item No 17 above but 100mm bore complete all as specified and directed by Engr-in-charge.
S & F in repair cast iron bends (any radius) with Ducks foot or heel rest bend of 100mm bore dia complete all as specified and directed by Engr-in-charge.
S & F in repair cast iron bends (any radius) with Ducks foot or heel rest bend of 75 mm bore dia complete all as specified and directed by Engr-in-charge.
Demolition of cement concrete as in bed to drain pipe including packing under and haunching against the sides of pipe or as in manhole benching/bed etc. complete all as specified and directed by Engr-in-charge.
M & L Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branche channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 20mm graded crushed stone aggregate smooth finished and forming benching as required. Internal dia of pipe 150mm. Complete all as specified.
M & L precast cement concrete type B-1, 1:2:4 (20mm graded crushed stone aggregate) as in manhole cover set in CM 1:4 complete all as specified and directed by Engr-in-charge.
Demolition of reinforced cement concrete (reinforcement cut as reuired to facilitate demolition) complete all as specified and directed by Engr-in-charge.
M & L TMT bars (Fe-500D) 8mm mm dia in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) complete all as specified and directed by Engr-in-charge.
S & F 100 mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid In walls complete all as specified and directed by Engr-in-charge.
S & F 75 mm dia Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid In walls complete all as specified and directed by Engr-in-charge.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking it out of Walls, if required complete all as specified and directed by Engr-in-charge.
S&F 75mm thick precast cement concrete (RCPC) drain cover slab of size 600 mm dia circular cover including all accesseries required, and of 2 MT load bearing capacity complete all as specified and directed by Engr-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
AJAY CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .