Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹31.5 L+₹3.5 L (12.7%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹31.8 L+₹3.8 L (13.8%)Rejected-Finance | L3 | Rejected-Finance Being not lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
15 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) BAMRAULI
HQ CWE AF BAMRAULI ALLAHABAD-211012
IMPROVEMENT / UPGRADATION TO CERTAIN BUILDINGS IN OFFICERS MESS AF STATION GORAKHPUR
2021_MES_434205_1
87119/C/E8
Open Tender
Civil Works
Item Rate
182 days
Gorakhpur
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) Gorakhpur
₹70,000
Yes
7 Jun 2021
6 Apr 2021
17 May 2021
6 Apr 2021
15 May 2021
1 May 2021
60 days
Amount
Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for wall foundation etc or for manholes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil.
Returning filling in foundation/trenches including spreading leveling, watering and well ramming in layers not exceeding 25cm thick complete.
Earth filling under floor in layers not exceeding 25cm thick well ramming and watering as required.
Removal of excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Material and labour for anti-termite treatment (post construction) along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 liters per linear metre including drilling and plugging holes etc in apron complete all as specified and directed.
Material and labour for anti-termite treatment (post construction) of soil under existing floors using chemical emulsion @ one liter per hole, 300 mm apart including drilling holes and plugging 12 mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors etc complete all as specified and directed.
Material and labour for anti-termite treatment (post construction) of voids in masonry using chemical emulsion @ one liter per hole, 300 mm intervals including drilling holes at 45 degree and replugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors etc complete all as specified and directed.
Material and labour for anti-termite treatment (post construction) at point of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 liter per hole, by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same to match the existing surfaces etc complete all as specified and directed.
Provide Plain Cement concrete 1:4:8 type D-2 (Using 40mm graded crushed stone aggregate) in foundations, filling and mass concrete complete all as specified and directed.
Provide plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in surface channels and drains complete all as specified and directed.
Material and labour providng precast cement concrete 1:2:4 type B-1 using 20mm graded aggregate as in manhole / drain cover slabs set in cement mortar 1:4 complete all as specified and directed.
Material and labour provide Reinforced cement concrete nominal mix, 1:1½ :3 type A-1 (using 20mm graded stone aggregate) as in slab complete all as specified and directed. Note :- Reinforcement as required shall be measured and paid for separately under respective item of this schedule.
Material and labour providing, cement concrete type B1, 1:2:4 (20mm graded crushed store aggregate) in copings, and the like including weathering, slightly rounded or chamered angles and throating, complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Material and labour brick work with sub-class 'B' bricks (old size) straight or curved on plan exceeding 6 metre mean radius, built in cement and sand mortar (1:6) complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good cutting exceeding 10cm and not exceeding 20cm girth in brick wall complete all as specified and directed.
Taking down wooden Windows/Doors chowkats or frames exc 1.5 sqm but not exc 4 sqm each (without taking off shutters from the frames) including making good for fixing new frame. Note :- (i) Old shutters, frame guard bars etc shall be contractor property and necessary amount as per schedule of credit shall be deducted from the contractor payment. (ii) Quoted rate shall deem to be included cost of making good jambs portion.
Taking down wooden windows/ventilator/chowkhats or frames with shutter not exceeding 1.5 sqm each (without taking off shutters from frame) including maxing good for fixing new frame. Note :- (i) Old shutters, frame guard bars etc shall be contractor property and necessary amount as per schedule of credit shall be deducted from the contractor payment. (ii) Quoted rate shall deem to be included cost of making good jambs portion for fixing new frame.
Factory made prelam PVC door frame " of size 100x45mm ((minimum) with a wall minimum thickness of 5 mm made out of extruded PVC sheet of density 600 kg/cum manufactured by an ISO-9000 certfied company and by joining 3 number heat bent PVC sheet section, the inside section of minimum size 90x30mm shall be made from prelam coloured PVC sheet of 5mm (minimum) thickness, the inside section will be covered by sticking two long brackets of 15 mm x15mm mild steel square tube, the two vehicle door frame made of 5mm thick plain colour PVC sheet reinforced with mild steel square tube the vertical door frame are to be reinforced with (minimum) 40mmx20mm mild steel tube of 19 gauge (minimum) through out the frame. the door frame shall be fixed to wall using 8/100mm long mild steel screws through the frame by using and or fasterners. A minimum of 04 number of screw to be provided for each vertical member and two number for horizontal members etc. complete as per manufacturers specifications and as shown on drawing No.CWE/BAM/TD-40 Sheet No.1/3 & 2/3. Note :- Gap in between frame & wall/lintel shall be filled properly with suitable materials as per manufacturer's instruction to avoid crackes after wards. (ii) Colour & design shall be as approved by GE.
Supply only Aluminium, anodised, barrel tower bolts of extruded section size 200 mm long complete.
Supply only Aluminium, anodised, barrel tower bolts of extruded section size 150 mm long complete.
Supply only Aluminium, anodised, handle cast type size 125 mm long complete.
Supply only Aluminium, anodised, handle cast type size 150 mm long complete.
Supply only Aluminium, anodised, handle cast type size 100 mm long complete.
Supply only 75 mm long stainless steel butt hinges complete.
Supply only 100mm long stainless steel butt hinges complete.
Supply only 100mm size aluminimum butt hinges complete.
Supply only floor door stopper of aluminium alloy body and tongue, anodised with hard drawn spring, (overall length of cover plate) 140mm.
Supply and fix door closer, aluminum (extruded section) body, hydraulically regulated, designation 3, universal type suitable for door shutters of 851 to 1000mm in width complete all as specified and directed.
Supply and fix in repair chromium plated stainless steel rod 20mm dia curtain single rod with bracket fixed in brick/concrete wall and decorative nobs on each end of curtain rod fancy type fixed complete all as specified and directed.
Supply and fix in repair stainless steel (S-306 grade) wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed in as repairs and fixed with stainless steel wire stapples to aluminium frame.
Material and labour mild steel TMT bars 6 to 8 mm dia, and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking, ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Material and labour mild steel TMT bars 10 mm dia, and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking, ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Supply and fix clamps holder made out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stay to wall suitable for 100 mm dia pipe complete all as specified and directed. Note :- Clamp shall be painted with two coat of synthetic enamel paint over a coat of red oxide primer.
Supply and fix clamps holder made out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stay to wall suitable for 75 mm dia pipe complete all as specified and directed. Note :- Clamp shall be painted with two coat of synthetic enamel paint over a coat of red oxide primer.
Aluminium (powder coated) frame for doors with one or more rebates including necessary joining cleats, fastner etc to fix in existing opening complete Notes : (i) Thickness of powder coating (epoxy polyster) shall not be less than 50 micron. (ii) Shade/tint of powder coating (epoxy polyster) shall be as approved by GE. (iii) Gaps between frame and masonary to be filled with silicon gel for water tightness. (iv) Rates quoted includes making good of jambs, soffits and cills etc. (v) Aluminium section shall be as per drg No. CE/ALD/TD-224 sheet No 1/1 for doors. However size of frame as per actual site requirement.
Supply and fix aluminium powder coated door shutters type with top rail lock rail, bottom rail, styles etc including joining cleats, glazing clip, gasket, beading with locking arrangement, including 12 mm thick pre laminated particle board in lower pannel and 4.8 mm thick tinted glass in upper pannel including gasket, rubber packing, aluminimum beading of size as shown in drawing or as per manufacturer instructions, complete all as specified and as shown in drawings. Notes : (i) Frame of aluminimum door, hydraulic door closer, builder hardware shall be measured under respective item of this schedule. (ii) Aluminium section of shutter shall be as per Drg No. CE/ALD/TD-224 sheet No. 1/1.
Supply and fix aluminium (powder coated) sliding glazed shutter of suitable size with necessary jointing cleats, glazing clips, rubber gasket, aluminium snap beading and locking arrangement at both end, 5 mm thick tinted glass in single panes including all fittings and fixture complete all as specified and as shown in drawing. Notes : (i) Thickness of powder (epoxy polyster) coating shall not be less than 50 Micron (ii) Shade/tint of powder coating (epoxy polyster) shall be as approved by GE. (iii) Aluminium section shall be as per drg No. CE/ALD/TD-194 sheet No. 1/2 & 2/2
Supply and fix aluminium anodised (epoxy powder coated) grill of minimum weight 5.60 Kgs/Square metre fixing with aluminium rail of channels 12-15mm complete. Note :- Grill shall be Decogrille (7.5mm) design (DG-902) or equivalent design of make of aluminium section specified in Appendix 'B' to particular specifications.
Supply, fixing in position 4mm thick eco board classic acoustic ceiling tiles of size 600x600x4mm thick and placed on GI grid powder coated snap grid ceiling, 605x605 module consisting of wall angle section 24x24 mm and tee section with web height of 38mm and flange 24mm (colour white) (having rotary stiching on all T-section) with suspension system as shown in drawing No CWE/BAM/TD-34 She 1/1 and as approved by the GE complete all as specified and directed. Note :- (i) Ceiling tiles shall be of make Armstrong brand "DUNE RH99 (Bevelled / Tegular)" or equivalent brand of make as specified in Appendix 'B' to particular specifications. (ii) Thickness of GI section shall not be less than 3mm and shall be procured from the tile manufacturer. (iii) Section and hanging system shall have galvanizing of minimum 90 grams per square metre and of same make of tile. (iv) Work shall be executed by the manufacturer's authorised Vendor.
Material and labour cleaning the roof surface (padding) from dust/dirt and provide water proofing treatment using APP based polymeric water proofing membrance 3 mm thick conisting of reinforced with polyster non wove fabric (weight shall not be less than 150 gms/sqm or as per IS ) 90 to 100 micron thick center core of HMHDPE Film with standard weight not less than 3 Kg per Sqm with preparing surfaces by brushing with wire brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surface with funny bags to remove all loose dirt etc, applying consisting of the following operation:- (a) 10mm thick plaster/screed bed in cement mortar 1:3 complete mixed with water proofing compound as per manufactures instructions when concrete is still green (PCC padding) complete all as specified & directed (Note - WPC shall be measured and paid separately). (b) After the plaster is fully dried cleaning floor surface by wire brush brooming & removing dust & shall be painted with a coat of bituminous primer conforming to IS : 3384-1986 @ 0.3 Ltr per Sqm uniformily complete all as specified & directed. (c) After primer the entire roof surface applying tack coat of hot blown bitumen grade 85/25 grade conforming to 702-1988 @ 1.2 Kg per sqm over primer. (d) Over hot bitumen laying polymeric water proofing membrance 3 mm thick conisting of reinforced with polyster non wove fabric (weight shall not be less than 150 gms/sqm or as per IS ) 90 to 100 micron thick center core of HMHDPE Film with standard weight not less than 3 Kg per Sqm over entire area laid with 100mm side lap/150 mm end lap on prepared surfaces and under strict supervision of manufacturer’s technical representative & sealed complete all as specified & directed. (e) Cement concrete tiles 20cm x 20cmx20mm thick machine pressed, set jointed with grey cement and no pigment pointed in neat cement slurry over roof slab cut and polished including 20 mm thick screed bed in cement mortar (1:4) mixed with water proofing compound as per manufacturer instructions or @ 100 ml per bag of cement. (Liquid Water proofing compound shall be measured and paid in respective item of this schedule at supply only). (f) Water proofing treatment shall be carried out through authorized applicators only. (g) The work shall be carried out strictly as per manufacturer’s instructions.
Supply and fix pre painted galvalume aluminium zinc coating GI base corrugated steel sheet 0.50mm thick (TCT) (0.45 mm thickness of base metal) and colour as decided by Garrison Engineer based on availability from manufacturer having minimum tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws including side / end lap complete all as specified and directed by Garrison Engineer/ Engr-in-Charge. Note :- (i) Outer colour of sheet shall be as approved by GE based on availability from manufacturer . (ii) Work shall be executed by the manufacturer's authorised Vendor only.
Supply and fix in repair 18/19 mm thick Prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination, 4mm thick teak wood lipping on all edges and fixed to wooden frame with screws (for almirha) complete all as specified and directed.
Supply and fix 5 mm thick prelaminated solid PVC sheet in strips and channels feathered at the edges for fixing on solid PVC wall lining (Panelling insulated PVC wall lining inclusive of solvent cement and fixed on PVC frames along walls complete all as specified and directed.
Material and labour 40 mm thick plain cement concrete 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as levelling course on existing concrete surface over a coat of cement slurry as specified in MES SSR Part I complete all as specified and directed. Note :- Quoted rate shall deem to be included cost of cement slurry as specified in Para 13.32.7 of MES SSR Part I.
Material and labour 450 mmX350mm X 7-8 mm thick glazed ceramic coloured tiles in vertical surfaces such as skirting, dado, etc set and jointed in neat cement slurry and pointed in white or colured cement to match over & including 10 mm thick backing coat in cement and sand mortar (1:4) complete all as specified and directed. Note :- Quoted rate shall deem to be included cost of backing coat.
Material and labour 300mmx300mm x 7-8 mm thick non skid coloured ceramic tiles in floor, set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement and sand mortar (1:4) complete all as specified and directed. Note :- Quoted rate shall deem to be included cost of screed bed.
Material and labour 600mmx600mm x 10 mm thick vitrified ceramic light shade tiles in floor, set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement and sand mortar (1:6) complete all as specified and directed. Note :- Quoted rate shall deem to be included cost of screed bed.
Material and labour 600mmx600mm x 10 mm thick vitrified ceramic light shade tiles in skirtings, set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick backing coat in cement and sand mortar (1:4) complete all as specified and directed. Note :- Quoted rate shall deem to be included cost of screed bed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding etc including preparation of surface to received new floor finish/wall tiles and removing rubbish outside MOD land complete all as specified and directed.
Material and labour 15mm thick rendering in cement and sand mortar (1:6) on fair faces of brick work, surfaces finished even and fair without using extra cement, complete all as specified and directed.
Material and labour 15mm thick rendering in cement and sand mortar (1:4) on fair faces of brick work, surfaces finished even and fair without using extra cement, complete all as specified and directed.
Taking down cement plaster on brick walls, etc, including raking out joints, hacking for key, scrubbing down with water etc & prepare surface to receive new plaster complete all as specified and directed.
Complete removal of existing treatment from wall and applying 3 mm thick wall care putty including preparing surfaces of wall and applying two coat of oil emulsion distemper over a coat of primer complete all as specified and directed.
Complete removal of existing treatment from wall including preparing surfaces of wall and applying two coat of cement based paint over a coat of primer complete all as specified and directed.
Preparing new plastered surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
Preparing new plastered surfaces of wall and applying two coat of oil emulsion distemper over a coat of primer over a coat of 3 mm thick wall care putty complete all as specified and directed.
Complete removal of existing treatment from ceiling including preparing old surfaces and applying two coat of white wash complete all as specified and directed.
Preparing old treated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete.
Preparing old treated surfaces of wood or wood based materials of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed.
Material and labour 15mm dia Tubes, ‘medium grade’ galvanised, with all fitting concealed or fixed on walls and ceilings or laid in floors etc and testing complete all as specified and directed. Note :- Quoted rate shall deem to be included cost of cutting chasses in wall for concealed pipe.
Material and labour 20mm dia Tubes, ‘medium grade’ galvanised, with all fitting concealed or fixed on walls and ceilings etc and testing complete all as specified and directed. Note :- Quoted rate shall deem to be included cost of cutting chasses in wall for concealed pipe.
Refixing old steel tubing and connections in new or old, connection in wall position (walls, ceiling, floors etc) of 15mm bore size including new fittings.
Refixing old steel tubing and connections in new or old, connection in wall position (walls, ceiling, floors etc) of 20mm bore size including new fittings.
Taking down 15mm bore GI tubing and connection fixture etc from wall complete. Note :- Old retrived pipes, fittings, taps, valve etc shall be contractor property and necessary amount as schedule of credit shall be deducted from the contractor due payment.
Taking down 20mm bore GI tubing and connection fixture etc from wall complete. Note :- Old retrieved pipes, fittings, taps, valve etc shall be contractor property and necessary amount as schedule of credit shall be deducted from the contractor due payment.
Hoisting and fixing Rotational moulded polyethylene cylindrical vertical with closed top water storage tank double layered, 1000 Ltr capacity, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection including ball brass valves high pressure of with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed 20mm dia polythene floated fly nut, tank nipple, 2 Nos 20mm dia union, wash out pipe etc including dismantling of existing unserviceable water tank of any type complete all as specified and directed. Note :- (i) Old tank with fitting shall be contractor property and necessary amount as per schedule of credit shall be deducted from contractor's due payments.
Material and labour plain cement concrete (1:4:8) type D2 (using 40 mm graded crushed stone aggregates) as in bed to drain pipes including packing under, and haunching against the sides of pipe after they are laid and tested for 150 mm bore pipe.
Supply and fix reinforced cement concrete pipe 150 mm bore NP-3 laid in trenches and jointed in cement sand mortar (1:1) including collar complete.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150 mm bore complete all as specified and directed.
Supply and fix cast iron nahani trap, 75mm outlet dia, plain with stainless steel grating including jointing with run lead to connection pipe and bedded in PCC 1:2:4 type B-1(20 mm graded stone aggregate) complete all as specified and directed.
Supply and fix 100 mm outlet dia cast iron bends of any radius, with duck foot heal rest including jointing with run lead to complete all as specified and directed.
Supply and fix 75 mm outlet dia cast iron bends of any radius, with duck foot heal rest including jointing with run lead to complete all as specified and directed.
Supply and fix cast iron branch pieces, 100 mm dia, equal or unequal ordinary or inverted fitted with oval access doors complete all as specified and directed.
Supply and fix cast iron branch pieces, 75 mm dia, equal or unequal ordinary or inverted fitted with oval access doors complete all as specified and directed.
Supply and fix cast iron cowls 100 mm dia, complete all as specified and directed.
Supply and fix cast iron cowls 75 mm dia, complete all as specified and directed.
Supply and fix 100mm bore cast iron centrifugal spun pipe soil waste, and vent rain water pipe single socketed in any length with lead joints laid in trenches or in floor complete all as specified and directed. Note :- (i) Fitting such as bend, tee and cowl shall be measured and paid for separtely as supply only. (ii) Excavation and earth work shall be measured as paid for separately under respective item of this schedule.
Supply and fix 100mm bore cast iron centrifugal spun pipe soil waste, and vent rain water pipe single socketed in any length with lead joints laid in walls complete all as specified and directed. Note :- (i) Fitting such as bend, tee and cowl shall be measured and paid for separtely as supply only.
Supply and fix 75 mm bore cast iron centrifugal spun pipe soil waste, and vent rain water pipe single socketed in any length with lead joints laid in trenches or in floor complete all as specified and directed. Note :- (i) Fitting such as bend, tee and cowl shall be measured and paid for separtely as supply only. (ii) Excavation and earth work shall be measured as paid for separately under respective item of this schedule.
Supply and fix 75 mm bore cast iron centrifugal spun pipe soil waste, and vent rain water pipe single socketed in any length with lead joints laid in walls complete all as specified and directed. Note :- (i) Fitting such as bend, tee and cowl shall be measured and paid for separtely as supply only.
Extra over cast iron pipe and fittings if lead joints is provided in lieu of cement joints for 100 mm dia pipe complete all as specified and directed.
Extra over cast iron pipe and fittings if lead joints is provided in lieu of cement joints for 75 mm dia pipe complete all as specified and directed.
Supply and fix in repair for 15mm bore wall mixer (wall mounted) with bend pipe for overhead shower including chromimum plated with arrangement of both overhead shower rose of size 100 mm x 100 mm and telephonic shower (3-in-1) complete all as specified and directed. Note :- (i) Wall mixer cat part No F 2002403 of Cera or equivalent model of make as specified in Appendix 'B' to Particular specifications. (ii) Oerhead shower rose cat part No F 7020306 of Cera or equivalent model of make as specified in Appendix 'B' to Particular specifications (iii) Telephonic shower cat part No F 7030301 of Cera or equivalent model of make as specified in Appendix 'B' to Particular specifications
Supply and fix 15mm bore stop valve cast copper alloy, in repairs, fancy type, with long shank and cup (concealed type) chromium plated screwed down, high pressure with crutch or butterfly handle screwed both ends (externally threaded) for iron pipe or for unions and fixed complete all as specified and directed.
Supply and fix Bib tap long body with wall flange, in repairs fancy type, chromium plated, brass, screwd for 15mm bore iron pipe with capstain head complete all as specified and directed. Note :- Bib tap cat part No F200011 of Hindware or equivalent model of make as specified in Appendix 'B' to Particular specifications.
Supply and fix in repairs perforated chromium plated brass shower rose with swivel joints, heavy pattern 125mm dia rim with 150mm long brass chromium plated extension rod (fancy type) suitable for 15mm bore inlet complete all as specified and directed. Note :- Shower rose cat part No F160051 of Hindware or equivalent model of make as specified in Appendix 'B' to Particular specifications.
Supply and fix in repair brass chromium plated oval shape soap dish holder type (minimum 125mm long) complete all as specified and directed.
Supply and fix in repairs 20 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends (externally threaded) for iron pipe and fixed complete all as specified and directed.
Supply and fix in repairs PVC braided connection 600mm long with two numbers check nut washers etc complete all as specified and directed.
Supply and fix in repair vitreous china wash down water closet (Pedestal Pattern) (white) including closet seat cover, PVC flushing cistern 10 litre capacity, flushing pipe, toilet paper holder, hand shower (health faucet) ABS body with wall hook and 1 metre SS braided ruber hose pipe, 15 mm bore CP brass bib tap (two way) PVC braided connection, angular stop cock (valve) with flange etc complete all as specified in particular specification.
Supply and fix salt glazed stone ware (SGSW) gully trap 150x150mm size, square or rounded mouthed, type 'P' or S setting and jointing with solvent cement mortar including necessary concrete cover complete all as specified and directed.
Supply and fix gully trape cover 400x400mm and 50 mm thick PFRC (Pre cast reinforced) complete all as specified and directed.
Supply and fix in repair vitreous china wash hand basin (white), flat back of minimum size 550mm x 400mm with and including a pair of cast iron brackets embedded in PCC (1:3:6) type C1 blocks of size 10x 7.5x15cm, 32 mm dia PVC waste pipe of suitable length, 32mm bore chromium plated brass waste fitting, PVC braided connection, CP coupling, pillar tap CP long neck, CP angular valve with flange, (for 15 mm bore pipe) CP bottle trap etc complete all as specified in particular specifications.
Supply and fix in repair brass chromium plated towel rack with brackets fixed to wall with chromium plated brass screws 600mm long complete all as specified in particular specifications. Note :- (i) Towel rack cat part No F5002101 of Cera or equivalent model of make as specified in Appendix 'B' to Particular specifications
Supply and fix (in repair) for 15mm bore central hole basin mixer fancy type with regular spout without pop up waste system with 450mm long braided connection & nut of brass complete all as specified and directed. Note :- (i) Basin mixer cat part No F2008461 of Cera or equivalent model of make as specified in Appendix 'B' to Particular specifications
Supply and fix in repair fancy type corner glass self size 225 mm x 225 mm complete. Note :- (i) corner glass self cat part No F5005102 of Cera or equivalent model of make as specified in Appendix 'B' to Particular specifications
Taking down carefully existing aluminium/copper batten concealed point, wiring for light/fan/socket/bell or power point excluding all fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc complete all as specified and directed. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fitting and fixture as directed and deposited in MES store yard of GE (AF) Bamrauli. Receipt shall be obtained before claiming the payment of new fittings. (ii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. (iii) Old unserviceable wiring fittings, fixture, etc other than light fittings shall be contractor's property and necessary amount as per schedule of credit from contractor due payment.
Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqmm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed multistranded copper conductor FRLS Cables as earth wire connected to earth dolly incl metal junction box, grid plate and base plate suitable for modular switches, sockets and switch for one light point /exhaust fan point / call bell point controlled by one switch. Note : (i) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit. (ii) Switches, sockets, etc shall be measured and paid for separately.
Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed copper conductor earth wire connected to earth dolly including metal junction box, grid plate and base plate suitable for modular switch, socket for one sockets outlet on independent board controller by one switch 5/6 Amps. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscreasing of the service fitting and fixture as directed and kept in safe custody for refixing i.e like fans, regulator, geysers, light fitting, DBs etc if not specified in this item of schedule. (ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. (iv) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit. (v) Switches, sockets, etc shall be measured and paid for separately.
Point wiring with PVC insulated, unsheathed single core, nominal area 1.5 sqm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 1.5 sqmm unsheathed copper conductor earth wire connected to earth dolly including metal junction box, grid plate and base plate suitable for modular switch, socket for one sockets outlet on same board with other switches 5/6 Amps. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscreasing of the service fitting and fixture as directed and kept in safe custody for refixing i.e like fans, regulator, geysers, light fitting, DBs etc if not specified in this item of schedule. (ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. (iv) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit. (v) Switches, sockets, etc shall be measured and paid for separately.
Point wiring with PVC insulated, unsheathed single core, nominal area 2.5 sqm with multistranded copper conductor FRLS Cable 1100 volts grade drawn into and included rigid PVC conduit (concealed) with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 2.5 sqmm unsheathed copper conductor earth wire connected to earth dolly including metal junction box, grid plate and base plate suitable for modular switch, socket for one sockets outlet on independent board controller by one switch 15/16 Amps. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscreasing of the service fitting and fixture as directed and kept in safe custody for refixing i.e like fans, regulator, geysers, light fitting, DBs etc if not specified in this item of schedule. (ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. (iv) The cost of chases cutting on wall for concealing conduit, metal boxes, grid plate and base plate quoted rated are included in the unit. (v) Switches, sockets, etc shall be measured and paid for separately.
Supply and fix switch modular flush 6 Amp single pole one way(one module) complete all as specified and directed.
Supply and fix socket modular flush 6 Amp 2/3 pin two module complete all as specified and directed.
Supply and fix socket modular flush 6/16 Amp 2/3 pin combined two module complete all as specified and directed.
Supply and fix modular switch flush 16 Amp one module complete all as specified and directed.
Supply and fix ceiling rose, PVC/Polycarbonate isolated body complete all as specified and directed.
Supply and fix stepped type electronic fan regulator flush type and connecting up. Regulator shall be 240 volts on the existing phenolic laminated sheet of make specified in Appendix 'B' to particular specifications complete all as specified and directed.
Supply and fix factory made sheet metal enclosures distribution boards, (protection class IP-42) double door, suitable for mounting MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, single pole and neutral, 8 ways, 240 volts Note :- MCBs shall be measured and paid for separately under respective item of this schedule.
Supply and fix MCB, SP, 6 to 32 Amp rating, 230 volt, 10 KA, 'C' series fixed in DBs catered herein before..
Supply and fix MCB, Single pole and neutral, 230 volt, 32 to 40 Amp rating 10KA, C series fixed in DBs catered herein before.
Supply and fix industrial socket with single pole and neutral sheet metal enclosure with a two pin and earth plug and socket 240 V 50 Hz complete with one single pole MCB, 20 Amp, 'C' series complete all as specified and directed by Garrison Engineer / Engineer-in-Charge..
Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 4 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 4.0 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete. Note:- (a) Two runs of 6 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Supply, fixing in replacement and connecting wall mounted LED light fitting 20 Watt LED (6000K/6500K) (1200/1144mm) extruded aluminium heat sink provided for efficeint heat dissipation intergrated electronic driver including necessary electric connection including taking down old fittings complete all as specified and directed.. Note :- Fitting shall be of Make Philips cat part No BN 100CLED 405-6500 PSU L1 20 GR Havells cat part No LUMILINEPLUSBS22WLED865SPCSS or equivalent model of make specified in Appendix 'B' to particular specifications. Note :- Serviciable old light fittings retrieved under this item including tube light/bulb, shall be deposited in the MES store yard of AGE (E/M) under GE (AF) Gorakhpur for checking of serviciability and receipt shall be obtained before allowing payment for new fittings. (ii) Light fittings (other than servicable ) retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues.
Supply, fixing in replacement and connecting wall mounted LED light fitting 2 feet long 10 Watt LED (6000K/6500K) (1200/1144mm) extruded aluminium heat sink provided for efficeint heat dissipation intergrated electronic driver including necessary electric connection including taking down old fittings complete all as specified and directed.. Note :- Fitting shall be of Make Philips cat part No BN 021 LED10S 6500 PSU GR S1, Havells cat part No LUMILINEPLUSBS10WLED865SPCSS or equivalent model of make specified in Appendix 'B' to particular specifications. Note :- Serviciable old light fittings retrieved under this item including tube light/bulb, shall be deposited in the MES store yard of AGE (E/M) under GE (AF) Bamrauli for checking of serviciability and receipt shall be obtained before allowing payment for new fittings. (ii) Light fittings (other than servicable ) retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues.
Supply and fix in replacement lamp holder PVC/polycarbonate type with back plate suitable for batten fitting including LED lamps of 9 watt complete all as specified and directed by Garrison Engineer / Engr-in-Charge.
Supply and fixing in replacement of exisiting light fitting with recess mounting 2'x2' LED fitting of 36 Watt with white powder coated CRCA housing with high power LEDs with aluminum front frame with flat white high transmission acrylic cover including necessary electric connection all as specified and as directed. Note :- (i) Fitting shall be of Make Philips Cat No RC375BLED28S/865 PSU W60L60WH, Havells, Cat No PLANO2X2PLR36WLED857S or equivalent model of make specified in appendix 'B' to particular specifications including taking down old unserviciable fittings. (ii) Light fitting of other make of higher capacity may be used without any price adjustment. (iii) Old retrived fittings shall be contractor property and necessary amount as schedule of credit shall be deducted from the contractor due payment.
Supply and fix exhaust fans (metallic) of 300/308 mm sweep, heavy duty, four blade, double ball bearing ,1400 RPM, minimum suitable for SP, 230 / 250V, 50 Hz, AC supply with louver shutters including making holes in brick wall of suitable size and disturbed surfaces shall be made good to match the existing finishes complete all as specified and directed by Garrison Engineer / Engr-in-Charge. Note :- (i) Make Havells Model No : Ventil Air or equivalent model of make mentioned in Appendix 'B' to particular specifications. (ii) Unit rate quoted by tenderer is deemed to include the cost of demolition /dismanting of brick work in wall for making hole and making good the surfaces to match existing schedule of finishes.
Dismantling of cast iron or reinforced concrete drain pipe fixed in cement mortar of 100/75 mm dia taking out in floors, trenches or walls complete all as specified and directed. Note :- (i) Excavation and earth work required shall be measured and paid for separately. (ii) Rubbish shall be removed out site MOD land.
Demolition of brick masonry quions, arches, pillars etc, but excluding ashlar fackings, dressed stonewrk and precast concrete articles. Note : (i) Material retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. (ii) Rubbish shall be removed out site MOD land.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including cutting reinforcement as required to facilitate demolition all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for cement concrete including roof padding, including cleaning the surfaces with wire brushes etc complete all as specified and directed.
Demolition of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs / blankets any thickness, including cover fillets etc . Note :- Material retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. (ii) Rubbish shall be removed out site MOD land.
Dismantling asbestos (corrugated, semi corrugated etc) sheet in roof covering. Note :- (i) Material (other than servicable sheet & ridges) retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. (ii) Rubbish shall be removed out site MOD land.
Demolition of brick tiles flat or edges pointed in any type of mortar complete all as specified and directed. Note :- (i) Material (other than servicable ) retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. (ii) Rubbish shall be removed out site MOD land.
Demolition taking down and breaking up drain pipes (salt glazed ware, AC) set in cement mortar any size and any location. Note :- Excavation and earth work required shall be measured and paid for separately.
ANIRUDH ENTERPRISES
Sheo Prasad
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .