Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC Being L1 |
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
4 May 2022, 3:00 pmClosed
Chief Engineer, CED
Civil Engineering Division, BARC, Mumbai
Execution of Nuclear Agricultural Technologies exhibition Centre in New Field House Building at North site, BARC, Trombay, Mumbai.
2022_BARC_683601_1
BARC/CED/ET/02/2022-2023 Dated 08.04.2022
Open Tender
Civil Works
Item Rate
120 days
New Field House Building at North site, BARC, Trom
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹3.2 L
Civil Engineering Division, BARC, Mumbai
22 Jul 2022
13 Apr 2022
6 May 2022
13 Apr 2022
4 May 2022
27 Apr 2022
13 Apr 2022 - 19 Apr 2022
22 Apr 2022
Amount
SECTION - A - SPECIALISED /INTERIOR WORKS Design of state of the Art exhibition centre with all interior design, services, PH works, HVAC, STRUCTURAL, Electrical, with issue of all GFC drawing , BOQs and specifications. The works has to be carried through specialized agency as directed by Engineer-in-Charge etc complete.The Specialized agency will be subject to evaluation by the Engineer-in Charge and only approved Specialized agency will be authorised to carry out the subject work.
Dismantling work including disposal of unserviceable surplaus material and stacking of serviceable materials within 100 m lead as directed by the Engineer-in-charge.
Demolition and Discarding of 100mm th. Dry Wall Glass Partition with Aluminium framing, with Sill Level at +0.9m and Lintel Level at +2.4m. The Partition to be demolished totally from the Base frame at the Floor till the Frame in the Slab.
Removing of a Double Shutter Glass door along with all the Hardware, floor spring and Pivot fixed to the Lintel. All Hardwares to be preserved carefully and should be used for the New Glass Door in the Entrance.
Removal and Disposal of Existing Flat Gypsum False ceiling along with its support members from the ceiling .
Removal and Disposal of Existing Vertical Gypsum False ceiling in Coves along with its support members from the ceiling .
Removal and Disposal of Existing 600 x 600 Grid Gypsum False ceiling along with its support members from the ceiling .
Preparing and applying Bonded Cement Sand Screed in the holes and depressions formed due to Partition framing fixing in the Floor and RCC Slab above. Ready-mixed sand and cement screeds that are factory-mixed and then delivered to site. Reinforcement is required, this can either be in the form of a fine metal mesh, fibres which are normally polypropylene or a fine glass mesh. The Screed has to laid in level with the existing Floor finish. The rates are inclusive of the cost of all materials & labour charges.
Flooring work
Supply and Fixing of Approved Carpet Flooring as per Specifications mentioned in the Specificaitons sheet. Full Spread Application with approved Pressure Sensitive Adhesive / Water Based / Solvent-Free / Low Odour / CRI Green Label Certified (0 Grams VOC). Rate to be inclusive of 7-8mm thick Carpet Underlay and Moisture Barrier made up of 100% recycled PET and ment to heavy traffic area. Moisture barrier padding is floor padding that has a layer that prevents liquids (spills, urine, etc) from passing from the floor to the floorboards, and it also prevents vapor from coming up from the base floor (concrete, etc) through the carpet. Covering of Carpet with 2 Layers of 300 micron thick protective plastic sheet to be considered for floor covering to avoids damages to the carpet during construction finishing stage, In the process vendor should supply one layer of plastic and how ever if required, they will cover the exposed area once again with another layer of plastic, sealing of joints with tape and remove at handover stage. 2 cycles of the Shampooing of Carpet with Hot Water Injection & Extraction method to be considered - Cycle 1 will be done before beneficial occupancy & Cycle 2 will be after six months/one year or as when required by BARC. For Technical specifications refer Specification sheet. The work has to be carried out as per drawing and detail specifications. AS PER ID 1003- FL-1, 2 &3
Entrance Metal Threshold T shape brass Metal Threshold for Carpet Divider as per specifications and sizes as per detail document.
Steps Threshold Trim L shape brass metal for step nosing as per specifications and sizes as per detail document.
SKIRTING WORK
Providing and Fixing of Well Seasoned Hardwood Skirting of 100mm High x 19mm ThkH. finished as per the Specifications and schedule of Finishes Sheet. The Hardwood should be seasoned to accept all Atmospheric Conditions and Changes with rise and fall in Temperature, Moisture, Humidity along with the Wear and Tear of Heavy Traffic. Hardwood to be fixed to the base with clipping / grooving system and no nails to be used for permanent/Temporary fixing. Aluminium Framework with Fire rated Flexi Ply at curved spaces and Fire Rated BWP ply for straight Partitions.
Providing and fixing of Polished Granite Skirting as per approved Design, 100mm High x 19mm Thk. finished as per the Specifications and schedule of Finishes Sheet. Aluminium Framework with Fire rated Flexi Ply at curved spaces and Fire Rated BWP ply for straight Partitions.
Providing and fixing SS /Brass Metal Skirting as per specifications .
WALL PANELLING- Item will be executed as as per drawing and specifications
1. 50mm x 50mm x 1.2mm Aluminium Frame Work in 600mm x 600mm Grid fixed to the Slab with slotted angles and anchored to the Mother Slab. 2. 19 mm th. Fire Rated Ply on Both sides 3. 48kg/M3 Density Glass Wool Filling. 4. Inside 1.5mm th. Laminate Panelling. 5. Outside 4mm th. Veneer Panelling. 6. All hardware to be ISI mark Grade. 7. Veneer to Ply fixing with Fire Rated Glue Hitec Make or equivalent. Supply, fabrication of paneling consisting of 4mm thick veneer with Waterbase PU polish finish as indicated Pressed on 12 mm thick marine plywood complying to IS 710 Joints if any, shall be 4mm wide and shall be finished with matching veneer. Marine plywood for straight paneling and flexi ply for curvilinear paneling. Mounted on framework of aluminium hollow sections of 1.2 mm in thickness, not less than 50mm x 50mm in size and not more than 600mm spacing both ways as applicable. Structural Stability Certificate and Design to be submitted for all partitions. All Aluminium Framework should be anchored to the RCC Slab below and RCC Slab above. All Metal Partitions to be fixed in Screw system or Nut and Bolt System with slotted angles for Ceiling slab. No Welding is allowed. All should be prefabricated and assembled on site. Aluminium Framework with Fire rated Flexi Ply at curved spaces and Fire Rated BWP ply for straight Partitions. All framing should contain Acoustical Wool filling. General Physical Data: Flammability: BS 476 Part 4 (1970) Non-combustible Building Regulations: Class OProduct Density: 45kg/m3 AMW50 is supported by chicken wire mesh stapled to joist sides, the insulation to provide one-hour fire rating without reducing the soundproofing properties of the product. Sound Reduction Obtainable: AMW50: 1.40 As per FFE-LT-01- VN-02 REf : DRG ID-5001
1. 50mm x 50mm x 1.2mm Aluminium Frame Work in 600mm x 600mm Grid fixed to the Slab with slotted angles and anchored to the Mother Slab. 2. 19 mm th. Fire Rated Ply on Both sides 3. 48kg/M3 Density Glass Wool Filling. 4. Inside 1.5mm th. Laminate Panelling. 5. Outside 1.5mm th. Laminate Panelling. 6. All hardware to be ISI mark Grade. 7. Laminate to Ply fixing with Fire Rated Glue Hitec Make or equivalent. Supply, fabrication of paneling consisting of 4mm thick veneer with Waterbase PU polish finish as indicated Pressed on 12 mm thick marine plywood complying to IS 710 Joints if any, shall be 4mm wide and shall be finished with matching veneer. Marine plywood for straight paneling and flexi ply for curvilinear paneling. Mounted on framework of aluminium hollow sections of 1.2 mm in thickness, not less than 50mm x 50mm in size and not more than 600mm spacing both ways as applicable. Structural Stability Certificate and Design to be submitted for all partitions. All Aluminium Framework should be anchored to the RCC Slab below and RCC Slab above. All Metal Partitions to be fixed in Screw system or Nut and Bolt System with slotted angles for Ceiling slab. No Welding is allowed. All should be prefabricated and assembled on site. Aluminium Framework with Fire rated Flexi Ply at curved spaces and Fire Rated BWP ply for straight Partitions. All framing should contain Acoustical Wool filling. General Physical Data: Flammability: BS 476 Part 4 (1970) Non-combustible Building Regulations: Class OProduct Density: 45kg/m3 AMW50 is supported by chicken wire mesh stapled to joist sides, the insulation to provide one-hour fire rating without reducing the soundproofing properties of the product. Sound Reduction Obtainable: AMW50: 1.40 As per FFE-LT-01- DRG ID-5001
1. 50mm x 50mm x 1.2mm Aluminium Frame Work in 600mm x 600mm Grid fixed to the Slab with slotted angles and anchored to the Mother Slab. 2. 19mm th. Fire Rated Ply on One sides 3. 48kg/M3 Density Glass Wool Filling. 4. Inside Fixed to the Wall. 5. Outside 19mm th. OSB Panel in Clear Lacquered Finish. 6. All hardware to be ISI mark Grade. 7. OSB to Ply fixing with Fire Rated Glue Hitec Make or equivalent. Supply, fabrication of paneling consisting of 4mm thick veneer with Waterbase PU polish finish as indicated Pressed on 12 mm thick marine plywood complying to IS 710 Joints if any, shall be 4mm wide and shall be finished with matching veneer. Marine plywood for straight paneling and flexi ply for curvilinear paneling. Mounted on framework of aluminium hollow sections of 1.2 mm in thickness, not less than 50mm x 50mm in size and not more than 600mm spacing both ways as applicable. Structural Stability Certificate and Design to be submitted for all partitions. All Aluminium Framework should be anchored to the RCC Slab below and RCC Slab above. All Metal Partitions to be fixed in Screw system or Nut and Bolt System with slotted angles for Ceiling slab. No Welding is allowed. All should be prefabricated and assembled on site. Aluminium Framework with Fire rated Flexi Ply at curved spaces and Fire Rated BWP ply for straight Partitions. All framing should contain Acoustical Wool filling. General Physical Data: Flammability: BS 476 Part 4 (1970) Non-combustible Building Regulations: Class O Product Density: 45kg/m3 AMW50 is supported by chicken wire mesh stapled to joist sides, the insulation to provide one-hour fire rating without reducing the soundproofing properties of the product. Sound Reduction Obtainable: AMW50: 1.40 SPACE - 88mm thk
1. 50mm x 50mm x 1.2mm Aluminium Frame Work in 600mm x 600mm Grid fixed to the Slab with slotted angles and anchored to the Mother Slab. 2. 19 mm th. Fire Rated Ply on One sides 3. 48kg/M3 Density Glass Wool Filling. 4. Inside Fixed to the Wall. 5. Outside 19 mm th. OSB Panel in Clear Lacquered Finish. 6. All hardware to be ISI mark Grade. 7. OSB to Ply fixing with Fire Rated Glue Hitec Make or equivalent. Supply, fabrication of paneling consisting of 4mm thick veneer with Waterbase PU polish finish as indicated Pressed on 12 mm thick marine plywood complying to IS 710 Joints if any, shall be 4mm wide and shall be finished with matching veneer. Marine plywood for straight paneling and flexi ply for curvilinear paneling. Mounted on framework of aluminium hollow sections of 1.2 mm in thickness, not less than 50mm x 50mm in size and not more than 600mm spacing both ways as applicable. Structural Stability Certificate and Design to be submitted for all partitions. All Aluminium Framework should be anchored to the RCC Slab below and RCC Slab above. All Metal Partitions to be fixed in Screw system or Nut and Bolt System with slotted angles for Ceiling slab. No Welding is allowed. All should be prefabricated and assembled on site. Aluminium Framework with Fire rated Flexi Ply at curved spaces and Fire Rated BWP ply for straight Partitions. All framing should contain Acoustical Wool filling. General Physical Data: Flammability: BS 476 Part 4 (1970) Non-combustible Building Regulations: Class O Product Density: 45kg/m3 AMW50 is supported by chicken wire mesh stapled to joist sides, the insulation to provide one-hour fire rating without reducing the soundproofing properties of the product. Sound Reduction Obtainable: AMW50: 1.40 As per FFE-VN-01- SPACE - 200mm thk
1. 50mm x 50mm x 1.2mm Aluminium Frame Work in 600mm x 600mm Grid fixed to the Slab with slotted angles and anchored to the Mother Slab. 2. 19mm th. Fire Rated Ply on One sides 3. 48kg/M3 Density Glass Wool Filling. 4. Inside Fixed to the Wall. 5. Outside 19mm th. OSB Panel in Clear Lacquered Finish. 6. All hardware to be ISI mark Grade. 7. OSB to Ply fixing with Fire Rated Glue Hitec Make or equivalent. Supply, fabrication of paneling consisting of 4mm thick veneer with Waterbase PU polish finish as indicated Pressed on 12 mm thick marine plywood complying to IS 710 Joints if any, shall be 4mm wide and shall be finished with matching veneer. Marine plywood for straight paneling and flexi ply for curvilinear paneling. Mounted on framework of aluminium hollow sections of 1.2 mm in thickness, not less than 50mm x 50mm in size and not more than 600mm spacing both ways as applicable. Structural Stability Certificate and Design to be submitted for all partitions. All Aluminium Framework should be anchored to the RCC Slab below and RCC Slab above. All Metal Partitions to be fixed in Screw system or Nut and Bolt System with slotted angles for Ceiling slab. No Welding is allowed. All should be prefabricated and assembled on site. Aluminium Framework with Fire rated Flexi Ply at curved spaces and Fire Rated BWP ply for straight Partitions. All framing should contain Acoustical Wool filling. General Physical Data: Flammability: BS 476 Part 4 (1970) Non-combustible Building Regulations: Class O Product Density: 45kg/m3 AMW50 is supported by chicken wire mesh stapled to joist sides, the insulation to provide one-hour fire rating without reducing the soundproofing properties of the product. Sound Reduction Obtainable: AMW50: 1.40 (SPACE- 300mm thk)
1. 50mm x 50mm x 1.2mm Aluminium Frame Work in 600mm x 600mm Grid fixed to the Slab with slotted angles and anchored to the Mother Slab. 2. 19mm th. Fire Rated Ply on One sides 3. 48kg/M3 Density Glass Wool Filling. 4. Inside Fixed to the Wall. 5. Outside 12mm th. Softboard with Fabric. 6. All hardware to be ISI mark Grade. 7. Softboard to Ply fixing with Fire Rated Glue Hitec Make or equivalent. - 15mm TH. softboard Core. Supply, fabrication of paneling consisting of 4mm thick veneer with Waterbase PU polish finish as indicated Pressed on 12 mm thick marine plywood complying to IS 710 Joints if any, shall be 4mm wide and shall be finished with matching veneer. Marine plywood for straight paneling and flexi ply for curvilinear paneling. Mounted on framework of aluminium hollow sections of 1.2 mm in thickness, not less than 50mm x 50mm in size and not more than 600mm spacing both ways as applicable. Structural Stability Certificate and Design to be submitted for all partitions. All Aluminium Framework should be anchored to the RCC Slab below and RCC Slab above. All Metal Partitions to be fixed in Screw system or Nut and Bolt System with slotted angles for Ceiling slab. No Welding is allowed. All should be prefabricated and assembled on site. Aluminium Framework with Fire rated Flexi Ply at curved spaces and Fire Rated BWP ply for straight Partitions. All framing should contain Acoustical Wool filling. General Physical Data: Flammability: BS 476 Part 4 (1970) Non-combustible Building Regulations: Class O Product Density: 45kg/m3 AMW50 is supported by chicken wire mesh stapled to joist sides, the insulation to provide one-hour fire rating without reducing the soundproofing properties of the product. Sound Reduction Obtainable: AMW50: 1.40 (SPACE - 100mm thk)
False ceiling - Item will be executed as as per drawing and specifications
1. 50mm x 50mm x 1.2mm Aluminium Frame Work in 600mm x 600mm Grid fixed to the Slab with GI L angle with support of soffit cleat and Gyproc Rawl Plug or equivalent. 2. 12mm th. Fire Rated Ply fixed to the Ceiling . 3. 19mm th. OSB Panel fixed to the Ply Ceiling. 4. Finish of OSB is clear lacquered finish. 5. All hardware to be ISI mark Grade. 6. OSB to Ply fixing with Fire Rated Glue Hitec Make or equivalent. The Acoustical felt board shall be 12.5mm thick and suspension system shall be galvanized steel framework suspenders of suspended GWB ceiling features shall be 12mm dia threaded rods finished in black color. Finishing accessories such as tapes and jointing compounds etc., as per specification , Including coordination with and assistance to MEP contractors for making cut-outs, supports for mounting light fixtures, HVAC grilles and support systems for heavy ceiling suspended interior components Plywood used for backing in coves and for MEP fixtures shall be marine grade. Finish to be Water Based PU Matt Finish. As per FFE-VN-01 ID-1005
1. 50mm x 50mm x 1.2mm Aluminium Frame Work in 600mm x 600mm Grid fixed to the Slab with GI L angle with support of soffit cleat and Gyproc Rawl Plug or equivalent. 2. 12mm th. Fire Rated Ply fixed to the Ceiling . 3. Acoustical Felt Boards to be fixed to the Ply. 5. All hardware to be ISI mark Grade. 6. Acoustical Felt to Ply fixing with Bostic Glue. The Acoustical felt board shall be 12.5mm thick and suspension system shall be galvanized steel framework suspenders of suspended GWB ceiling features shall be 12mm dia threaded rods finished in black color. Finishing accessories such as tapes and jointing compounds etc., as per specification , Including coordination with and assistance to MEP contractors for making cut-outs, supports for mounting light fixtures, HVAC grilles and support systems for heavy ceiling suspended interior components. Plywood used for backing in coves and for MEP fixtures shall be marine grade. Finish is black color felt. Ref: Drg ID-1005
Gyproc Ceiling with Perimeter, Channels, cleats, suspenders fixed to the slab ceiling with anchor fasteners. Gypsum Board of 12.5mm th. Fixed to the GI channels, which are connected to the perimeter along the walls. Z 120 Galvanised Steel framework and suspension system complying with IS 4326 (code for seismic design) for execution & to be approved by the Structural Consultant & Engineer-in Charge . Ref: Drg ID-1005 ID-1005
12mm thick Fire Rated Ply with Black Laminte on one side. Cove light to be fixed with Aluminium Framing suspended from the Slab Bottom. Ref: Drg ID-1005
Fixed joinery / Door / window / structural Glazing
Providing and Fixing 40mm thk. Flush Door with Laminate Finish on both sides. The Door should have the following ironomonger. The door should have wooden lippping on all the sides. 3 no. of Hinges and ironomongery as per detail drawing. work to be carried out as per Drg ID 5002 1. Flush Door - 40mm th. 2. Steam Beech Hardwood Frame. 3. Enox or equivalent hardware. 4. 1.5mm Laminate on both the sides. (STORE DOOR)
Providing and Fixing 12mm th. Toughened Curved Double Glass Door as per detail drawings. Ironomongery to be: 1. Floor Spring. 2. Floor Maching and Cover Plate system. 3. Locking system. 4. Glass to Glass Pivot on the top. 5. Handle. 6. Door Stopper. work to be carried out as per Drg. ID 5002 (GLASS DOUBLE DOOR)
Providing and Fixing 12mm th. Toughened Curved Fixed Glass Panel as per detail drawings. Ironomongery to be: Fixing system on the ceiling : SS Channel with Silicon and all required to hold the glass. work to be carried out AS PER DRG ID 5002(FIXED GLASS CURVED)
Providing and Fixing Centre Table as per the detail drawing. The Finishes to be veneer. AS PER DRG ID 5011
Providing and Fixing Stepped Seating as per Detail drawing. Structural Design to be submitted along with the shop drawings. Finish of the Steps to be in Veneer open grain Laquer finish. AS PER DRG ID 5003
Providing and Fixing Ply Boxing Platform for Potted Plants. Boxing to be made of 19mm th. Marine Ply with 4mm th. Veneer on exposed sides and 1.5mm th. Laminate on inside. Sizes and details to be as per detailed drawing. AS PER DRG ID 5004
Providing and fixing Canttilevered Ply Boxing finished in Veneer on exposed sides and Laminate on unexposed sides. The top to be with 10mm th.Toughened Glass with D Clamp fittings , and easy to remove for replacing the materials. All details and shape to be as per detailed drawings. STructural stability to be provided for the same.AS PER DRG ID 5005
Providing and Fixing Ply Boxing Platform for Potted Plants. Boxing to be made of 19mm th. Marine Ply with 4mm th. Veneer on exposed sides and 1.5mm th. Laminate on inside. Sizes and details to be as per detailed drawing. AS PER DRG ID 5006
Providing and fixing Canttilevered Ply Boxing finished in Veneer on exposed sides and Laminate on unexposed sides. The top to be with 10mm th.Toughened Glass with D Clamp fittings , and easy to remove for replacing the materials. All details and shape to be as per detailed drawings. STructural stability to be provided for the same. (UPTO 450mm DEEP) AS PER DRG ID 5005
Providing and fixing Canttilevered Ply Boxing finished in Veneer on exposed sides and Laminate on unexposed sides. The top to be with 10mm th.Toughened Glass with D Clamp fittings , and easy to remove for replacing the materials. All details and shape to be as per detailed drawings. STructural stability to be provided for the same.(UPTO 450mm DEEP) AS PER ID 5007
Providing and Fixing Pod Wings as per detail drawings. All Members to be anchored fastened to the floor. Structural stability design to be provided along with the shop drawings. As per DRG ID 5008
Signage and Displays
75"UHD Smart Professional Signage Display with Web OS, 500nits, 1000000:1 Dynamic Contrast Ratio , 24/7 operation, HDMI, DP, DVI-D, RS232, LAN,USB, WiFI, Screen share, 8GB inbuilt Memory,IP5X Dust Proof Certified Design, Built-in Speakers, Narrow Bezel, Super Sign CMS compatibity, with 1.1 Ghz Quad Core CPU , Clear View with Non Anti glare Coating
32" FHD Smart Professional Signage Display with Web OS 6.0, 400 nits, 1000000:1 Dynamic Contrast Ratio , 24/7 operation, HDMI, RS232, LAN,USB, WiFI, Screen share, 8GB inbuilt Memory, Built-in Speakers, Super Sign CMS compatibity
Digital Signage Lic as per drawing and specifications.
SECTION B- ELECTRICAL WORKS DISTRIBUTION BOARD
SITC of LPDB as per specifications
SITC of ELDB as per specifcations
Only isntallation of cables from dia 4mm to 30mm
Cable End Termination for cable of following sizes
3C/3.5C/4Cx4 sq mm
3C/3.5C/4Cx6 sq mm
3C/3.5C/4Cx16/25 sq mm
CONDUIT
SITC of 25mm class B GI conduit as per specification
WIRING
Primary Light Point wiring as per specifications and drawings
Type-A secondary Light Point wiring as per specifications and drawings(up to 5 Mtr length)
Type-B secondary Light Point wiring as per specifications and drawings(up to 7 Mtr length)
Type-C secondary Light Point wiring as per specifications and drawings(up to 10 Mtr length)
Wiring for power point as per specifications and drawings
Lighting Fixtures
SITC of built in step pelmet 9.6w/meter 3000k dotlees flexible led profile with non dimmable driver for every 10 mtrs length(2 nos of driver)as per specications and drawings
SITC of built in cove pelmet 14.4w/meter 3000k dotlees flexible led profile with non dimmable driver for every 10 mtrs length(2 nos of driver)as per specications and drawings
SITC of recessed ceiling 12w 3000k pop-out type sob led down light fitting with non dimmable driver as per specications and drawings
SITC of suspended ceiling 21w/meter tunable white curved dotless up down led profile with non dimmable driver for every 5 mtrs length(26 nos of driver)as per specications and drawings
SITC of suspended ceiling 21w/meter tunable white curved dotless led down led profile mounted on vertical panels with non dimmable driver for every 5 mtrs length(15 nos of driver)as per specications and drawings
SITC of recessed ceiling 3w 30 degrees 3000k led down led in vertical panels with non dimmable driver as per specications and drawings
SITC of corner mounted 9.6w/meter tunable white dotless led profile with non dimmable driver for every 10 mtrs length(5 nos of driver) as per specications and drawings
SITC of recessed wall 2w 3000k led foot light with non dimmable driver.
SITC of recessed wall 15w 3000k diffused led down light with non dimmable driver as per specications and drawings
SITC of 1x11 watt Exit light as per specications and drawings
SITC of LED Type Porch Light as per specifications
SITC of switches, sockets including mild steel electro galvanised switch box,face plate etc. complete with earthing as per specifications and drawings
1# 6A Switch
1# 6/16A socket & 156 switch,
SITC of 8 SWG Cu bare wire for earthing as per specifications
Fire Alarm System
Supply, Installation, Testing & Commissioning of Automatic Analogue addressable smoke detector below false ceiling with auto floating sensitivity, mounting base LED, addressing rotary Switch to programme the detectors complete as required. Detector shall withstand temp. variation from 0 to 50 degree C. (UL 7th Edition Approved and NFPA compliant/ EN54 or latest amended upto date
Supply, Installation, Testing & Commissioning of ISI Marked 2 Core x 1.5 Sq.mm, Multistrand Copper, Shielded, Twisted pair, FRLS PVC insulated Armoured wires, laid on wall / slab or structure with necessary GI saddles & spacer at 0.5 meters interval. complete with Lugs, Cable Compression Glands, Cable tags and ferruling. scope shall also include required end termination using gland, lugs & required accessories. Colour - Red
SECTION-C- HVAC WORKS Dismantling, shifting, re-installation, testing and commissioning of Existing cassette AC including re-installation of compatible refrigerant pipe with 13 mm thick nitrile rubber insulation, drain pipe, cable, structural support etc as per site condition if required with arrangement of trap door of 600 X 600 mm in false ceiling corresponding to each unit to access the unit for future maintenance.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .