Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹3.5 L+₹3,055 (0.89%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | A. A. BROTHERS and SUPPLIERS L1 | Altaf Hussain Vaid L2 |
|---|---|---|---|---|---|
| 1.00 | Fabricating, supplying and erecting 8 metre long Fibre Reinforced Plastic (FRP) / Glass Reinforced Plastic (GRP) lighting pole ( Top 85 mm and Bottom 201 mm dia 6 mm thickness) , conical in shape and embedded type, manufactured from high-strength thermosetting polyester resin reinforced with E-glass fibres, produced by computer-controlled moulding / CNC process, having smooth external finish, uniform wall thickness and corrosion-resistant properties, suitable for outdoor installation.The pole shall be designed to withstand wind pressure as per IS 875 (Part-3) and shall have adequate mechanical strength, impact resistance and UV resistance, conforming to REC / CPWD electrical specifications and relevant IS standards.The item includes supply and fixing of factory-made double arm bracket, integral or separately mounted as per design, transportation, erection, alignment and embedding of pole in ground, proper setting, grouting/ramming of embedded portion, and all accessories required to complete the work, complete as required, as per approved drawings and directions of the Engineer-in-Charge. Polethickness6-9mm, Tolerance in Length+/ 40mm. Tolerance in Thickness+/-0.5mm.,GlassContent More than60%m,DieElectric Strength7.3kV/mm. Pole does not require earthing, Specific Gravity 1.3TO1.95 kg/cm2,TensileStrength200±50MPA,FlexuralStrength250± 50MPA,CompressiveStrength150±50MPA, Impact Resistance 250 ± 50KJ/M2,Water Absorption< 0.5%, Surface Colour Shade Polyurethane Paint of Shade-Aluminium, Charcoal or as per Client Requirement, Accessories: Junction Box/Side Arm/Tenon Mount Bracket, Hardware MS Zinc Passivated , Should with-stand high wind load upto50M/S with maximum deflection of 15%. TECHNICAL DETAILS-FOUNDATION Specification: Standard Shaft Burial Depth will be 1200 mm. | 5 | No | 48,500 ₹2,42,500 | 34,111 ₹1,70,555 Lowest |
| 2.00 | Supply, Installation, Testing & Commissioning of energy-efficient LED flood light of 200 Watt, suitable for installation on 8 metre long FRP pole above, having die-cast aluminium housing, toughened glass cover, IP-66 ingress protection, power factor ≥ 0.95, THD ≤ 10%, minimum luminous efficacy 120 lumens/Watt, CRI ≥ 70, correlated colour temperature 5700K (cool daylight), integral constant-current LED driver, and surge protection device of minimum 10 kV. The luminaire shall be LM-80 compliant LED package and TM-21 compliant lumen maintenance, ensuring minimum L70 life of 50,000 burning hours. It includes provision of mounting brackets/clamps, nuts, bolts and all accessories, internal wiring connections, testing, commissioning, focusing/aiming of luminaires to achieve uniform illumination, and commissioning to the satisfaction of the Engineer-in-Charge, complete in all respects and in conformity with relevant IS/IEC standards. Havell /Crompton/ Philips/ SYSKA/ OR Eq. Standard make | 10 | No | 6,500 ₹65,000 Lowest | 10,000 ₹1,00,000 |
| 3.00 | Excavating pit of required size for foundation of 8 metre long FRP / GRP lighting pole (embedded type) in all kinds of soil, including dressing of sides and ramming of bottom, disposing of surplus excavated earth within lead as directed. Providing and laying plain cement concrete (PCC) of suitable grade (minimum M-10 / 1:3:6) in foundation, placing and embedding the FRP / GRP pole in position, ensuring proper vertical alignment and plumb, filling around the embedded portion with PCC / approved material, compacting, curing, and restoring the surface to original condition, complete as required and as per drawings and directions of Engineer-in-Charge. | 5 | No | 4,500 ₹22,500 Lowest | 7,200 ₹36,000 |
| 4.00 | S.I.T & C of dust vermin and weather / flame proof out door compartmentalized single phase feeder pillar of suitable size made of 14 SWG M.S. sheet complete with the following:- 16 A DP MCB incomer,lock, Termination of incoming/outgoing cables with suitable sizes of ferrules & compression gland, | 5 | No | 2,700 ₹13,500 Lowest | 8,000 ₹40,000 |
Tender Value
₹4.8 L
EMD Value
₹9,540
Closing Date
30 Apr 2026, 1:00 pmClosed
Executive Engineer ED Bijbehara
Executive Engineer ED Bijbehara
Supply carriage installation testing and commissioning of FRP/GRP Poles 8 mtrs long at various padavs in connection with SANJY 2026
2026_PDD_307169_1
EDB/e-tender/02 of 2026-27
Open Tender
Electrical Works
Turn-key
30 days
Executive Engineer ED Bijbehara
Please refer Tender documents.
6 documents required · 6 mandatory
₹200
Executive Engineer ED Bijbehara
₹9,540
2 May 2026
2 Apr 2026
1 May 2026
2 Apr 2026
30 Apr 2026
2 Apr 2026
2 Apr 2026 - 28 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Fabricating, supplying and erecting 8 metre long Fibre Reinforced Plastic (FRP) / Glass Reinforced Plastic (GRP) lighting pole ( Top 85 mm and Bottom 201 mm dia 6 mm thickness) , conical in shape and embedded type, manufactured from high-strength thermosetting polyester resin reinforced with E-glass fibres, produced by computer-controlled moulding / CNC process, having smooth external finish, uniform wall thickness and corrosion-resistant properties, suitable for outdoor installation.The pole shall be designed to withstand wind pressure as per IS 875 (Part-3) and shall have adequate mechanical strength, impact resistance and UV resistance, conforming to REC / CPWD electrical specifications and relevant IS standards.The item includes supply and fixing of factory-made double arm bracket, integral or separately mounted as per design, transportation, erection, alignment and embedding of pole in ground, proper setting, grouting/ramming of embedded portion, and all accessories required to complete the work, complete as required, as per approved drawings and directions of the Engineer-in-Charge. Polethickness6-9mm, Tolerance in Length+/ 40mm. Tolerance in Thickness+/-0.5mm.,GlassContent More than60%m,DieElectric Strength7.3kV/mm. Pole does not require earthing, Specific Gravity 1.3TO1.95 kg/cm2,TensileStrength200±50MPA,FlexuralStrength250± 50MPA,CompressiveStrength150±50MPA, Impact Resistance 250 ± 50KJ/M2,Water Absorption< 0.5%, Surface Colour Shade Polyurethane Paint of Shade-Aluminium, Charcoal or as per Client Requirement, Accessories: Junction Box/Side Arm/Tenon Mount Bracket, Hardware MS Zinc Passivated , Should with-stand high wind load upto50M/S with maximum deflection of 15%. TECHNICAL DETAILS-FOUNDATION Specification: Standard Shaft Burial Depth will be 1200 mm. | 5 | No | - | - |
| 2 | Supply, Installation, Testing & Commissioning of energy-efficient LED flood light of 200 Watt, suitable for installation on 8 metre long FRP pole above, having die-cast aluminium housing, toughened glass cover, IP-66 ingress protection, power factor ≥ 0.95, THD ≤ 10%, minimum luminous efficacy 120 lumens/Watt, CRI ≥ 70, correlated colour temperature 5700K (cool daylight), integral constant-current LED driver, and surge protection device of minimum 10 kV. The luminaire shall be LM-80 compliant LED package and TM-21 compliant lumen maintenance, ensuring minimum L70 life of 50,000 burning hours. It includes provision of mounting brackets/clamps, nuts, bolts and all accessories, internal wiring connections, testing, commissioning, focusing/aiming of luminaires to achieve uniform illumination, and commissioning to the satisfaction of the Engineer-in-Charge, complete in all respects and in conformity with relevant IS/IEC standards. Havell /Crompton/ Philips/ SYSKA/ OR Eq. Standard make | 10 | No | - | - |
| 3 | Excavating pit of required size for foundation of 8 metre long FRP / GRP lighting pole (embedded type) in all kinds of soil, including dressing of sides and ramming of bottom, disposing of surplus excavated earth within lead as directed. Providing and laying plain cement concrete (PCC) of suitable grade (minimum M-10 / 1:3:6) in foundation, placing and embedding the FRP / GRP pole in position, ensuring proper vertical alignment and plumb, filling around the embedded portion with PCC / approved material, compacting, curing, and restoring the surface to original condition, complete as required and as per drawings and directions of Engineer-in-Charge. | 5 | No | - | - |
| 4 | S.I.T & C of dust vermin and weather / flame proof out door compartmentalized single phase feeder pillar of suitable size made of 14 SWG M.S. sheet complete with the following:- 16 A DP MCB incomer,lock, Termination of incoming/outgoing cables with suitable sizes of ferrules & compression gland, | 5 | No | - | - |
stage.html
html • 0.02 MB
finance_996691.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.35 MB
SBD.pdf
Tender Documents • 1.07 MB
StandardDrawings.pdf
Other Document • 36.45 MB
technicalspecifications.pdf
Additional Documents • 5.25 MB
BOQ_996691.xls
BOQ • 0.32 MB
Extension02.pdf
PDF • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .