Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹37.4 L+₹2.0 L (5.53%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹38.2 L+₹2.8 L (7.76%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
17 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bhopal
GE Bhopal, Bairagarh, Bhopal
REPAIR REPLACEMENT OF LT CABLE AND MAINT OF EXTERNAL LT ELECT SUPPLY STREET LIGHT SECURITY LIGHT SOLAR LIGHT REPAIR REPLACEMENT OF EXTERNAL WATER SUPPLY PUMP REWINDING OF MOTOR REPAIR REPLACEMENT OF SEWAGE LINE CLEANING OF SEWAGE LINE SEPTIC TANK
2022_MES_539981_1
8907/E8
Open Tender
Civil Works
Item Rate
274 days
Itarsi
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Bhopal
₹99,000
Yes
22 Sept 2022
22 Jul 2022
19 Aug 2022
22 Jul 2022
17 Aug 2022
5 Aug 2022
Amount
This work comprises of (i) Repair / replacement of LT cable and maint of external LT electric supply and repair and replacement of street lights, security lights and solar light at Technical Area CPE Itarsi. (ii) Repair / replacement of damaged sewage line, cleaning of sewage line, septic tank, manholes at Technical Area CPE Itarsi. (iii) Repair and Replacement of External water supply, Pump and rewinding of motors at Technical area CPE Itarsi. The qty of individual part shall not vary beyond deviation limit specified in tender. Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline (iii) Earth work of any part will be measures under appropriate item of schedule
Repair / replacement of LT cable and maint of external LT electric supply and repair and replacement of street lights, security lights and solar light at Technical Area CPE Itarsi.
M&L for hinges and welding to LT panel board, complete all as specified and directed.
M&L for replacement of pannel door of with 3 mm thick CRCA sheet as per exisitng size to match with the existing panel and welding hinges and fixing complete all as specified and directed.
M&L for painting of existing LT panel board with spray gun with synthetic enamel paint to match with the existing surface complete all as specified and directed.
M&L for replacment of old burnt out aluminium bus bar and connected links of LT panel board, current rating 200 Amps as per existing size incl replacement of old rusted nut&bolts, washers complete all as specified and directed.
M&L for replacment of old burnt out copper bus bar and connected links of panel board, current rating 63/100/200 Amps as per existing size incl replacement of old rusted nut&bolts, washers complete all as specified and directed.
S&F indicators LED type complete all as specified and directed.
S&F Ampere meter Digital type type0-25 Ampsquare type flush panel mounted complete all as specified and directed.
S&F Volt meter digital type 0-500 Volt 96 sqmm square type flush panel mounted complete all as specified and directed.
Taking out/down unserviceable, defective cable any Type/size including disconnecting all the electrical connections all as required at site complete all as specified and directed.
Materials and replacement of 1100 volts grade heavy duty XLPE cable of following size , with aluminium conductor stranded polyethylene insulated, conductor served with and including sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC seathed, passing through GI pipe, in trench, on pole complete all as specified and directed.
(a) 120 Sqmm 3 ½ core
(b 70 Sqmm 3 ½ core.
( c) 50 sqmm 3 ½ core
(d) 35 sqmm 3 ½ core
( e)25 Sqmm 4 core
(f) 16 sqmm 4 core
(g) 16 sqmm 2 core
S & F in repair of aluminum lugs followimg suitable size complete all as specified and directed .
(a) 16 sqmm
(b) 35 Sqmm
(c) 50 Sqmm
(d) 70 Sqmm
(e) 95 Sqmm
(f ) 120 Sqmm
Supply, jointing, testing end termination jointing kit cold shrinkable out door type, suitable for LT 1100 Volts grade cable of following size complete all as specified and directed.
(a) 70 to 120 Sqmm 3.5 core
(b) 25 to 50 Sqmm 3.5 core
Supply, jointing, testing straight through jointing kit cold shrinkable out door type, suitable for LT 1100 Volts grade cable of following size complete all as specified and directed.
(a) 120 Sqmm 3 ½ core
(b) 70 Sqmm 3.5 core
(c) 50 Sqmm 3.5 core
(d) 35 sqmm 3 ½ core
Taking down old GI cable protection pipe 80/50/40 mm dia complete from wall, road crosing, pole etc, complete all as specified and directed.
Material and labour of GI pipe light grade of following side with all fittings and fixed complete to wall, to pole or laid in trenches and road crossing complete all as specified and directed.
(a) 80 mm dia
(b) 50mm dia
(c) 40 mm dia
Excavation in trenches in any type of soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out for foundation of pole, laying under ground cables etc and getting out complete all as specified and directed.
M&L for road cutting, PCC hard standing including excavation for laying of GI pipe 80/50/40 mm dia, and making good the disturbed surfaces all as per existing surface, complete all as specified and directed.
Material and labour sand filling in trenches for cable cushioning with clean, dry and unwashed sand free from sharp particles including gently punning around cable complete all as specified and directed.
Material and labour Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all as specified and directed.
Returning filling in with the earth obtained from above item including spreading, levelling, watering and well ramming in layers and not exceeding 25 cm in layer complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 Mtr and deposting where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
Stretching/restringing of ACSR conductor LT over head line of 4/6/8 wire run conductor comprising of any size on existing pole after opening from insulator by taking out of binding wire and refixing the same with suitable size of binding wire upto permissible sag after restringing including cutting of tree branches and trimming of tree branches of any size up to 2 Mtr each side of OH line which touch / fouling the OH line without damaging the same, complete all as specified and directed.
Supply and Fixing PVC line spacer/separator for LT over head line for 2 wire, 3 wire, 4 wire and 5 wire complete as per ground requirement complete all as specified and directed.
Material and labour for painting to steel tubular pole with aluminium enamel paint of 9.00 Mtr including cross arms, clamps any size and nuts, bolts etc with one coat of aluminium synthetic enamel paint including preparing the surfaces free from finish partical sand making the smooth surface and numbering on pole with black ground such as pole number and source of supply, painting with radium paint around the pole at width of 10cm, similar three rounds from 1.5 m GL top on circumferance of pole complete all as specified and directed.
Dismantling insulators LT any type and any size complete all as specified and directed.
Material and labour shackle insulator porcelain vitreous white or brown insulator working pressure 1100 volts including galvnised mild steel straps of size 31X 3 mm and 12 mm dia insulator bolts, washers and nuts etc complete all as specified and directed.
Material and labour pin type insulator of size 100 mm height, 65 mm dia porcelain vitreous white or brown/green insulator for working pressure 1100 volts with one galvanised spindle and two galvanised iron washers and nut complete all as specified and directed.
Dismantling of stay assembly complete to steel tubeler pole / PCC pole incl demolition of PCC concrete complete all as specified and directed.
Supply and fixing in replacement stay assembly complete with comprising of galvanised iron stay bow of size 40 cm X14 cm, 20 mm dia & 1800 mm long GI stay rod including GI nuts MS stay plate 300 mm X 300 mm X 6 mm, 2 No thimble, 50X6 mm flat iron stay clamp, 16 mm dia bolts , nuts and washers etc complete all as shown in electrical plate No 1 of MES SSR 1991 Part 1, complete all as specified and directed. Note:- Excavation and PCC, shall be measured and paid seperately .
Supply and fixing loop type insulator for stay assembly, porcelain vitreous of size 90 X 140 mm of clearance hole 25.5 mm complete all as specified and directed.
Dismantling cross arms of MS channel or angle sections etc. complete from steel /RCC poles, complete all as specified and directed.
Material and labour MS structure ( Fe-310-00 or Fe-410-00 ) such as MS flat, angle, channel etc in cross arm brackets, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as directed and including two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M&L of repair & replacement of Anti-climbing device; spikes typefabricated out of M.S. bars (round,square and flat) including nuts,bolts, washers and welding in twohalves made to shape to suit thecross section of the pole, complete all as specified and directed.
Material and labour PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M & L PCC 1:3:6 type C-1 using 20 mm graded stone aggregate cast in position as in coping (for packing of steel structure above ground level) including necessary use of form work and fair finish to exposed surfaces complete all as specified and directed.
Dismantling of UNSV LT tubular pole after taking down ACSR conductor, insulators cross arms including breaking PCC up to ground level etc, complete all as specified and directed.
M&L for Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screw as specified type 410 SP-31 (9.00 meters long) incl two coats of silver paint over a one coat of redoxide paint complete as specified and as directed incl taking out old unserviceale PCC pole complete all as specified and directed. (Excavation, foundation concrete, preservative treatment etc will be measured and paid separately)
Dismantling of ACSR conductor of any size from over head line LT poles removing from site complete all as specified and directed.
Material and labour ACSR conductor of any size fixing to insulator with necessary binding wire of suitable size complete all as specified and directed. Note: 3% extra shall be added to the weight for sagging, jointing, jumpers,etc, complete all as specified and directed.
Taking down unsv GI earth wire and guarding wire and remove from site complete all as specified and directed.
Material and labour replacement of galvanised steel continuous earth wire of size 4mm dia for earth continuty conductor complete all as directed.
Material and labour replacement of GI cradle guard hexagonal/rectangular with galvanised steel wire of 4mm dia complete all as specified and directed.
Taking down old Main switch/switch fuse unit any type TPN 200/100 Amps from poles/ LT panel board and removing from site complete all as specified and directed.
M&L for replacement of Switch fuse unit heavy duty, including Sheet metal enclosure with TPN of 100 Amp capacity complete all as specified and directed.
M&L for replacement of Switch fuse unit heavy duty, including Sheet metal enclosure with TPN of 200 Amp capacity complete all as specified and directed.
M&L in replacement of MCCB following capasity 415 Volts, breaking capacity 35 KA, fixed thrmal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder piller box including connecting lugs with busbar and including mounting arrengments e.i. screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed.
(a) 400 Amp , 4 Pole
(b) 350 Amp, 4 Pole
(c) 200 Amp , 4 Pole
(d) 160 Amp , 4 Pole
M&L in replacement of MCCB following capasity 415 Volts, breaking capacity 10 KA, fixed thrmal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder piller box including connecting lugs with busbar and including mounting arrengments e.i. screws,bolt, nut, washers incl taking out old unsv complete.
S&F in repair on load change over switch of following capasity . With S S Enclosure including taking down unserviceable one complete all as specified and directed.
(a) 100Amps 4 pole 415 volts 50 Hz
(b) 200 Amp , 4 Pole, 415 volt 50 Hz
(c) 400 Amo , 4 Pole, 415 volt 50 HZ
M&L for Earthing complete for various LT feder piller box, DG set, Transformer and Pump sets with galvanised earth plate electrod 600 x 600 x 6 mm thick burrieed directly in the (earth pit not less then 2.25mtr deep bellow ground level) with top edge of eath plate not less then 1.5mtr bellow the ground level, connected to galvanised iron strip 32X 6mm by means of bolts, nuts, chuck nuts and washers of galvanised iron or steel, GI pipe 40mm bore light gread for protection of earthing strip and water pipe of 20mm dia, upto earth plate, PCC chamber 1:4:8 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 12mm thick plaster in cement mortor 1:4, funnel with wire mess of 22 gauge (0.63) 8 mess per liner inch, 50mm thick cover of RCC 1:2:4 type B-1, using 20mm graded stone aggregate reinfoced with 8mm TMT bar at 100mm center to center both ways and charcoal dust and common salt all as shown in electrical plate No.3 of MES SSR Part-I and as specified including excavation and earth work and connecting the earthing to an earthing test point as specified and testing on complete all as directed incl taking out old unsv complete. Note: unit rate quoted is inclusive of earth strip and protection pipe upto 7.5 mtr from earth plate. (Qty for Job LT cable =04, Qty for job Ext W/S=02)
Cutting of unwanted tree branches distrubing of over head lines, 2meter clear and vegetation, bushes, small plants, srubs around the electric pole, in side installation, under the electric over head lines, disposing of unwanted material not exc 50 Mtr away from the site and putting the same in low laying area complete all as specified and directed.
S&F in replacement of 1100 Volts grade heavy duty service line cable PVC insulated aluminium conductor, twin core cable, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more that 1 metere apart including 4 mm suspension wire, one twin core cable flat or cicrular of aluminium condoctors size 10 Sqmm stranded conductor all as directed incl taking down old unsv complete all as specified and directed.
Supply, replacement, installation, testing and commissioning of automatic power factor correction pannel for 3 phase 415V &50 Hz system of capasity 50 KVAR, factory made, out door type both side opening, (frount and rear side) weather and vermin proof panel having degree of protection IP-43 & made out of CRCA fabricated out of sheet of 3.15 mm outer structure and 1.6mm for internal structure with duly powder coated,CPRI approved , factory made fabricated and CPRI approved, 415 volts, with locking arrangement, powder coated MS angle iron base frame with legs of size 40 X 40 X 60mm and 60cm long grounted with PCC 1:3:6 type C-1 for foundation filling with platform 100 X 75 X 15 cm above ground level floor incuding Cable connection with appropriate MCCB & MCB, complete all as specified and directed.
Supply and install in repair and Replacement of capacitor, metalized poly propylene heavy duty (MPP-H) three phase, 415 volts and 50 Hz system for permissible non-linear load 15 % of of following capacity to maintain power factor including taking down unserviceable one complete all as specified and directed.
(a)10 KVAR
(b) 15 KVAR
(c) 25 KVAR
M&L for replacement of CT coil of LT panel as per existing ratio complete all as specified and directed.
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of aluminium conductor size 10 sqmm (Stranded conductor) complete all as specified and directed
Taking down unserviceable Street/Security light fitting of any type from the pole and fixing after completion of repairs complete all as specified and directed. (Note: Repair/replacement of spares shall be measured seperately)
Supply and fixing in replacement of electronic driver of following capacity of existing make for LED street light fitting complete all as specified and directed:-
(a) 30 to 35 watt
(b) 60 watt
(c) 70 watt
(d) 90 watt
M&L in replacment of 1100 Volts grade, heavy duty cable, PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed for street light connections cable flat or cicrular of size 6 Sqmm twin core cable stranded conductor complete all as directed incl taking down old unsv complete all as specified and directed.
Supply and fixing in replacement of LED street light fitting of following capasity, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection include ltaking down old unsv street light complete all as specified and directed.
(a) 35 Watt
(b) 60 Watt
(c) 70 watt
(d) 90 watt
Supply and fixing LED flood light of following capacity outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp include taking down old unsv street light complete all as specified and directed:-
(a) 70 watt
(b) 120 watt
M&L for taking down mini High Mast head (8/9 mtr) carefully by manually/mechanically and checking the continuity of cable & light light fittings and replace the unsv light fittings/copper cable complete all as specified and directed. Note: Light fittings and copper cable will be paid under relevent items
Supply and fix in repair and replacement of Solar street light LED type fittings (With inbuilt CCU) 1x26 Watt made out of pressure dia cast aluminium, with IP-66 protection including all control driver and LED lamps suitable for Solar street pole including 9.00 mtr Steel Pole suitable for light fitting complete including taking down the existing unserviceable solar light fittings of any capacity and removing from the site complete all as directed and specified. (NOTE- Earth work is icluted in quoated rate)
M&L in replacment of 1100 Volts grade, heavy duty cable, PVC insulated copper cable, served with inner sheathing of PVC tape and overall PVC sheathed for hight mast light connection cicrular of size 2.5 Sqmm three core cable stranded conductor complete all as directed incl taking down old unsv complete all as specified and directed.
Supply and fix in GI bracket for street light of following dia medium grade for mounting bracket bent to shape 1.75 meter length and fixing arrangement with two Nos of MS clamps set, nut, bolts, washers, and applying two coats of aluminium paints over one coat of Zinc oxide primer complete all as directed incl taking down old unsv complete all as specified and directed:-
(a) 50 mm dia
(b) 40 mm dia
Supply and fix in replacment of pole mounted junction box (sintex box) size 340 X 160 X 90 mm with porcelain connector 2 Nos, colour coaded aluminium bus bar of rating 63 amps mounted on non cracking epoxy insulators, MCB SP 10Amps, 250 volts, 'C' curve - 02 Nos. Mounted in including provisioning of mounting arrangements with clamps, nut, bolts, and washer etc for fixing to pole, drilling with proper hole for incoming and outgoing cables of suitable size , conecting existing cables with bus bar complete all as directed incl taking down old unsv complete all as specified and directed.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Repair / replacement of damaged sewage line, cleaning of sewage line, septic tank, manholes at Technical Area CPE Itarsi.
M&L for attending /cleaning daily complaints of blockage of floor traps, WCs (Indian/European) WHB traps, kitchen traps, urinal traps etc at ground floor or above ground floors with and including necessary T&P as required for this purpose :- Note : (a) Complaint slip shall collected by the contractor/supervisor from MES complaint cell and submit the same duly signed by the occupant at 1630hrs in the complaint cell. It will be responsibility of contractor to ensure their attendance & completion of complaints. (b) If any complaint not resolved within 24 hrs the recovery @ Rs 500 per complaint per day will be charged from RAR or Final Bill. (c) During cleaning of blockage remove grating will be refixed in existing position with white/grey cement afterclearing of blockage from trapes. (d) The contractor will ensure the cleaning /cleaning of all the complaints (Irrespective of Nos) within 24 hrs by deploying additional sewer man /safaiwalaif needed. Nothing extra charge will be paid on this account (e) Contractor shall be solely responsible for supplying all the safety measures required by the sewer man/safaiwala during working hours. (f) All the waste material/dludge shall be disposed of out of MoD land.
Taking out RCC cover slab of septic tank of 100 users capacity carefully, taking out the sludge including foul water, collect the sludge in closed container and burried the same in earth pit below 30 cm of the gound level with in the defence land where directed by the Engineer-in-charge to a distance exc 250 m and n.exc 500 m, returning, filling in the earth in excavated pit after complete removal of sludge from the container, inlet and outlet pipe, M.S ring and septic tank complete cleaning with fresh water as directed and placing the RCC cover slab in position and set in CM 1:6 complete all as specified and directed
Taking out RCC cover slab of septic tank of 50 users capacity carefully, taking out the sludge including foul water, collect the sludge in closed container and burried the same in earth pit below 30 cm of the gound level with in the defence land where directed by the Engineer-in-charge to a distance exc 250 m and n.exc 500 m, returning, filling in the earth in excavated pit after complete removal of sludge from the container, inlet and outlet pipe, M.S ring and septic tank complete cleaning with fresh water as directed and placing the RCC cover slab in position and set in CM 1:6 complete all as specified and directed
Taking out RCC cover slab of septic tank of 25 users capacity carefully, taking out the sludge including foul water, collect the sludge in closed container and burried the same in earth pit below 30 cm of the gound level with in the defence land where directed by the Engineer-in-charge to a distance exc 250 m and n.exc 500 m, returning, filling in the earth in excavated pit after complete removal of sludge from the container, inlet and outlet pipe, M.S ring and septic tank complete cleaning with fresh water as directed and placing the RCC cover slab in position and set in CM 1:6 complete all as specified and directed
Cleaning of man holes of any size depth n.exc 60 cm to cleaned all as per item 68.00 here in before complete all as specified and as directed.
Cleaning of man holes of any size depth exc 60 cm and n.exc 1.20 mtr cleaned all as per item 68.00 here in before complete all as specified and as directed.
Cleaning man holes of any size depth exc 1.20 sqm cleaned all as specified all as per item No 68.00 here in before complete all as specified and directed.
M&L for dewatering/ Desludging of existing main sewage receiving tank of size 6mdia and 5 m deep (inner tank and outer tank) by sewage suction machine truck mounted equipped with sewage storage tank and dispose off foul material/sludge out side the defence land on the location enmarked by civil authorities complete all as specified and directed.
Dewatering/Desludding from existing soakage well of size 2.4 M dia X 3.0M deep by sewage suction machine truck mounting equipped with sewage storage tank and removing/dispose off foul material/sludge out side the defence land on the location enmarked by civil authorities complete all as specified and directed.
Dewatering/Desludding from existing soakage well of size 1.8 M dia X 3.0M deep by sewage suction machine truck mounting equipped with sewage storage tank and removing/dispose off foul material/sludge out side the defence land on the location enmarked by civil authorities complete all as specified and directed.
Dewatering/Desludding from existing soakage well of size 1.2 M dia X 3.0M deep by sewage suction machine truck mounting equipped with sewage storage tank and removing/dispose off foul material/sludge out side the defence land on the location enmarked by civil authorities complete all as specified and directed.
Material and labour loose filling with aggregate of guage 80 mm to 150 mm as in soak well /sokage pits /filter beds with broken bricks incl removed old brick bats complete all as specified and directed.
M&L for Cleaning of chocked sewage line of any description and any dia from man hole to man hole with sewage cleaning rod washing down with fresh water and disposed off the sludge all as specified and directed . The complaint where cleaning is not possible by rodding and is to be cleared by braking existing line the item will be paid separetely in item herein after, complete all as specified and directed.
M&L for cleaning of underground sewage lines of 150mm bore by excavation and breaking (Minimum two length) and removing the blockage, laying new pipes, re-joining with old pipes including haunching the new pipes with PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) in all situations where cleaning is not possible otherwise including returning, filling and disposal of surplus soil outside MoD land etc. complete all as specified and directed.
Demolition of PCC in ground floors and paving not exc 15cm thickness (below or above ground level) complete all as specified and directed.
Material and labour for 75mm thick PCC 1:3:6 type C-1 (using 20mm graded aggregate) as in pavement/plinth protection, plinth protection shall be laid in alternate bays and joints shall be filled with bitumastic gola with 80/25 bitumen (1 part bitumen mixed with 3 part of sand) surface finished fair and even complete all as specified and directed.
Demolition of reinforced cement concrete of any description as in man hole / septic tank cover slabs in any position complete all as specified and directed.
M&L for precast reinforced cement concrete type B1, (1:2:4) with using (20 mm graded stone aggregate) as in man hole / soak well cover slab set in CM 1:4 complete all as specified and directed.
M&L RCC type B-1 (1:2:4) using 20 mm grades aggregate as in slabs as in septic tank cover slab set in CM 1:4 complete all as specified and directed.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
M&L for Cement plaster 10 mm thick in cement mortar 1:4 on concrete surface such as soffits of RCC, chajja, roof projection columns and beams etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wires (annealed) not less than 0.9 mm dia or secured with clips complete all as specified and as directed.
All as per item No 88.00 here in before but 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed.
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc. complete all as specified and as directed.
M&L for brick work with fly ash bricks built in CM (1:6) straight or curved on plan exc 6m mean radius as in manholes etc. complete all as specified and directed.
Material and labour for Brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Material and labour for Brickwork with fly ash bricks in one brick thick honey comb walling, built in CM 1:4 as in soak well complete all as specified and directed.
Taking down cement plaster of any description on brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick wall mixing with water proofing compound as per manufacturer instruction (Water proofing compound paid for seperately) of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement as in man hole/ septic tank etc, complete all as specified and directed.
Supply only intregal water proofing compound
M&L for rendering 15 mm thick on fair faces of concrete/brick wall surface in cement mortar 1:4 and finishing the surface even and smooth without using extra cement complete all as specified and directed.
Dismantling of SGSW drain pipes/NP-2 pipe of any bore jointed in cement mortar of any size and description including concrete bed and packing/ haunching of any type, complete all as specified and directed.
M&L for sail-glazed stoneware drain pipes of Internal diameter of pipe in 150mm laid in trenches and jointed complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation etc, complete all as specified and directed.
M&L 200mm dia RCC pipes class NP-2 laid in trenches and jointed with cement mortar and tested complete all as specified and directed.
M&L for Concrete bed to drain pipe incl. packing under hanching against the side of pipes, 150mm, in cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) after laying and testing of pipe complete all as specified and directed.
M&L for Concrete bed to drain pipe incl. packing under hanching against the side of pipes, 200 mm bore, in cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) after laying and testing of pipe complete all as specified and directed.
M&L for cement conctete type B-1, 1:2:4 as in benching and coping complete all as specified and as directed.
S&F 100mm dia. Cast iron soil waste and vent pipes (Sand cast pipe), in any length with or without ears, with cement joints, fixed to wall/floor etc incl demolition of existing pipe complete all as specified and directed.
S&F 75mm dia. Cast iron soil waste and vent pipes ( Sand cast pipe), in any length with or without ears, with cement joints, fixed to wall/floor etc complete all as specified and directed.
S&F in repair viteress china squtting pan "ORISSA PATTERN" size 580x440mm white with integral foot rest and flush pipe complete including provision of concrete bedding 1:2:4 type BO, complete all as specified and directed.
Supply and fixing in repair Vitreous china EWC 'P' or 'S' Trap , white including Plastic water closet seat cover, white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device suitable for EWC. Complete making good to floor fixing bolt complete all as specified and directed.
M&L for non skid coloured ceramic edge cut tiles 7-8mm thick (square/ rectangular) area of each tile exceeding 0.06sqm but n.exceeding 0.11sqm as in floors set & jointed in neat cement slurry & pointed in white or coloured cement to match the tiles over including screed bed 15mm thick in cement mortar (1:4) for laying floor finished complete all as specified and directed.
S&F 100mm dia CI bend, complete all as specified and directed.
S&F branch pieces (equal or unequal) or double parallel branches (100mm dia.) complete all as specified and directed.
S&F socket 100mm dia. (double coller) complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm dia. single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed.
S&F PVC (SWR) bend 110 mm dia with access door complete all as specified and as directed.
S&F PVC (SWR) bend 110 mm dia without access door complete all as specified and as directed.
S&F PVC (SWR) junction single 110 mm bore, (single T) equal or unequal with access door complete all as specified and as directed.
S&F PVC (SWR) 110mm bore vent cowl complete all as specified and as directed.
S&F PVC (SWR) pipes 75 mm dia. single socketed, in any length with rubber ring joints, fixed to wall incl demolation of existing pipe complete all as specified and as directed.
S&F PVC (SWR) bend 75 mm dia with access door complete all as specified and as directed.
S&F PVC (SWR) bend 75 mm dia without access door complete all as specified and as directed.
S&F PVC (SWR) 75 mm bore vent cowl complete all as specified and as directed.
S&F cast iron floor trap 100 mm dia with gratings includings jointing to waste pipe fixed in cement concrete type B-1 1:2:4 complete all as specified and as directed.
S&F cast iron floor trap 75mm dia with gratings includings jointing to waste pipe fixed in cement concrete type B-1 1:2:4 complete all as specified and as directed.
S&F PVC (SWR) gully trap 125/110mm,setting and jointing with solvent cement concrete type B-1 1:2:4 complete all as specified and as directed.
S&F CI vent pipe 100mm dia with or without ears with cement joints laid in wall, complete all as specified and directed.
S&F CI cowls 100mm dia, complete all as specified and directed.
S&F CI Branch pipes 100mm (equal or unequal) with parellel branches, complete all as specified and directed.
Repair and Replacement of External water supply, Pump and rewinding of motors at Technical area CPE Itarsi.
Material and Labour for taking out of defective submersible pump set of capacity 10HP/12.5 HP of any make with column assembly of any size / capacity including disconnecting electrical and water line connection, lifting in with the help of chain pulley, clamp, tripod etc., and repairing, lowring and refixing the same after making it serviceable, rethreading of column pipe and replacement of worn out nuts, bolts washers, transportation of same from site to workshop and back etc., including test and commisionnig complete all as specified and directed. Note: (i) Defective spares parts for pump and column assembly shall be measured and paid separetely under relavent item. (ii) Cost of detaching the pump and motor removed and refixing after carry out the nessary repair shall be deemed to be included in the unit quated rate. (iii) After taking out submersible pump set the bidders shall cover the tube well imidiatly wihout any delay with cover/cap to avoid any accident and cots of covering the tube well shall be deemed to be included in the unit quated rate.
Material and labour for rewinding the submersiable motor of any make of capacity 10 to 12.5 HP with PVC insulated water proof conductor copper wire of best quality of existing gauge and turn with minimum weight of 1.2 Kg of copper wire per HP of motor and reassembling after replacement of bush, bearing sleeves, grinding as required and polishing of rotor shaft, repair to starter etc., and re fixing the same in existing position, test and commisionnig complete Including dismantling defective submersiable motor of any make complete all as specified and directed. Note:- Bush/bearing /sleeves/thrust plate shall be measured and paid separately under relavant items.
(a) Supply only bush/bearing (gun metal) of suitable size for 10/12.5 HP for the submersible motor complete all as directed.
(b) Supply only stainless steel sleeve of suitable size for 10/12.5 HP complete all as directed.
(c) Supply only thrust plate set 10/12.5 HP complete all as directed.
(d) Supply only thrust plate bearing housing
(e) Supply only rubber oil seal
Material and Labour for taking out of defective submersible pump set of capacity 7.5 HP of any make with column assembly of any size / capacity including disconnecting electrical and water line connection, lifting in with the help of chain pulley, clamp, tripod etc., and repairing, lowring and refixing the same after making it serviceable, rethreading of column pipe and replacement of worn out nuts, bolts washers, transportation of same from site to workshop and back etc., including test and commisionnig complete all as specified and directed. Note: (i) Defective spares parts for pump and column assembly shall be measured and paid separetely under relavent item. (ii) Cost of detaching the pump and motor removed and refixing after carry out the nessary repair shall be deemed to be included in the unit quated rate. (iii) After taking out submersible pump set the bidders shall cover the tube well imidiatly wihout any delay with cover/cap to avoid any accident and cots of covering the tube well shall be deemed to be included in the unit quated rate.
Material and labour for rewinding the submersiable motor of any make of capacity 7.5HP with PVC insulated water proof conductor copper wire of best quality of existing gauge and turn with minimum weight of 1.2 Kg of copper wire per HP of motor and reassembling after replacement of bush, bearing sleeves, grinding as required and polishing of rotor shaft, repair to starter etc., and re fixing the same in existing position, test and commisionnig complete Including dismantling defective submersiable motor of any make complete all as specified and directed. Note:- Bush/bearing /sleeves/thrust plate shall be measured and paid separately under relavant items.
(a) Supply only bush/bearing (gun metal) of suitable size for 7.5 HP for the submersible motor complete all as directed.
(b) Supply only stainless steel sleeve of suitable size for 7.5 HP complete all as directed.
(c) Supply only thrust plate set for 7.5 HP complete all as directed.
(d) Supply only thrust plate bearing housing for 7.5 HP complete all as directed.
(e) Supply only rubber oil seal for 7.5 HP complete all as directed.
Dismantling and opening of defective submersible pumping set having capacity up to 12.5 HP any stage/discharge and dismantling all spare parts by opening studs complete with machine/lathe ork/grinding/polishing and fitting of all spare parts and re-assembling installation in position after necessary repair / replacement of studs, nuts, bolts etc., including refixing the same after making it serviceable in its existing position including test and commisioning complete all as directed.o (Spare parts shall be measured & paid separately under respective items as under)
(a) Supply only submiersible pump bowl assembly of gun metal impeller
(b) Supply only submiersible intermediate bowl
(c) Supply only submiersible bowl bush (rubber)
(d) Supply only submiersible bowl bush (gun metal)
(e) Supply only submiersible cast iron impeller seal ring (neck ring)
(f) Supply only submiersible stainless steel running sleeves
(g) Supply only submiersible impellor locking keys stainless steel
(h) Supply only submiersible pump shaft 25.40 mm dia of any capacity
(j) Supply only rinning strainer for pump
Material and labour for taking out monblock Motor Set of capacity 3 H.P to 15 HP from position and transportation of same from site to workshop and back, dismantling of cable/ pipe connection and reinstallation of motor set after necessary repairing on the existing foundation and making electrical connections including necessary nuts, bolts, washers etc., required at site of work, complete all as specified & directed Note : All spares parts required shall be measured and paid for separately
(a) Ball Bearing of suitable size
(b) Rubber washer of suitable size
(c) Packing sheet of suitable size
(d) Bush cover of suitable size
(e) Mechanical Seal of suitable size
(f) Circlips Clamp of suitable size
Material and labour for taking out Centrifugal Pump of capacity 3 HP to 7.5 H.P and transportation of same from site to workshop and back, dismantling of cable/ pipe connection and reinstallation of pump set after repair on the existing foundation and making electrical connections complete all as specified and directed Note : All spares parts required shall be measured and paid for separately
(a) Pump overhauling GM bushes ,shaft rematteling making key gland packing,incl all engineering work.
(b) Pump shaft stainless steel of same make and model duly grinded/polished
(c) Bearing of suitable size of pump
(d) Plugging leaks in casing by welding the same incl grinding for smooth surface
Material and labour for rewinding of damaged/burnt motor of capacity 3 H.P to 7.5 H.P any type by using enamelled copper wire of superior quality of existing grade and same Nos. of turns including varnishing ‘F’ class insulation and drying in heat chamber / oven including all other material / fittings and testing on completion, complete all as specified & directed.
Supply and fixing in replacement of CI Non Return Sluice Valves, 100mm bore, ISI Marked flanged class 1.6 PN with by-pass arrangement and necessary bolts and nuts of suitable size with and including rubber gasket for flanged joints and testing including taking out old unserceable non return valves complete all as specified & directed.
Supply and fixing in replacement of CI Non Return Sluice Valves, 80mm bore, ISI Marked flanged class 1.6 PN with by-pass arrangement and necessary bolts and nuts of suitable size with and including rubber gasket for flanged joints and testing including taking out old unserceable non return valves complete all as specified & directed.
Supply and fixing in replacement ofGun metal Non Return Sluice Valves ISI Marked for 50 mm bore fixed with GI ppe and testing complete all as specified and directed
Supply and fixing in replacement of CI Sluice Valves ISI Marked flanged class 1.6 PN with necessary bolts and nuts of suitable size with and including rubber gasket for flanged joints and testing including taking out old unserviceable sluice valves complete of following sizes :-
(a) 200 mm bore
(b) 150 mm bore
(c) 100 mm bore
(d) 80 mm bore
Supply and fixing in replacement of Gun metal globe, Ball or gate valve class-2 with iron wheel head screwed both ends for pipes of following sizes complete including taking down old unserviceable gate valves all as specified and directed :-
(a) 50mm bore
(b) 40 mm bore
(c) 32 mm bore
(d) 25 mm bore
(e) 20 mm bore
(e)15 mm bore
Taking up or down GI tubing & connection incl cleaning for re fixing and removal to site of following sizes complete includingtaking taking down old unserviceable gate valves all as specified and directed :-
(a) 100 mm bore
(b) 80 mm bore
(c) 50 mm bre
(d) 40 mm bore
(e) 25 mm bore
(f) 20 mm bore
Supply and fixing in replacement of Galavised iron tubing (GI), medium grade, with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminshing pieces, caps, plugs and unions etc., laid in trenches / fixed to walls and ceilings or laid in floors, complete all as specified and as directed of the following description :-
(a) 100 mm bore
(b ) 80 mm bore
(c) 50 mm bre
(d) 40 mm bore
(e) 25 mm bore
(f) 20 mm bore
Taking up or down CI water mains Pipe (including all fitting) of following sizes with spigot and socket/both side flanged ends and lead joints including burning out joints and recovering lead all as specified and directed :-
(a) 200 mm bore
(b) 150 mm bore
(c ) 100 mm bre
(d) 80 mm bore
Supply and fixing in replacement of Cast Iron pipe with the follwing sizes with spigot and socket/both ends flanged centrifugally cast Class LA , in any length laid in trenches/Over Head Tank with all fittings such complete all as specified and as directed of the following description :-
(a) 200 mm bore
(b) 150 mm bore
(c) 100 mm bre
(d) 80 mm bore
Material & Labour in replacement of lowering GI pipe heavy class of size 50mm dai bore with long GI socket in 3 meter length incudling taking down old GI Pipe. Make- Jindal/Tata/Swasticcomplete all as directed by Eng-In- Charge. (Note- All T&P required for execution will we arranged by Contractor).
M&L in replacing Gland for pump set capacity 2 HP to 10 HP complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair 15mm dia stop valves, cast copper alloy, screwed down high pressure with crutch or buterfly handle, screwed both ends for iron pipe or union and fixed all as specified and as directed, including taking down.
Taking down existing air release valve and supply and fix in repair CI air release valve 80 mm bore, ISI marked , rubber gasket , mild steel nuts, and washers including testing complete all as specified and directed.
Material and labour for cleaning RCC overhead water storage tank of capacity 48000 Gallon taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation, remove honycomb on the wall of OHT if any and flushing after cleaning with water and bleaching powder, cleaning walls and floors by scratching with wire brushes and white wash to be carried out in the inner side of the tank and also writing the date of Cleaning and capacity of the tank using synthetic enamel paint on black ground and white paint complete all as specifed and directed. Note : The work will be completed within 24 hours after that the water will be supplied to the users.
Material and labour for cleaning under ground sump of capacity 30000 Gallon taking out sludge and depositing the same outside the Cantt area at a place meant for the purpose, removing all scale, dirt, algae, vegetation, remove honycomb on the wall of OHTif any and flushing after cleaning with water and bleaching powder, cleaning walls and floors by scratching with wire brushes and white wash to be carried out in the inner side of the tank and also writing the date of Cleaning and capacity of the tank using synthetic enamel paint on black ground and white paint complete all as specifed and directed. Note : The work will be completed within 24 hours after that the water will be supplied to the users.
Submersible flat cable PVC insulated and PVC sheathed LT 1100 volts grade with copper conductor of size 6 Sqmm 3 Core, complete all as specified and directed.
Material and labour run lead joint in wet/dry soil including removing necessary existing lead from the fittings of following sizes of pipes complete all as specified and directed. Note: Bidder should be ensure that any demages/casualities occured during removing the lead, bidder is the only responsible and no extra cost shall be deemed to quoted rate.
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
(d) 200 mm bore
Supply and replacement of MS flange with rubber gasket suitable for following sizes pipes to the existing make and system including nuts, bolts and washers complete all as directed.
(a) 50 mm dia pipe
(b) 80 mm dia pipe
(c) 100 mm dia pipe
S&F D joint alonwith rubber packing for CI pipe line for the following sizes including necessary excavation in wet condition cutting of pipes, stoping of water removing water and providing necessary extra fitting complete all as directed. Note: Earth work and D joint shall deemed to be included in the quoted rate and nothing extra shall be paid on this account.
(a) 80mm dia
(b) 100 mm dia
(c) 150mm dia
Cleaning the vegetation, rooting etc by spraying the water mixed chemical used for cultivation to avoid the grown up of vegetation etc complete all as directed. Note- Contractor shall ensure that on spraying of chemical vegetation shall be dried if not the same has to be carried out with out any extra cost to deperatment.
Material and labour for construction of valve pit chambers of size 600 X 600 X 600mm (internal dimensions) as under provided with 10 cm thick PCC 1:4:8 type D2 as in foundation over 15 cm thick hard core, 23 cm thick brick walls built in cement mortar 1:4, 15 mm thick internal plaster including top of floor, externally upto 150 mm below GL in CM 1:3 finished even and smooth without using extra cement, 3.00 mm thick MS sheet cover with 40 x 40 x 6 mm MS angle frame fixed in PCC 1:2:4 type B1, 50 mm thick coping with 25 x 6 mm flat iron hold fasts, hinges, handles, locking arrangements and applying 2 coats of syntheric enamel paint over acoat of red oxide primer to all steel surfaces and 3 coats of white wash to internal surfaces of chamber including excavation and earth work in any type of soil and removing of surplus soil to a distance not exceeding 50 m complete all as specified and directed.
All as per item No. 158.00 here in above but size 900 X 900 X 900mm, complete all as specified and directed.
Material and Labour for repair of leakage in the under ground GI pipe water line of following sizes including necessary excavation , dewatering with the kept of external pump and filling in wet condition, taking out of existing pipes/cutting of pipes, stoping of water, threading of pipes and providing of necessary GI fittings i.e. tee, elbow, socket, union if required complete all as directed. Note :- (i) GI fitting if required for stopping the leakage shall be supplied by the contractor without extra cost. (ii) Earth work for stoping the leckage shall be included in quoted rate (iii) The leakage will be rectified within 24 hours after that the penalty @ 500/- per day shall be imposed and deducted from contractors.
(a) 20mm to 32mm dia GI Pipe
(b) 40mm to 50 mm dia GI Pipe.
(c) 80mm to 100mm dia GI Pipe.
Material and labour for repair of leakage in the under ground CI pipe water line of following sizes including necessary excavation and filling in wet condition, taking out of existing pipes/cutting of pipes, stoping of water, threading of pipes and providing of necessary CI fittings if required complete all as directed. Note :- (i) Earth work for stoping the leackage deemed to be included in quoted rate by the contractor.(ii) The leakage will be rectified within 24 hours after that the penaltity charges @ 500/- per day deemed to the contractor.
(a) 80mm to 100 mm dia CI Pipe
(b) 150 mm dia CI Pipe.
(c) 200 mm dia CI Pipe.
Material and labour for cutting the existing cast iron pipe150/100 mm dia for inserting 20/25/40/50 mm dia GI pipe, drilling, welding, and screwing with nuts, bolts, and washers with mild steel clamps welded with GI socket 20/25/40/50 mm dia including excavation of earth work, removal of soil and RFR complete all as specified and directed
M&L in repair CI fittings confirming to IS for Spigot socket end pipes up to 200mm bore such as bends (any type, radius angle) Tapers any type(straight,bend,increasing,descreasing or double socket etc)T pieces,single branch,`Y` junction,double branch cross (all sockets or socket and spigot)collars, caps and plugs etc. complete all as specified and directed
Material and labour for High strength Calcium based granular chlorination chemical containing appropriate quantities of dispersants / corrosion inhibitors to prevent encrustation / scaling in distribution systems. The brand and make of the chlorination chemical must be stated and certified by All India Institute of Hygiene & Public Health (Govt. of India), confirming compliance to all the above specifications with a declaration from the laboratory that from the technical, strength, stability, health, safety, and operational point of view, as well as the fact that this product is used for drinking water applications for consumption by humans, the brand and make of Calcium based granular chlorination chemical is suitable for drinking water chlorination and is recommended for use. The report must indicate that the sample has been drawn by All India Institute of Hygiene & Public Health complete all as directed.
M&L for repair to sluice valve with new accessories as per requirement like spindle and check nuts of sluice valve including nuts, bolts and rubber sheet complete suitable for 80 mm to 100 mm sluice valves complete all as specified and directed
M&L for Repair to sluice valve with new accessories as per requirement like spindle and check nuts of sluice valve including nuts, bolts and rubber sheet complete suitable for 150 mm to 200 mm sluice valves complete all as specified and directed
Supply and Fix MS Nuts, Bolts,Washers and clamps suitable for CI, GI and DI Pipes suitable for 40 mm dia to 200 mm dia Flanged joints as per site requirement all as specified and as directed by Engr-in-Charge.
M&L for fabricaion and fixing, bracings, supports, clamps and back plates fabricated from structural steel sections i.e M.S. channel or angle sections etc. including new nuts, bolts, washers as reqd dia/length in size, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive one primer coat of red oxide, one under coat and one finishing coat of black paint (1st quality ) as reqd complete including Taking down old unsv MS Angle iron complete all as specified and directed.
M&L for replacement of MS sheet covers of valve pit, as per existing thickness , duly painted with one coat of red oxide primer and two coats of synthetic enamel black paint incl fixing arragement with existing angle iron frame (hinges, welding, nut and bolts ) complete all as directed by Engr-in-Charge
M & L for repair of existing damaged brick walls of valve pits of size (900x900x600 mm) incl plastering for smooth finishing complete all as directed by Engr-In Charge
Development of tube well by means of pumping by air compressor of minimum pressure 10Kg/cm2 (compressor to be arranged by the contractor at his own cost) until sand free clean water is obtained at optimum yield complete all as specified and directed. Note :- Development of bore well (150 feet to 300 feet long),
S&F in repair G.I union for 20/25/32 mm dia pipe, complete all as specified and directed.
S&F in repair G.I union for 40/50 mm dia pipe, complete all as specified and directed.
S&F G.I in repair union for 80 mm (3 inch) dia pipe, complete all as specified and directed.
S&F in repair G.I Nipple with length of 06 inch for 20 mm dia pipe, complete all as specified and directed.
S&F in repair G.I Nipple with length of 06 inch for 25 mm dia pipe, complete all as specified and directed.
S&F in repair G.I Nipple with length of 06 inch for 32 mm dia pipe, complete all as specified and directed.
S&F in repair G.I Nipple with length of 06 inch for 40 mm dia pipe, complete all as specified and directed.
S&F in repair G.I Nipple with length of 06 inch for 50 mm dia pipe, complete all as specified and directed.
S&F in repair G.I Nipple with length of 06 inch for 80 mm dia pipe, complete all as specified and directed.
Material and labour HDPE flexible hose pipe of size 50mm dia with all fittings fixed complete to laid in floors/bore well as per site requirement including taking out/dismantling complete all as required and directed.
Material and labour Nylon rope of size dia 20 mm three strand twisted burried in submersible pump set fixed complete all as required and directed.
Taking out of hand pump from bore well for repair and replacement of damaged parts complete refitting /fixing and lowering & testing complete all specified and directed. Note :- Defective spares parts shall be measured and paid separetely under relavent items.
Supply and fix pump cylinder assembly.
Supply and fix GI socket heavy duty, long type 32 mm dia.
Supply and fix hand pump water tank assembly rubber gasket.
Supply and fix hand pump head & handle assembly.
Supply and fix connecting rod MS 12 mm thick 3 mtrs long suitable for hand pump.
Schedule of credit (calculation will be done off line) Rs. 148259.00
TANUJ CONST. CO.
Dashmesh Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .