| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC SHOP NO G 5 NATRAJ PALACE NEAR GAJANAN MAHARAJ MANDIR KALYAN AMBERNATH ROAD SHANTINAGAR ULHASNAGAR 3 ULHASNAGAR MAHARASHTRA 421003 | THANE | MAHARASHTRA | 421003 | L1 | Accepted-AOC Techno commercially acceptable L1 bidder | |
| 2 | L2₹5.3 L+₹2.9 L (119.7%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
Refer Docs
Closing Date
9 May 2022, 11:00 amClosed
Chief Manager ( E )
Room No 105, 1st Floor, ADM Building, Chembur, Mumbai - 74
Miscellaneous Electrical jobs like operation of CMRI, testing of transformer oil, top up of transformer oil etc as per mentioned scope of work
2022_RCFL_683432_2
Township (E) /Misc Ele job/22-April
Open Tender
Electrical Works
Works
365 days
CHEMBUR
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
30 Jul 2022
29 Apr 2022
9 May 2022
29 Apr 2022
9 May 2022
29 Apr 2022
29 Apr 2022 - 9 May 2022
Dissolved Gas Analysis in Transformer Oil-DGA. Methane | Ethylene | Ethane | Acetylene | Propane | Propylene | Carbon Monoxide | Carbon Dioxide | Hydrogen | Oxygen | Nitrogen | Total Dissolved Combustible Gas Content | Total Gas Content % v/v - Job shall be executed as and when required as per instruction of site -in-charge. Testing shall be done approved labs as per applicable IS / IEC standerds. Detailed report shall be submitted with each testing.
Furan Analysis For Breakdown of Paper Insulation. 5-hydroxymethyl-2-furaldehyde (5H2F) | 2-furfurol (2FOL) | 2-furaldehyde (2FAL) | 2-Acetylfuran (2ACF) | 5-methyl-2-furaldehyde (5M2F) -Job shall be executed as and when required as per instruction of site -in-charge. Testing shall be done approved labs as per applicable IS / IEC standerds. Detailed report shall be submitted with each testing.
Mobilization & Sample Collection. Travel, lodging & boarding and local conveyance of Sampling team | Preparation & transportation of Sampling containers | Transportation of sampling hardware & tool | Sample drawn from identified sampling points by experienced persons as per applicable standerds.
BDV (Breakdown voltage) test of transformer oil. Testing shall be executed as and when required as per instruction of site -in-charge. Testing shall be done approved labs as per applicable IS / IEC standerds. Detailed report shall be submitted with each testing.
Transformer Oil top up. Supply of two experienced technicians with hand oil pump and other tools like suitable hose pipe, spanners, wrenches etc for a shift of 8 Hrs. Deputed persons shall have PF & ESIC registration. Deputed persons shall able to handle entir job by themselfs with out any asistence or guidence from RCF side. All required tools and tackles shall be arranged by the contractor.
Deployement of technician having sufficient knowledge and experience in operation of SANDS - L & T CMRI 1010 reader with RF communication. Deputed person shall have sufficient proficiency in MS -EXCEL, MS - WORd and SAP system. Job shall include downloading DATA from L & T make EM 101+ energy meter installed in individual quarters having RF port using CMRI ans BCS. Deployement shall be done as and when required.
Transportation arrangement (both truck and man power with required tools and tackles to load or unload the Oil drum shall be supplied) of departmentally supplied transformer oil drum (200 liter) with in RCF chembur township. (Electrical store to substation /Substation to substation / Office to substation).
Deployment of electrician with valid licence as and when required. Deployed electrician shall have ESIC and PF registration, sufficient experience in preventive maintenance of LT / HT systems. Deployment shall be done with all required tools and measuring instruments like Meggar,testers, multi meter, Earthing tester, testing lamps, LT hand gloves and insulation tapes etc.. Deployed electrician shall able to handle jobs like preventive maintenance of HT and LT electric system,
Supply of MECO 3600+ Clamp Meter, 1200A AC/DC True Rms. Detailed specifications- Jaw Size: 55mm AC Current: 1000A DC Current: 1200A AC Voltage: 750V DC Voltage: 1000V Resistance: 400- 40M Capacitance: 4nF, 40nF, 400nF, 4uF, 40uF Freqeuncy: 9.999,.99.99,999.9Hz, 9.9999Mhz Duty Cycle: 10-90% Temperature: 20-750 Degree Celcius
MOONLITE ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .