Supply of SMD 1800W +/-10% tolerance LED Floodlight fixture with System efficacy of 107 lm/W (200000 lumens
+/-10% variation). Luminaire shall be made up of multiple power coated cold forged unibody Aluminium housing
with PC lens. Luminaire should be made of single modules. LM 80-08 compliant LEDs from reputed makes such as
Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided and it should have base of maximum wattage
5W. LED must be of ceramic base type. Luminaire shall be with IP66 and IK10 protection. Luminaire must be
available with beam angle of 10/15/20Deg. The LED shall be compliant with LM80-08 standard with L70 life of
50,000 Hrs tested at maximum current +/-10% tolerance. The LEDs used should be with CCT of 5700 K and CRI of
1 Minimum 90, TLCI≥90. Single Driver will be potted type, Integral / Non Integral type Constant Current operated nos 184 165500 30452000
driver with range 180-528V AC. Driver Efficiency > 93% & 10KV internal surge protection with additional 10KV
SPD, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to
the luminaire. Operating temperature range: 0deg C to +45deg C +/-10% tolerance. Driver shall provide ultra low
ripple current of < 3%, NABL report must be submitted for ripple of the driver.. Compliance to Indian Standards of
Fixture weight should not be more than 19Kg +/-10% tolerance and dimension: 451 X 518mm (without bracket)
+/-10% tolerance. Wind Load test of the same housing must be available from third party lab.
Supply of 41M (Top of headframe) fixed head frame stadium High Mast complete with all accessories, designed
for mounting up to 48 nos. X 1.8kW LED floodlights and the wind loading as per IS 875 (Part III) for Delhi, with
recommended safety factors.
Supply of Foundation bolt sets for above High Masts complete with anchor plates and template.
Unloading, Shifting, stress fitting, mounting of head frame and other accessories and installation thereof on
existing foundations with suitable capacity main and auxiliary crane, adhering to all safety protocols. Proper
alignment, orientation and levelling of High Mast is an integral part of this activity. Note: The structural stability
design of the High Mast shall be approved/vetted by IIT/ NIT or any government institute.
High Masts Foundations - Removal of existing & construction of new
Design and construction of open raft type foundation for High Masts with 'M25' grade concrete and High grade
steel reinforcement. The foundation shall be designed as per the safe soil bearing capacity at the location,
3 considering the bending moments and other forces expected to be transferred on to the foundation. Fixing of job 4 55600 222400
foundation bolt assembly and provision of HDPE pipes for copper flexible cables is an integral part of this work
and includes all material, labour and T&P, shuttering and curing, etc. This item includes back-filling, compacting of
soil, removal of surplus earth and restoration, as applicable
Main-rider Unit for High Masts
Supply, Installation, Testing & Commissioning of External, removable man rider unit, common for all the four High
Masts. The man rider unit shall be supplied complete with lifting cradle with all standard attachments and
devices, set of stainless steel wire ropes and accessories, climbing motor with protection and its controls, other
accessories to complete the system in all respects. The man rider unit shall be deigned to carry a safe working
load of not less than 300kg and its climbing speed ideally shall not exceed 9m/minute at full load. The system
shall incorporate all essential safety features to prevent any accident even if any of the wire rope breaks and shall
ensure complete safety to the operator.
Aviation obstruction Light
SITC of Low intensity LED type aviation obstruction luminaries on high masts.
5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with Set 5 8,351.00 41,755.00
cover plate having locking
arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure Set 5 15,004.00 75,020.00
with cover plate having locking
arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
M.R. Providing and fixing 50 mm X 6 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with Meter 120 5,750.00 6,90,000.00
brass nut, bolt, spring, washer
excavation and re-filling etc. as required.
M.R. Providing and fixing 50 mm X 12 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. Meter 120 2,000.00 2,40,000.00
nut, bolt, spring, washer
excavation and re-filling etc. as required.
M.R. Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. Meter 200 2,649.00 5,29,800.00
M.R. Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Meter 200 627.00 1,25,400.00
Supplying, erecting, testing and commissioning outdoor duty floor mounted weather proof IP54 feeder pillar fabricated as detailed in description
given in E.1 above but with double door (lockable outer door), sloping roof, water run-off gutter on three sides as per approved drawing, entire
unit mounted on 50mm x 50mm x 5mm angle iron with minimum 300mm long "legs":
1nos 250 TPN MCCB.
1 no 96mm x 96mm multi parameter digital meter with LCD display for voltage & current with suitably rated CTs and MCB protection.
1 set of three phase indicating lamps with suitable protection.
Busbar: Equally sized three phase and neutral Aluminium conductors busbar suitably sized to carry 320A current and suitably insulated with colour
coded Heat Shrink Sleeve.
4 nos. 40A TP MCB
60 nos.10A/16A/32A SP MCB
2 nos. 16A water proof outlet.
(NOTE: Interlocking of the incoming breakers and coupler to be coordinated with PLC in DG Control Panel with suitable control wiring and auxillary
contacts left accordingly.)
INCOMER (Transformer)
1 nos 800A FP electrically operated draw-out type ACB with microprocessor-based relay for O/L, S/C and E/F protection with time delay facility
and fault type indication, with Reverse Power Relay and three phase indicating lamps, 1no 96mm x 96mm multi parameter digital meter with LCD
display for Voltage, Current, Frequency, Power, Energy, Power factor, RS 485 port for connection to BMS system and set of suitably sized CTs
including protection with 2A HRC fuses and suitable number of auxilary contacts for electrical interlocking as described.
INCOMERS (DG SET)
1 nos 800A FP electrically operated draw-out type ACB with microprocessor-based relay for O/L, S/C and E/F protection with time delay facility
and fault type indication, with Reverse Power Relay and three phase indicating lamps, 1no 96mm x 96mm multi parameter digital meter with LCD
display for Voltage, Current, Frequency, Power, Energy, Power factor, RS 485 port for connection to BMS system and set of suitably sized CTs
including protection with 2A HRC fuses and suitable number of auxilary contacts for electrical interlocking as described.
5 nos 250 A TPN MCCB with thermal-magnetic release setting of 80%-100%, rotary operating handle and ON indication with 1no 96mm X 96mm
digital 3-phase current Ammeter with suitably rated CTs and protected with set of 2A SP HRC fuses.
1no 800A FP electrically operated draw-out type ACB with ON/ OFF indication and suitable number of auxilary contacts for electrical interlocking
as described above
Equally sized three phase and neutral aluminium conductors busbar suitably sized to carry 1000A current and suitably insulated with colour coded
Heat Shrink Sleeve.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /
XLPE aluminium conductor cable of 1.1 KV grade as required.
MR Supply of following XPLE armourned 1.1 KV grade conforming to I.S.7098/1554Aluminium Conductor Cables :
Supply of following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor armoured cable of 1.1 KV grade conforming to IS:7098 part-1
/ IS:1554 part-1 respectively & ISI marked.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation,
sand cushioning, protective covering and refilling the trench etc as required.
10.2 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same
trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required.
MR Supply, Installation, testing and Commissioning of unarmoured Copper Control cable, PVC insultated, FRLS/HFFR
(a) 5Cx2.5 sq mm (from Sports flood light driver located at control room/panel to flood light on top of stadium mast) Meter 7488 286.00 21,41,568.00
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT.pdf
Tender Document
BoQ.pdf
Tender Document
SCC.pdf
Tender Document
GCC amendment 15.pdf
Tender Document
Instruction to Bidder for online Bid Submission.pdf
Tender Document
Forms.pdf
Tender Document
Tender Drawing .pdf
Tender Document
List of make.pdf
Tender Document
TECHNICAL Circular upto 27 amendment latest.pdf
Tender Document
corrigendum-4525-corrigendum-III.pdf
pdf • 0.57 MB
corrigendum-4448-Corrigendum-I.pdf
pdf • 0.20 MB
corrigendum-4435-Corrigendum-I.pdf
pdf • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .