Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 CrAccepted-AOC 309 10 SURESHWAR TECHNO IT PARK PREMISES CO OP SOC LTD NEW LINK ROAD BORIVALI WEST MUMBAI 400092 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400092 | ₹35.3 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹36.5 CrRejected-Finance THIRD FLOOR AMIT CRYSTAL SENAPATI BAPAT ROAD PUNE 411 016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹36.5 Cr | L2 | Rejected-Finance Not L1 Hence Reject. |
| 3 | L3₹37.2 CrRejected-Finance NIKHIL GROUP BEHIND ICC TOWERS NEAR JW MARIOTT SHRI SHIVAJI CHS P NO 65 SENAPATI BAPAT ROAD PUNE MAHARASHTRA 411016 PUNE MAHARASHTRA INDIA 411016 | PUNE | MAHARASHTRA | 411016 | ₹37.2 Cr | L3 | Rejected-Finance Not L1 Hence Reject. |
| 4 | Not Admitted-Fee/PreQual/Technical OFFICE NO 515 PLOT NO 194 NMS ICON SECTOR 19 ULWE NAVI MUMBAI MAHARASHTRA 410206 | NAVI MUMBAI | THANE | MAHARASHTRA | 410206 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹31.4 Cr
EMD Value
₹15.7 L
Closing Date
11 Jul 2022, 6:55 pmClosed
Executive Engineer, Public Works Division, Pune 1.
Executive Engineer, Public Works Division, Pune, Central Building Premises, Pune Station, Pune 411001.
9-1 - Construction of Nondani Bhavan Building for Inspector General Register (I.G.R.) of Maharashtra State, at Bundgarden, S. No. 10A, Munjeri 38, Pune -1 (Including Electrical Work).
2022_PWDRP_811434_1
E-Tender Notice No. 9 for 2022-2023 (Short Period)
Open Tender
Civil Works - Buildings
550 days
Council Hall Chawk, Bund Garden, Pune 1
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,360
₹15.7 L
Chief Engineer, Public Works Region, Pune 1
29 Nov 2022
24 Jun 2022
12 Jul 2022
24 Jun 2022
11 Jul 2022
24 Jun 2022
1 Jul 2022
Amount
Removing grass,grazer grass and disposing off out of building premises including making clean the ground by shovel and phavaras etc.complete.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming , watering including shoring and strutting etc. complete. (Lift upto 1.5 metre) By Mechanical Means
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming , watering including shoring and strutting etc. complete. (Lift upto 1.50 metre) By Mechanical Mean
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/ murum, ramming , watering including shoring and strutting etc. complete (lift upto 1.5 metre) By Mechanical Means
Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming , watering including shoring and strutting etc. complete. (Lift from 1.5 metre to 3.0 metre) By Mechanical Means
Excavation for foundation in Softrock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary backfilling with available earth/ murum, ramming , watering including shoring and strutting etc.complete. (Lift from1.5 metre To 3.0 metre) By Mechanical Means
Excavation for foundation in Softrock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary backfilling with available earth/ murum, ramming , watering including shoring and strutting etc.complete. (Lift from 3.0 metre To 4.5 metre) By Mechanical Means
Excavation for foundation in Softrock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary backfilling with available earth/ murum, ramming , watering including shoring and strutting etc.complete. (Lift from 4.5 metre To 6.0 metre) By Mechanical Means
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including tri millimetre ing and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift from 4.5 metre to 6.0 metre). By Mechanical Means
Dewatering on BHP basis by using water pump including diversion of stream, providing cofferdams, earthern bunds etc. as may be necessary for foundation and other parts of the the works and pumping out water during and after excavation as may be required by using 3.0 BHP pump etc. complete. (prior approval of Superintending Engineer will be necessary)
Providing and laying perforated Poly vinyl chloride 160 millimetre diameter pipe in proper line,leveland slope including necessary material fitting etc. complete.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-10 of trap metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade)
Providing and fixing 20 to 25 millimetre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick cement mortar 1:3 with conceal, setcrete ( RMW ), Algaeproof or other alike water proofing liquids, raking of joints upto 35 millimetre depth,filling the joints with 6 millimetre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding cement concrete 1:3:6 base concrete).
Providing and fixing 20 to 25 millimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 millimetre between rough shahabad and Reinforced Cement concrete walls with cement grout mixed with water proofing liquid Algaeproof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 millimetre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrtete 1:3:6 base concrete).
Providing and laying jointless Polydee-LM, a highly flexible elastometric coating for Reinforced cement concrete / cementitious surface for terrace waterproofing on burnt brick Coba / Reinforced cement concrete , after application of TP-42 Primer on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee-LM @ 700 gms/Square Metre
Providing and laying Cast in situ/Ready Mix cement concrete Mix 25 of trap metal for Reinforced cement concrete . work in foundations like raft, strip foundations, grillage and footings of Reinforced cement concrete . columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade)
Providing and laying Cast in situ/Ready Mix cement concrete Mix-30 of trap metal for Reinforced cement concrete. work in foundations like raft, strip foundations, grillage and footings of Reinforced cement concrete . columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) BASEMENT 1
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap metal for Reinforced cement concrete PARDI as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) BASEMENT 1
Providing dry rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting complete. GROUND FLOOR
Filling in plinth and floors with approved excavated materials in 15 centimetre . to 20 centimetre . layers etc.complete. BASEMENT 2
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/ bolted/ welded connections without connecting plates, braces etc.and including one coat of anticorrosive paint and overit two coats of oil painting of approved quality and shade etc.complete LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete Mix-40 of trap metal for Reinforced cement concrete . columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete Mix-25 of trap metal for Reinforced cement concrete . columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-25 of trap metal for Reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete Mix-40 of trap metal for Reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete Mix-25 of trap metal for Reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) LOWER GROUND FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete Mix-40 of trap metal for Reinforced cement concrete . slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Cast in situ/Ready Mixcement concrete Mix-25 of trap metal for Reinforced cement concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-20 of trap metal for Reinforced cement concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in Mix-25 of trap metal for Reinforced cement concrete . Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controller (PLC) with Supervisory Control And Data Acquisition (SCADA) Concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical shaft impact (VSI) Grade) BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing in position Thermo Mechanically Treated (TMT) - FE - 500 bar reinforcement of various diameter meters for Reinforced cement concrete . pilecaps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawing sand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing in position to the exact profile and prestressing the high tensile strands to specified ultimate strength, standard end anchorages, cable ducts, grouting ducts after prestressing and bearing plates with wedges as per detailed drawings including necessary plant and machinery for prestressing etc. complete. LOWER GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing during laying in Reinforced cement concrete Slab rectangular 2 millimetre thick mild steel sheet fan hook box of size 180x100 millimetre with required depth with holes or not chesas required, bottom and top sides of 1.6 millimetre mild steel sheet fixed with 3.5 millimetre diameter . round headed screws together with 12 millimetre diameter mild steel bar bent to shape with hooked ends for fan hook and painting to exposed surface. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
Providing cement based water proofing treatment to terraces (In diameter n water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortr 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar .1:3 admixed with approved water proofing compound and finally top finishing with average 20 millimetre . thick layers of same mortar added with jute fiber at 1 kilogramme per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetre x 300 millimetre . making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. EIGHTH FLOOR
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part3)-1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185(Part3)-1984 in extra fine jointing mortar offixoblock of UltraTech or equivalent in Halfbrick thick wall including striking joints, raking out joint sand scaffolding etc. Complete. (The test shall becarried out conforming to IS:6441 (Part I) - 1972) BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
75 millimetre thick Gypserra™ stud or equivalent partition which includes single layer of tapered edge 12.5 millimetre thick Gypboard or equivalent Plain (conforming to IS 2095 Part 1:2011, Certified board) of size 1219x2438 millimetre is screw fixed to C-stud. 48x0.5 millimetre Gypserra or equivalent C-stud {Material-IS 513, Y/S-300Mpa, Finish - AZ150 (IS 15961)} placed at 610 millimetre c/c in 50x0.5 millimetre Gypserra or equivalent {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961)} floor and ceiling channel. Floor and Ceiling channel is anchored to the floor and True ceiling using Gyproc or equivalent Rawl plug Ø8x45 millimetre {Material-IS 513 CR1 grade, Zinc coating, Pull Out Load-6.8kN for M30 concrete grade} /Hilti X-GN20MX anchor fasteners at 600 millimetre c/c in center line. Floor channel to be wrapped with 70µ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. A Gypserra or equivalent noggin channel {Material-IS 513,Y/S-300 Mpa, Finish - AZ150 (IS 15961)} of 48x0.5 millimetre width has to be provided at the horizontal joints of the two boards. Gyproc or equivalent boards to be screw fixed with Gyproc or equivalent drywall screws of 25 millimetre at minimum spacing of 300 millimetre at centre and 150 millimetre at periphery. 25 millimetre Glass wool slab of density 20kg/m³ shall be placed in metal framework. Glass wool holding clip should be used to hold Glass wool slab in its position. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Gyproc or equivalent Pro-Fill Jointing compound (Conforms to ASTM C475), Gyproc® Joint Paper tape or fiber tape. The junction of the partition with masonry and all penetration through the partition has to be treated with Hilti/Pyroplex acoustic sealant. All other detailing and specifications to be followed as per approved drawing of Gyproc or equivalent. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on the site. Work shall be carried our including all lead and lifts etc as directed by Engineer-In-Charge. SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre . width at the junction of Reinforced cement concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / burnt brick masonry and or tying by binding wire etc. complete. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing internal cement plaster 20 millimetre thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing fine cement finish 1.5 millimetre thick over green plaster surface including scaffolding curing etc. complete. BASEMENT1
Providing and applying gypsum plaster (with Gypsum material of Gypsum In diameter / Mega Sign or equivalent make) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface/ or on newly brick surface (Excluding rough cast plaster) in all position including preparing and finishing the surface scaffolding etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying plaster with plaster of paris in 6 millimetre thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1 kilogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing internal / external 20 millimetre thick Ready Mix plaster confirming to IS:4031(Part-4) 1988 and IS 383- 1970 in a single coat using Cement mortar of proportion 1:4 containing special type of polymer additives about 0.4%, to all type of surfaces in all positions including scaffolding and curing complete LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing water proof bedding for flooring of Bath and Water closet 25 millimetre thick in cement moratr 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. LOWER GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing waterproofing in Water closet and bath including brick bat coba in all position including providing and laying 12 millimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1 kilogramme /per bag of cement laying brick bat coba of required thickness in centimetre 1:5 with waterproofing compound 1 kilogramme /bag of cement grouting and finishing the top layer with 20 millimetre thick brick bedding in centimetre mortor 1:3 with waterproofing compound 1 kilogramme /per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 Square Metre / kilogramme with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in cement mortar 1:3 curing and cleaning etc. complete. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying machine cut machine Polished Kota stone flooring 25 millimetre to 30 millimetre thick and required width in plain/ diameter mond pattern on bed of 1:6 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 millimetre to 30 millimetre thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and Fixing in position, Carpet more than 800+ gsm, made with100% stain proof fibres of approved make along with 5 millimetre underlay as per Architectural and Acoustical Design and Instructions and Complete in all aspects including all materials labour,finishing etc complete. SEVENTH FLOOR
Providing and laying matt finish ceramic tiles of having size 30 centimetre x 30 centimetre confirming to Indian Standard 15622/2006 (group D II-A) and 7 to 8 millimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/ dado/ window boxing etc. On cement mortar 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying in situ cement concrete M20 with tremix treatment for 100 millimetre thickness for flooring with groove cutting of 4 millimetre wide and 20 millimetre deep with necessary refilling with bitumen etc. complete. LOWER GROUND FLOOR
Providing and fixing machine cut mirror polished 18 millimetre to 20 millimetre thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and preparing kitchen otta up to 75 centimetre width, made up from 30 millimetre . thick and 75 centimetre . high vertical support for kadppa at 1 metre center to center of 25 millimetre . thick both side polished kadappa middle shelf and bottom of 20 millimetre . thick one side polished kadappa with facia patti of 20 x 50 millimetre . kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Polishing applying malamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying french polish, scaffolding if required etc. complete. Note: The work to be excuted on prior approval of Superintending Engineer will be necessary. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying one coat of flat oil paint of approved colour to the old structural steel work and iron work previously painted in building including scaffolding, if necessary, cleaning and preparing surface (excluding primer coat) etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying priming coat over concrete/ Masonry/ Asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, greese, dirt and other foreign matter and sand papering as required etc. complete. humidity of upto 90%. Magnesite protects the wood cells against ageing and fungal attack. To achive upto NRC=1.00 it should be a clear gap of 200 millimetre from wall slab along with the backing of Mineral wool of 50 millimetre thick with 64 kg/m3 density. Ecologically Sound Material with high mechanical strength with Crash test of 90Km/H with Ball Impact Test DIN18032 and EN13964 with flying colors and A sustainable material (PEFC and FSC Certified) along with EPD Certified Acc. to EN ISO 14025 (AUB-Envirenmental Product declaration). Manufacturing tolerance for nominal size: Length, Width and Thickness ± 1 millimetre , and In a Standard Climate of 23° C and 50% rel. humidity. FIXING and SUBSTRUCTURE: Impact Resitant According to DIN-18023 or EN13964 to be Fixed on CD Sections Profile framework with Screw 9Pc/Panel and Centre Distance Support of 300 millimetre and Centre distance of Cross Profile would be at 600 millimetre and Main Profile at 900 millimetre CD Profile is made out of GI( Sections Profile 60/27/0.6 millimetre -0.6 millimetre Thick x 60 millimetre Width x 0.27 millimetre height). The Main Profile is in the legth of 3000 millimetre and to form a section of 600 millimetre x 1200 millimetre . Heradesign Superfine panels to be fixed on the wall with a minimum of 200 millimetre void or gap with Galvanized screws of length 50 millimetre and diameter 4.5 millimetre with a backing of Mineral Wool of density 64kg/m3 density (50 millimetre thick).Colour Of Panels : NATURAL BEIGE, Can be Painted to the desired colour (Any- RAL, NCS or StoColor Shades) using water based color by Spray method prior to installation. FIRE CLASS as per EN 13501-1:B –s1, d0. Test Certificates to be submitted. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying one coat of seal cement primer of approved manufacture and shed including scaffolding preparing the surface by cleaning dirt and other foreign matters, scraping if necessary including scaffolding etc. complete. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying Asian / Berger / Nerolac / Dulex Paints or equivalent acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45 % or 65 to 70 % by roller. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC?s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kilogramme /15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Reco millimetre ended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying top coat exterior paint to terrace of approved make, shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by throughly cleaning of oil, grease, dirt and other material and fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) preparing as required, etc. complete. FIRST FLOOR
EIGHTH FLOOR
Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600 millimetre Lay in tiles of pre coated galvanized steel in 0.5 millimetre thickness in Global white color tile to be laid on grid systems with 15 millimetre wide T - section flanges color white having rotary stitching on the Main Runner, 1200 millimetre and 600 millimetre Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600 millimetre Lay in tiles of pre coated galvanized steel in 0.5 millimetre thickness in Global white color tile to be laid on grid systems with 15 millimetre wide T - section flanges color white having rotary stitching on the Main Runner, 1200 millimetre and 600 millimetre Cross Tees.products approved as per GRIHA and BS 476 etc. complete. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
METAL FALSE CEILING WITHOUT SUSPENSION SUPPORT FROM TRUE CEILING: Providing and fixing horizontal level suspended metal ceilings comprising of Metalworks F-H 600 Hook-on corridor system manufactured by Armstrong Ceiling Solutions with Rectangular panels made of 0.7 millimetre thick Galvanised Steel (GI) of 120gsm, post coated to Global White colour, suitable for Interior applications and architectural finishes, double grid concealed system and butt joint panels. The panel width shall be 300 millimetre , length ranging from 1500 millimetre to 2660 millimetre . General Specifications:Entire system to be designed for Interior applications, and concealed Grid, Butt joint panels. Panel Specifications: Material: The F-H 600 rectangular Hook-on panels to be made of galvanized steel (GI) of minimum 120gsm hot dipped galvanization (both sides included) as per IS 277 (2003), zero or minimum spangled, in minimum base material thickness of 0.7 millimetre as per in IS:513 (1994). Dimensions: The panel Length varies between 1500 millimetre to 2660 millimetre , panel Width shall be 300 millimetre . The dimensional tolerances for length shall be ±1.0m up to 1000 millimetre L; ±1.5 millimetre between 1001 to 2000 millimetre L; ±2.0 millimetre between 2001 to 3000 millimetre L. The dimensional tolerances for width shall be ±0.5m up to 300 millimetre W. Dimensional Tolerances for panel Thickness / panel width / panel length - to be measured in accordance with TAIM standards. Edge detail: the panels shall ha+A3ve Square Edge, with a 3 millimetre (W) x 8 millimetre (H) black foam gasket glued at the edges, typically on one long and one short side. All adjacent panels shall touch each other forming a butt joint and concealed grid visuals. Upturns: The short side of the panel shall have vertical upturns of minimum 30 millimetre (H) and shall be bent appropriately bent as per the manufacturer‘s specifications for providing hook-on ends. The long side shall have inside horizontal bends of 5-15 millimetre for rigidity and vertical upturns of 40 millimetre (for length ranging from 1251-2660 millimetre ). Surface Finish: Plain: The panels shall be in plain unperforated finish (without any acoustical backing / felt). Colour and finishes: The panel surface shall be electrostatically powder coated (post coat) on visible side after mechanical production, using RoHS compliant powder, to achieve coating thickness ranging from 60-80µ and architectural quality finish. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017, 250 hours of condensation test (as per DIN 50017 or DIN EN ISO 6270-1 Norms), UV resistance of 500 hours and 50% gloss retention (as per ASTM G 154 UVB-313 Norms). The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E (∆e) <1 measured using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523.The colour / shade to be Global White (Polyester for Interior) as approved by the Architect or Engineer-in-charge. Surface Protection: The visible panel surface shall be protected using a guard film made of LDPE of 50µ thickness, having appropriate surface adhesion (or tackiness) corresponding to surface gloss level. Light reflectance: The panel shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98. Flatness and Sag limit: Panels shall be flattened by precision leveller to minimize sag to less than Length/400 millimetre . The difference between the two diameter gonal dimensions of the panel to be less than 1 millimetre . The sag to be measured at the center in accordance with TAIM standards. Access and Plenum space: The panels to be Fully Accessible, with system height of 98 millimetre , and would require a plenum height of a minimum 450 millimetre clear space from bare ceiling / rigid structure for installation. Packaging: The Panels shall be packed in wooden crates of appropriate dimensions based on panel sizes. The wooden planks for rates shall have thickness of approx.15 millimetre , width of around 4‖ and gap between two planks around 3‖. Crates to have layer separators of 1‖ x 2‖ dimensions to prohibit load transfer on bottom panels, and the crates lifting to be 2way or 4way. The bottom of crates shall be completely closed, and the panels kept inside shall have cushioning of corrugated sheets or other appropriate material. Installation Specifications: Primary and secondary runners Installation: U-Profiles, spaced at 1200 millimetre , to be suspended from ceiling using clamping brackets and threaded rods OR hanger wires. Hanger wires must be wrapped tightly with 3 full wraps. The J- Bars (directional) shall intersect the U-profile at 90° at every module dictated by the panel length. The J-Bar is connected to the U- BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15 millimetre Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 and 7) in module size of 600 x 600 x 20 millimetre , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 millimetre with 15 millimetre wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 millimetre and 600 millimetre Cross Tees with a web height of 32 millimetre and a load carrying capacity of 7.7 kilogramme s/M2 and minimum pull out strength of 100 kilogramme s.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing in position Gypsum board false ceiling with 12.5 millimetre thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimetre maximum center to center distance of 600 milimetre perimeter channel and interme diameter te channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and interme diameter te channels. Additional interme diameter te channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
ACOUSTICAL WOODWOOL WALL PANELLING: Providing and fixing of 100% Natural Material- Magnesite (Hygroscopic and biologically sound binding agent) bonded woodwool Heradesign planks of 600 millimetre *1200 millimetre *25 millimetre thickness made out of wood wool fibre of width 1 millimetre Fiber thickness mixed with Natural water and Magnesite (No-Cement) with open and smooth surface texture, Weight of panel to be 11.3 Kg/m2. A Completly harmless Envirenment and Human Friendly and also a disposable or recyclable Material and can last for more than 80 Years in building interiors As it has long lifespan and suitable for Indoor conditions with relative air humidity of upto 90%. Magnesite protects the wood cells against ageing and fungal attack. To achive upto NRC=1.00 it should be a clear gap of 200 millimetre from wall slab along with the backing of Mineral wool of 50 millimetre thick with 64 kg/m3 density. Ecologically Sound Material with high mechanical strength with Crash test of 90Km/H with Ball Impact Test DIN18032 and EN13964 with flying colors and A sustainable material (PEFC and FSC Certified) along with EPD Certified Acc. to EN ISO 14025 (AUB-Envirenmental Product declaration). Manufacturing tolerance for nominal size: Length, Width and Thickness ± 1 millimetre , and In a Standard Climate of 23° C and 50% rel. humidity. FIXING and SUBSTRUCTURE: Impact Resitant According to DIN-18023 or EN13964 to be Fixed on CD Sections Profile framework with Screw 9Pc/Panel and Centre Distance Support of 300 millimetre and Centre distance of Cross Profile would be at 600 millimetre and Main Profile at 900 millimetre CD Profile is made out of GI( Sections Profile 60/27/0.6 millimetre -0.6 millimetre Thick x 60 millimetre Width x 0.27 millimetre height). The Main Profile is in the legth of 3000 millimetre and to form a section of 600 millimetre x 1200 millimetre . Heradesign Superfine panels to be fixed on the wall with a minimum of 200 millimetre void or gap with Galvanized screws of length 50 millimetre and diameter 4.5 millimetre with a backing of Mineral Wool of density 64kg/m3 density (50 millimetre thick).Colour Of Panels : NATURAL BEIGE, Can be Painted to the desired colour (Any- RAL, NCS or StoColor Shades) using water based color by Spray method prior to installation. FIRE CLASS as per EN 13501-1:B –s1, d0. Test Certificates to be submitted. FIRST FLOOR
ACOUSTICAL GLASS FIBRE FALSE CEILING BLADES : Providing and Fixing Acoustical blade which are 40 millimetre thick, flat glass fibre panels with Humidity Resistance RH 90%, with factory fitted embedded metal insert with ¼‖ – 20 threading for fixing cable adjuster for hanging application. Acoustical blades shall have sizes of 200x1200 millimetre , 200x1600 millimetre , 400x1200 millimetre , 400x1600 millimetre , 400x1800 millimetre , 500x1200 millimetre or 500x1600 millimetre with both side laminated scrim finished with uniform water based paint on all surface (including edges). Acoustical performance of 0.65 NRC(for 400 millimetre high x 40 millimetre thick baffles with 400 millimetre on centre distance and overall depth of construction 1000 millimetre ) as per ASTM C-423 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) in standard White color with Light reflectance 87% or in the color specified by the Architect (Shell / Tangerine / Cranberry / Moss / Kiwi / Reef / Lagoon), Fire Performance Class B2 – s1, d0 as per EN 13501-1 .The blade shall be made of Glass fibre panel with density of 110-120 Kg/ m3. SUSPENSION: The panel shall be hung using hanging kit comprising of griper structure anchor and cap of diameter 20 millimetre , spring loaded bottom end cable adjuster of diameter . 9 millimetre and 2.4m long aircraft cable of 1/16‖ diameter . The Blade along with suspension system shall carry a 1 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The supply shall be backed by a Manufacturing Test Certificate. Suspension System Details Components 1) Griper structure anchor 2) Gripper anchor cap 3) Cable adjuster 4) Aircraft Cable Cable adjuster Spring loaded bottom end cable adjuster of diameter . 9 millimetre and 45 millimetre long Aircraft cable Material Galvanized Steel Aircraft cable dimension 1/16‖ Ø x 2.4m Tolerance ±1 millimetre . INSTALLATION: Hanger Wire Attachment to Structure: Attach the gripper structure anchor to the structure with an appropriate fastener (1/4"-20 Threading) that will carry the full weight of the blades. Insert the end of the cable into the gripper anchor cap. Screw the gripper anchor cap completely into the gripper structure anchor. Insert Suspension Cables: The panel is to be suspended using the aircraft cables which are suspended from the soffit using the gripper structure anchors and its other end passing through the bottom end cable adjuster. The height and level of the panels can be adjusted using the bottom end cable adjusters. Suspension of Blade: Locate the two factory fitted female inserts on the blades. Suspend the Blades by screwing the bottom end of the cable adjuster into the female inserts. Installation should be carried out as per Manufacturer reco millimetre ended procedure. LOWER GROUND FLOOR
Providing and fixing solid core flush door shutter in single leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing solid core flush door shutter in double leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetre x 40 millimetre x 5 millimetre with oil painting, etc. complete. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
a) Door Frame: Supplying and Fixing frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 kilogramme /cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 millimetre spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10 millimetre x 4 millimetre affixed in the slit of the Frame for fire and smoke sealing, etc. complete." LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
b)Shutter : Supplying and Fixing of 55 millimetre thick asbestos free 'TUFWUD' brand - 3 criteria checked - fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance - FD 120 as per IS:3614 (part - II) comprising of 2x8 millimetre Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in vaccum pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to 810 kilogramme /cum) frame work of 100x32 millimetre with 32 millimetre thick infill of ceramic fiber (density 128 kilogramme /cum), vermaculite mix faced with 3 millimetre Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10 millimetre x4 millimetre affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Two Track Two Glass Shutter Window : Providing and fixing aluminium color anodized system sliding window of various sizes. Window will be made from Geeta / Lixil / Malwin , 25 to 27 millimetre slim series or equivalent System. Windows will be of specially extruded aluminium 2 Track - 2 Glass shutter window/ ventilator, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 5 millimetre clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Three Track Four Glass + Two Net Shutter Window : Providing and fixing aluminium color anodized system partly sliding partly fixed window of various sizes. Window will be made from Geeta / Lixil / Malwin 25 to 27 millimetre slim series or equivalent System. Windows will be of specially extruded aluminium 3Track - 4 Glass + 2 net shutter, track joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 screws. Glass shutter will be made from specially extruded aluminium section, glass considered is 5 millimetre clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All shutter will be fixed to the main frame with necessary double roller to have smooth and easy movement of the shutter. Shutters will have single point self pressing lock. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. complete. SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etc. complete. LOWER GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Aluminium System Color Anodized Fixed Window : Providing and fixing aluminium system color anodized fixed window of various sizes. Casement will be made from Geeta / Malwin/Lexil/Brandson, 40 millimetre series or equivalent System. Windows will be of specially extruded aluminium section, joints will be of 45 degree joints, joints will be fixed with specially developed clits. Track frame will be fixed to the masonry opening of windows with S S 202 wood screws. Fixed glass casement will be made from specially extruded aluminum section, glass considered is 5 millimetre clear toughened glass. All shutter will be having 45 degree joints, joints will be fixed with specially developed clits to form uniform hairline joint. All fixing screws will be of S S 202. Windows will be sealed with weather sealant from outer periphery, etc. complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing single shutter glass door of required size of 12 millimetre thick toughen glass frosting and edge polish as shown in the drawings or as directed , including all necessary fittings like hydraulic patch fitting, top patch fittings, Top pivot, door handle, door lock, door stopper, door soft central 180 weather seal for door edges etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete. FIRST FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
Providing and Fixing Aluminium colour anodized sliding and folding door 2 shutters having special patented frame and shutter profiles.Oter frame profles being fixed to the missionary with SS-202 screw shutters having 45 degree corner joints with special cleats for linear joints having 6 millimetre toughned glass are installed in the frame structure with mortise lock at opening, Top and bottom pivots for sliding,but hinges for folding operation and subsidiary multi point locking and pop handle for additional security,complete. LOWER GROUND FLOOR
FIRST FLOOR
Providing and fixing double shutter glass door of required size of 12 millimetre thick toughen glass frosting and edge polish as shown in the drawings or as directed , including all necessary fittings like hydraulic patch fitting, top patch fittings, Top pivot, door handle, door lock, door stopper, door soft central 180 weather seal for door edges etc. all complete as per architectural drawings and the directions of the engineers-in-charge with all necessary fasteners and accessories complete SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing 12 millimetre thick toughen glass and edge polish as shown in the drawings or as directed, including all necessary fittings like Upper glazing profile, bottom locking glazing profile, standard gasket for profile, locking Gasket 12 millimetre , door soft central 180 weather seal for glass edges as per drawings having glass fixing sections at all sides concealed in partitions etc. complete as directed by Engineer -IN-Charge. gaps between glass panels should be filled by clear silicon weather proofing sealant , EPDM gaskets, handles all necessary fasteners and accessories complete.as directed by Engineer -in-Charge LOWER GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing frosting to the glass and other required surfcaes as shown in the drawings or as directed, including all necessary work etc. Frosting should be even and no uneven patterns will be accepted for the same. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on the site. Work shall be carried our including all lead and lifts etc as directed by Engineer-In-Charge. LOWER GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 millimetre minimum size, crossings of M.S. flats of size 18 x 5 millimetre T or E section for runner of minimum 40 x 6 millimetre size for flange, M.S. flat for top runner of minimum size 40 x 12 millimetre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 millimetre max. spacing of vertical channels be 100 millimetre enclosed gate position and clear space of 150 millimetre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. ( Indian Standard 105211983). LOWER GROUND FLOOR
Providing and fixing anodized aluminium 'C' channel square fillet made up of Jindal or equivalent section of size 203.20 X 65 X 11.84 at various level including labour, scaffolding and necessary fixing material, hardware's, required for this job. All fixing studs, rivets must match with the same shade anodizing of the aluminium channel Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on the site. Work shall be carried our including all lead and lifts etc as directed by Engineer-In-Charge. LOWER GROUND FLOOR- main entry gate
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing mechanical puzzle car parking suitable for standard passange cars of three stacks as per the sizes and specifications in given drawing including all the necessary mechanical equipment's, hardware's, software's, electrical assembly and panels entire system considering appropriate clearance space at top and bottom and sides. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on the site. Work shall be carried our including all lead and lifts etc as directed by Engineer-In-Charge. LOWER GROUND FLOOR
Providing and fixing 30 millimetre thick Poly vinyl chloride FLUSH L DOOR SHUTTER consisting of panel of hollow Poly vinyl chloride profile of 20 millimetre thickness consisting frame made out of M.S. tubes of 19 gauge thickness and size of 19 millimetre x 19 millimetre inserted inside the hollow section of stiles rails top ?and bottom rails and two 19x 19 millimetre MS tubes inserted horizontally inside the hollow profile section using 4/5 millimetre sheet using screws hollow profile shall be lipped with 10 millimetre (5 millimetre x2) thick x 20 millimetre width on stiles and rails using solvent cement. The inner panel shall be laminated with 5 millimetre thick termite proof waterproof plain /prelam Poly vinyl chloride sheet using solvent cement on the both sides of the panel including stainless steel fixtures and fastening etc. Complete as per direction of Engineer incharge, manufacturers specification and drawing. LOWER GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kilogramme per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 millimetre diameter . and vertical pipe of 38 millimetre diameter at 0.60 metre centre to centre or as required and horizontal pipes of 25 millimetre diameter in three rows, all pipes of 2 millimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter meter and ball base of 75 millimetre diameter above newel post of 75 millimetre diameter meter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing 40 millimetre diameter meter and 1.5 millimetre thick Stainless steel hand railing in S.S.304 Grade including fabricating ,fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete. BASEMENT1
LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 centimetre and one no SS 304 hinged rail 76 centimetre s and three no SS 304of (Grab Bar) 60 centimetre s all including cutting and making good the walls and floors wherever required ,seat cover, cistern and wash basin fittings,nuts, bolts and gasket etc complete as per the direction of Engineer-In-charge. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying vitrified matt fininsh tiles having size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying vitrified matt finish tiles having size 300 millimetre X 600 millimetre of 8 to 10 millimetre thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. BASEMENT1
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and applying texture plaster of STONETEX - TRAVERTINE SERIES - ST-2002 special luxurious stone finish coating (3 product type – 6 coat system) for exteriors and interiors. Texture midcoat incorporating natural stone granules like natural Sandstone, Granite, Limestone, Ceramic chips, natural sand etc. including grooves to be provide as per design and drawings. Apply two coats of under coat primer by roller or brush then apply masking tape to create grooves as per design and drawings. First coat of texture midcoat finish by spray gun, evenly over the entire surface. Apply second coat of texture midcoat finish by spray sprinkle method, evenly on the whole sea of the previously dried first coat. Apply two coats of top protective coat evenly on the surface including grooves with roller or brush. It should be water based and ecofriendly product including preparing the surface, scaffolding etc. complete as directed by Engineer in-charge. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing of Rubber Matting 8 millimetre thick of roll or approved design fixing with adhesive solution, including transportation,loading, and unloading, all necessary arrangement, tools,plants,machinery other fixtures and fasteners etc. complete as per details and directed by Engineer-in- Charge, including all taxes, transportation, loading and unloading etc complete as directed by Engineer-in- Charge (Rate is inclusive of all other taxes,Excluding GST) EIGHTH FLOOR
Providing and laying wooden based matt finished Vitrified tiles of approved colour having size 190 to 200 millimetre x 1200 millimetre and 8 to 10 millimetre thick for flooring. Required sample is needs to get approved from the project Architect before execution on site. Work shall be carried our including all lead and lifts etc as directed by Engineer-In-Charge. THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing Stainless Steel 304 Grade matt finish Stainless steel glass railing of 1000 millimetre height with 50 millimetre diameter meter and 1.5 millimetre thick hand rail at top, with Stainless steel 304 grade matt finish stainless steel bottom patch of rectangular shape spaced at 1.5 metre center to center and 12 millimetre thick toughened glass including fabricating , fixtures, errecting , necessary welding , grinding ,finishing, buffing to stainless steel pipe etc. complete. SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and laying matt finish ceramic tiles of having size 30 centimetre x 30 centimetre confirming to Indian Standard 15622/2006 (group D II-A) and 7 to 8 millimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing “BOIS” make or equivalent clay bricks as a cladding of average thickness 11 millimetre . Cladding Bricks of approved colour and size with similar corner pieces Bricks with pointing and flush type joint. Including scaffolding raking out joints and providing grooved pointing with cement mortar 1:3 using pigment of approved shade having width and shape as per directed by engineer Incharge. Adhesive chemical should be applied back side of cladding @ 4.3kg/sqm. Sample needs to be get approved from project Architect before execution of work. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing “BOIS” make or equivalent wire cut burnt brick masonry of average thickness100 millimetre in cement mortar 1:4 including scaffolding raking out joints and providing grooved pointing with cement mortar 1:3 using pigment of approved shade having width and shape as per directed by engineer Incharge. Adhesive chemical should be applied back side of wall @ 4.3kg/sqm as directed by Engineer -in-Charge. Sample needs to be get approved from project Architect before execution of work. GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 millimetre stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 kilogramme load bearing capacity of trolley made out of 20 millimetre PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 millimetre s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge) FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing CLADDING TYPE - 84R louvers of approved color consisting of panel 84 millimetre wide 16 millimetre deep x 0.6 millimetre thick with 30 millimetre gap with round edges panel length up to 6 Metre coil coated on continues paint Line double baked and roll formed from enameled corrosion resistance. Aluminium Alloy AA3005 (Al. Mg.) for higher strength and good roll forming characteristics Panel shall be clipped to baked enameled aluminium cladding type panel stringer of 33 millimetre wide and 86 millimetre deep X 0.95 millimetre thick in a standard Length of 5 Mt made of double baked enameled Aluminium alloy AA5050 (Al. Mg.) black with cut-outs to hold the panel in a module of 86 millimetre center to center at a distance of 1 Mt. The Carrier shall be fixed to suitable structure by means of rigid fixing details including Paint Finish : Aluminium panels shall be cromotised for maximum bond between metal and paint enameled twice under high temperature one side with full primer and luxacoat finish. The other side (Inner side) with a primer coat and skin coat on a continuous paint line etc.complete as directed by Engineer-in-charge. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on the site. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Aluminum Cladding: Providing and fixing Aluminum Jali Laser cut of 2 millimetre thickness with pure polyester Matt finish exterior grade UV resistant colour anodizing . The jali to be fixed to the sub framing (in our scope) using self drilling screws which shall not be visible in the elevation. The sub framing to be anchored to the main building using Anchor fasteners. Test report to be submitted for structural stability of the system for its self weight and wind load of 120kmph. Required detailed shop drawing and sample is needs to get approved from the project Architect before execution on site. Work shall be carried our including all lead and lifts. FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Structural Glazing : Providing and fixing structural glazing work of 5 millimetre tk tinted toughened glass with frame work made of aluminum RHS of size 64 millimetre x 58 millimetre color anodized as per design and drawing, aluminum sections should be confirming IS 63400 , glass pasted to frame work with approved spacer tape and DOW CORNING 995 silicon sealant and gaps between glass panels should be filled by clear Dow CORNING 789 silicon weather proofing sealant , with all necessary fasteners and accessories complete. LOWER GROUND FLOOR
GROUND FLOOR
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
FOURTH FLOOR
FIFTH FLOOR
SIXTH FLOOR
SEVENTH FLOOR
EIGHTH FLOOR
Providing and fixing Aluminium anodised logo of size 2.5m x 2.5m with building name including all fittings and fixing as per selction of project Architect. Logo image must be approved and verified by project Architect. etc complete as per direction of the Engineer-in-Charge LOWER GROUND FLOOR
Conveyance of material/debris at a distance of 10 Km as directed by the Engineer-In-Charge. LOWER GROUND FLOOR
PLUMBING WORK C P and Sanitary Fixtures and Fittings Providing and fixing European type wall hung white water closet of Parriware / Hindware with push valve concealed type with cover plate 32 millimetre size of JAGUAR MAKE Series FLV-1095 including soil pipe, vent pipe upto outside face of wall, 100 millimetre diameter galvanised iron plug bend inlet pipe all fittings, cutting and making good walls, floors etc complete. Lower Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing white Wash basin with half pedestal of size 515 millimetre X 615 millimetre X 460 millimetre including pillar cock auto-closing system chromium plated angular stop cock long thread of approved make continental including stainless steel bottle trap of necessary pipe connection upto the outside face of the wall. Lower Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing Table top white wash basin of size 120 x 635 x 405 millimetre rubber plugs and brass chain, with pillar cock, chromium plated Angular stop cock long thread, continental including Stainless steel bottle trap of approved make having necessary pipe connection upto the out side face of the wall. etc complete as directed by Engineer incharge. Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing white glazed urinal of size 710 x 460 x 300 millimetre with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 millimetre diameter meter Poly vinyl chloride flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap and soil pipe connection upto the outside face of wall etc complete. Lower Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing stainless steel sink of size 600 x 510 x 200 millimetre incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing chromium plated Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. Lower Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing chromium plated sink cock with raised J" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete." First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing chromium plated Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. Lower Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing 450 millimetre x 550 millimetre size superior type Belgium mirror with 16 millimetre diameter . nickel plated towel rod etc. complete. Lower Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing Hand shower (health faucet) with 8 millimetre diameter . 1m long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. Lower Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing, laying and fixing Poly vinyl chloride pipe of 50 millimetre diameter . with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Lower Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing 75 millimetre diameter stabilizer pipe / Poly vinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. (As per IS 13592-1992 Type B, 6 kg/sq. centimetre pipes are reco millimetre ended for use in soil and waste discharge system) Lower Ground Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and fixing 100 / 110 millimetre diameter stabilizer pipe / Poly vinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. (As per IS 13592-1992 Type B, 6 kg/sq. centimetre pipes are reco millimetre ended for use in soil and waste discharge system) - Lower Ground Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and fixing Poly vinyl chloride Rain water pipes of 110 millimetre outer diameter meter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly vinyl chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on cement concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly vinyl chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Lower Ground Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing 15 centimetre rigid Poly vinyl chloride Nahani trap including Poly vinyl chloride grating ,bend,connectingpiece of Unplasticized Poly vinyl chloride pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Lower Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing 10 centimetre Poly vinyl chloride nahani trap with grating etc. complete. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing on walls/ceiling/floor 20 millimetre diameter . CPoly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Lower Ground Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing on walls/ceiling/floor 25 millimetre diameter . Chlorinated Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and fixing on walls/ceiling/floor 32 millimetre diameter . Chlorinated Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Lower Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and fixing on walls/ceiling/floor 40 millimetre diameter . Chlorinated Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Basement Floor
Lower Ground Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and fixing on walls/ceiling/floor 50 millimetre diameter . Chlorinated Poly vinyl chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete. Lower Ground Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and laying in trenches 50 millimetre diameter . heavy grade having embossed as ISI Mark galvanised iron pipes of 6.33 kilogramme per metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Works Department chowky or as directed etc. complete.
Providing and fixing screw down for 20 millimetre diameter . wheeled stop tap of brass including necessary sockets/union nut complete. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Providing and fixing screw down for 25 millimetre diameter . wheeled stop tap of brass including necessary sockets/union nut complete. Eight Floor
Terrace Floor
Providing and fixing screw down for 32 millimetre diameter . wheeled stop tap of brass including necessary sockets/union nut complete. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and fixing screw down for 40 millimetre diameter . wheeled stop tap of brass including necessary sockets/union nut complete. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Terrace Floor
Providing and fixing screw down for 50 millimetre diameter . wheeled stop tap of brass including necessary sockets/ union nut complete. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Terrace Floor
Providing and fixing screw down for 65 millimetre diameter . wheeled stop tap of brass including necessary sockets/ union nut complete. Terrace Floor
Providing and fixing screw down for 80 millimetre . diameter . wheeled stop tap of brass including necessary sockets/union nut complete. Terrace Floor
Providing and fixing 50 millimetre diameter meter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [without chamber]
Providing and fixing 45 centimetre wide mild steel ladder of 40 millimetre x 6 millimetre mild steel flat stringers and steps of 18 millimetre diameter . mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 centimetre x 30 centimetre x 30 centimetre and painting the ladder complete. (Anti Corossive Paint)
Providing and fixing 40 millimetre . diameter Ball cock medium type with Poly vinyl chloride float including sockets and necessary fittings and tested as per municipal requirements etc. complete.
Providing and laying concrete pipes of Indian Standard Non-pressure class of 300 millimetre diameter meter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450 millimetre diameter meter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and fixing 15 centimetre x 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 out side the building including cast iron grating in the sink , connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round glazed stoneware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced cement concrete . Cover medium duty 140 kilogramme with frame etc complete.
Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECO with prior approval of concerned Superitending Engineer.
RWH - Recharge Pit Providing and constructing recharge pit of 2.0 metre deep and 1.0m diameter of pre-cast Reinforced cement concrete rings with 6.5' diameter x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated Poly vinyl chloride casing pipe wrapped around with netlon mesh including 300 millimetre thick sidefilling around outside of Reinforced cement concrete rings (annular space) with 40 millimetre size boulders including filling of recharge pit up to 0.5m depth with 25-75 millimetre clean washed gravels from bottom up followed by 0.5m depth of 10-25 millimetre of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand Vertical shaft impact (VSI) grade finely washed etc.) me diameter layer including covering with Reinforced cement concrete slab, manhole frame and cover, Poly vinyl chloride rungs, Poly vinyl chloride end-caps, fittings etc. including arrangement for inlet and outlet pipe excavation and backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
Providing and fixing 5" SS-304 Floor Graiting with jali for Floor Trap of approved brand and with SS Square Frame / Round Frame fixing as per manufacturer reco millimetre endation or per approval of the Engineer.
Providing and Fixing Chlorinated Polyvinyl Chloride (CPoly vinyl chloride ) Pipes of 65 millimetre nominal outer diameter pipes, having thermal stability for hot and cold water supply, including all CPoly vinyl chloride plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPoly vinyl chloride solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer.
Providing and Fixing Chlorinated Polyvinyl Chloride (CPoly vinyl chloride ) Pipes of 80 millimetre nominal outer diameter pipes, having thermal stability for hot and cold water supply, including all Chlorinated Poly vinyl chloride plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPoly vinyl chloride solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer.
Providing and constructing burnt brick masonry circular manhole without conical shape excluding excavation, Reinforced cement concrete 1:2:4 proportion, 20 centimetre bedding brick masonry in centimetre 1:4 proportion, 23 centimetre thick for 2 M depth from top 35 centimetre thick for 2 M below it and 45 centimetre thick for balance depth, Reinforced cement concrete slab at top and at 2 M. depth from top for supporting brick masonry above it, plastering with smooth finish in centimetre 1:2 proportion, C.C. 1:2:4 finishing channels in smooth rendering, providing C.I. dapuri type steps each weighing 5.5 kg., providing and fixing S.F.R.C. frame and co ver of 56 centimetre diameter . at top including cost of all materials and labour, etc. complete. - 1.00 M diameter . x 3 M depth Rebate for every decrease in depth of 50 centimetre or part there of SECTION L-CHAMBERS, MANHOLES DRAINAGE DROUPS SR.NO.-9 B
Providing and fixing intercepting sewer trap including concrete bedding, etc. complete. SECTION L- CHAMBERS, MANHOLES DRAINAGE DROUPS SR.NO.-18 B
RT1 -RECEPTION TABLE TABLE Providing and fixing table in "C" shape of size 2.4 m x 1.20 m having height of 750/1200 millimetre as shown in drawing made up of 19 millimetre thick plywood for vertical top , drawers, cabinates, foot rest of Century make Commercial Ply BWR grade conforming to ISI-303 or equivalent make. The top and facia shall be finished with, 4 millimetre thick veneer finish to ply surface as per detailed drawing, inner side to be finished with 0.8 millimetre thick laminate of royal touch or equivalent make confirming to (ISI-2046) including antitermite treatment , melamine polishing 2 costs to all veneer surface, fevicol, nails, cable manager, hinges, knobs, sliding chanels of hafele or equivalent make, with required labours, etc. All samples must be approved by the Project Architect and work must be done as directed by Engineer-in-charge. Lower Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
T2 -MULTIPURPOSE HALL AND MEETING TABLE Providing and fixing table of size 4.9 m x 0.75 m, having height of 750 millimetre as shown in drawing made up of 12 millimetre / 19 millimetre thick plywood of Century make Commercial Ply BWR grade conforming to ISI-303 or equivalent make. The top and facia shall be finished with, solid 6 millimetre thick, 4 millimetre thick veneer finish to ply surface as per detailed drawing, top surface bottom to be finished with 0.8 millimetre thick laminate of royal touch or equivalent make conforming to (ISI-2046), antitermite treatment, melamine polishing two coats to all veneer surfaces, fevicol, nails, cable manager, labours, material testing charges etc. All smaples must be approved by the Project Architect and work must be done as directed by Engineer-in-charge. First Floor
Sixth Floor
T5 A - STO'S TABLE Providing and fixing table in "C" shape of size 2.25 m x 0.90 m, side table 1.0 m x 0.45 m, back side table 2.25 m x 0.45 m having height of 750 millimetre as shown in drawing made up of 12 millimetre and 19 millimetre thick plywood conforming to ISI-303, The top and exposed surface shall be finished 4 millimetre thick of approved veneer,. at top surface only wooden beading 12 mm. x 40 mm. finished with melamine polish, all the support Plywood with 19 mm. thick plywood conforming to ISI-303. Internal surfaces finished with 0.8 mm. thick laminate, including provision for cable manager, plywood foot rest finished with 1 millimetre thick laminate, including shutters & drawers with telescopic sliders of required sizes, handles, lock hinges, magnet etc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods etc. complete. All samples must be approved by the Project Architect and work must be done as directed by Engineer-in-charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
CORNER WORKSTATION 1350x1350x600x1200 millimetre height. (CLUSTER OF 1) Providing and fixing of workstations System 50 millimetre Thk. Tile Base Partition System at 1200 millimetre height, 1st Module with Prelam particle board Tile, 2nd Module Pin-up, Marker and Fabric Tile, Electrical connection below the worktop on Raceway and Skirting Level, Table Top considered in 25 millimetre thick prelam particle board finish with Poly vinyl chloride lipping 2 millimetre thick having height 727 millimetre from Ground Level, Understructure with Prelam Gable Ends with Brackets and Return Prelam Combo Storage having size 750x400x 727 millimetre etc complete as directed by Engineer -In-Charge. Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
CORNER WORKSTATION 1350x1350x600x1200 millimetre height . (CLUSTER OF 6) Providing and fixing of workstations system 50 millimetre Thk. Tile Base Partition System at 1200 millimetre height,1st Module with Prelam particle board Tile, 2nd Module with Pin-up, Marker and Fabric Tile, Electrical fitting Below the worktop on Raceway and Skirting Level, Table Top considered in 25 millimetre thick prelam particle board finish with Poly vinyl chloride lipping 2 millimetre thick. Worktop height 727 millimetre from Ground Level, Understructure with Prelam Gable Ends with Brackets, Return Prelam Combo Storage having size 750x400x 727 millimetre etc complete as directed by Engineer -In-Charge.
High Back Revolving Chairs Providing and fixing High Back Revolving Chair Chair in Moulded Ply with Head rest, PU foam in Back and Moulded PU Seat, "T" Adjustable Arms , Synchronized Multi Lock Mechanism, Aluminium Base, and Gas Lift. as per the sample approved by Architect, etc complete as directed by Engineer In-Charge. Back Height - Medium Back Back Finish - Mesh with Adjustable Lumber Support Back Mesh Color - Black Seat Finish - Fabric (with centimetre Foam) Seat Fabric Color - Black Seat Height Adjustment - Pneumatic Mechanism Type - Synchronized Tilt Back Tilt Lock - Upright Position Back Tilt Tension - Adjustable Armrests Type - 1-D Adjustable Armpads Type - Polyurethane Base Type - 5-Star in Black Nylon First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Mid Back Sledge Base Providing and fixing Medium Back Chair with SS sledge base Chair in Moulded Ply, PU foam in Back and Moulded PU Seat, "T" Adjustable Arms , with SS sledge base.as per the sample approved by Architect, etc complete as directed by Engineer In-Charge. SPECIFICATIONS: Back Height - Medium Back Back Finish - Mesh with Adjustable lumber support Back mesh colour and seat colour - Black Seat Height Adjustable with gas Lift. Mechanism Type - Synchronized Tilt Back Lock - Upright position Back Tilt Tension - Adjustable Armrests Type -1D PU Arms Base Type - Black Nylon 5-Star Base. Lower Ground Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Low Back Sledge Base Providing and fixing Low Back Chair with SS sledge base Chair in Moulded Ply with Head rest, PU foam in Back and Moulded PU Seat, Adjustable Arms, With SS sledge baseas per the sample approved by Architect, etc complete as directed by Engineer In-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Fix Chair with Four Leg Providing and fixing Fix Lounge Chair Chair With Stainless Steel Frame in front 25 millimetre diameter and Back Leg Rectangle pipe . 12 millimetre Moulded ply in Seat and Back duly Cushioned with PP Arms as per the sample approved by Architect, etc complete as directed by Engineer In-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Dinning Chairs Providing and placing injection molded Polypropylene without handle chair of size 450 millimetre x 560millimetre and height 815 millimetre made up of primarily of 7/16" diameter meter steel rod with fire retardant power coating, injection molded Polypropylene seat and back etc. complete as per drawing and image and as directed by Engineer-In- Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Three Seater Sofa in Waiting Area Providing and fixing Frame in Hardwood fully Cushioned in Seat and Back, with arms. Stainless Steel Legs at the base. Three Seater Sofa - 1950 millimetre W x 750 millimetre D x 750 millimetre H Armrest 150 millimetre with Curve- Seat 550 millimetre , as per the sample approved by Architect, etc complete as directed by Engineer In Charge. Third Floor
Seventh Floor
Three Seater Sofa in Additional Co millimetre issioner Cabin Providing and fixing Frame in Hardwood fully Cushioned in Seat and Back, with arms. Stainless Steel Legs at the base. Three Seater Sofa - 1950 millimetre W x 750 millimetre D x 750 millimetre H Armrest 150 millimetre - Seat 550 millimetre Seat Height 425 millimetre as per the sample approved by Architect, etc complete as directed by Engineer In-Charge. First Floor
Third Floor
Fourth Floor
Sixth Floor
Seventh Floor
Two Seater Sofa in Waiting Area Providing and fixing Frame in Hardwood fully Cushioned in Seat and Back, with arms. Stainless Steel Legs at the base. Two Seater Sofa - 1350 millimetre W x 750 millimetre D x 750 millimetre H Armrest 150 millimetre with Curve- Seat 550 millimetre , as per the sample approved by Architect, etc complete as directed by Engineer In Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Center Table in Ante Chamber Providing and fixing Table in Stainless Steel Square pipe frame of 25 millimetre x 16g. Top and bottom with Smoke Glass with polished edges of 12 millimetre thk. Size:- 900 millimetre L x 600 millimetre W x 450 millimetre height as per the sample approved by Architect, etc complete as directed by Engineer In-Charge. First Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Center Table in Waiting Area Providing and fixing Table Table With Top in BSL of 25 millimetre thk with all Sides Edge Banding, Frame in Stainless Steel / M.S Powder Coating with 25 millimetre square pipe of 16g.table Size 900 millimetre L x 600 millimetre W x 450 millimetre height as per the sample approved by Architect, etc complete as directed by Engineer In-Charge. First Floor
Seventh Floor
Eight Floor
Side Table in Ante Chamber Providing and fixing Table in Stainless Steel Square pipe frame of 25 millimetre x 16g. Top and bottom with Smoke Glass with polished edges of 12 millimetre thk. Size:- 900 millimetre L x 600 millimetre W x 450 millimetre height as per the sample approved by Architect, etc complete as directed by Engineer In-Charge. First Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Side Table in Waiting Area Providing and fixing Table With Top in BSL of 25 millimetre thk with all Sides Edge Banding, Frame in Stainless Steel / M.S Powder Coating with 25 millimetre square pipe of 16g, table Size 600 millimetre L x 600 millimetre W x 450 millimetre height, as per the sample approved by Architect, etc complete as directed by Engineer In-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Curtains_DCST Cabin Providing and fixing Roller Blind MAC - SCREEN LI-S3 - Sand for windows, including all necessary fixtures and fittings, as per the sample approved by Architect, etc complete as directed by Engineer In Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Curtains_Conference and Computer Lab Providing and fixing Roller Blind MAC - BLACKOUT TORINO TR 5408 for windows, including all necessary fixtures and fittings, as per the sample approved by Architect, etc complete as directed by Engineer In Charge. Second Floor
Help desk _Credenza Providing and fixing Table of size 1.7 Metre x 0.4 Metre and top portion 1.7 Metre x 0.4 Metre having finished with white unicore laminate having height of 0.70 meter made up of 19 millimetre thick plywood and back made up of 12millimetre thick plywood (conforming to IS 303) finished, including shutters and drawers with telescopic sliders of required sizes, hinges, handles, lock , magnet, cable manager, knobs etc. as per working drawing, at Ground floor.etc. complete as directed by Engineer -In-Charge. Third Floor
Help desk _Credenza Providing and fixing Table of size 1.5 Metre x 0.45 Metre and top portion 1.5 Metre x 0.45 Metre having finished with white unicore laminate having height of 0.70 meter made up of 19 millimetre thick plywood and back made up of 12 millimetre thick plywood (conforming to IS 303) finished, including shutters and drawers with telescopic sliders of required sizes, hinges, handles, lock , magnet, cable manager, knobs etc. as per working drawing, at Ground floor.etc. complete as directed by Engineer -In-Charge. Second Floor
Fourth Floor
Fourth Floor
Sixth Floor
Seventh Floor
Item No. 22 - Help desk _Credenza Providing and fixing Table of size 1.35 Metre x 0.4 Metre and top portion 1.35 Metre x 0.4 Metre having finished with white unicore laminate having height of 0.70 meter made up of 19 millimetre thick plywood and back made up of 12millimetre thick plywood (conforming to IS 303) finished, including shutters and drawers with telescopic sliders of required sizes, hinges, handles, lock , magnet, cable manager, knobs etc. as per working drawing, at Ground floor.etc. complete as directed by Engineer -In-Charge. Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Item No. 23- Help desk _Credenza ( 1.75 Metre X 0.4 Metre) Providing and fixing Table of size 1.75 Metre x 0.4 Metre and top portion 1.75 Metre x 0.4 Metre having finished with white unicore laminate having height of 0.70 meter made up of 19 millimetre thick plywood and back made up of 12 millimetre thick plywood (conforming to IS 303) finished, including shutters and drawers with telescopic sliders of required sizes, hinges, handles, lock , magnet, cable manager, knobs etc. as per working drawing, at Ground floor.etc. complete as directed by Engineer -In-Charge. Fifth Floor
Sixth Floor
Help desk _Credenza ( 1.7 Metre X 0.6 Metre ) Providing and fixing Table of size 1.7 Metre x 0.6 Metre and top portion 1.7 Metre x 0.6 Metre having finished with white unicore laminate having height of 0.70 meter made up of 19 millimetre thick plywood and back made up of 12 millimetre thick plywood (conforming to IS 303) finished, including shutters and drawers with telescopic sliders of required sizes, hinges, handles, lock , magnet, cable manager, knobs etc. as per working drawing, at Ground floor.etc. complete as directed by Engineer -In-Charge. Seventh Floor
Help desk _Credenza ( 2.4 metre X 0.45 metre) Providing and fixing Table of size 2.4 Metre x 0.45 Metre and top portion 2.4 Metre x 0.45 Metre having finished with white unicore laminate having height of 0.70 meter made up of 19 millimetre thick plywood and back made up of 12 millimetre thick plywood (conforming to IS 303) finished, including shutters and drawers with telescopic sliders of required sizes, hinges, handles, lock , magnet, cable manager, knobs etc. as per working drawing, at Ground floor.etc. complete as directed by Engineer -In-Charge. Lower Ground Floor
Meeting Room Table Providing and fixing meeting room table in "C" shape of two similar sides of size 6.75 metre x 0.70 metre, front side of size 0.75 metre x 2.3 metre, having height of 750 millimetre as shown in drawing made up of 12 millimetre / 19 millimetre thick plywood , The top shall be finished with white solid surface, all the support Plywood Conforming to ISI-303 19 millimetre thick outer face finished with veneer and inner face finished with 0.8 millimetre thick internal laminate, including provision for cable manager, raceways for cables and wires, 50 millimetre diameter . ss pipe with necessary fitting for foot rest finished with paint, including shutters and drawers with telescopic sliders of required sizes, hinges, handles, lock , magnet, cable manager, knobs etc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods and wooden surface etc.complete as directed by Engineer -In-Charge. Sixth Floor
Conference Table Providing and fixing conference room table of size 5.0 metre x 1.2 metre, having height of 750 millimetre as shown in drawing made up of 12 millimetre / 19 millimetre thick plywood Conforming to ISI-303 , The top shall be finished with veneer, all the support Plywood Conforming to ISI-303 19 millimetre thick face finished with white laminate, as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods and melamine polishing 2 coat to all veneer and wooden surface etc.complete as directed by Engineer -In-Charge. Third Floor
Wall wooden Panelling P1,P2,P3 ( Top Veneer) Providing and fixing wall panel of size 4.552 metre x 3.45 metre as shown in drawing made up of BWR grade 12 millimetre / 19 millimetre thick plywood, plywood panel fixed on 19 millimetre ply strip grid, panel finished with veneer and provide 4 millimetre thk groove on panel as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods and melamine polishing 2 coat to all veneer and wooden surface etc.complete as directed by Engineer -In-Charge. Lower Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Wall wooden Panelling P1,P2,P3 ( Top Veneer) Providing and fixing wall panel of size 4.552 metre x 3.45 metre as shown in drawing made up of BWR grade 12 millimetre / 19 millimetre thick plywood, plywood panel fixed on 19 millimetre ply strip grid, panel finished with veneer and provide 4 millimetre thk groove on panel as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods and melamine polishing 2 coat to all veneer and wooden surface etc.complete as directed by Engineer -In-Charge. First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
TV UNIT Providing and fixing TV Unit of size 1.3 metre x 0.30 metre, having height of 450 millimetre as shown in drawing made up of 19+19 millimetre thick plywood conforming to ISI-303, The top shall be finished with veneer, all the support Plywood Conforming to ISI-303 19 millimetre thick finished with white laminate, internal surfaces finished 0.8 millimetre thick internal laminate, including provision for cable manager, raceways for cables and wires,including shutters, handles, lock, hinges, cable manager, magnet etc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods etc. complete as directed by Engineer -In-Charge. First Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
WALL SHELF (1.8 metre x 0.45 metre ) Providing and fixing Wall Shelf of size 1.8 metre x 0.45 metre, having height of 400 millimetre as shown in drawing made up of 19 millimetre thick plywood conforming to ISI-303, The top shall be finished with veneer, all the support Plywood Conforming to ISI-303 19 millimetre thick, internal surfaces finished 0.8 millimetre thick internal laminate, including provision for cable manager, raceways for cables and wires,including shutters, handles, lock, hinges, cable manager, magnet etc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods etc. complete as directed by Engineer -In-Charge. Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
WALL SHELF ( 1.5 metre x 0.3 metre) Providing and fixing Wall Shelf of size 1.5 metre x 0.3 metre, having height of 400 millimetre as shown in drawing made up of 19 millimetre thick plywood conforming to ISI-303, The top shall be finished with veneer, all the support Plywood Conforming to ISI-303 19 millimetre thick, internal surfaces finished 0.8 millimetre thick internal laminate, including provision for cable manager, raceways for cables and wires,including shutters, handles, lock, hinges, cable manager, magnet etc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods etc. complete as directed by Engineer -In-Charge.
WALL SHELF ( 0.75 metre x 0.3 metre ) Providing and fixing Wall Shelf of size 0.75 m x 0.3m, having height of 175 millimetre as shown in drawing made up of 19 millimetre thick plywood conforming to ISI-303, The top shall be finished with veneer, all the support Plywood Conforming to ISI-303 19 millimetre thick, internal surfaces finished 0.8 millimetre thick internal laminate, including provision for cable manager, raceways for cables and wires,including shutters, handles, lock, hinges, cable manager, magnet etc. as shown in the drawing and design supplied by the Architect and antitermite treatment to all plywoods etc. complete as directed by Engineer -In-Charge. Fourth Floor
Fifth Floor
Sixth Floor
WALL Painting Providing and fixing Wall Painting up to size 0.9 Metre X 1.2 Metre as shown in drawing and design supplied by the Architect etc. complete as directed by Engineer -In-Charge. Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Compactor- TM2 - TWIN MOBILE Providing and fixing in position Godrej MakeTM2 - TWIN MOBILE Drive 3 Bay Push Pull Type Unit of Optimizer ( Storage solution of size 457DX915WX1980H milimeter made out of 0.8 millimetre thick CRCA (Colled Rolled Colad Annealed) Steel Conferming to indinan Standard:513 grade, Having 5 Loading level Formed by 4 no Adjustable Shelves, finished with fire retardent epoxy polyster powder coating of approved colour and shade with dry film Thickness of millimetre 40 microns overbaked with a controleed temprature of 180 deg. C to 200 degree C the undercarriage made up welded frame of HR sheet 3.15 millimetre Thick Conferming to Indian Standard : 10748 suitably fabruicated to taken the load base on confriguation having fastners labour etc complete. Basement1
Lower Ground Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Compactor- LD3-single last drive unit Providing and fixing in position Godrej Make LD3-single last drive unit 3 Bay Push Pull Type Unit of Optimizer ( Storage solution of size 457DX915WX1980H milimeter made out of 0.8 millimetre thick CRCA (Colled Rolled Colad Annealed) Steel Conferming to indinan Standard 513 grade, Having 5 Loading level Formed by 4 no. Adjustable Shelves, finished with fire retardent epoxy polyster powder coating of approved colour and shade with dry film Thickness of millimetre 40 microns overbaked with a controleed temprature of 180 deg C to 200 degree C the undercarriage made up welded frame of HR sheet 3.15 millimetre Thick Conferming to Indian Standard 10748 suitably fabruicated to taken the load base on confriguation having fastners labour etc complete Basement1
Lower Ground Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Compactor- SD3-single Static Drive cover unit Providing and fixing in position Godrej Make SD3-single Static Drive cover unit 3 Bay Push Pull Type Unit of Optimizer (Storage solution of size 457DX915WX 1980H milimeter made out of 0.8 millimetre thick CRCA (Colled Rolled Colad Annealed) Steel Conferming to indinian Standard 513 grade. Having 5 Loading level Formed by 4 no. Adjustable Shelves, finished with fire retardent epoxy polyster powder coating of approved colour and shade with dry film Thickness of millimetre 40 microns overbaked with a controleed temprature of 180 deg. C to 200 degree C the undercarriage made up welded frame of HR sheet 3.15 millimetre Thick Conferming to Indian Standard : 10748 suitably fabruicated to taken the load base on confriquation having fastners labour etc.complete. Basement1
Lower Ground Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Compactor- TM2 - TWIN MOBILE Providing and fixing in position Godrej Make TM2 - TWIN MOBILE Drive 2 Bay Push Pull Type Unit of Optimizer ( Storage solution of size 457DX915WX1980H milimeter made out of 0.8 millimetre thick CRCA (Colled Rolled Colad Annealed) Steel Conferming to indinan Standard:513 grade, Having 5 Loading level Formed by 4 no. Adjustable Shelves, finished with fire retardent epoxy polyster powder coating of approved colour and shade with dry film Thickness of millimetre 40 microns overbaked with a controleed temprature of 180 deg C to 200 degree C the undercarriage made up welded frame of HR sheet 3 15 millimetre Thick Conforming to Indian Standard : 10748 suitably fabruicated to taken the load base on confriguation having fastriers labour etc complete Basement1
Lower Ground Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Guide Rails Providing and fixing Guide Rails made out of 28 millimetre diameter bar placed on 1.2 millimetre thick MS plate above the floor level having standard of safety etc. Complete Basement1
Lower Ground Floor
Upper Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Fifth Floor
Sixth Floor
Seventh Floor
Eight Floor
Est.No. 113105 of 2022-23 Providing Internal & External Electrification, LV System, Fire Fighting System & Fire Alarm & PA System & 3 No of Lifts to IGR Office (B+G+8 Floor) Building for Inspector General Register (IGR) of Maharastra State at Bundgarden S.No.10A,Munjeri 38, Pune-01) Total 6 Sub Works Subwork No-1 : Internal Electrification work for Inspector General Register (IGR) @ Bundgardon Pune Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting 6 to 32 A SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected.
Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..
Supplying and erecting modular pop up Box 8 module erected with provided AV/ HDMI , RJ 45,6 A electrical sockets and switch on provided table .
Concealing of provided M.S./ PVC switch box in wall with finishing as per specification No: WG-PW/CW
Supplying and erecting PVC trunking (PVC casing-ncapping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-ncapping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Point wiring for light/fan/bell concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW
Point wiring for independent plug, concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm (2+1E) FR grade copper wires, modular type switch and socket, earthing and required accessories as per specification No WGPW/ SW
Wiring for plug on board with Switch socket concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FR/FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
Supplying & erecting mains with 2x2.5 sq.mm. and earth wire 1.5 sq.mm FR PVC copper wire, in HMS PVC conduit min. 20mm dia, as per specification No: WG-MA/PC.
Supplying & erecting mains with 2x4 sq.mm. and earth wire 2.5 sq.mm FR PVC copper wire in HMS PVC conduit min. 20mm dia, as per specification No: WG-MA/PC.
Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted suitable for SPMCB of 36 poles on iron /GI frame (horizontal busbar type) as per specification no. SWSWR/ MCBDB
Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted suitable for SPMCB of 24 poles on iron / GI frame (horizontal busbar type) as per specification no. SWSWR/ MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles) on iron/ GI frame. (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying and erecting single pole and neutral distribution board (SPNDB) surface/flush mounted with 2 poles for incoming and 10 poles for outgoing SP MCB’s on iron/ GI frame as per specification no. SW- WR/MCBDB
Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 40A to 63A, Cseries (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying, fixing and commissioning 4 pole RCBO ((residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 63A as per specification no SW-RCCB/RCBO
Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. WSWR/MCB
Supplying, fixing and commissioning 2 pole RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32A/40A as per specification no SWRCCB/ RCBO
Supplying, fixing and commissioning 2 Pole, RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 6/10/16/20/25A, as per specification no SW-RCCB/RCBO
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided istribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Providing & erecting 3 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 3 Pole MCCB of 200A,415V capacity with short circuit rating 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Supplying & erecting CRCA sheet metal one way enclosures suitable for DP MCB /TP MCB /FP MCB erected on angle iron/GI frame complete.
Supply, installing, testing and commissioning of compartmentalized common control panel for Electrical as per following details. All the components shall be housed in a common cubical made of 16 swg. M.S. sheet with required stiffeners ( if required). The panel shall be powder coated of approved colour both inside & out side. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height. (IP 65) Complete as per all accessories Complete as per all accessories. (As per specifications SW-SWR/MCB/MCCB/ACB) Main LT Panel. Incomer:630A, 4P, 50 kA, EDO ACB with Microprocessor based with Short circuit, Over load & Earth fault in built protections -2 Nos, ON,OFF,TRIP Indication Lamps -3 No's - 1 sets,2A, MCB's - 1 Nos., LED Type R - Y - B Phase Indicating Lamps -3 No's - 1 sets, Multi Function Digital Meter to Measure Current (A), Voltage (V) , Active Power (kW), Reactive Power (kVAr), Apparent Power (kVA), Energy (kWh & kVAh) and Power Factor (pf) with RS 485 Port for IBMS) - 1 No., Outgoing Feeders: 320A, 36 KA, FP, MCCB - 2 No.s, 200A, 16 KA, FP, MCCB - 2 No.s 100A, 16KA, FP, MCCB - 1 No.s 63A, 16KA, FP, MCCB - 5 No.s 16A, 16KA, FP, MCCB - 1 No.s Busbars Rating: 800A,3Phase,36KA,50Hz Al. Busbar
Supply, installing, testing and commissioning of compartmentalized common control panel for Electrical as per following details All the components shall be housed in a common cubical made of 16 swg. M.S. sheet with required stiffeners ( if required). The panel shall be powder coated of approved colour both inside & out side. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height. (IP 65) Complete as per all accessories (As per specifications SW-SWR/MCB/MCCB/ACB) HVAC Panel Incomer: 200A, 4P, 16 kA, Fixed Type, MCCB - 1 Nos. ON,OFF,TRIP Indication Lamps -3 No's - 1 sets. 2A, MCB's - 1 Nos. LED Type R - Y - B Phase Indicating Lamps -3 No's - 1 sets. Multi Function Digital Meter to Measure Current (A), Voltage (V) , Active Power (kW), Reactive Power (kVAr), Apparent Power (kVA), Energy (kWh & kVAh) and Power Factor (pf) with RS 485 Port for IBMS) - 1 No. Outgoing Feeders: 63A, 16KA, FP, MCCB - 6 No.s 32A, 16KA, FP, MCCB - 2 No.s Busbars Rating: 250A,3Phase,16KA,50Hz Al. Busbar
Supply, installing, testing and commissioning of compartmentalized common control panel for Electrical as per following details All the components shall be housed in a common cubical made of 16 swg. M.S. sheet with required stiffeners ( if required). The panel shall be powder coated of approved colour both inside & out side. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height. (IP 65) Complete as per all accessories (As per specifications SW-SWR/MCB/MCCB/ACB) LIFT Panel. Incomer: 100A, 4P, 16 kA, Fixed Type, MCCB - 1 Nos. ON,OFF,TRIP Indication Lamps -3 No's - 1 sets. 2A, MCB's - 1 Nos. R - Y - B Phase Indicating Lamps -3 No's - 1 sets. Multi Function Digital Meter to Measure Current (A), Voltage (V) , Active Power (kW), Reactive Power (kVAr), Apparent Power (kVA), Energy (kWh & kVAh) and Power Factor (pf) with RS 485 Port for IBMS) - 1 No. Outgoing Feeders: 63A, 16KA, FP, MCB - 5 No.s 16A, 16KA, DP, MCB - 4 No.s Busbars Rating: 125A,3Phase,36KA,50Hz Al. Busbar
Supplying and erecting 150 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP/APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CPED/ APFC
Supplying & erecting LED 20W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting LED square / circular 13 to 15W down lighter having pressure die-cast aluminum housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED flexible strip light 5m length upto 25W conforming IP 65 of any colour with driver complete.
Supplying and erecting 2 light fancy wall bracket with arm fabricated from brass duly lacquered with suitable holder and fancy glass shade duly wired erected on wall with suitable size of polished wooden / laminated board.
Supplying and erecting square / rectangular shaped CRCA /die-cast aluminium powder coated housing LED panel (slim edge-lit) light suitable for 25 to 32W with provision for plane front frame with translucent cover fixed to the housing complete.
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 36 W-40W with provision for plane front frame with translucent cover fixed to the housing complete.
Supplying and erecting LED Mirror Light with integrated driver including 7W to 9W lamp with polycarbonate housing and opal diffuser to be fixed above mirror or as required on clamps complete.
Supplying & erecting suspension type decorative pendent fitting single light with anodized aluminium / powder coated MS rod up to 1 m length and canopy on top provided with decorative glass shed duly wired with two core flat wire suitable lamp holder complete.
Supplying and erecting decorative oval bulk head edge-lit 10W LED luminaire comprising of high brightness LED Fitting on provided PVC block / wooden board.
Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Providing and erecting air circulator 600 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles A.C. supply, core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation.
Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan.
Supplying and erecting fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted.
Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting ISI mark modular type (two modules) electronic dimmer 600/650W, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
Supplying, erecting & terminating XLPE armoured cable 3½ core 300 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 120 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. copper conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor continuous 5.48 sq.mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 3 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
upplying , erecting & terminating 3 x 95 sq. mm. aluminium 22 kV(E), XLPE armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification no.CB-HT
Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware in approved manner
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware in approved manner.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 500 mm width & 20 mm height complete with necessary hardware in approved manner.
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying & erecting on line UPS pure sine wave of 10 kVA capacity complete with standard features,along with necessary SMF batteries for 30 mins battery backup, as per specification no. AP-UPS
Supplying & erecting on line UPS pure sine wave of 8 kVA capacity complete with standard features,along with necessary SMF batteries for 30 mins battery backup, as per specification no. AP-UPS
Supplying & erecting on line UPS pure sine wave of 6 kVA capacity complete with standard features,along with necessary SMF batteries for 30 mins battery backup, as per specification no. AP-UPS
Supply & Installation of Junction boxes for direct acess to cables at the intersection of raceways. Supply completely with base and cover plate (Lid) with height adjustable feature from 65mm to 90 mm. Confirms to standard EN 60-670,EN 50 085 - 2 - 2 & IEC 61534-22. . For adjustable junction box, resistance to vertical load applied over a small surface area should be 500N & resistance to vertical load applied over a large surface area should be 2000N. Use junction box with fly over for direct acess to cables at the intersection of floor raceways while maintaining perfect separation and 90 degree cross overs between data and power cables. 225mm X 225 mm X 65-90mm Junction Box
Supply & Installation of Junction boxes for direct acess to cables at the intersection of raceways. Supply completely with base and cover plate (Lid) with height adjustable feature from 65mm to 90 mm. Confirms to standard EN 60-670,EN 50 085 - 2 - 2 & IEC 61534-22. . For adjustable junction box, resistance to vertical load applied over a small surface area should be 500N & resistance to vertical load applied over a large surface area should be 2000N. Use junction box with fly over for direct acess to cables at the intersection of floor raceways while maintaining perfect separation and 90 degree cross overs between data and power cables. 300mm X 300 mm X 65-90mm Junction Box
Supply & Installaion of GI raceways made of pre-galvanished sheet with thickness of 1.5mm for distributing LV and ELV cabling in screed floors installations. Can be combined with junction boxes, backboxes (floorboxes) for wiring devices, fixing and coupler accessories. Consist of body & cover. Cover fitted on to the body with screws & can be opened easily if required. Particularly suitable for applications requiring EMC screening. Protection level should be IP 20 & IK 08. Standard length should be 2.44 mtrs. Confirms to standard EN 60-670, EN 50 085 - 2 - 2 & IEC 61534-22.. Resistance to vertical load applied through small surface area should be 1500 N & Resistance to vertical load applied through large surface area should be 3000 N. Race ways should be supplied with complete accessories i.e. fixing brackets & couplers for joining raceways from the same manufacturer. 50 mm X 38mm GI/Metal Raceway- One Compartment
Supply of GI raceways made of pre-galvanished sheet with thickness of 1.5mm for distributing LV and ELV cabling in screed floors installations. Can be combined with junction boxes, backboxes (floorboxes) for wiring devices, fixing and coupler accessories. Consist of body & cover. Cover fitted on to the body with screws & can be opened easily if required. Particularly suitable for applications requiring EMC screening. Protection level should be IP 20 & IK 08. Standard length should be 2.44 mtrs. Confirms to standard EN 60-670, EN 50 085 - 2 - 2 & IEC 61534-22.. Resistance to vertical load applied through small surface area should be 1500 N & Resistance to vertical load applied through large surface area should be 3000 N. Race ways should be supplied with complete accessories i.e. fixing brackets & couplers for joining raceways from the same manufacturer.- 150 mm X 38mm GI/Metal Raceway- One Compartment
Supply & Installaion of 38mm pre-galvanised Raceway Connector for coonection of two raceways
Supply & Installaion 50 mm X 38mm pre-galvanised Fixing Brackets
Supply & Installaion 150 mm X 38mm pre-galvanised Fixing Brackets
Supplying and erecting Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C. supply of 3.75 KW/5 HP with discharge 2/4.1 Litres per second (LPS) for head of 36/52 m and 50 mm suction/ 40 mm delivery pipe on provided C.C. foundation as per specification no. WP-CGP
Supplying & erecting Dewatering Submersible pump set 415V, 3 phase, 50C/s, A.C. supply of 1.5 KW/ 2 H.P., of 2 to 17 m head with 600 to 100 LPM discharge, non-clogging minimised abrasive wear, large impeler clearance & maintenance free pump set with water proof cable duly sealed with epoxy material built in protection to prevent the motor from burn out due to abnormal operation. specially designed high efficiency motor with F class insulation & the pump mechanically sealed in the oil chamber,. etc. complete as per specification no. DWP- SMP
Supplying & erecting Float sensor switch for water level controller working on 250V & rated current 8A, with 2 mtr. wire & High quality of wire & plastic body.
Supplying, erecting, testing and commissioning selfcontained water cooler 230/250V 50 cycles nominal cooling capacity of 40 litres/hr and storage capacity 80 litres with partially stainless steel body complete. specification no. APWCR/ WC
Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps, storage capacity of purified water 7 to 8 litre with activated carbon filter and softener operating on 230 V single phase A.C. supply.
Supplying, erecting, testing and commissioning of 6 HP,VRF / VRV air conditioning system, out door unit(ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning of 10 HP, VRF / VRV air conditioning system, out door unit(ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning of 18 HP, VRF / VRV air conditioning system, out door unit(ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning of 24 HP, VRF / VRV air conditioning system, out door unit(ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 0.6TR - 0.8TR ( 229 to 358 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling apacity 1.0TR (358 cfm) to 1.25TR (417 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and lectrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3TR (421 cfm) to 1.7TR (586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 1.0TR ( 441 cfm ) / 1.3TR ( 512 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 2.0TR ( 618 cfm ) / 2.3TR ( 671 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 2.6TR ( 918 cfm ) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 1.0TR ( 441 cfm ) to 1.3TR ( 512 cfm ) having EER as per BEE standards and specifications suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive oating suitable for coastal area complete in all respects, to operate on 1-phase 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 1.4TR ( 512 cfm ) to 2.0TR ( 618 cfm ) having EER as per BEE standards and specifications suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 1.8TR ( 575 cfm ) to 2.7TR ( 953 cfm ) having EER as per BEE standards and specifications suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning cordless remote contol having colour LCD panel, real time clock, temperature limitation (16 to 30 degree Cent.), functions like filter clean reminder timer suitable to communicate with wired controller complete.
Supplying & erecting mains 2x1.5 sq.mm. and earth wire 1.5 sq.mm FR PVC copper wire, ISI mark HMS PVC conduit min. 20mm dia, as per specification No: WG-MA/PC.
Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
Subwork No-2 Providing External Electrification for Inspector General Register (IGR) @ Bundgarden Pune Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micronmolecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. pecification no. EA-MOBI ( UPS-6 Nos)
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP (Metering Kiosk- 9 Nos, CSS-8 Nos, HT Cable-1 Nos, DG- 4 Nos, Panel Room-2 Nos, Lifts-6 Nos, LA- 4 Nos, Solar System-4 Nos)
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP. (Metering Kiosk, Compact Substation, DG Neutral)
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation in an approved manner.
Supplying and erecting LED Street light fitting suitable for Each above 40W to 48W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No . FG-ODF/FLS2.
Supplying and erecting Street light bracket for erection of Single fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC
Supplying and erecting steel tubular swan neck swaged type welded pole with upper portion hydraulically bent, 165.1 x 139.7 x 114.3 mm dia with 4.5 x 4.50 x 3.65 mm thickness (5 + 2 + 3 m) respectively (net vertical height 9 m.) total length 10 m long with base plate in provided foundation.(weight 156.75 kg) as per specification no. OH-PL/STP
Supplying, erecting, testing, commissioning 22 KV HT metering cubical (compact type) approved by MSEDCL/licensee fabricated with 2 mm (14 SWG) MS sheets with supporting angle and channel, painted with powder coating / epoxy paint of required shade copper bus bar size 25x6 mm electronic security lock and heavy duty mechanical lock, with counter meter for measuring no of times the opening of doors, top side cover (CT,PT cover) interlock with meter doors, epoxy coated 3 nos CT having required ratio between 5/5 A to 25/5 A, VA10, class 0.5S, 00/V3/110/V3 VA 50, class 0.5 epoxy terminal block suitable for provided trivector meter, and provision for incoming and outgoing cables etc. complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation
Supplying and Erecting approved make compact substation with 315 kVA, 3 phase, 50 Hz., ONAN type thermal class K10, 21 kA for 3 Sec. SF6 insulated non-extensible compact switchgear (type DVNE/RT2-NE) consisting of one no. direct cable module and one no. fixed manual vacuum circuit breaker in SF6 insulated stainless steel enclosure, with series trip, self powered microprocessor based numerical over current relay (IDMTL + Inst.) protection. Interconnection between HT switchgear and transformer shall be using 1Cx3x150 sq.mm aluminium unarmorured XLPE Cable. copper wound transformer 315 KVA 22 KV/433V Dyn11 oil filled, ermetically sealed transformer with corrugated wall, without conservator type of design & top normal porcelain bushings for HT & LT with off load tap switch of rating +5% to -10% @2.5%. temp rise - oil/winding 40/45°C losses (subject to IS 1180 energy efficiency level 2 ) - max @ 50% loading : as per IS 1180 and max @ 100% loading : as per IS 1180 and impedance as per IS 1180 with LV panel-500 amps aluminium busbar (100% for phase and 50% for neutral, current density - 1 amp/sqmm) with outgoings 500 A 433V 4P 50 Hz 35 kA ICOG fixed manual type moulded case circuit breaker (MCCB) with microprocessor based release for overload , short circuit & earth Fault protection, multifunctional meter with class 1.0 accuracy with RS 485 port, RYB, ON/OFF trip indications, outdoor enclosure having IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for transformer compartment, powder /colour coated enclosure, with interconnection between HT switchgear & transformer using 1Cx3x150 sq.mm XLPE aluminium single core cable. Interconnection between transformer & LT switchgear using aluminium busbars. Internal earthling connections by using 50x6 mm GI strips including transformer neutral, complete with necessary permissions of Electrical Inspector as per specification no. SSTR/ COMP
Supplying, erecting and commissioning of diesel generating set with alternator of 320 kVA output continuous rating, 3 phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, alongwith standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %. Both the engine and alternator direct coupled on a common fabricated steel base frame and ounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for diesel generating set of above 250 kVA upto 320 kVA capacity Single/Three phase, 230/415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GENAMF.
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete.
Making burnt brick masonry with 1:6 ratio cement concrete duly plastered including watering, streaking joint on exposed faces, rocking at joint on exposed faces and watering complete.
Supplying & arranging burnt cured bricks properly for various purposes (size 9”x4.25”x3”) at work for 100 bricks complete.
Supplying and erecting RCC chamber cover with frame 60cmx 45cm medium duty 100kg with lifting arrangement including laying of angle iron frame of angle size as 50 x 50 x6 mm to be fixed / embedded on top of chamber complete.
Supplying & laying (including excavation) 25 cm dia RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for covering provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) ( For Pumps, DG, Metering Kiosk, Comapact Substation).
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles)
Subwork No-3: CCTV , LAN & Telephone System for Inspector General Register (IGR) @ Bundgardon Pune Supply Installation commissioning of 4 MP Full HD IP Dome /Bullet Camera Image Sensor 1/3" 4 megapixel progressivescan CMOS Effective Pixels 2304 (H) × 1296 (V) Electronic Shutter Speed Auto/Manual 1-1/100000 s Min. Illumination 0.5 lux F2.1 (Color); 0 lux (IR LEDs on IR Distance - nUp to 100 ft (30 m) Day/Night -auto (ICR)/Color/BW Backlight Compensation - BLC/HLC/DWDR White Balance - Auto/Manual Gain Control - Auto/Manual Noise Reduction - 3D Privacy Masking- Up to 4 areas Lens Focal Length- 2.8 mm Horizontal Angle of View 92° 86°-28 Compression H.265 (Main/High/Baseline Profile) /MJPEG Resolution 3 MP (2304×1296) 1080p Main Stream 4 MP ,30 fps 16x Digital zoom 60 fps, Resolution- Verifocal lens, 320 db Corridor Mode Support Network Protocol IPv4/IPv6 HTTP HTTPS TCP/IP UDP UPnP ICMP IGMP RTSP RTP SMTP NTP DHCP DNS PPPoE DDNS FTP IP Filter QoS Compatibility -nONVIF Profile S CGI Max. User Access 20 users Mobile App - for iPhone iPad Android Phone and Tablet Power Supply PoE (802.3af) 12 V DC Working Environment -22°F to 140°F (-30°C to 60°C); 10% to 100% RH condensing Ingress Protection IP66 Vandal Resistance - IK10 Regulatory FCC Part 15B Class B (3 years warranty)
Supply and Installation of 8 TB Surveillance Storage Hard Disk Drive – 24/7 Surveillance HDD, Capacity- 8 TB, Interface- SATA III 6 Gb/s, Max Sustained Transfer Rate OD- 210 MB/s, Cache- 256 MB, Tarnish Resistant, Load/Unload Cycles- 300,000, Power-On Hours per Year- 8760, Mean Time Between Failures (MTBF)- 1 million hours, Operating Temperature - Ambient: 41°F / 5°C (min), Drive Case: 158°F / 70°C (max), Non-Operating Temperature Ambient: -40°F / -40°C (min)
Supplying, fixing, and configuring web smart power over ethernet switch of 24 ports on provided rack or as directed as per specification No. WG-NWC/ENS
Supplying, Erecting, Testing & Commissioning of Full HD commercial display DISPLAY-Screen Size 55-inch Aspect Ratio 16:9 Backlight Scanning 100Hz Resolution 1920 x 1080 pixels Viewing Angle178°/178° TERMINAL- VIDEO IN RCA X 1 AUDIO IN (L/R) RCA Pin Type X 2 HDMI IN HDMI 1.4 X 3 USB Input USB 2.0 X 2 RS232C Yes HDMI CEC Yes VGA IN Yes PC AUDIO IN Yes (1) (Share with AC)
Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 10 mtr cord length with male/female 19pin HDMI connectors as per requirements complete.
Supplying, fixing, and configuring 8-ports 10/100/1000Mbps unmanaged gigabit PoE Switch complete.
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 24 extensions suitable upto 96 extensions complete. (Total 288 Extensions)
Supplying & erecting telephone copper cable 2 pair with 0.5 mm dia. laid in provided PVC casing capping/ conduit as per specification No. WG-TW
Supplying & erecting telephone copper cable 100 pair with 0.5 mm dia. laid in provided PVC casing capping / conduit as per specification No. WG-TW
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 10 mtr cord length with male/female 19pin HDMI connectors as per requirements complete.
Supplying, erecting & commissioning Main distribution Frame (MDF) Box 50x50 pairs as per specification No. WGTW
Supplying, erecting & commissioning MDF Box 100 x 100 pairs as per specification No. WG-TW
Supplying, erecting & commissioning MDF Box 500 x 500 pairs as per specification No. WG-TW
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supplying and fixing 1 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring layer 3/ 20 10/100/1000 base-T ports + 4 combo 10/100/1000Base-T/SFP ports + 4 10GE SFP+ ports - SI Image as per specification complete.
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 450x550x367 mm) as per specification No. WG-NAS/RAK
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 450x550x500 mm) as per specification No. WG-NAS/RAK
Supplying and erecting PVC Surface modular switch box withdouble mounting plate for 2 modules duly erected.
Supplying and erecting PVC Surface modular double mounting plate 2 modules complete duly erected.
Supplying and erecting ISI marked modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type computer jack RJ 45 with safety shutter, duly erected on provided plate and box with wiring connections complete
Concealing of provided M.S./ PVC switch box in wall with finishing as per specification No: WG-PW/CW
Supplying, installing, testing & commissioning approved type Digital key telephone / IP telephone instrument as per specification complete.
Supply. Erecting, Testing and commissioning Ultra interactive projector with 5000 ANSI lumens, Product dimensions 36.7 x 4 x14.9 cm, 5.9 Kilograms, Hardware interface: VGA , US, Ethernet, HDMI, 3.5mm. Audio resolution: WXGA display technology: LCD Display type: LCD digital zoom:1.35 X Aspect retion. 16:10 Noise Level: 28DB Wattage:311 Watts Batteries Included: No Battery required: No Total USB Ports:3, Remote control Included: Yes Manufacturer: Epson corporation item Weight: 5Kg 900g
Supply, Erecting, Testing and commissioning projector motorized screen: Aspect Ratio 16:9, Video quality:Full HD , 4k, 2D Features: Foldable size:8 X 10 Manufacturer: Inlight, Ansons Enterprises Item Weight: 22 Kilograms item part number: V_ 19 X 8 Special features: Outer to outer dimension of the metal container is 132 inches/11 Feet Batteries included: Yes Batteries Required: Yes
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 10 mtr cord length with male/female 19pin HDMI connectors as per requirements complete.
Supplying and erecting PVC box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX.
Supplying and erecting PVC trunking (PVC casing-ncapping) of size 40 mm with accessories on wall/ceiling asper specification No: WG-MA/CON.
Supplying and fixing 15U wall mount rack (Dimension- DxWxH – 450x550x767 mm) as per specification No. WGNAS/RAK
Supplying Installation Testing & Commissioning of Delegate Unit Microphone on/off button, Two headphone sockets, Acoustic Input at the microphone- 85dB SPL, Frequency Response- 400Hz to 10Khz , Length of the microphone from the base of the stem- 488mm, Operating temperature: -5 rC to +45 rC
Supplying Installation Testing & Commissioning of Chairman Unit,Priority button for chairman microphone, Microphone on/off button, two headphone sockets, Acoustic input at the microphone- 85 dB SPL, frequency Response- 400Hz to 10KHz length of the microphone with flexible stem of 488 mm in length and operating tempreture -5 °C to + 45 °C
Supplying, Installing, Testing & Commissioning of DCN Multi core Conference Technical specifications Mechanical Dimensions (dia.) 6 mm (0.24 in), Material PVC Color Grey, Similar Make: Bosch/ Mipro / Electro Voice
Supplying, erecting, testing and commissioning amplifier 120 W for public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
Supplying, erecting, testing and commissioning of 1.5 sq mm speaker wire complete
Supplying, Installation, Testing & Commissioning of Professional Quality Imported Power Amplifier 480 W with Built in Temperature controlled Fan, Overload Protection, Short circuit Protection. Voltage 24 VDC +15% / -15%, Current max 30 A, Performance, Output power (rms/maximum) 480 W / 720 W, Power reduction on backup power -1 dB, Frequency response 50 Hz to 20 kHz (+1/3dB @ 10 dB, ref. rated output) Distortion <1% @ rated output power, 1 kHz, S/N (flat at max volume) >90 dB (2 Working + 1 Std. By),
Supplying and erecting PVC trunking (PVC casing-ncapping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying, erecting, testing and commissioning microphone complete as per specification no. FF-PA/MIC
Supplying, erecting, testing and commissioning stand for microphone complete.
Subwok No-4: Fire Alarm & Detection, Fire Fighting & Public Address System Supply, Installation, Testing & Commissioning of UL listed 4 Loop Analog Addressable Fire Alarm control panel having the capacity of 252 devices / detectors per loop any combination. The panel shall have 32 bit Central processor with 5000 Event History logging with On Line & Offline reports and having large, 6" (15.2 cm) (1200 −x− 800 pixel) color liquid-crystal display (LCD), touch screen and LEDs for displaying system status. LCD Display status highlights Alarm events appear in red; Trouble events appear in yellow; Supervisory events in blue, and Security events in magenta. The panel shall have 12 Amps inbuilt power supply having charging capacity of maximum 100AH Lead Acid battery. In case of networking, the panel shall have network card included inside the panel for RS485 communication with other display devices like Graphic screen, repeater panel etc. The panel shall be modular and shall have the capacity of expanding upto 10 Loops and 2500 devices/detectors maximum. The panel shall support degrade mode operation and shall have battery backup of 24 hrs in normal condition and 30 minutes in Alarm condition. Panel shall feature to view a graphics map, which can show a simple building floor plan. On the map, the user will see an icon indicating the location of the event in the building in addition to a 'You-Are-Here' symbol to tell the responding person exactly where they are in the building in relation to the event.The panel shall also have the provision to connect Integrated two way 8 Zone addressable Fire Fighter Fighter Telephone System of same make. Vendor to provide battery calculation sheet.
Supply, Installation, Testing & Commissioning of UL Listed Network Repeater Panel. The panel shall be able to give location of all fire and fault and Isolation conditions of addressable units of main Fire Alarm panel via the address codes. Panel shall have feature to Acknowledge/ Slience/ Reset. The panel shall have a LCD display and having maximum 160 (4 x 40) Characters in the display. It has menu system which is designed to allow the user to scroll through the entire system in either the Physical or Geographic views to locate the area of the system desired – all without having to know module or device addresses as well. The panel shall also cabinet & required accessories complete (at security gate )
Supply, Installation, Testing and Commissioning of UL listed Intelligent Addressable Muliti Criteria detector with photoelectric, thermal, and false alarm resistance along with standard base. It shall be an intelligent digital photoelectric detector with a programmable heat / ROR function, with self testing function. The detector shall have tri color LED. It shall be Polarity Insensitive and facility to mount in different comprehensive environment like Precious storage, Transformer rooms, Ware house and normal working environments. Including with all requried mounting accessories. (for below & Above false ceiling)
Supply, installation, testing & commissioning of Addressable single action Manual Call Points ). The same shall be square in shape & made of ABS plastic material. Surface / Flush Mounting. It shall have a "Pull in case of fire " message embedded on the MCP. The addressable module shall be enclosed in a junction box & with required accessories.
Supply, installation, testing & commissioning of Conventional Strobe cum Sounder. The strobe cum sounder shall be made of ABS plastic material & have the Db level of minimum 85dBs and a multi tone facility, The strobe shall be ajustable to 110 candelas. wall / ceiling mounted with mounting base & required accessories complete.
Supply, installation, testing & commissioning of Response indicator for Above false ceiling detectors with required acessories..
Supply, installation, testing & commissioning of Multi Output 24V/10A DC SMPS Power Supply Unit with battery backup, enclosure & required accessories. Should have potential free contacts for monitoring the fault status of power supply & battery failure.
Supply, installation, testing & commissioning of Addressable Control Module with surface/wall/ceiling mounting box & required accessories complete. For Sounder / Strobe Cum Sounder
Supply, installation, testing & commissioning of Addressable Monitor Module with Surface/wall mounting box & required accessories. Complete Integration of Cable from MM to third party system panel are also included in scope along with commissioning. For Sprinkler Flow Switch Integration ,SMPS Power supply fault Integration
Supply, installation, testing & commissioning of Addressable Relay Control Module with surface/ wall mounting box & required accessories complete (for Third party integration). Integration of Cable from RCM to third party system panel are also included in scope along with commissioning. For PA System,Fire Fighting Telephone, Lift Integration
Supply , installation and testing & Commissioning of approved intelligent Addressable Fault isolator Modules.
Supply installation Testing & commissioning of Addressable Fire Fighter Telephone Jack with metal junction box & required accessories.
Supply installation Testing & commissioning of 4 Nos. Fire Fighter Telephone handset with metal enclosure to accommodate all telephone handset in same enclosure. (Handset to be placed near Fire alarm control panel)
Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supply, installation, testing & commissioning of 6 Watt Ceiling type Mounted Speakers with line matching transformer, Power tapping: 1.5W/3W & screw clamp mounting with required accessories.
Supplying, erecting, testing and commissioning microphone complete as per specification no. FF-PA/MIC
Supply, installation, testing & commissioning of IP based 4 zones fully programmable DSP audio processor/controller with following features:- Min 6 music Inputs, 1 telephone interface input, 18 zones output, excellent sound quality min 96kHz sampling rate, 100MB in-built memory for 36 minutes recordable message player, 16 control inputs & 8 remote TTL outputs for fire alarm system integration, scheduler & event management, RS232 port for third party control, RS485 Port for digital microphones remote controllers, ambient noise sensing, mixers & cross-overs. Audio processor/controller shall be UL or EN54-16 approved & certified. The mentioned controller shall include the router extension and required accessories
Supplying, erecting, testing and commissioning amplifier 120 W for public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
Supply, installation, testing & commissioning of professional CD/DVD player with USB flash port & 19" rack mount arrangement for use etc. vide technical specification.
Supply, installation, testing & commissioning of local volume control-cum ON-OFF switch with (Bypass provision) flush mounting metal back boxes.
Supplying and fixing 9U wall mount rack (Dimension-DxWxH– 450x550x500 mm) as per specification No. WG-NAS/RAK
Supplying, installing, testing of 2c x 1Sq.mm twin twisted cables multi- standerd shielded insulated straight FRLS armoured cable ( for 12 w speaker ,booster amplifier to centeral mixer amplifier and call center)
Supplying and erecting gong with double coil suitable for 230V complete erected on polished wooden block.
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete.
Supply erection of emergency start / stop push button station weather proof type for Booster pump at terrace level & at Reception.
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of booster pump of 450 LPM at 35 m head 7.5 HP (5.5 KW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/BP
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of fire service main multi stage pump, of 2800 LPM at 88 m head centrifugal type, 75 HP (55 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/MSC
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of jockey pump of 240 LPM at 105 m head 20 HP (15 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF-MFP/JP
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 2850 lpm at 88 m Head
Supplying and erecting cast iron foot valve ball type/flap type of size 150 mm dia with strainer for negative suction complete as per specification no. FF-VL/FV
Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/PG
Supplying and installing air vessel of 300 mm dia 1.5m in height M.S. tank installed inside pump house / on terrace complete as per specification no. FF-FFA/ACT
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 200 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 150 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 25 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting cast iron double flange sluice valve 200 mm dia. complete as per specification no. FF-VL/SV
Supplying and erecting 200 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 150 mm dia end line strainer for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting cast iron double flange NRV of size 150 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 75/80 mm dia complete as per specification no. FF-VL/NRV
Supplying & erecting cast iron double flange butterfly valve of size 200 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 75/80 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 50 mm dia. complete as per specification no. FF-VL/BFV
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying & erecting gun metal gate valve of size 25 mm dia complete as per specification no. FF-VL/GV
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying fire fighting controlled percolation (C.P.) Hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/CPH
Supplying & erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ
Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) fitted with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/FBC
Supplying and erecting fire brigade header (Siamese connection) of 150 mm dia for supplying water to wet riser system complete as per specification no. FF-FFA/SMC
Supplying and erecting one no. brass orifice plate having 6 mm. thickness, 140 mm outer dia and required/proper diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting D.C.P. type fire extinguisher 9 kg capacity cartridge type with Gun Metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete.
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying, erecting, testing and commissioning of 15 mm (½") dia. NBCM Body chrome finished quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR.
Supplying, installing, testing, and commissioning standard response conventional sprinkler quartzoid bulb type with 15mm screwed end connection of 68 deg. C.temperature rating K80 and orifice shall not be less than 6mm sprinklers shall be UL listed / FM approved with chrome finished. (Side Wall sprinkler)
Supplying, installing, testing, and commissioning standard response conventional sprinkler quartzoid bulb type with 15mm screwed end connection of 79 deg. C.temperature rating K80 and orifice shall not be less than 6mm sprinklers shall be UL listed / FM approved with chrome finished. (Pedant Sprinkler)
Supplying, installing, testing, and commissioning standard response conventional sprinkler quartzoid bulb type with 15mm screwed end connection of 68 deg. C.temperature rating K80 and orifice shall not be less than 6mm sprinklers shall be UL listed / FM approved with chrome finished. (Upright Sprinkler)
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1500mm
Supplying, erecting, testing and commissioning vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 75/80 mm dia having following features 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4) Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes
Subwork No-5 : Providing 3 Nos of Lifts to Inspector General Register (IGR) @ Bundgardon Pune SITC of Electric Traction Service Lift with Rated capacity :- 13 Passenger/884Kg • Floors :- B+LG+UG+8 Floor (11Stops/11 Landings) • Travel :- 3 to 37.5 mtrs. • Location of Lift Machine:- MR/MRL • Rated speed :- 1.0mps VS • Doors type :- COPO/TOPO Doors with frame having clear opening of 900 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/ frames • Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS hequered plate flooring, handrails, mirror, emergency light etc. • Clear Car size of 1100 mm wide x 2000 mm deep x 2200 mm high • LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings • Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor /control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class • ARD complete with necessary SMF VRLA batteries • Fireman controller having fireman switch at fire Landing, • CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. • Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength • Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work • Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. • Lift shaft available having clear size of 2050 mm wide x 2730 mm deep, 1500 mm Pit depth, 4350 mm Overhead. Notes 1) General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.2) Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule.
SITC of Electric Traction Passenger Lift with Rated capacity :- 10 Passenger/680Kg • Floors :- LG+ UG +8 Floor + Terrace (11Stops/11 Landings) • Travel :- 3 to 4.2 mtrs. • Location of Lift Machine:- MR/MRL • Rated speed :- 1.0mps VS • Doors type :- COPO/TOPO Doors with frame having clear opening of 800 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/ frames. • Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS hequered plate flooring, handrails, mirror, emergency light etc. • COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor • Clear Car size of 1300 mm wide x 1350 mm deep x 2200 mm high • LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings • Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor /control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class • ARD complete with necessary SMF VRLA batteries • Fireman controller having fireman switch at fire Landing, • CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. • Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complet with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength • Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work • Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. • Lift shaft available having clear size of 2000 mm wide x 2100 mm deep, 1500 mm Pit depth, 4350 mm Overhead. Notes : 1) General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. 2) Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule.
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor ontinuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 2 core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 modules duly erected.
Supplying and erecting bulkhead fitting suitable for upto LED upto 12W fixed on wall. As per specification no. FG-IDF/BHF
Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendent holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box.
Supplying and erecting single pole and neutral distribution board (SPNDB) surface/flush mounted with 2 poles for incoming and 10 poles for outgoing SP MCB’s on iron/ GI frame as per specification no. SW-SWR/MCBDB
Supplying, fixing and commissioning 4 pole RCBO ( (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 63A as per specification no SW-RCCB/RCBO
Supplying, erecting & marking SPN MCB 40A, B-series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB
Supplying, fixing and commissioning 2 pole RCBO (residual current breaker with overcurrent short circuit 10 kA and earth leakage protection), with 30/100/300 mA sensitivity and having capacity of 32A/40A as per specification no SWRCCB/ RCBO
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB
Subwork No-6 : Solar PV System Supplying, installing, testing and commissioning of 49 kWp capacity on grid solar power pack with GI mounting structure and inter connecting wires / cables without battery bank SPV modules and solar power conditioning unit of required capacity complete, with 5 years on site performance warrantee. Specification no. ESD-RT-ONG
Supplying and erecting AC three phase LT CT multifunction net meter DLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz, with backlit LCD display, optical port & RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey,TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer.
Shubham EPC Private Limited
M/s Nikhil Constructiongroup Private Limited
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid