Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAdmitted-Finance | ₹1.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.4 Cr+₹32.4 L (31.2%)Admitted-Finance 0053 LAXMI NARAYAN NIKATAN 110B C O SRIKANT RAI RAMSAR KUMAR TOLI BHAGALPUR BIHAR RAMSAR BHAGALPUR BIHAR 812002 | BHAGALPUR | BIHAR | 812002 | ₹1.4 Cr+₹32.4 L (31.2%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical 362 CHANPORA GULSHAN NAGAR CHANPORA BUDGAM JAMMU KASHMIR 190015 | SRINAGAR | JAMMU AND KASHMIR | 190015 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M/S GLOBAL ENTERPRISES L2 | INFRA COOL PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00 | Supply and Installation of Walls and Ceilings with Puf Panels 80 mm thick with the following specifications: Walls and ceiling shall be made up of 80 mm thick Puf Insulated Panels. The main columns will be made out of R H Steel section of size 122x61x3.60 mm conforming to IS 4923: 1997 to provide maximum strength. MS Base plate of size 250x250x8mm and top plate of size 200x150x8 mm will be welded to the columns. Base plates will be pre drilled with 4 Nos 18 mm dia holes and provided with anchor bolts at the bottom and normal bolts at the top of 16 mm dia. The Puf Panels shall be 80 mm thick with 0.5 mm thick PPGI Sheets on both sides. The Panels shall be manufactured on continuous automatic line with puf density 40 + 2 Kg /Cum. The wall panels will be provided with tongue and groove joint for interlocking. One edge shall have double groove system for better insulation. All the flashings provided shall be made out of 0.50 mm thickness PPGI sheet. The interior and exterior colour of panels shall be RAL 9003 colour. The PUF insulation material in the panel will have fire retarding and self-extinguishing properties. The Puf Panels shall be manufactured using high pressure dispensing machine equipped with PLC Controlled panel for monitoring and controlling the injection rate to assure specified uniform density requirements. Make of the Panels shall be BNAL/Sintex/Alfa. | 433 | sqm | 4,980 ₹21,56,340 | 3,591 ₹15,54,903 Lowest |
| 2.00 | Supply and Installation of 75 mm thick Extruded Polystyrene (XPS) with the following specifications: The 75 mm thick extruded polystyrene rigid insulation board of required size shall be provided in the flooring, complying with ISO 4898:2008 & ASTM C 578- 08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621,density of 34-36 kg/m³ as per ASTM D 1622, water absorptions 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576.Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, complete in all respect as per the direction of Engineer-in-Charge. Makes of the Extruded Polystyrene (XPS) shall be Technonicol/Owen/Texsa. | 133 | sqm | 3,995 ₹5,31,335 | 1,787 ₹2,37,671 Lowest |
| 3.00 | Chiller door with 80mm thick leaf having both side PPGI sheet with heavy duty Aluminium Frame, hinges and locking device and gaskets size 900 x 2100mm clear opening. | 4 | units | 74,300 ₹2,97,200 | 54,940 ₹2,19,760 Lowest |
| 4.00 | Supply and Installation of Refrigeration machines 3 Ton 3 Phase. Supply and Installation of heating system 4Kw(2+2). Specification :-
1 External Room Dimensions (LXWXH) in 7 m 4.68 m 4 m (Meter)
2 Product to be stored Banana
3 Product in coming temp. +30 Deg C.
4 In coming product quantity 15 Mt per day 5 Room Temperature Reqd. +14 to +17 Deg C
6 Ambient Temp +43 Deg C
7 Pull Down Time 3 to 5 days.
8 Other load Light
9 Heat Load- BTUH 20000 BTUH
10 Wall & Ceiling Panels Insulation 80 mm thick
11 Floor Panel Insulation 50 mm Bare Puff Slab
12 Internal and front side is PP
13 Outside is PPGI
14 Door Thickness and finish 80 mm PP/PP Condensing Unit
15 Copper pipe length 20 Feet each machine
16 Cooling Capacity Kw 7.8 Kw 3 Ph
17 Compressor make Emerson
18 Ref. Gas R-404a
19 No. of condensing unit 8 Nos. Indoor Unit
20 Heating Capacity Kw 4 KW(2+2)
21 Cooling Capacity Kw7.8 Kw 3 Ph
22 Digital Temp. Indicator cum controller | 8 | unit | 4,45,000 ₹35,60,000 | 3,35,845 ₹26,86,760 Lowest |
| 5.00 | ETHYLENE GAS SENSOR
TYPE Digital (Wall Mounted)
RANGE 0 - 2000 ppm
POWER SUPPLY 15-24 v DC | 4 | unit | 1,55,300 ₹6,21,200 | 55,268 ₹2,21,072 Lowest |
| 6.00 | CO2 GAS TRANSMITTER
TYPE Infrared, Digital (Wall Mounted)
MEASURING RANGE 0 – 5%
POWER SUPPLY 15 – 24 v DC | 4 | unit | 1,24,900 ₹4,99,600 | 77,080 ₹3,08,320 Lowest |
| 7.00 | AIR CIRCULATION WITH CONTROLLER 1 SET (per room) TYPE Wall Mounted
FEATURES Fans for exhaust & fresh air
Controls for 2 Gas Sensors
POWER SUPPLY 220V, 50 Hz
PROTECTION IP 31 | 4 | unit | 88,500 ₹3,54,000 | 35,260 ₹1,41,040 Lowest |
| 8.00 | HUMIDIFIER
TYPE Wall Mounted
DISPENSING UNIT Nozzles
INLET WATER PRESSURE 4 Bar minimum
POWER SUPPLY 230 VAC, 3 Amp | 4 | unit | 75,600 ₹3,02,400 | 72,160 ₹2,88,640 Lowest |
| 9.00 | ETHYLENE GENERATOR Portable
MODEL GENET
POWER SUPPLY 230V, 50 Hz 400W
TANK CAPACITY 1 Liter
DIMENSIONS 315 X 250 X 350 mm
SUPPLIED WITH Genetol Ripening Liquid | 1 | unit | 2,06,000 ₹2,06,000 | 1,45,140 ₹1,45,140 Lowest |
| 10.00 | AFFF Based 9 kg Mechanical Foam Portable Fire Extinguisher. | 8 | unit | 7,900 ₹63,200 | 4,879 ₹39,032 Lowest |
Tender Value
Refer Docs
EMD Value
₹2.5 L
Closing Date
4 Jun 2022, 4:00 pmClosed
Managing Director, JK AIDCL
JK Agro Industries Corporation Ltd, Gole Pully, Talab Tillo, Jammu
Construction of Ripening Store for Banana and other Fruits at Cold Store, Lal Mandi, Srinagar
2022_MD_168164_1
Enit no. 07 of 2022-23
Open Tender
Civil Works
Fixed-rate
120 days
Construction of Ripening Store for Banana and othe
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
Official Acc of JK AIDCL
₹2.5 L
17 Jun 2022
30 Apr 2022
6 Jun 2022
30 Apr 2022
4 Jun 2022
30 Apr 2022
30 Apr 2022 - 4 Jun 2022
Amount
Supply and Installation of Walls and Ceilings with Puf Panels 80 mm thick with the following specifications: Walls and ceiling shall be made up of 80 mm thick Puf Insulated Panels. The main columns will be made out of R H Steel section of size 122x61x3.60 mm conforming to IS 4923: 1997 to provide maximum strength. MS Base plate of size 250x250x8mm and top plate of size 200x150x8 mm will be welded to the columns. Base plates will be pre drilled with 4 Nos 18 mm dia holes and provided with anchor bolts at the bottom and normal bolts at the top of 16 mm dia. The Puf Panels shall be 80 mm thick with 0.5 mm thick PPGI Sheets on both sides. The Panels shall be manufactured on continuous automatic line with puf density 40 + 2 Kg /Cum. The wall panels will be provided with tongue and groove joint for interlocking. One edge shall have double groove system for better insulation. All the flashings provided shall be made out of 0.50 mm thickness PPGI sheet. The interior and exterior colour of panels shall be RAL 9003 colour. The PUF insulation material in the panel will have fire retarding and self-extinguishing properties. The Puf Panels shall be manufactured using high pressure dispensing machine equipped with PLC Controlled panel for monitoring and controlling the injection rate to assure specified uniform density requirements. Make of the Panels shall be BNAL/Sintex/Alfa.
Supply and Installation of 75 mm thick Extruded Polystyrene (XPS) with the following specifications: The 75 mm thick extruded polystyrene rigid insulation board of required size shall be provided in the flooring, complying with ISO 4898:2008 & ASTM C 578- 08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of > 350 kPa listed as per ASTM D 1621,density of 34-36 kg/m³ as per ASTM D 1622, water absorptions 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576.Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, complete in all respect as per the direction of Engineer-in-Charge. Makes of the Extruded Polystyrene (XPS) shall be Technonicol/Owen/Texsa.
Chiller door with 80mm thick leaf having both side PPGI sheet with heavy duty Aluminium Frame, hinges and locking device and gaskets size 900 x 2100mm clear opening.
Supply and Installation of Refrigeration machines 3 Ton 3 Phase. Supply and Installation of heating system 4Kw(2+2). Specification :- 1 External Room Dimensions (LXWXH) in 7 m 4.68 m 4 m (Meter) 2 Product to be stored Banana 3 Product in coming temp. +30 Deg C. 4 In coming product quantity 15 Mt per day 5 Room Temperature Reqd. +14 to +17 Deg C 6 Ambient Temp +43 Deg C 7 Pull Down Time 3 to 5 days. 8 Other load Light 9 Heat Load- BTUH 20000 BTUH 10 Wall & Ceiling Panels Insulation 80 mm thick 11 Floor Panel Insulation 50 mm Bare Puff Slab 12 Internal and front side is PP 13 Outside is PPGI 14 Door Thickness and finish 80 mm PP/PP Condensing Unit 15 Copper pipe length 20 Feet each machine 16 Cooling Capacity Kw 7.8 Kw 3 Ph 17 Compressor make Emerson 18 Ref. Gas R-404a 19 No. of condensing unit 8 Nos. Indoor Unit 20 Heating Capacity Kw 4 KW(2+2) 21 Cooling Capacity Kw7.8 Kw 3 Ph 22 Digital Temp. Indicator cum controller
ETHYLENE GAS SENSOR TYPE Digital (Wall Mounted) RANGE 0 - 2000 ppm POWER SUPPLY 15-24 v DC
CO2 GAS TRANSMITTER TYPE Infrared, Digital (Wall Mounted) MEASURING RANGE 0 – 5% POWER SUPPLY 15 – 24 v DC
AIR CIRCULATION WITH CONTROLLER 1 SET (per room) TYPE Wall Mounted FEATURES Fans for exhaust & fresh air Controls for 2 Gas Sensors POWER SUPPLY 220V, 50 Hz PROTECTION IP 31
HUMIDIFIER TYPE Wall Mounted DISPENSING UNIT Nozzles INLET WATER PRESSURE 4 Bar minimum POWER SUPPLY 230 VAC, 3 Amp
ETHYLENE GENERATOR Portable MODEL GENET POWER SUPPLY 230V, 50 Hz 400W TANK CAPACITY 1 Liter DIMENSIONS 315 X 250 X 350 mm SUPPLIED WITH Genetol Ripening Liquid
AFFF Based 9 kg Mechanical Foam Portable Fire Extinguisher.
M.S. Heavy Duty Platform Trolley. Loading Capacity – 500-800 Kgs.
Electronic weightscale. Measuring capacity of 200Kgs
Earth work Earth work earth work in excavation by manual means in formation trenches (not exceeding 1.5m in width as well as 10sqm on plan) including dressing of sides and ramming of bottoms lift upto 1.5m including getting out of excavated soil as direced upto 50 mtr for all kind of soils(manually)
Filling available excated earth (excluding rock) in trenches plinths sides of foundation extra in layers not exceeding 20 cm in depth, consolidate each deposited layer by ramming and watering, lead upto 50 mtr and lift upto 1.5 mtr.
supplying and stacking at site good earth.Distance upto 5 km
supplying and filling in plinth with fine sand under floors including watering, ramming, consoildating and dressing complete.
Cement Concrete work providing and laying in postion cement concrete of specified grade including curing but excluding cost of centering and shuttering all work upto plinth level (a) 1:4:8 ( 1 cement :4 coarse sand :8 graded stone crushed aggregate 40mm normal size).
Cement Concrete work providing and laying in postion cement concrete of specified grade including curing but excluding cost of centering and shuttering all work upto plinth level (b) 1:3:6 (1 cement: 3 coarse sand :6 graded stone crushed aggregate 20mm normal size).
Reinforced Cement Concrete reinforced cement concrete work in beams and slats having slop unto floor level -5 including curing but excluding cost of centering, shuttering, finishing and reinforcement. (a) in 1:2:4 (1 cement : 2 cement :4 graded stone crushed aggregate of 20 mm normal size in plinth beam).
Reinforced Cement Concrete reinforced cement concrete work in beams and slats having slop unto floor level -5 including curing but excluding cost of centering, shuttering, finishing and reinforcement. (b) in 1:1.5:3 (1 cement: 1.5 cement: 3 graded stone crushed aggregate 20 mm normal size in slab.
Brick work Brick work with come burnt clay (non modular) bricks of class designation 7.5 in super structure including curing in 1:4 (1 cement: 4 coarse sand) cement sand mortar.
Form Work Centering and shuttering including strutting propping etc and removal of form for (a) foundations footing, etc
Form Work Centering and shuttering including strutting propping etc and removal of form for (b) Suspended floors, roofs, slabs, etc(above plinth level) upto floor.
Steel Reinforcement Steel reinforcment for RCC work including straightening, cutting binding placing in position and binding all complete upto plinth level and above with thermomechanically treated bars of grade Fe-500 D or more
Cement Plaster Providing and laying (a) 12mm cement plaster finished with a floating coat of meat cement in 1:4 (1 cement: 4 fine sand) cement mortar.
Cement Plaster (b) provind and laying cement plastrer of 15 mm thickness finshed with a floating coat of neat cement in 1:4 (1 cement :4 fine sand) mortar.
Flooring (a) providing and laying cement concrete flooring in 1:5:10 (1 cement: 5 coarse sand :10 graded stone crushed aggregate of 40mm normal size) including consolidation and level all complete. Note:- Thickness upto 6" = 0.15cm
Flooring (b) providing and laying 62mm thick cement concrete flooring with concrete hardener, topping under layer 50mm thick cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone crushed aggreagate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2(1 cement hardener:2 graded stone aggreagate 6mm normal size). Hardening compound mixed @ 2ltr per 50Kg of cement including cost of cement slurry and curing complete
cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggreate) finshed with a floating coat of neat cement including cement slurry and curing complete of 50mm thick with 20 mm nominal size stone aggregate
Truss:- mono roof truss using ISA(indian standard angles) equal leg angles of size 50mmx50mmx6mm . Structure steel work in built up section of truss including cutting hoisting fixing in position and applying a priming coat of approved steel primer with welding of joints.
Providing corrugated G.I sheets roofing including vertical/curved surface fixed with polymer coated 'J' or 'L' hooks, bolts and nuts 8 mm diameter with bitomen and GI Limpet washers or with GI limpet washers filled with white lead, including a coat of approved steel promer and two coats of approved paint on overlapping of sheets complete excluding the cost of purlins rafters and trusses and including cutting to size and shape wherever required. 0.8mm thickwith zinc coating not less than 275gram/msq CGI sheets.
construction of Road of dimensions 50m x 4m.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supplying & Fixing Of Following Sizes Of PVC Conduit Along With Accessories in Surface Including Cutting the Wall And Making Good the same In Case of recess Conduit as Required 20mm.
Wiring for light/ power plug with 2 X 4 sq. mm + 1 X 4 sq. mm earth wireFRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing following Wall Mounted switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following Wall Mounted switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
Supplying and fixing following Wall Mounted switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following Wall Mounted switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required 6 Module (200mmX75mm)
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without 6way (4 +18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. MCB & DB Shall Be Of Same Make Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. MCB & DB Shall Be Of Same Make Double pole
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
25 mm Total of the Sub-Head - Mccb, Mcb & Ob's :
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/cable as required.
Supply and commissioning Of LT Power Cable 1.1 Kv Grade , 900C rating, heavy duty, XLPE Power cable conforming to following requirement and in line with IS-1554, IS-5831, IS-8130,& IS-3975, XLPE Insulated , Pvc Inner Sheathed (Extruded ) Armoured , FRLS Pvc Outer Sheathed , Stranded Aluminium Conductor Confirming To IS : 7098 Part 1, Armour: galvanised steel strip/ wire as per applicable. Aluminium Armoured Cable size: 3.5 Core x 35 sqmm
Sub-Head : MV Cable Laying From AMF Panel To Main. Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.l. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
MV CABLE JOINTING & END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Suppy & Fixing Of Fixtures 30W LED Light Fixture Surface Mounted 2’x 2 ‘
Supply of the following light fixtures complete with housing, reflectors, complete with all accessories i.e. driver, lamp, holders etc. complete as required. 15W LED Wall Light Fixture.
M/S GLOBAL ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .