Loading…
Loading…
Tender ID
| # | Company | Amount |
|---|---|---|
| 1 | ₹30.3 L |
Tender Value
₹44.0 L
EMD Value
₹88,000
Closing Date
2 Mar 2026, 3:00 pmClosed
LALIT KUMAR
CHIEF ENGINEER
Siksha Bhawan, Rastrabhasha Parishad, Saidpur, Patna-800004
LALIT KUMAR
CHIEF ENGINEER
RENOVATION/REPAIRING WORK OF EXISTING BUILDING AT TOWN +2 SCHOOL , ARA
125948
NIT-46/2025-26/19
Open Tender
CIVIL
Patna
• Name of the Contractor
• Postal Address of the Contractor
• Contact No. of the Contractor
• Email id of the Contractor
• GST
• PAN
• Bids shall remain valid for a period not less than 120 days after the deadline date.
• BID SECURITY-Online/ Bank Guarantee 0.88 Lac
• Work Exp - Satisfactory completed 1 Similar work (Building Construction) not less than of Rs. 22.00 Lac in last 5 fin yr
• Registration Details
• Information regarding any litigation during the last five years, in which the Bidder is involved
• Affidavit
• Valid Character certificate (TO BE ISSUED BY SUPRITENDENT OF POLICE OR HIGHER DESIGNATED OFFICER)
CIVIL
PERCENTAGE
L1
1
23 documents required · 23 mandatory
₹5,000
Processing Fee: 590
₹88,000
CE OFFICE BSEIDC PATNA
6 Apr 2026
23 Feb 2026
6 Mar 2026
23 Feb 2026
2 Mar 2026
23 Feb 2026
27 Feb 2026
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
Providing and laying Vitrified tiles in floor in different sizes {thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only.Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness,leveling system and rubber mallet for placing the tiles gently and easily.
4 mm thick ACP
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.6 A to 32 A, double pole
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as Upto 450 mm sweep
1.5 Tr. 5 Star Split A.C (Inverter Types ) IS -1391
Providing and fixing Drain Pipe for A.C
Copper Tube of size 1/2" for split ac unit 1/1.5/2/3 tr capacity including nitride rubber insulation
Estimate for 100 mm X 90 M deep Boring with 1 HP Submersible motor and Running water facility with Hand Wash Station
S.O.R Code
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge.
Providing and fixing brass bib cock of approved quality :
Earth work in excavation in foundation trenches (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Providing PCC 1:3:6 (1 Cement; 3 coarse sand :6 graded stone aggregate 40 mm nominal size) in foundation excluding the cost of centring and shuttering-all work upto plinth level
Providing Brick work with bricks of class designation 100A in Cement mortar 1:4 (1 cement: 4 coarse sand ) in foundations and plinth .
Providing 125 mm thick brick masonry with bricks of class designation 100A in wall in Cement mortar 1:4 (1 cement: 4 coarse sand).
Providing Reinforced cement concrete work in 1:1.5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size in Cover Slab excluding cost of centring, shuttering, finishing and reinforcement.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
Providing 12 mm cement plaster of mix 1:3 (1 cement: 3 coarse sand) with 5 % Water proofing materials and neat cement punning
Providing 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) in walls
Chequerred precast cement concrete tiles 22 mm thick with marble chips of size 6 mm in plateform jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. Complete on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand)
Detailed Estimate For Construction of Toilet Complex ( 3 unit toilet & 3 unit (wc) With Two urinal
SOR Ref No.
Making 25 cm (10") dia bore up to 4 mtr depth below ground with hand auger of approved quality in ordinary soi! (vide classification of soil item A ) true to plumb and without eccentri city in any stage of operation and disposal of the excavated earth up to 50 mtr , Lead in eluding all lifts , all complete as per approved disign and direction of E/l Details of cost for 4 piles of 4 m= 16 mtrs depth )
Brick work with bricks of class designation 100A in foundations and plinth in: Cement mortar 1.:4(1cement: 4 coarse sand)
Half brick masonry with bricks of class designation100A in foundations and plinth in: Cement mortar 1:4 (1cement: 4 coarse send)
Brick work with bricks of class designation 100A in foundations and plinth in: Cement mortar 1.:6(1cement: 6 coarse sand) + Extra for Brick work in superstructure above plinth level upto floor V cum
6 mm cement plaster to ceiling of mix : 1:4(1 cement: 4 coarse sand) + Neat cement punning + White washing with lime to give an ever shade New work (three or more coats)
12 mm cement plaster of mix: 1:6(1 cement: 6 coarse sand) + Neat cement punning
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Applying one coat of cement primer of approved brand and manufacture on wall surface: Cement primer + Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade New work (three or more coats)
SOR Ref No.
S.O.R No
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with piano type switch, phenolic laminated sheet, suitable size M.S./PVC box etc as reouired. Group'C'
CIVIL WORKS ( REPAIR + ELECTRIC ) AT HOSTEL AND DINING
S.O.R Code
Brick work with bricks of class designation 100A in Cement mortar 1:4 (1 cement: 4 coarse sand ) in Superstructure all complete
Reinforced cement concrete work in 1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20mm nominal size) roof and beam. upto floor five level excluding cost of centring, shuttering all complete.
Providing Reinforcement in RCC work
Distempering in interior walls with dry distemper of approved brand and manufacture (two or more coats ) and of required shade on new work , over one coat of distemper primer of approved brand and manufacture on wall surface:and including to give an even shade.
Providing two or more coats (snowcem) in exteior wall with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings complete including applying a priming coat of approved steel primer
Providing and fixing M.S. grills Fixed to steel windows by welding of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Providing two enamel paint on steel over a coat of with ready mixed paint of approved brand and manufacture in all shades to give an even shade all complete
Providing Electric Work
Amount (In Rs.)
Time of Completion- 2 Months
S.O.R Code
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
Providing and laying Vitrified tiles in floor in different sizes {thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only.Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness,leveling system and rubber mallet for placing the tiles gently and easily.
4 mm thick ACP
Providing Brick work with bricks of class designation 100A in Cement mortar 1:4 (1 cement: 4 coarse sand ) in foundations and plinth .
Providing 125 mm thick brick masonry with bricks of class designation 100A in wall in Cement mortar 1:4 (1 cement: 4 coarse sand).
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
Providing 12 mm cement plaster of mix 1:3 (1 cement: 3 coarse sand) with 5 % Water proofing materials and neat cement punning
Making 25 cm (10") dia bore up to 4 mtr depth below ground with hand auger of approved quality in ordinary soi! (vide classification of soil item A ) true to plumb and without eccentri city in any stage of operation and disposal of the excavated earth up to 50 mtr , Lead in eluding all lifts , all complete as per approved disign and direction of E/l Details of cost for 4 piles of 4 m= 16 mtrs depth )
Brick work with bricks of class designation 100A in foundations and plinth in: Cement mortar 1.:4(1cement: 4 coarse sand)
Half brick masonry with bricks of class designation100A in foundations and plinth in: Cement mortar 1:4 (1cement: 4 coarse send)
Brick work with bricks of class designation 100A in foundations and plinth in: Cement mortar 1.:6(1cement: 6 coarse sand) + Extra for Brick work in superstructure above plinth level upto floor V cum
6 mm cement plaster to ceiling of mix : 1:4(1 cement: 4 coarse sand) + Neat cement punning + White washing with lime to give an ever shade New work (three or more coats)
12 mm cement plaster of mix: 1:6(1 cement: 6 coarse sand) + Neat cement punning
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Applying one coat of cement primer of approved brand and manufacture on wall surface: Cement primer + Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade New work (three or more coats)
Brick work with bricks of class designation 100A in Cement mortar 1:4 (1 cement: 4 coarse sand ) in Superstructure all complete
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars TMTC-500-8mm dia.
Distempering in interior walls with dry distemper of approved brand and manufacture (two or more coats ) and of required shade on new work , over one coat of distemper primer of approved brand and manufacture on wall surface:and including to give an even shade.
Providing two or more coats (snowcem) in exteior wall with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade
Supplying, Installing, Testing, Commissioning of 1.5 T inverter AC including appropriate stabilizer complete setup of Make- (Daikin/Carrier/Hitachi/Voltas) all complete job as per direction of E/I.
Supplying, Installation, Testing & Commissioning of Refregent pipe 5/8 and ¼ copper tube with nytral rubber tube insulated including 3 core 2.5 sqmm copper wire all complete job as per direction of E/I.
4KVA Wall mounted automatic voltage stabilizer with hi/low cut off timer of make V-Guard do do all complete job as per direction of E/I.
Supplying & fitting of Drain with PVC rigid including required fitting and support all complete job as per direction of E/I.
Supplying & fitting of powder coated iron structure for placement of outdoor unit all complete job as per direction of E/I.
aoc.json
Purchase Order
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT-No.-46_2024-25.pdf
NIT • 0.26 MB
NIT-No.-46_2024-25.pdf
NIT • 0.26 MB
NIT-46 (2025-26) - CORRIGENDUM No.-1.pdf
NIT • 0.40 MB
SpeCon2025NIT46SL19.doc
NIT • 0.05 MB
BOQ-NIT46SR19.xls
NIT • 0.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .