Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 LAccepted-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹41.0 L+₹2.1 L (5.32%)Rejected-AOC 26 3 BOMBAY PUNE ROAD LAXMI APARTMENT OPP BU BHANDARI SHOWROOM PUNE 411003 | PUNE | MAHARASHTRA | 411003 | L2 | Rejected-AOC Being L2 | |
| 3 | L3₹49.3 L+₹10.4 L (26.7%)Rejected-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L3 | Rejected-AOC Being L3 | |
| 4 | L4₹49.5 L+₹10.5 L (27.0%)Rejected-AOC | L4 | Rejected-AOC Being L4 | |
| 5 | L5₹49.8 L+₹10.8 L (27.9%)Rejected-AOC FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L5 | Rejected-AOC Being L5 |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
10 May 2025, 6:00 pmClosed
GE RnD Pashan
GE RnD Pashan
REPAIR OF LEAKAGE/SEEPAGE PROBLEMS AT VARIOUS BUILDINGS OF ARDE, PASHAN PUNE
2025_MES_704298_1
GERD/PSN/TOKEN/75 OF 2024-2025
Open Tender
Civil Works
Item Rate
180 days
GE RnD Pashan
As per tender documents
9 documents required · 9 mandatory
₹500
GE RnD Pashan
₹96,000
Yes
3 Jun 2025
12 Apr 2025
12 May 2025
12 Apr 2025
10 May 2025
26 Apr 2025
12 Apr 2025 - 19 Apr 2025
Amount
Demolishing of cement concrete (unreinforced) in roof/floors other than ground level beam, stair case, landing, chajjas and similar items including water proofing treatment in any layers and removal of debris to distance exceeding 250m and not exceeding 500m from the site complete all as specified and directed by Engr-in-Charge.
Material and labour for Cutting cracks to V section in existing roof or terrace, cleaning out and filling solidy with a coat of approved Crack Filler complete all as per manufacturers instructions and all as specified and directed by Engr-in-Charge. Make : Dr Fixit Crack X Shrinkfree or Smart care Crack seal
Material and labour for 40mm thick PCC 1:2:4 type B0 (using 12.50mm graded stone aggregate) as in levelling course to match the undulations of roof and in covering etc complete all as specified and directed. Note : Rate quoted is deemed include for scaffolding cost at any height.
Material and labour for rendering 10 mm thick on concrete surface in cement mortar 1:3 for receive the roof finishes with water proofing liquid. (WPL Shall be measured and paid separately) complete all as specified and directed.
M&L for applying water based polyurethane modified dispersion (single component, cold applied, non toxic, VOC complaint) in 03 coats including 01 coat of epoxy primer @ 0.15 Kg per Sqm followed by two coats of polyurethane coating with 1.5 Kg per sqm in two coats etc complete per manufacturer specification and all as specified and as directed by Garrison Engineer/Engr-in-Charge. Notes : 1. Properties of Polyurethane based chemical shall confirm to following Technical Parameters:- (i) Highly Elastic and shall have crack bridging ability of upto 3mm as per AS NZ 4548 (ii) UV Resistance. (iii) Adhesion to concrete and shall resist 7 bars of hydrostatic pressure. (iv) Tensile strength should not less than 2.0 N/sq.mm for free film & 60 % solid content as per ASTM C 1250 (v) Elongation should not less than 300% as per ASTM D2370 (vi) Solid content by weight should not less than 60%. (vii) Air/water permeability BSEN 12390 AT 5 bar -72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.0mm. (viii) Accelerated weathering (ASTM453) should Pass 1000 hours. (ix) Reaction to fire – non inflammable. 2. The work shall be executed thru auth applicator of manufecturer only. Contarctor has to provide manufecturer test certificates for the above mentioned technical parameters and PVs. 3. The conractor has to submit the guarntee for 10 Years against the water proofing treatment. Make:- Bostic, Berger,Fosroc, sika, Asian.
Disconnecting existing tanks of capacity exc 250Ltrs and n exc 500Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in position complete all as specified and directed.
Disconnecting existing tanks of capacity exc 500Ltrs and n exc 1000Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in position complete all as specified and directed.
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 19-20mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement mortar in the ratio of 1:4 and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls if required in the same manner complete all as specified and directed by Engr-in-Charge.
Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed by Engr-in-Charge
Material and labour for IInd class hard wood battens in roofs at any height, including making good the holes in wall and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to the dumping ground, necessary scaffolfing all complete as per direction of Engineer-in-Charge
Providing and fixing on roof pressed clay tile (Mangalore tile) at any height of 20 mm nominal thickness and of approved size and as per approved pattern including necessary scaffolfing complete all as specified and directed by Engr-in-Charge
Providing and laying on roof pressed clay tile (Mangalore tile) of 20mm thickness on ridge, hips, valley gutter, sloped roof etc complete all as specified and directed by Engr-in-Charge.
Dismantling GI sheet in roofing including ridges, hips, valleygutter etc. and stacking the material within 50 Metres. complete all as specified and directed.
Supply and fix 1.00 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings at any height including necessary scaffolding (length and girth as fixed) with grade of zinc coating 275 complete all as specified and dircted.
Supply and fix mild steel bands, straps, support or stays for rain water pipe, hold fast, clamp and similar small articles etc conforming to Fe-290 Gde-E-165 complete all as specified and directed.
cleaning of any type of roof area not exceeding 100 Sqm by removing leaves, vegetation growth, debris and accumulated mud by washing brushing or by any means without hampering the water proofing membrane(if provided) from permanent roof not accessible including cleaning of rain water pipes of any description and removing debries/spoil from site and depositing the same to low lying area exceeding 0.5 km and not exceeding 1.5km, Complete all as specified and directed by Engineer-in-Charge.
All as per item No 16 here in above but area of roof exceeding 100Sqm but not exceeding 300 Sqm, Complete all as specified and directed by Engineer-in-Charge.
All as per item No 16 here in above but area of roof exceeding 300Sqm but not exceeding 500 Sqm, Complete all as specified and directed by Engineer-in-Charge.
All as per item No 16 here in above but area of roof exceeding 500Sqm Complete all as specified and directed by Engineer-in-Charge.
Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level complete all as specified and directed by Engineer-in-charge.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank complete all as specified and directed.
Dismantling roofing asbestos cement sheet including ridges, hips, valleygutters etc at any height including stacking the material within 50 Metres lead complete all as specified and directed.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5 to 7 microns epoxy primer on both side of the sheet and polyester top coat 15 to 18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required complete all as specified and directed.
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets, sunken floor etc., up to floor five level, including the cost of centering, shuttering and finishing 1:1 1/2:3 type B0 (using 12.5 mm graded stone agregate) nominal size complete all as specified and directed.
Material and Labour for providing and laying water proofing treatment to sunken floor portion of water closet ,Bathroom etc,by applying first layer of slurry of cement @0.488 kg/Sqm mixed with Dr fixit or Equivalent Acrylic based polymer modified cementitious (PMC) composite [email protected]/sqm this layer will be allowed to air cure for four hours and second layer of slurry of cement 0.242 kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @0.126kg /sqm this layer will be allowed to air cure for four hours followed with water curing (ponding) for 48 hours complete all as specified and directed. Note : The rate includes the preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and brick work/masonary work with polymer mixed slurry.
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation complete all as specified and directed.
Material and Labour for Cutting/Chipping of the spalled,unsound concrete of slabs,beams,columns ,fins,facia,parapets&chajjas etc, and damaged /distressed plaster by scapping with utmost care to expose reinforcement ,cleaning the rusted reinforcement by rubbing wire brushes or emery paper & cleaning the surfaces of any thickness to receive guniting/plastering and disposal of debris not excedding 500mtrs complete all as specified and directed
Supply and fix Hard drawn steel wire fabric weight n. exc 4Kg per sqm cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia, complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for preparing surfaces and applying a coat of Nito Bond AR of M/S Fosroc chemicals or equivalent approved bonding agent as per manufacturers instructions and applying pressure guiniting averaging 25mm at a pressure of not less than 6kg/sqm in cement mortor 1:3 with and including suitable bonding agent of M/S sika or equivalent @5% of weight of cement as per manufacturer instruction and finishing surfaces rough conforming to proper geometrices including providing double scaffolding and safety measures complete all as specified and directed.
Material and labour for Complete removal of existing treatment Cutting out cracks to V-section in existing plastered walls, cleaning out, wetting, grouting with suitable crack filling agent like Dr. Fixit Crack X or Dr Fixit Crack X Shrink Free or Dr Fixit Pidicrete URP with respect to the width of crack complete all as per manufacturers instruction complete all as specified and directed.
Dismantling old plaster or raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed by Engr-in-Charge
Material and Labour for rendering 12 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth complete all as specified and directed.
Material and labour for 6 mm cement plaster 1:3 finished even and smooth with floating coat of neat cement on RCC slab, beam and ceiling complete all as specified and directed.
Material and Labour for 18 mm thick rendering in two coats under layer 12 mm thick cement mortar 1:6 finished with a top layer 6 mm thick cement plaster 1:4 using water proofing compound as per manufacturer instuctions (WPC shall be measured and paid separately) complete all as specified and directed.
Supply only Liquid waterproofing compound complete all as specified and directed.
Material and labour for Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on new work (two coats) over and including water thinnable priming coat with cement primer on new plastered surface of wall complete all as specified and directed.
All as per item No 36 above but on new plastered surfaces on ceiling complete all as specified and directed by Engr-in-Charge
Material and labour for preperation of new surfaces and Finishing walls with Acrylic Smooth exterior emulsion paint of required shade : New work (Two coat applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete all as specified and directed.
Material and labour for Distempering on old work two coats with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade. Complete all as specified and directed.
Material and labour for damp proof waterproofing treatment on external walls as per following procedure on old plastered surface or newly plastered surface complete all as specified and directed. (a) . Pre Painting Steps Surface should be prepared free from any loose paint, dust or grease. Growth of Fungus, Algae or moss should be removed by wire brushing and water. If the Underlying surface exhibits chalkiness, in spite of surface cleaning then use Asian Paints Smartcare Primero. For filling cracks up to 3mm using Asian Paints Crack Seal.* In case of dents and holes use Asian Paints Trucare wall putty suprema. (b). Paint Applicaton Process 1 Coat of Smartcare Damproof (Undiluted)*1 st Coat of Apex Ultima Suprema (40% Dilution)*2nd Coat of Apex Ultima Suprema (40% Dilution) Complete all as specified as per manufacturer's instruction and Complete all as specified and directed.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area 3 sq. metres and below complete all as specified and directed.
Providing and fixing aluminium work for frames of doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be Powder coated (minimum thickness of powder coating 50 micron) smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and complete all as specified and directed by Engineer-in-charge.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) ventilators and partitions complete all as specified and directed by Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) with EPDM rubber / neoprene gasket etc. complete as per the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)
Supply and Fix Rough cast wired glass, 6.4mm thick of area exc 0.75 Sqm and n. exc 1.00 Sqm and glazing clip with oil putty at any height including necessary arrangement complete all as specified and directed.
Supply and fixing stainless steel wire guage (grade-304) aperture 1.4mm and 0.50mm dia wire for fixing of window, ventilator etc complete all as specified and directed by Engr-in-Charge
Providing & Fixing of Armstrong Mineral Fibre Acoustical Ceiling System with SIERRA OP (Bevelled Tegular) Edge Tiles With Armstrong 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.6, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 16mm , suitable for Green Building application, with Recycled content of 31%. The tile shall be laid on Armstrong Suprafine 32 with 15 mm face exposed grid colour white having rotery stitching on all silhoutte type T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 7.5 Kgs/M2 & minimum pull out strength of 100 Kgs. The T Sections have a Galvanizing of 90 grams per Sqm and need to be installed with Suspension system and necessarey aluminium angle of Armstrong make, including taking down old ceiling etc complete all as specified and directed.
Supply and fixing in repairs ceiling tiles fine fissured (Bevelled Tegular) Edge Tiles of size 600 x 600 x 16mm suitable for Green building application with recycled content of 31% etc and should have humidity resistance (RH) of 99%, NRC 0.6 Light reflectance ≥85%, Thermal Conductivity k=0.052 - 0.052 w/m K, Colour White, Fire Performace UK class 0/class 1 (BS 476 pt - 6&7) of make Armstrong or equivalent complete all as specified and directed by Engr-in-Charge.
Supply and fix Armstrong Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) Edge Tiles with Armstrong 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ≥85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 16mm , suitable for Green Building application, with Recycled content of 31%. The tile shall be laid on Armstrong Suprafine 32 with 15 mm face exposed grid colour white having rotary stitching on all silhouette type T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 7.5Kgs/Sqm with a minimum pull out strength of 100 kgs. The T Sections have a Galvanizing of 90 grams per Sqm and need to be installed with Suspension system of Armstrong make including taking down old ceiling etc complete all as specified and directed by Engr-in-charge.
Dismantling C.I. or asbestos rain water pipe 160mm dia at any height with fittings and clamps including necessary scaffolding if required and stacking the material within 50 metres lead complete all as specified and directed.
Supply and Fix 160 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls at any height including necessary scaffoling if required complete all as specified and directed.
Supply and fix PVC (SWR) bend any radius shoe, socket etc 160mm bore with access at any height including necessary scaffolding if required complete all as specified and directed.
Dismantling C.I. or asbestos rain water pipe 110mm dia at any height with fittings and clamps including including necessary scaffoling if required stacking the material within 50 metres lead complete all as specified and directed.
Providing and fixing 110 mm pipe on wall face unplasticised PVC rain water pipes single socketed conforming to IS : 13592 Type A including necessary scaffolding jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, complete all as specified and directed.
Providing and fixing 110 mm bend of 87.5 on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, complete all as specified and directed.
Dismantling C.I. or asbestos rain water pipe 75 to 80mm dia at any height with fittings and clamps including necessary scaffoling if required stacking the material within 50 metres lead complete all as specified and directed.
Providing and fix on wall face unplasticised Rigid PVC pipes of 75 mm dia single socketed conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion complete all as specified and directed.
Providing and fixing 75mm bend of 87.5 degree on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, complete all as specified and directed.
Dismantling G.I. pipes 15 mm to 40 mm nominal bore including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead complete all as specified and directed by Engineer-in-charge
Supply and Fix 15mm dia Tubes Medium grade galvanised with necessary fittings and fixed complete to wall and ceiling or laid in floor including cutting and making good to the walls complete all as specified and directed.
Providing and laying Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent flooring in required design and patterns, in linear as well as curvilinear portions of the building with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing, moulding and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead complete all as specified and directed by Engineer - in - charge.
Material and labour for plinth protection 50mm thick of cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) nominal size over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including expansion joint every 2m interval and necessary excavation, levelling & dressing & finishing the top smooth complete all as specified and directed.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. complete all as specified and directed.
Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in cement mortar 1:6 complete all as specified and directed.
Supply and fixing Venetian blinds with design on inner face, verticle type made of fiber cloth fixed to wall with necessary aluminium brackets, screws etc including Alluminium frame ropes, rollers etc as approved by GE and complete all as specified and directed.
Taking down / dismantling existing perished aluminium strip of size 25 x 3.15 mm from any height of roof top / on walls of conventional type lightening protection network system complete all as specifiec and as directed.
Re-fixing of serviceable aluminium strip of size 25 x 3.15 mm obtained from sl item No 68 above at any type of building/ magzine/ lab at any height on walls and jointing the system of conventional type lightening protection network and making good the disturbed surface of walls / roof top to match with existing surface complete all as specified and as directed.
Material and labour for new aluminium strip 25 x 3.15 mm awith saddles and fixing screws etc for roof conductors and down conductors as earthing continuity conductor as on wall/roof complete all as specified and directed.
Supply and fixing in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw inclduinf dismantling/taking down old inspection box complete all as specified and directed by Engr-in-Charge.
Supply and fix new air termination single pointed aluminium rod of 12 mm dia 300 mm long fixed to aluminium strip 25 x 3 mm including drilling holes, nuts, bolts washers for resting/ supporting of air terminals etc., complete all as specified and directed.
Material and labour for PCC block of size 150 x 150 x 150mm of PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate including necessary form work / mould for fair and even surfaces, for fixing air termination rod / GI strip etc., complete all as specified and directed.
Supply only of epoxy base insulator of suitable size, 35mm height fixed on PCC blocks/ wall or MS angle/ Pipe or on traverse on GI sheet with and including bolt size 8mm dia, 19mm length, nuts and washers etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below normal ground level) with the top edges of plate not less than 1.5 mtrs below normal ground level, earth plate connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate connected to earth test point all as specified or indicated including testing on completion, including necesary excavation and earth work in any type of soil and edwquate quantity of common salt & charcol for alternate layer around the earth plate, including PCC 1:2:4 and 10mm thick CI cover with arrangement of hinge to 40x40x6mm CI angle iron frame, including 20m dia GI pipe for watering purpose with the arrangement of funel and wire mess, including GI pipe of 15mm dia for earth lead protection, complete all as specified and directed by Engr-in-Charge.
Providing and laying GI tape 32 x 6mm from earth electrode directly in fround as required complete all as specified and directed.
Supply and fix in repair Galvanished iron strip 32x6mm buried in ground complete all as specified and directed by Engr-in-Charge.
Supply and fixing mild steel with powder coated simens gray inspection boxes/test point boxes of size 250 x 200 x 100mm made out of 16 guage with top cover including provision of fixing of 2 Nos epoxy insulator with and including insulating PVC sheet for incoming and outgoing strip for proper insulation etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair old mild steel inspection boxes/test point boxes of any size/type with top cover including provision of fixing of 2 Nos epoxy insulator with and including drilling work, insulating PVC sheet for incoming and outgoing strip for proper insulation etc complete all as specified and directed by Engr-in-Charge.
Supply and fix earth pit indicator made out of MS sheet of 16 SWG of size 30x20cm welded to angle iron of size 25x25x3mm at a height 1M above ground including dismantling taking out old pit indicator complete all as specified and directed by Engr-in-Charge.
M/S NILESH BUILDERS (BID ID -3291135)
VIRENDRA FABRICATORS (BID ID -3290930)
T.H.ASSOCIATES (BID ID -3291008)
AJAY ENTERPRISES (BID ID -3290611)
Vipul Enterprises (BID ID -3291289)
Rays Breakers (BID ID -3290866)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .