Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical non responsive |
Tender Value
₹15.7 L
EMD Value
₹31,400
Closing Date
29 Jul 2020, 2:00 pmClosed
DGM Unit electric JKPCC Ltd Srinagar
DGM Unit electric JKPCC Ltd Srinagar
Internal Electrification of Indoor stadium at Rajpora, Pulwama
2020_PWDJK_100929_2
30/E/K of 2020-21 Dt. 20.07.2020
Open Tender
Electrical Works
Item Rate
90 days
Rajpora
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
FC JKPCC Ltd A/c
₹31,400
Yes
DGM Unit electric JKPCC Ltd Srinagar
7 Aug 2020
21 Jul 2020
30 Jul 2020
21 Jul 2020
29 Jul 2020
21 Jul 2020
25 Jul 2020
Amount
Wiring for light point / Fan point / Exhaust fan point / call bell poin with 1.5sqmm FRLS PVC insulated copper conductor single core cable in surface / Recesed medium class PVC conduit with modular switch,modular base/ Cover plate suitable G.I box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc as required. (excluding the cost of pvc conduit.)
Wiring for light plugs with 2 x 2.5 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 no 2.5 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as requierd.(excluding the cost of pvc conduit.)
Wiring for power plugs with 2x4qmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit along with 1no. Of 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(excluding the cost of pvc conduit.)
Wiring for circuits/submains alng with Earth wire with the following sizes of FRLS PVC insulated copper conductor single core cables in surface / recessed medium class PVC conduit as required. (excluding the cost of pvc conduit.)
2x2.5sqmm + 1 no.2.5sqmm pvc insulated copper conductor
2x6 sqmm + 1 no.6 sqmm pvc insulated copper conductor
2x10sqmm + 1 no.6 sqmm pvc insulated copper conductor
Supply and fixing of 3 pin 5/6 amp modular socket outlet with shutters and 5/6 amp modular type switch including connections and civil work exluding G.I box but including cover plates
Supply and fixing of 3 pin 15/16 amp modular socket outlet with shutters and 15/16 amp modular type switch including connections and civil work exluding G.I box but including cover plates
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar,neutral link, earth bar, din bar, detachable gland plate interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator)
Sheet metal enclosed 6way TPN DB double door complete with neutral link
Sheet metal enclosed 12way SPN DB double door complete with neutral link
Supply and fixing of 6-32Amp SP 240V " C " series miniature circuit breaker ( MCB) suitable for lighting and other loads in the existing MCB DB"s complete with connections,testing & commissioning ets as per technical specifications
Supply,installation,testing and commissioning of following rating Double pole MCB"s with breaking capacity of 10KA as per IEC 60947-2 and as per the satisfaction of Engineer incharge
Supply,installation,testing and commissioning of Ceiling fans/wall fan 5 star rating complete with double ball bearig, motorbearing, blades, down-rod canopies capacitor two module stepped type electronic fan regulator suitable for operation on 230V 50HZ 1-phase A.C supply complete as required
1200 mm sweep
Supply,installation,testing & commissioning of 900 RPM 300mm Exhaust Fan suitable for single phase 230v 50HZ AC supply Complete with motor louvers,shutters etc complete as required
Supply,Installation,testing and Commissioning of Cubical type L.T Panel board suitable for 415V 3phase 4wire 50HZ AC supply system including incomers,outgoings,bus-bar,interlocking etc,dust & vermin proof with lockable arrangement, powder coated INCOMERS MCCB 250 Amp 4 Pole with breaking capacity 36 KA 1N0 Digital multifunctional-meter 1 no Indicating Lamps ( RYB ) 1 set Current-Transformer ( 300/5A 10VA burden) class-1 1set Aluminium bus-bar 300 Amp FP E-91 Electrolutic AL 1sets.200A change over switch Panel Mount :1 No. Out-Goings MCCB 63 Amp TPN with Breaking capacity 10 KA 2Nos MCB 63 Amp DP with Breaking capacity 10 KA 8 Nos Load Bearing Member to be made out of 16SWG CRCA Sheet Partition to be made out of 16SWG CRCA Sheet Gland Plates to be made16 SWGmm thick Complete job.
Earthing with G.I Earth Plate 600mmx600mmx6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc with charcoal / coke and salt as required
Providing & laying of 25mmx5mm G.I strip fpr earthing in 40mm dia pipe FRL earth Electrode including connections with brass nuts,bolts spring washers etc,excuvation,refilling as required
Suply and installation of integral LED 4ft luminarie with CRCA housing and PC Glossy Cover.The luminarie should have a color consistency SDCM < 5,CRI> 80 and CCT of 6500K.The luminarie shall be compliant with IP 20 classification. Luminarie shall be designed to emitt at least 4000 nominal lumens at a system efficacy of attleast 115 lumens / watt with a maximum wattage of 34watts.The luminarie shall be designed so as to ensure lumen depriciation of upto 30% over 50K burning hours @ design ambient temp 45deg C. The electronic driver used shall have a power factor > 0.95 and THD < 10% and suitable for an operating voltage range of 140-270 V AC.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics,IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0,2007 for Electrical safety, IEC62384 ed 1.1, 2011 for perfofmance and IEC 61547 ed 2.0, 2009, CISPR-15 for EMI.Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above parameters
Supply,Installation of LED indoor Downlighter (Surface/ recessed) suitable for general lighting. Luminarie with CRCA housing having poly carbonate cover with diffused optics.The luminarie should have CRI>80 and CCT of 3000K/4000k/ 6500K.The luminarie shall be compilant with IP20 classification.The fixture should have a minimum system efficacy of 100 lumens/watt and a minimum system lumen output of 1200 lumen and a maximum system wattage of 12 watts.The luminarie shall be designed so as to ensure a lumen deprication of upto 30% over 50K burning hours @ design ambieent temp 45deg C.The electronic driver used shall have a power factor>0.95, THD<10%. The fixture should comply with the parameters as per ISI 0322.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics, IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0,2007 for Electrical safety,IEC62384 ed 1.1,2011 for perfofmance and IEC 61547 ed 2.0, 2009,CISPR-15 for EMI. Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify above parameter
Supply,Installation of integral LED 2ft luminarie with extruded aluminium housing with PC cover.The luminarie should have a color consistency SDCM<5,CRI>80 and CCT of 4000/6500K The luminarie shall be compilant with IP20 classification.The fixture should have a minimum system efficacy of100 lumens/watt and a minimum system lumen output of 1200 lumen and a maximum system wattage of 12 watts.The luminarie shall be designed so as to ensure a lumen deprication of upto 30% over 50K burning hours @ design ambieent temp 45deg C. The electronic driver used shall have a power factor>0.95, THD<10%. The fixture should comply with the parameters as per ISI 0322.The LED driver should comply to IEC 61000-3-2, 2009 for Harmonics, IEC61347-2-13<2006 in conjuction with IEC61347-1 ed.2.0,2007 for Electrical safety,IEC62384 ed 1.1, 2011 for perfofmance and IEC 61547 ed 2.0, 2009,CISPR-15 for EMI. Manufacturer shall have inhouse Lab. approved by NABL or ministry of Science of Govt,of india.LM79 & LM 80 reports need to be submitted from a NABL/ UL accredited lab to verify.above paramete
SITC of high-quality integrated LED Flood Light with a minimum system lumen of 23500 Lm and system wattage not exceeding 195W with a nominal efficiency 120 lumen/watt. CCT of 6500K with SDCM of < 5 and CRI : 70. The housing should be of non-corrosive high-pressure die-cast aluminum to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70. The Ingress protection should be minimum IP 66 with an IK rating of 09. The Luminaire should have a 10 KV /10 KA SPD duly bolted in the Luminaire . The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required.
Above 95 sqmm and upto 185 sqmm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X 150 sq. mm
Supplying of cables for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X 150sq. mm
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75 mmX75 mm)
3 Module (100mm X 75mm)
4 Module (125mm X 75mm)
6 Module (200mm X 75mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module
3 Module
4 Module
6 Module
Supply and laying of following dia PVC Conduit B class 2 mm thick along with accessories recess/ surface including cutting of walls and making good the same
25mm dia
32mm dia
N S ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .