Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.6 LAccepted-AOC AT MQ 49 BODIYA BASTI KATHARA BOKARO JHARKHAND 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | 1 | Accepted-AOC Accepted | |
| 2 | Rejected-Technical MAIN ROAD KATHARA BOKARO 829116 | BOKARO | BOKARO | JHARKHAND | 829116 | - | Rejected-Technical Not evaluated as not L1 | |
| 3 | Rejected-Technical PO SAWANG COLLIERY DIST BOKARO JHARKHAND | - | Rejected-Technical Not evaluated as not L1 |
Tender Value
Refer Docs
EMD Value
₹5,800
Closing Date
18 Sept 2023, 4:00 pmClosed
Staff officer ENM
Office of the staff officer EnM kathara Area
Internal Electrical repairing /rewiring of different type of qrts.no.(AAO/B-2, 1B/109.B/1,WB/87,WB/59,1C/3)at different colonies under G.M.Unit,Kathara Area
2023_CCL_288050_1
GMKTA/SOEnM/E-tender/23-24/09
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Kathara Area
Please refer Tender documents.
5 documents required · 5 mandatory
₹5,800
5 Nov 2023
6 Sept 2023
19 Sept 2023
7 Sept 2023
18 Sept 2023
7 Sept 2023
7 Sept 2023 - 14 Sept 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Grup-C.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 2.5 sq. mm + 2.5 sq. mm earth wire).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 1.5 sq. mm + 1 X 1.55 sq. mm earth wire).
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single pole and neutral).
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (2+4way/6way double door).
Supplying and fixing following piano type switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. A). 5/6 Amps.Switch
B). 5/6 Amps. Socket outlet.
C).15/16 Amps Switch.
D). 15/16 Amps Socket.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings)
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required
Earthing with G.I. earth plate 600mm x600mmx6mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangment and watering pipe of 2.7mtr.long etc with coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm.
Providing and fixing of PVC board 8"x10" (200mm x250mmx60mm)
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 Amp TP&N.
Total impact of GST for the purpose of CTC
M/S P. L. CONSTRUCTION
M/S SAGAR ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_298269.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .