| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹16.7 L+₹85,825 (5.42%)Rejected-AOC | L2 | Rejected-AOC Being L2 | |
| 3 | L3₹17.7 L+₹1.8 L (11.7%)Rejected-AOC 182 INDRA COLONY VILL DAMODARPURA POST TODABHATA TEA BASSI BASSI JAIPUR JAIPUR RAJASTHAN 303301 | JAIPUR | RAJASTHAN | 303301 | L3 | Rejected-AOC Being L3 | |
| 4 | L4₹19.1 L+₹3.3 L (20.6%)Rejected-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-AOC Being L4 | |
| 5 | L5₹19.5 L+₹3.7 L (23.2%)Rejected-AOC H NO 861 SECTOR 1 4 HOUSING BOARD COLONY NEAR POLY CLINIC HISAR HARYANA | HISAR | HARYANA | 125001 | L5 | Rejected-AOC Being L5 |
| Sl No | Description | Qty | Unit | KUNAL ENTERPRISES L6 | M/s Devendera construction L7 | M/S KAVITA CONSTRUCTION L8 | Balaji Construction Co. L3 | P S TRADERS L4 | BHATIA ENTERPRISES L1 | Natwadia Electrical Company L5 | FOUJI ELECTRIC WORKS L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminium point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks, DB, MCB etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed | 243 | PER POINT | 7 ₹1,701 | 10 ₹2,430 | 5 ₹1,215 | 10 ₹2,430 | 20 ₹4,860 | 2 ₹486 Lowest | 5 ₹1,215 | 5 ₹1,215 |
| 2.00 | All as per item No 1.00 (here-in-before) but excluding existing concealed conduit. | 3,200 | PER POINT | 7 ₹22,400 | 5 ₹16,000 | 5 ₹16,000 | 10 ₹32,000 | 2 ₹6,400 Lowest | 2 ₹6,400 Lowest | 5 ₹16,000 | 5 ₹16,000 |
| 3.00 | M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including cutting chases in walls and including concealed PVC non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type pressed modular steel box covered with white modular cover plate and frame for housing switches, sockets, fan regulators etc complete, all as specified & directed.
(Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).' | 75 | PER POINT | 317 ₹23,775 | 350 ₹26,250 | 300 ₹22,500 | 250 ₹18,750 | 250 ₹18,750 | 190 ₹14,250 Lowest | 210 ₹15,750 | 250 ₹18,750 |
| 4.00 | All as per item No 3.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch. | 40 | PER POINT | 317 ₹12,680 | 350 ₹14,000 | 300 ₹12,000 | 150 ₹6,000 Lowest | 220 ₹8,800 | 190 ₹7,600 | 210 ₹8,400 | 250 ₹10,000 |
| 5.00 | All as per item No. 3.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board from DB | 36 | PER POINT | 317 ₹11,412 | 350 ₹12,600 | 300 ₹10,800 | 190 ₹6,840 Lowest | 220 ₹7,920 | 230 ₹8,280 | 210 ₹7,560 | 250 ₹9,000 |
| 6.00 | All as per item No. 3.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board. | 50 | PER POINT | 77 ₹3,850 | 100 ₹5,000 | 150 ₹7,500 | 150 ₹7,500 | 80 ₹4,000 | 20 ₹1,000 Lowest | 65 ₹3,250 | 70 ₹3,500 |
| 7.00 | All as per item No. 3.00 (here-in-before) but for one 5 amps socket outlet independent but below the switch board of light points in the same vertical or horizontal plane | 2 | PER POINT | 317 ₹634 | 350 ₹700 | 300 ₹600 | 175 ₹350 Lowest | 180 ₹360 | 220 ₹440 | 210 ₹420 | 250 ₹500 |
| 8.00 | All as per serial item No. 3.00 (here-in-before) but for one bell/buzzer point controlled by one bell push. | 2 | PER POINT | 317 ₹634 | 350 ₹700 | 300 ₹600 | 175 ₹350 Lowest | 180 ₹360 | 250 ₹500 | 225 ₹450 | 250 ₹500 |
| 9.00 | All as per srl item No. 3.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multistranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed | 40 | PER POINT | 377 ₹15,080 | 450 ₹18,000 | 350 ₹14,000 | 250 ₹10,000 Lowest | 300 ₹12,000 | 270 ₹10,800 | 250 ₹10,000 Lowest | 300 ₹12,000 |
| 10.00 | M & L for point wiring for one light controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS drawn through existing PVC coduit and conduit accessories in existing concealed type in walls/ceilings and including sunk type pressed modular steel box covered with white modular cover plate and frame for housing switches, sockets, fan regulators etc including sunk type pressed modular steel box covered with white modular cover plate and frame for housing switches, sockets, fan regulators etc’, including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete complete all as specified and directed
(Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ). | 1,655 | PER POINT | 247 ₹4,08,785 | 160 ₹2,64,800 | 200 ₹3,31,000 | 200 ₹3,31,000 | 80 ₹1,32,400 Lowest | 165 ₹2,73,075 | 165 ₹2,73,075 | 170 ₹2,81,350 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
11 Oct 2025, 6:00 pmClosed
GE Hisar
GE Hisar
REPAIR / REWIRING IN KLP LOCATION ALONGWITH LIGHT FITINGS AND OTHER MISC WORK IN OTM ACCN AT HISAR MIL STN UNDER GE HISAR
2025_MES_731280_1
GE(H)-43/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE Hisar
As per NIT
6 documents required · 6 mandatory
₹500
GE Hisar
₹64,000
Yes
29 Nov 2025
18 Sept 2025
21 Oct 2025
18 Sept 2025
11 Oct 2025
3 Oct 2025
Amount
Taking down carefully copper/aluminium point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks, DB, MCB etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed
All as per item No 1.00 (here-in-before) but excluding existing concealed conduit.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including cutting chases in walls and including concealed PVC non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type pressed modular steel box covered with white modular cover plate and frame for housing switches, sockets, fan regulators etc complete, all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).'
All as per item No 3.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 3.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board from DB
All as per item No. 3.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per item No. 3.00 (here-in-before) but for one 5 amps socket outlet independent but below the switch board of light points in the same vertical or horizontal plane
All as per serial item No. 3.00 (here-in-before) but for one bell/buzzer point controlled by one bell push.
All as per srl item No. 3.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multistranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed
M & L for point wiring for one light controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS drawn through existing PVC coduit and conduit accessories in existing concealed type in walls/ceilings and including sunk type pressed modular steel box covered with white modular cover plate and frame for housing switches, sockets, fan regulators etc including sunk type pressed modular steel box covered with white modular cover plate and frame for housing switches, sockets, fan regulators etc’, including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete complete all as specified and directed (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).
All as per item No 10.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 10.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board from DB
All as per item No. 10.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per item No. 10.00 (here-in-before) but for one 5 Amp socket outlet independent but below the switch board of light points in the same vertical or horizontal plane
All as per item No. 10.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed.
S&F modular switch 1 way 6 Amp, 230V 1 module all as specified & directed.
S&F modular switch 1 way 16 Amp, 230V 1 module all as specified & directed.
S&F modular Socket, 6A - 5 pin 2 module 230 volts AC complete all as specified
S&F modular Socket 6A/16A - 5 pin 2 module, 230 volts AC complete all as specified
S&F modular lamp holder, insluated body, with back plate suitable for batten fittings & complete all as specified & directed.
S&F modular ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
S&F modular Ceiling fan regulator 2 Module, 230V suitable for 1200mm/1400mm ceiling fan etc complete all as specified and directed.
S&F modular bell push 1 way 6 Amp, 230V 1 module all as specified & directed.
S&F Bell ding dong type, AC, 230 Volts, single pole.
S&F sheet metal enclosure distribution board SP&N, 8 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating Aluminium bus bar, complete all as specified & directed.
S&F sheet metal enclosure distribution board SP&N, 12 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating Aluminium bus bar, complete all as specified & directed.
S&F sheet metal enclosure distribution board TP&N, 4 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating Aluminium bus bar, complete all as specified & directed.
S&F MCB SP, 6 to 32 Amps 240 Volts , 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed.
S&F MCB SPN, 32 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed.
S&F MCB TPN, 63 Amps 415 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC conduit will be measured as one length.
All as per item No 31.00 (here-in-before) but cable of size 6 sqmm drawn through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 4 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 4 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- Two lengths of 4 Sqmm cable, one length of 4 Sqmm cable and one length of PVC conduit will be measured as one length.
All as per item No 33.00 (here-in-before) but cable of size 4 sqmm drawn through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 2.5 sqmm, 1100 votls grade drawing through and including concealed/above conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 2.5 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- Two lengths of 2.5 Sqmm cable, one length of 2.5 Sqmm cable and one length of PVC conduit will be measured as one length.
All as per item No 35.00 (here-in-before) but cable of size 2.5 sqmm drawn through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 1.5 sqmm, 1100 votls grade drawing through and including concealed /above conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 1.5 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- Two lengths of 1.5 Sqmm cable, one length of 1.5 Sqmm cable and one length of PVC conduit will be measured as one length.
All as per item No 37.00 (here-in-before) but cable of size 1.5 sqmm drawn through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
Supply and fixing LED lights fitting 1x 40W, 220V,AC wall mounted LED batten with aluminium housing & integrated electronic driver with efficacy of 100lumen/W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED lights fitting 1x 10W, 220V,AC wall mounted LED batten with polycarbonate housing & integrated electronic driver with efficacy of 100lumen/W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED luminaire 1Ft x 1Ft , 24 watt, (warm white / cool day light / natural light) 220 V AC surface mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, (warm white / cool day light / natural light) 220 V AC surface mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder aluminium housing connecting up with three core flexible copper conductor cable of suitable size.
S&F sheet metal enclosure Single pole and neutral with a two pin and earth plug and socket complete with and including one 20 Amp SPN MCB 'C' curve complete all as specified.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
Supply and fixing LED street light fitting 20 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including 1.5 mtr 25mm GI pipe bent to shape as angle bracket fixed on building as building security light complete all as specified and directed
S& F Rigid non-metallic of size 25mm inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
S&F in replacement cable FRLS, PVC insulated and PVC sheathed size 1.5 sqmm three core multistranded copper conductor cable inclding PVC wire connectors complete all as specified & directed.
S&F in replacement 10 W LED bollard light , IP 65 having step profile on top idel for out door lighting , typically giving off light complete all as specified & directed. Make Orient Cat part No LLSBL-10-W or equivalent crompton, Havells, Wipro
S&F in replacement post top LED lantern of capacity 45 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 , spun aluminium and high grade aluminium heat sink for efficient thermal management , sturdiness and excellent corrosion resistence . MS Base provided to support the housing complete with driver and LED lamp all as specified & as directed.
FOUJI ELECTRIC WORKS (BID ID -3448254)
Balaji Construction Co. (BID ID -3448644)
P S TRADERS (BID ID -3448666)
Natwadia Electrical Company (BID ID -3445091)
KUNAL ENTERPRISES (BID ID -3447451)
M/s Devendera construction (BID ID -3448123)
M/S KAVITA CONSTRUCTION (BID ID -3448180)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .