Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 01₹48.9 LAccepted-AOC VPO DATARPUR TEH MUKERIAN DISTT HOSHIARPUR | HOSHIARPUR | PUNJAB | 144105 | 01 | Accepted-AOC AWARD | |
| 2 | 02₹54.0 L+₹5.0 L (10.3%)Rejected-Finance PUNJAB | GURDASPUR | PUNJAB | 143505 | 02 | Rejected-Finance HIGHEST |
Tender Value
₹42.2 L
EMD Value
₹84,377
Closing Date
21 May 2021, 12:00 pmClosed
EXECUTIVE ENGINEER
WATER SUPPLY AND SANITATION DIVISION NO 1 PATHANKOT
AUGMENTATION WATER SUPPLY SCHEME SHAHPUR KANDI BLOCK DHAR DISTT PATHANKOT
2021_WSS_64722_1
CIVILWOKR_2020_21_30
Open Tender
Civil Works
Item Rate
180 days
DAC MALIKPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹100
₹84,377
Yes
15 Jul 2021
6 May 2021
21 May 2021
6 May 2021
21 May 2021
6 May 2021
Amount
Providing, Stringing out, cutting, jointing and testing of ISI marked C.I Pipes Class-LA per IS:1536 and laying the same in trenches to correct alignment and gradients, jointed with rubber tyton joints fitted including cost of excavation complete including all cartage
150mm i/d (C.I Pipe)
PUMPING MACHINERY
Providing & Installing Testing & Commissioning of one No. Electrically driven Submersible Pumping set of reputed make capable of delivering 606 LPM against a head of 72 mtr along-with electric panel board consisting of electric such as automatic Starter, Main Switch. Volt Meter, Ampere Meter, ELCB, Shunt Capacitor, Single Phase Preventer, Indicating Lamps, MVB/MCCBs etc. including M.S. Column Pipe of suitable size 90 m (in 3 m Lengths each with flanges, screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable (of reputed make) complete in all respects.
Rate of Motor with Pump
Panel Board
Submersible cable Size 4.00mm2
Column Pipe (G.I) 100 mm i/d
Providing & testing of Multistage Horizontal Centrifugal (MHC) 9 Stage Pump set make KSB/Mathur Plat/Kirloskar/Crompton or equiplent make (with bronze impeller) cable of delivering 833 LPM discharge, 155 mtr head, slow speed 1440 RPM with suitable electric motor consisting of Controller (Volt meter, Ampere Meter, ELCB, Single Phase Preventer) Steel Base plate for pump and motor complete in all respects.
Panel Board (Automatic)
Electric cable Copper 19/16mm/35mm
DISINFECTION UNIT Providing Installing testing and commissioning and one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 ltr of bleaching powder solution/ sodium hypo solution per hrs under maximum deliver pressure upto 7kg/cm2 and suction left not less than 1.5 meter. (Milton roy or Equivalent make)
Providing & fixing C.I D/F Sluice Valves ISI marked 14846-2000, including cost of tail piece, rubber joint, gland dori, Nuts, bolts & accessories, complete in all respects
150 mm Nominal Bore (N.B.)
Provision for construction of One no. RCC Collecting Tank 3.00 mtr dia of 20000 ltr Cap consisting of collecting tank with core wall and 3.05 mtr working depth complete in all respect (Drawing and Design submitted by the Contractor)
2 No Pump Chamber already Constructed at site
Terracing consisting of tiles 22.86cm×11.43cum×3.83cm laid over25mm mud plaster, 7.50 cm mud filling on an other layer of 25mm mud plaster including two coats of bitumen laid hot @ 1.65Kg. Per Sqm on top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc
12.5mm thick plaster in 1:4 under side of ceiling
Hollock wood doors shutter windows including Hinges, Screws, Chocks Cleats, Stops and Cords etc. complete fixed in position (double Leaf) @ Paneled glazed or glazed and paneled
Applying Pink Primer or-aluminium priming coat including preparation of surface With special quality paint
Painting two coats excluding priming coat with ready mixed paint in all shades on new wood work With special quality
Cement Cencrete 1:2:4 gola 10cm×10cm concave quardrant along junction of roof with parapet wall finished smooth where specially specified
White washing 3 coats inside of pump chamber
Finishing wall with exterior decorative cement based paint such as snowcem robbiacem etc. on new work in two coats to give even shade.
Providing and fixing of Glass strips 4mm thick in floors
50mm wide
40mm wide
Supplying & fixing glass panes including special metal sash putty of approved make.
RECESSED CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES:
Wiring in PVC insulated copper conductor single core FRLS cable (ISI marked), 1100volts grade to be laid in heavy gauge welded conduit pipe 20 mm/25 mm dia (1.6mm thick) ISI Marked, recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for having electronic fan regulators (socket size), bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20 Amp. Sockets and 6 Amp./16/20Amp. Swithces (flush piano type accessories) etc.and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., & including the cost of flush piano type switches/sockets, step type electronic fan regulator 100 watts, PVC connector (For Fan Box andElectronic Buzzer), PVC Bush, Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases:-
Wiring fan point without fan box in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts (socket size).
Wiring light point in PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1.5 sq. mm, 1100volts grade.
Wiring 3 Pin 6 Amp. Plug control comprising wall socket and switch including bonding to existing earth with PVC insulated copper conductor single core FRLS cable (ISI marked) overall 1 sq. mm, 1100volts grade complete
Wiring 3 pin 16/20 amp. power plug control and switch.
Providing and fixing of ceiling fan of reputed make such as Crompton or equivalent
Providing and fixing of electric tube set of reputed make
Extra provision for sanitary latrine in pump chamber
Repair of existing Collecting Tank 100000 ltr Cap
Reinforced Cement Concrete work hand mixed 1:1 ½:3 for walls 10 cm to 20 cm thickness and dom, straight curved excluding steel reinforcement upto 110 Kg. per Cum of Centering and Shuttering laid in position. Completed in all respect.
Shuttering for C.T and also for smooth surface
Cold twisted deformed Tor Steel for RCC works including bending and placing in position complete
Carriage of odd jobs (a) Mazdoor Load upto 40 Kg & Distance of upto 3 Km.
Provision for 1 No. ladder inside and outside the C.T including Carriage from market to site of work.
Providing, laying, jointing, fixing & testing of GI Pipe and specials Class-B including cost of material, complete in all respects including excavation and all taxes as per DWSS approved analysis of rates including excavation.
GI Pipe 100mm i/d
MS Pipe 150mm i/d
Making Connection with existing pipe line including cutting cost of D-Joint, labour for fixing specials excavation bailing out etc.
Providing & fixing C.I D/F S.V. including cost of tail piece, rubber insertion, gland dori, Nut bolts & accessories complete in all respects.
Construction of masonry sluice valve chamber size 0.60m x 0.60m complete in all respect.
Construction of masonry sluice valve chamber size 0.90m x 0.90m complete in all respect.
Analysis of Arrangment for Regulating Water Supply of Existing Connections so as to ensure equal distribution of water to all households, Particullarly at tail end
Ravinder Kumar
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .