Loading…
Loading…
Tender Value
₹3.8 L
EMD Value
₹3,900
Closing Date
5 Oct 2026, 4:00 pm
Executive Engineer (Electrical),
Office of the Executive Engineer (Electrical), P.W.D., Electrical Division, Thiruvarur.
Special Repairs to Electrical Installation, Fans, Water Heater and Split type AC unit arrangements to the Inspection Bungalow in Vilamal at Thiruvarur in Thiruvarur District.
2026_PWD_706404_1
87/2026-27/ ELE/TVR
Open Tender
Electrical Works
Lump-sum
30 days
Thiruvarur
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹3,900
21 Sept 2026
21 Sept 2026
6 Oct 2026
21 Sept 2026
5 Oct 2026
21 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Rewiring with 2 x 1.5sq.mm PVC insulated unsheathed FRLS SC copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A FT switch inflush with wall covered with hylem sheet of 3mm thick with painting of suitable colour for open PVC light / fan point (for electronic regulator) (5 points per coil) | 15 | Nos | 1,641 | ₹24,615 |
| 2 | Renewal by supply and fixing of 4feet LED 20W fitting with LED 20W tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting. | 10 | Nos | 1,078 | ₹10,780 |
| 3 | Renewal by supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher End) with 600mm down rod on the existing fan clamp. | 7 | Nos | 2,846 | ₹19,922 |
| 4 | Renewal by supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall. | 7 | Nos | 2,033 | ₹14,231 |
| 5 | Renewal by supply and fixing of 3Nos 5A (3pin and 2pin) combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection. (for computer plug socket) | 4 | Nos | 650 | ₹2,600 |
| 6 | Renewal by supply and run of 2 of 2.5sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5sq.mm copper wire with painting of suitable colour. | 50 | Mtrs | 203 | ₹10,150 |
| 7 | Renewal by supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting . | 5 | Nos | 6,148 | ₹30,740 |
| 8 | Renewal by supply and fixing of 1500W automatic electric water heater of 35 litres capacity suitable for 230V, 50c/s, AC supply on suitable MS clamps with 3 core flex wire but without plumbing connection. | 3 | Nos | 9,089 | ₹27,267 |
| 9 | Renewal by supply and fixing of 1 x 4 40W LED fitting with LED tube complete with TW round blocks on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting. | 4 | Nos | 1,697 | ₹6,788 |
| 10 | Renewal by supply and installation of 2.0TR (60000 K.cal/Hr) ABS Plastic Split type Air Conditioner conforming to with rotary compressor operating on refrigerant non CFC suitable for wall mounting for operation on 230V, 50Hz, single phase AC supply as per BEE specification and capable of performing the functions of Cooling, Dehumidifying, Air Circulating, Filtering. The installation works for the above split type AC units includes the following: 1. Mounting / Fitting Indoor and outdoor units at their respective locations. 2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole / holes in the wall if required. 3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing. 4. Laying 25mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit. 5. Leakage testing the entire system unit. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoor units upto 6 Mtrs length and upto switch within 3 Meters of location of indoor unit. | 2 | Nos | 58,900 | ₹1,17,800 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.67 MB
Inspectionbungalowvilamal.pdf
Tender Documents • 0.77 MB
BOQ_849005.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .