| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC INDEX NO B 132 HQ ADG P CHENNAI NO 229 ANGAPPAN STREET MITTANAMALLI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹41.4 L+₹10.5 L (33.8%)Rejected-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | Rejected-Technical 203 1 THIRUMATHI SUNDARI ILLAM CHINNAMMEN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | - | Rejected-Technical not meeting eligibility criteria |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
19 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
87617E8 REPAIRS AND REPLACEMENT AS IN EXT ELECT WORKS AT ARMY AF DOMESTIC AREA UNDER GE AVADI
2020_MES_389346_1
87617E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AVADI, CHENNAI
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE AVADI CHENNAI
₹76,000
Yes
22 Jan 2021
23 Oct 2020
23 Nov 2020
23 Oct 2020
19 Nov 2020
6 Nov 2020
23 Oct 2020 - 30 Oct 2020
60 days
Amount
BOQ UPLOADED ON 23 OCT 2020
SCH "A" PART-I (EXTERNAL ELECTRIFICATION)
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for and removal of unserviceable debris to a distance not exceeding 100m complete all as specified and as directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5m depth and getting out in any type of soil all as specified and as directed.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and exceeding 1.5m but not exceeding 3.0m in depth and getting out in any type of soil all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
Dry river sand laid to required width of trench at bottom and top for cable cushioning all as specified and as directed.
Punned thickness only shall be measured.
Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Removing of old bricks / brick bats and taken on credit abd provision of Burnt bricks sub class "B" of old size, designation 50, laid dry in trenches with width equal to length of bricks across the cable for cable protection all as specified and as directed.
Plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in foundation of poles, stay assembly complete all as specified and as directed.
Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation of poles, stay assembly complete all as specified and as directed.
Plain cement concrete, type C1, 1:3:6, using 20mm graded granite stone aggregate as in coping of poles, stay assembly above ground level including weathering, slightly rounded or chamfered angles, including necessary formwork complete all as specified and as directed.
Taking out existing cable any type / cross section upto 16sqmm and provision of XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, in trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments of the following sizes complete all as specified and as directed.
Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately.
(a) 2 core, cross sectional area 10 sqmm.
(b) 2 core, cross sectional area 16 sqmm.
Taking out existing cable any type / cross section exceeding 16 sqmm but not exceeding 185 sqmm and provision of XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, in trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments of the following sizes complete all as specified and as directed.
Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately.
(a) 4 core, cross sectional area 25 sqmm.
(b) 3.5 core, cross sectional area 50 sqmm.
(c) 3.5 core, cross sectional area 70 sqmm.
(d) 3.5 core, cross sectional area 95 sqmm.
(e) 3.5 core, cross sectional area 120 sqmm.
Taking up and down steel tubing and connections and taken on credit and provision of Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and laid in trenches / under roads / crossings etc., of the following bores for cable protection complete all as specified and as directed.
Earthwork as required shall be measured and paid separately.
(a) 50mm bore of pipe.
(b) 80mm bore of pipe.
Dismantling old unserviceable pole and taken on credit and provision of prestressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10, including preparing the surfaces and painting the pole to a height of 1.50m from top of coping in alternate strips of black and white of 300mm width with two coats of synthetic enamel paint and numbering the pole with letters 100mm wide and 100mm height , white colour on black back ground roound or square complete all as specified and as directed.
Earthwork, PCC foundation, coping etc as required for erection of pole shall be measured and paid separately.
Dismantling old unserviceable ACSR conductor as in over head lines from poles and taken on credit and provision of new aluminium conductor steel reinforced (ACSR) conductors of assorted sizes stringed on poles and connecting complete all as specified and as directed.
The weight of ACSR conductor only shall be measured as per preamble given in Sl Page No.384 of SSR Part-II 2010.
Dismantling old unserviceable earth wire as in over head lines / cradle guards etc from poles and taken on credit and provision of new galvanised steel wire 3.15mm or 4.00mm dia as continous earth wire and cradle guards fabricated into hexgonal or rectangular shape stringed on poles including copper binding wire and connecting complete all as specified and as directed.
The weight of earth wire and cradle guards only shall be measured as per preamble given in Sl Page No.384 of SSR Part-II 2010.
Dismantling cross-arms of mild steel channel or angle sections etc., complete and taken on credit and provision of new Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
Dismantling stay assembly complete and taken on credit and provision of new stay assembly complete with all accessories as shown in electrical plate No.1 of SSR Part I. consisting of stay rod 20mm dia, 1.80m long, stay plate 300mm x 300mm x 6mm complete all as specified and as directed.
Demolition of concrete, loop type insulators, stay clamps, earthwork, PCC foundation, coping etc as required for erection of stay assembly shall be measured and paid separately.
Dismantling of old unserviceable stay strand any size and taken on credit and provision of new galvanised stay strand of size 7/3.15mm fixed one end with pole and the other end with stay rod complete all as specified and as directed.
Dismantling loop type insulators complete and taken on credit and provision of loop type insulator, large size, vitreous, porcelain, white, brown or green, with overall dimensions 90mm x 140mm, clearance of hole 25.5mm complete all as specified and as directed.
Dismantling shackle type insulators complete and taken on credit and provision of new shackle type insulator, porcelain, vitreous, vitreous, porcelain, white, brown or green,, including galvanised bolts, washers and nuts having maximum dia of 90mm and height of 75mm, with working pressure 1100 volts, with GI straps of 31x3mm and bolts of 12mm dia complete all as specified and as directed.
Dismantling anti-climbing device complete and taken on credit and provision of new Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole and inclusive of one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT, 200mm x 150mm size as in repairs complete all as specified and as directed.
Taking out existing service cable any type / cross section and provision of PVC insulated aluminium solid conductor, of size 10 sqmm as in service connections, 1100 volts grade heavy duty cable served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and as directed.
Earth continuity conductor or main earthing lead of 25 x 3mm aluminium strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required as in repairs complete all as specified and as directed.
Earth continuity conductor or main earthing lead of 32 x 6mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required as in repairs complete all as specified and as directed.
Removing of existing crushed aggregate filling and provision of new 20mm graded stone aggregate as loose filling of free from deletrious materials as in plinths of HT/LT 2/3/4 pole structures, outdoor transformers, sub stations, panel boards yard etc., including setting the existing bricks for retaining the aggregate complete all as specified and as directed.
MCCB 100 Amps, 4 pole, 415 Volts, 3 phase, 50 Hz, 25 kA breaking capacity, with adjustable thermal and magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu having spreader links and barriers as standard feature of manufacturer as in repairs complete all as specified and as directed.
(a) Make shall be Havells Cat No. IHLASDCF0100 or equivalent of makes as listed here-in-after.
MCCB 160 Amps, 4 pole, 415 Volts, 3 phase, 50 Hz, 25 kA breaking capacity, with adjustable thermal and magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 75% of Icu having spreader links and barriers as standard feature of manufacturer as in repairs complete all as specified and as directed.
(a) Make shall be Havells Cat No. IHLANDCF0160 or equivalent of makes as listed here-in-after.
MCCB 200 Amps, 4 pole, 415 Volts, 3 phase, 50 Hz, 36 kA breaking capacity, with adjustable thermal and magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 100% of Icu having spreader links and barriers as standard feature of manufacturer as in repairs complete all as specified and as directed.
(a) Make shall be Havells Cat No.IHLLSECF0200 or equivalent of makes as listed here-in-after.
MCCB 250 Amps, 4 pole, 415 Volts, 3 phase, 50 Hz, 36 kA breaking capacity, with adjustable thermal and magnetic setting with protection for overload and short circuit and conforming to IEC60947 / IS 13947 (Pt-II) 1993 (Latest version) and with Ics = 100% of Icu having spreader links and barriers as standard feature of manufacturer as in repairs complete all as specified and as directed.
(a) Make shall be Havells Cat No.IHLLSECF0250 or equivalent of makes as listed here-in-after.
Taking down existing unserviceable street light fitting including brackets and provision of LED street light fitting 48 W, highly efficient made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. including provision of necessary GI tubing medium grade 40mm bore of pipe 1.5 bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to steel tubular poles etc complete all as specified and as directed.
(a) Make shall be Havells Cat No.ENDURAPEARLNEOSL48WLED757PASYTOPC or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer Particular Specification hereinafter.
Taking down existing unserviceable street light fitting including brackets and provision of LED street light fitting 60 W, highly efficient made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. including provision of necessary GI tubing medium grade 40mm bore of pipe 1.5 bent to shape with necessary clamps made out of mild steel, nuts and bolts etc., including two coats of synthetic enamel paint over a coat of red oxide primer on exposed steel surface for fixing the fitting to steel tubular poles etc complete all as specified and as directed.
(a) Make shall be Havells Cat No.ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent of makes as listed here-in-after.
(b) For all other mandatory requirements of LED fittings, please refer Particular Specification hereinafter.
Removing of old earthing materials and taken on credit and provision of new earthing complete with galvanised iron earth plate electrode 600mm X 600mm X minimum 6mm thick, with and including earthing of 32mm x 6mm GI strip protected by 40mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Removing of old earthing materials and taken on credit and provision of new earthing complete with galvanised iron earth plate electrode 600mm X 600mm X minimum 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
Aluminium bus bars with heat shrinkable sleeves in R, Y, B and black colour fixed in existing panel of size as per site requirement as in repairs complete all as specified and as directed.
Pruning of tree branches and making clear way for LT / HT lines, 2 to 6 conductors including disposal of cut branches, leaves, debris etc., to a distance not exceeding 50m from the starting point complete all as specified and as directed.
Painting of steel tubular pole 9m long in position complete after preparing of surfaces and applying two coats of synthetic enamel paint and numbering the pole with letters 100mm wide and 100mm height , white colour on black back ground round or square complete all as specified and as directed.
BKR Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .