Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-Finance NOT AVAILABLE | L1 | Accepted-Finance Being lowest tenderer | |
| 2 | L2₹9.5 L+₹1.1 L (13.4%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L2 | Rejected-Finance Not being lowest tenderer | |
| 3 | L3₹9.7 L+₹1.3 L (15.6%)Rejected-Finance NOT AVAILABLE | L3 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹9.8 L
EMD Value
₹19,500
Closing Date
8 Feb 2024, 6:00 pmClosed
AGE I ASVINI
AGE I ASVINI RC CHURCH COLABA MUMBAI
PROVISION OF SS BASED ENDOSCOPY SUITS AND STORAGE UNIT IN ADVANCE ENDOSCOPY THEATRE PROVISION OF AIR CURTAINS IN ICU AND ADDITION ALTERATION TO STAIRCASE NEAR PATIENT GALLEY AT INHS ASVINI
2024_MES_636945_1
8432/E8
Open Tender
Civil Works
Item Rate
180 days
AGE(I) ASVINI, RC CHURCH, COLABA
Class E category a(i)
7 documents required · 7 mandatory
₹500
AGE I ASVINI
₹19,500
Yes
24 Feb 2024
11 Jan 2024
9 Feb 2024
11 Jan 2024
8 Feb 2024
25 Jan 2024
11 Jan 2024 - 1 Feb 2024
Amount
Supply , fabrication and installation in position of ENDOSCOPY SUITS and storage unit will be made with 1.2mm thick SS 304 sheet for racks and frame and 0.8 mm for door sheet of panel size 45 to 50 mm designed to fit flush into the wall with grouting and accessories specified by the manufacturer. The The storage unit will be divided in to 2 equal parts and each door will have sandwitch glass sections. The thickness of glass should be 8 mm .the storage unit shall have a locking system and ss handle in each shutter .The storage will have SS 304 racks with glass doors . The design of unit should be customize storage unit of size : 875 mm x 350 MM wide and 4150 mm height endoscopy suit with 9 No of SS hooks inside (with single glass door and no racks inside) and 1750 mm X 350 MM wide and 4100 mm(2050+2050) height storage rack divided into two equal parts horizontally with double sandwitch glass doors in each part .The upper part of storage unit includes 3 horizontal member of 1750 mm long and 3 vertical members 2050 mm long .The lower part of storage unit includes 3 horizontal member of 875mm long and 2 vertical members 2050 mm long with multiple racks as specified complete all as specified and directed Make :- WIESPL, Magnateck Enterprises, Hospedia medicare Note : The work shall include all type of civil works including grouting and its instrumentation,accessories, fittings, unloading,lifting and shifting at site and any other connected items required for fixing of the endoscopy suit and racks
Demolition of reinforced cement concrete of staircase , roofs, floors beams.walls,landing,chajja and any suspended works carefully any position using adequate machinery and making good the disturbed surfaces using necessary equipments carefully without damaging the building and removing the debris frequently without impacting the load to structure with directions of Engr-in-Charge and removing the debris out of MD land ( reinforcement cut is required to facilitate demolition)
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.and removing debris out side MD land. Note: The place of disposal shall be find out by the contractor.
M&L granite (of any type) tiles 12 mm thick of approved colour and pattern machine cut, in skirting/ dado etc. vertical surfaces laid over cement screed, and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete and including 10mm thick backing coat in CM (1:4) complete all as specified and as directed by Engineer In Charge
Taking down cement plaster, any description on brick or stone walls, etc including racking out joints hacking for key scrubbing down with water etc.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of any description in CM (1:4)with Ready mix plaster mixed with integral water proofing compound and finished even & smooth without using extra cement completed all as specified. (Note : WPC will be measured and paid separately)
Supply only water proofing compound of approved make
Chipping ,removing carefully concrete work by low impact hammer ,breaker without damaging the structure & cleaning and disposal of debris out side the premises etc. complete as directed by Engr-in-Charge. Hard concrete should not be removed by force.
M & L for clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete, Applying two coats of alkaline rust converting primer FEOVERT of Krishna Conchem or Roff rust cleaner of Piddilite or Dr Fixit Rust removal or sholirust of STP Ltd. on the rebars,including cleaning the reinforcement ,wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry.
M & L for providing and fixing additional steel bar or stirrups of diameter in variuos structural elements like columns,beams and foundations including drilling,bending and fixing the bars with epoxy putty etc. complete as directed by Engr-in-Charge.
M & L for applying two coats of anticorrosive Treatment to Reinforcement by application of two coats of anti-rust protective coating in the form of Acrylic Polymer with a minium splid content to 40% solid mixed with cement in 1:1.5 proportion ( 1 part polymer and 1.5 part cement) on rebars after cleaning of rust scales with time interval of minimum 4 hours between each coat by brush as per manufacturers instruction.Anti-rust protective shall be procured from one of manufacturer given below. (Make :- Fosroc/Sika/BASF/Krishna Conchem)
M & L for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete all complete as directed by Engr-in-Charge.
M & L for building up the profile of structural members by using latex B2 modified air cured mortar system in damaged areas (1Cement-3 part graded cleaned pre-packed river sand 10% latex mortar by weight of cement-0.5 w/c ratio) upto 20 mm to 40 mm thickness including leveling profiling and removing and cleaning existing vegetation growth in structural and Non structural items all complete etc. all complete as directed by Engr-in-Charge. (Make :- Fosroc/Sika/BASF/Krishna Conchem)
M& L for rolled MS section (Fe 410-(grade 250)quality A) for roof trusses (framed) including trussed purlines,posts,brackert framing for beam,tees,angle,channel,or flat sections including distance pieces cleats etc
Dismantling of sheeting including all fittings
M & L for prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as specified.
M&L preparation of new steel surfaces of any description and applying two coats of synthetic enamel paint over one coat of red oxide primer over 10cm width or girth complete all as specified and directed.
Supply, install, commissioning & testing of commercial Air curtain unit (Sensor based) for prevention of dust & conditioned air losses, Single phase, 220 V, 50 Hz, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer & final coat of synthetic enamal paint (oven baked) with MS-CRC 18 gauge square perforated suction grills, Aluminium alloy fans & single phase electric motor, nozzles etc, complete with fittings & accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening as specified size of 46''x78'' or equivalent
Unitech Enterprises
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .