| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹33.0 L+₹1.8 L (5.67%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹33.2 L+₹2.0 L (6.30%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹33.3 L+₹2.0 L (6.53%)Rejected-Finance C2 PAIXOMONTIRO APTS BEHIND NSD ALTO DABOLIM VASCO DA GAMA GOA 403 801 | SOUTH GOA | GOA | 403801 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹33.4 L+₹2.1 L (6.66%)Rejected-Finance H NO 767 NEAR OLD POST OFFICE NEW VADDEM VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹31.2 L
EMD Value
₹62,400
Closing Date
14 Apr 2021, 6:00 pmClosed
SHRI JANAK RAJ EE GARRISON ENGINEER NW
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802.
8346/E8
2021_MES_432374_1
8346/E8
Open Tender
Civil Works
Item Rate
90 days
VASCO
Class D Category a i
8 documents required · 8 mandatory
₹500
Yes
GE NW VASCO
₹62,400
Yes
15 May 2021
23 Mar 2021
16 Apr 2021
23 Mar 2021
14 Apr 2021
8 Apr 2021
23 Mar 2021 - 7 Apr 2021
Amount
PROVISION OF NEW ENTRANCE GATE ALONGWITH BOUNDARY WALL NEAR DSC POST AT NAY (GOA) UNDER AGE B/R – I (B/R PORTION)
M&L Demolition of Brick/ Block masonry bult in cement mortar.
M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified (Type C1,1:3:6 20 mm Aggregate)
M&L Excavation in trenches not exc. 1.5 m in depth and not exc 1.5 m wide in soft disintegrated rock for foundation and getting out
M&L PCC type D2 1:4:8 (40mm aggregate) in foundations filling and mass concrete
M&L RCC Type B1 (1:2:4), 20mm graded aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
M&L RCC Type B1 (1:2:4), 20mm graded aggregate as in beams all as specified and directed by Engineer-in-Charge.
M&L RCC Type B1 (1:2:4), 20mm graded aggregate as in Columns, pillars, piers, posts and struts
M&L RCC Type B1 1:2:4, 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed.
M&L Mild steel bars 10 mm dia and over, cut to length, bent to shape required including crancking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT Bars.
M&L Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including crancking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT Bars.
Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Use and waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions
Use and waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Providing, cement concrete in copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating & formwork, as directed by Engineer-in-Charge.
Providing 10mm thick plaster in CM (1:4) mixed with 3% integral water proofing compound over roof top surface finished to even & smooth w/o using extra cement. Note :- Integral water proofing compound will be measured and paid separately
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the morther slab. Filling the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1st Priming coat (Dr. Fixit primeseal or equivalant) on prepared concrete/plastered surface by diluting 2 parts of Primeseal with 1 (one) part of water and allow to dry for 04 (four) hours. Apply the first coat of waterproofing coating (Dr. Fixit Newcoat / Waterseal Concentrate of M/s Krishna Conchem Products) without any dilution at the rate of 2 Sqm per liter over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completly. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as directed and as per manufacturers instructions.
M&L Rendering 15 mm thick cement plaster on concrete solid block walls in CM 1:4 finished to even & smooth w/o using extra cement.
M&L Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with 3% integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid separately.
M&L Rendering 5 mm thick cement plaster on ceiling in CM 1:3 mixed with 3% integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing compound will be measured and paid seperately.
Supply only water proofing compound
M&L Preparing new plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall
M&L Preparing new plastered ceiling surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling.
M&L Preparation of New plastered surface and applying two coats of weather proof high glove antifungal paint on external surface with suitable primer
M&L Granite 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
S&F powder coated aluminium door and window shutter and frame any type (sliding or openable) and other similar work etc 60 micron powder coated section, fabricated by using the JINDAL / INDAL / HINDAL CO / CENTURIAN sections including all necessary roller wheels for window, cleats , handle, door stoper locking arrangement and arrangements to received glass/ prelaminated particle board with aluminium beading and stainless steel screw incl cost of rubber gasket beadings etc complete sealing between frame & wall with epoxy sealing compound. (The weight of rubber gasket beading will not be measured with the weight of aluminium shutters, glass and prelaminated particle board will be measured and paid seperately) All sections as approved by GE.
S&F Powder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including stranded aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick all as per manufacturer's instructions complete all as specified and directed
S&F butt hinges medium weight stainless steel 100mm size
Aluminium anodised, barrel tower bolts of extruded section and fixed 150mm size
Aluminium alloy, anodised, sliding door bolt 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F 4mm thick sheetglass ordinary quality exceeding 0.5 sqm each pane
Solar control film 50 micron reflective type mirror finish/mirror jet black type (gareware sun control or equivalent)
M&L Surface Excavation not exceeding 30 Cm deep and averaging 15 Cm deep and getting out in Soft/disintegrated rock
M&L Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point.
M & L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled layers not exceeding 15 cm thick, watered and rammed to a true surface.
M&L 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing
M&L screed bed or bedding layer of mortar 20 mm thick cement plaster 1:4 for laying floor finished to receive floor tiles.
M&L coloured heavy duty paving, chequered finish, cement concrete endura industrial tiles 12 to 15 mm thick (square /rectangular) textured series area of each tile exceeding 0.07 sqm not exceeding 0.18 sqm as in floors, treads and risers of steps fixed with grey cement and pigment laid over complete all as per manufacturer instructions and of design as directed by Engineer-in-Charge. Make Johnson endura industrial or equivalent of Kajaria/Regency
M&L PCC type B1 1:2:4 using 20 mm graded aggregate in kerbs
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L Excavating post holes or similar holes, each not exceeding 0.5 Cu. M, getting out in Soft/ disintegrated soil and removing surplus soil to a distance n.exc 50m & making good surface
M&L Plain Cement Concrete Type C2 1:3:6 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete.
S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam,tee, angle, channel or flat sections) confrming to Fe 410-W including cleats, distance pieces etc
M&L Preparation of new steel surfaces and applying two coats of epoxy anti corrossive paint over a coat of zinc primer.
S&F Fe-290 (Gde E-165) Rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, races etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F stainless steel glass railing of height 0.9 m with grade SST-316 including all accessories with 12 mm thick toughened glass and fitting to verandah,balconies etc all as per manufacturers instructions as directed by Engineer-in-Charge.
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with ANF (Board) edge tiles with Armstrong 24mm exposed grid. The tiles should have Humidity Resistance (RH) of 90%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 34%.The tile shall be laid on Armstrong Prelude38 with 24 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15.34Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. The Tile & Grid system used together should carry a 10 year warranty all as directed by Engineer
Writing 19 letters in 3D of stainless steel of height 75 cm in capital letter and fixing over finished surface all as specified and directed by Engr-in-charge.
PROVISION OF NEW ENTRANCE GATE ALONGWITH BOUNDARY WALL NEAR DSC POST AT NAY (GOA) UNDER AGE E/M – I. INTERNAL ELECTRIFICATION (E/M PORTION)
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium grade with all accessories of same grade fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing switch, socket, fan regulators etc for one light/fan/exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per item No 2.01 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed
M & L for surface point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium duty, with all accessories of same grade, fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
S & F modular Switch single pole one way 6 A, 240 V complete all as specified and as directed
S & F modular Switch single pole one way 16 A, 240 V complete all as specified and as directed
S & F Modular Socket outlet 2 in 1, 6 Amp , 240 volts, complete all as specified and as directed
S & F Modular Socket outlet 5A/16A, 5 in 1, 3 pin, flush type universal, 240 voltscomplete all as specified and as directed
S & F Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 volts complete all as specified and as directed
S & F stepped Modular electronic fan regulator flush type all as directed.
M & L DB with sheet metal enclousere 240 volts, 8 way with 200 Amp rated bus bar SPN double door type for MCBs incl mounting work as required in position complete all as specified and as directed
S & F MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
S & F MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
M & L for sub main wiring with two runs of single core 04 Sqmm FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC conduit medium grade of as required size (not less than 20 mm in width) with all accessories such as Tees, elbows, junction boxes etc, as required fixed concealed in wall along with one run of 4 Sqmm single core FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit)
S & F in repairs Energy efficient surface Mounted LED Luminire 20 watts 4' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr all as directed. Make : - Bajaj Cat No BCLSBAL 20W CW or equivalent in Philips/CG
M & L for ceiling fan AC single phase 230V of size 1200 mm sweep BEE 5 star rated and connecting up including provision of flexible copper wire three core of size 23/0.0076 from ceiling rose/PVC connector to ceiling fan all as specified.
M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
PROVISION OF NEW ENTRANCE GATE ALONGWITH BOUNDARY WALL NEAR DSC POST AT NAY (GOA) UNDER AGE E/M – I. EXTERNAL ELECTRIFICATION (E/M PORTION)
Supply and fix integral decorative LED 9 W bollard light with Die cast aluminium body opal white PC diffuser IP 54 protection including connections with 3 run of 2.5 Sq mm aluminium unsheathed wire multistranded from eletrical connection in junction boxes, complete on PCC block including making necessary complete all as specified and directed by Engineer-in-Charge. (Make:- Bajaj cat part No.BGBOM 650 9W LED WW or equivalent in Havells /Luker/CG)
Supply and fix LED post top made in die-cast aluminium housing with decorative clear opal acrylic diffuser with white powder coated aluminium reflector IP-65 protection of 40 watts capacity and including connections service wire with 3 run of 2.5 Sq mm aluminium unsheathed multistranded wire complete all as specified and directed by Engr-in-charge. (Make : Bajaj Cat No BGCT W4 LED WW or equivalent in Philips/Luker)
Supply and fix spike LED step light with die-cast aluminium housing designed for rugged outdoor uses & IP 65 protection of 12 watts capacity and including connections service wire with 3 run of 2.5 Sq mm aluminium unsheathed multistranded wire complete on PCC block including making necessary complete all as specified and directed by Engr-in-charge. (Make : Luker Cat No LSSPK12W WH, Blue, Green or equivalent in Philips/Wipro)
Supply and fix LED post top/wall light made in die-cast aluminium housing with decorative clear opal acrylic diffuser with white powder coated aluminium reflector IP-65 protection of 25 watts capacity and including connections service wire with 3 run of 2.5 Sq mm aluminium unsheathed multistranded wire complete all as specified and directed by Engr-in-charge. (Make : Bajaj Cat No BGCTN 25W LED WW or equivalent in Philips/Luker)
Supply, laying, testing and commissioning LT Cable XLPE insulated, galvanised steel strip armoured,1100 volts grade, multistranded aluminium conductor cable of cross sectional area 50 sqmm; 3.5 core conforming to IS:7098 part-I with latest amendments upto date and making cable connections by providing suitable aluminium lugs with proper crimping and steel glands and laid in trenches / ducts / floors / roofs or through pipes with saddles and fixing screws etc complete all as specified and directed . Note :- 1. Excavation, Concrete cable protection cover and Clear Sand for cushioning will be measured and paid separately. (b) Cost of glands, aluminium cable lugs (eye lid/barrel/bottle neck type/ring type or any shape) new nut, bolt and washers of required size/description are deemed to include in this rate.
All as per item No. 3.05 here in before but of size 2 core 10 sqmm
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated 3 core stranded copper conductor served with an inner sheathing of PVC tape PVC sheathed 2.5 sqmm nominal cross section in service connection/ light connections in garden light from juction box to fittings complete all as specified and directed by Engineer-in-Charge.
Supply and fix or laying in trenches PVC pipe heavy duty for cable protection/fixing of garden lights etc, of the following sizes including necessary tee/elbow/junction box etc. provision for cable entry if reqd in garden lights complete as required complete all as specified and directed by Engineer-in-Charge.
(b) 20 mm dia
Supply and fix or laying in trenches/on wall/poles/structures of GI tubing light grade for road crossing/for cable protection/fixing of wall lights etc,of the following sizes including necessary provision for cable entry if reqd in pigmi lights pole, fixing screws complete as required complete all as specified and directed by Engineer-in-Charge.
(a) 40 mm dia
Supply and fix MCCB 4 pole 415 volts with adjutable type 125 to160 Amps with breaking capacity 25 KA in outdoor type sheet steel enclosure with inclosure and including connecting of one incomming and three outgoing cables with suitable lugs, glands, nuts, bolts and washers all as specified and directed by Engineer-in-Charge. (Make :- L&T/ HPL/Havells)
Supply and fix Analogue type timer switch (Daily time switch) including power contactor 25 Amps, three phase, 415 volts and MCB TPN 32 Amps 10 KA 'C' series with arrangement of auto/mannual control switch duly prewired and bypass arrangement and including sheet metal enclosure of 2 mm thick CRCA sheet of adequate size with powder coated for enclosing the time switch with necessary fixing arrangements on PCC pole/wall surface by providing MS flat iron clamps 32x6 mm and nuts,bolts, washers etc complete all as specified and directed by Engineer-in-Charge. Make of Timer switch :- L&T/ GE / C&S Make of contactor :- Siemens / Legrand / L&T / HPL Make of MCB:- Havells/ Legrand / L&T / HPL
S & F in repairs Energy efficient LED street Light Luminaire 120 watts capacity comprises a die-cast aluminium housing and IP 65 protection, including connections with 3 run of 2.5 Sq mm aluminium unsheathed wire multistranded from LT over head line to the connector of fitting, connection wires not to be less than 2.5 metre in length duly run through GI bracket complete all as specified and directed by Engineer-in-Charge. (Make :- Bajaj Cat No BRTFG 120W LED CR or equivalent in Philips/ Wipro)
S & F in repairs Street light bracket made out of GI tubing 32/40 mm dia of approx 1.2 mtr length, light grade bend to shape suitable for security/street light/Pigmi light fittings with necessary fixing arrangements by using GI flat of 40 x 6 mm size including nut, bolt, washers etc complete all as specified and directed by Engineer-in-Charge.
Supply, erect and install in true vertical position prestressed concrete pole 09 metres long of size 102 x 172 mm at top and 102 x 279 mm at bottom, class10 including painting alternate strips of each 30 cm with black and yellow synthetic enamel paint up to 1.5 meters height from coping and the balance portion of pole shall be painted with two coat of cement based paint. The make of pole shall be as per approved makes of state electricity board complete all as specified and directed by Engineer-in-Charge. Note :- Excavation/Earth work, PCC foundation, pole coping shall be measured and paid separately
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work/using any description complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work/using as coping/any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs cable junction boxes IP 66 protected “halogen free and weather proof” suitable for out door type ( with metric knockouts for cable entry) of size 139 x 119 x 70 mm incl necessary suitable size new aluminium busbar single phase with neutral system mounted on saddles - 02 Nos of suitable length and thickness, provn of aluminium cable lugs for incoming & out going LT cable connections with junction box fixing clamps made up of MS flat, nut and bolt on poles/wall complete all as specified and directed by Engineer-in-Charge. Make : Sintex / Hensal or equivalent
M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 Mtr wide and n.exc 1.5 Mtr in depth in hard/dense soil getting out and levelling of bottom surface to required level for removing of old pipes or laying of pipeline all as specified.
Excavation in trenches not exceeding 1.5 Mtr wide and n.exc 1.5 Mtr in depth in soft/disintegrated rock getting out and levelling of bottom surface to required level for removing of old pipes/ laying of pipeline all as specified.
Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engineer-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard /dense soil all as specified.
Removing excavated material of any type of soil/soft rock from site to a distance not exceeding 50 Mtr away and depositing where directed not exceeding 1.5 Mtr above the starting point all as directed.
Supplying & Laying in trenches Clear Sand/m- Sand for cushioning under ground cable 8 cm below and 15 cm above complete all as specified and directed by Engineer-in-Charge. Note: Punned thickness only will be measured and paid.
Supplying & Laying precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in trenches for protect to under ground cable complete complete all as specified and directed by Engineer-in-Charge.
CVs CONSTRUCTIONS
K M SUBHANAIAH
M/S P S BABU
M/S DUBAL CONSTRUCTION
sapna enterprises
JINTECH
M/S jvsr constructions
Deepti Engineering Works
Super Construction
pk janardhanan
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .