Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 CrAccepted-AOC FL 404 4TH FLOOR MONT BLANC CHS LTD PLOT NO 138 SEC 13 KHARGHAR DIST RAIGAD NAVI MUMBAI 410 210 | RAIGAD | MAHARASHTRA | 410210 | ₹11.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹11.5 CrRejected-Finance FLAT NO S 2 SHRI CHINTAMANI S NO 1 1148 MAHAJAN PETH MODEL COLONY SHIVAJI NAGAR PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹11.5 Cr | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹12.9 CrRejected-Finance | ₹12.9 Cr | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹13.8 CrRejected-Finance | ₹13.8 Cr | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹13.8 CrRejected-Finance NOT SPECIFIED | ₹13.8 Cr | L5 | Rejected-Finance Other than L1 |
Tender Value
₹12.5 Cr
EMD Value
₹9.5 L
Closing Date
4 Mar 2023, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg CAMP, Pune PIN- 411001
PROVISION OF OTM ACCN FOR ASC TYPE D AT KIRKEE
2023_MES_572619_1
CA NO CEPZ/KKE/TOKEN-06 OF 2022-23
Open Tender
Civil Works
750 days
Kirkee
Class S category a(i)
Also refer NIT
8 documents required · 8 mandatory
₹3,000
GE MH RH Kirkee
₹9.5 L
Yes
31 Mar 2023
2 Jan 2023
6 Mar 2023
2 Jan 2023
4 Mar 2023
18 Feb 2023
3 Jan 2023 - 14 Jan 2023
Amount
SCH 'A' PART-I: BUILDING/STRUCTURES Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only
Construction of Block of Office and Administrative Accommodation with Parking all as shown on drawings and all as specified.
Construction of Block of Single Living Accommodation for 40 ORs, Cook House and Dinning hall all as shown on drawings and as specified.
Construction of Block of Officer Mess for 5 Officers all as shown on drawings and as specified.
Construction of Block of Stores for 96 Persons all as shown on drawings and as specified.
Construction of Block of JCO's Mess and Club all as shown on drawings and as specified.
Construction of Block of QTR Guard House and Ancillaries and Armouries/Kote including PCC hardstanding and flag staff with base all as shown on drawings and as specified.
Construction of Block of Duty Room/Guard Room all as shown on drawings and as specified.
Construction of Block of Single Living Accommodation for 2 JCOs including scooter shed all as shown on drawings and as specified.
Construction of Block of OR Institute (upto 500 men) all as shown on drawings and as specified.
Construction of Block of Tradesmen shops all as shown on drawings and as specified.
Construction of Block of Labourers Amenity Room all as shown on drawings and as specified.
Construction of Block of Scooter Shed for 40 Nos Scooters all as shown on drawings and as specified.
Construction of Block of Pump House all as shown on drawings and as specified. Note: Cable duct shall be measured and paid for separately under Provisional Sum.
Construction of UG Sump of 50000 litres capacity complete all as shown on drawing No. CEPZ/2022/KK/04/STR sheet 18/20 and as specified.
Construction of Static Water Tank of 50000 litres capacity complete all as shown on drawing No. CEPZ/2022/KK/04/STR sheet 19/20 and as specified.
Construction of Sentry Box Type-'A' complete all as shown in drawing No. CEPZ/91/TD/21M sheet 1/1 and as specified.
Construction of Fire Point complete all as shown in drawing No. CEPZ/94/TD/42 sheet 1/1 and as specified.
Construction of Garbage Bin all as shown in drawing No. CEPZ/97/TD/4 sheet 1/1 and as specified.
Construction of Incinerator all as shown in drawing No. CEPZ/91/TD/23M sheet 1/1 and as specified.
Construction of Septic tank for 50 users complete all as shown on drawing No. CEPZ/88/TD/17M sheet 1/4 to 4/4 and as specified.
Construction of Septic tank for 100 users complete all as shown on drawing No. CEPZ/88/TD/17M sheet 1/4 to 4/4 and as specified.
Construction of Soakage well of size 1.20 metre dia and 3.0 metre depth complete all as shown on drawing No. CEPZ/2019/TD/03 sheet 1/2 & 2/2 and as specified.
Total amount of Sch ‘A’ Part II (Internal Water supply)
Total amount of Sch ‘A’ Part III (Internal Electrification)
Total amount of Sch 'A' Part-IV (Road, Path, Hardstanding and Culvert)
Total amount of Sch ‘A’ Part V (Area drainage)
Total amount of Sch ‘A’ Part VI (Sewage Disposal)
Total amount of Sch ‘A’ Part VII (Solar Hot Water System)
Total amount of Sch 'A' Part-VIII (External Water Supply)
Total amount of Sch 'A' Part-IX (External Electric Supply)
Total amount of Sch 'A' Part-X (Compound Wall, Fencing and Gate)
Total amount of Sch 'A' Part-XI (Site clearance, excavation and earthwork)
NOTE: Schedule ‘A’ Part XII, Bidders shall insert their rate in Column-6 only and the Estimated rate indicated as "0.0" are for that purpose.
SCHEDULE 'A' PART-XII (MISC B/R AND E/M WORKS)
Supply , installing and commissioning of Water cooler, electric driven, single phase AC 230 Volts 50 Hz, fully stainless steel body of storage capacity 80 litres and cooling capacity 40 litres including connecting lead and suitable 3 pin plug top complete all as specified and directed. (Make:- Samsung / LG / Godrej / Whirlpool/ Blue Star/ Usha/ Voltas).
Supply , installing and commissioning of Refrigerator, electric driven, single phase AC 230 Volts 50 Hz of capacity not less than 310 litres, double door type, frost free, minimum BEE 3 star rated including connecting lead and suitable 3 pin plug top complete all as specified and directed. (Make:- Samsung / LG / Godrej / Whirlpool).
Supply , installing and commissioning of Refrigerator, electric driven, single phase AC 230 Volts 50 Hz of capacity not less than 195/200 litres, single door type, frost free, minimum BEE 3 star rated including connecting lead and suitable 3 pin plug top complete all as specified and directed. (Make:- Samsung / LG / Godrej / Whirlpool).
S&F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and design for input variation between 170 volts to 250 volts with output voltage stabilized at 230 volts with accuracy of ± 2.5 % of capacity 1.00 KVA including all fixing arrangement complete all as specified and directed.
Supply , installing, testing and commissioning of electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc. , including hot and cold water connection pipes and suitable 3 pin plug top 15 A capacity, complete all as specified and directed.
S&F Round shape Porch light LED fitting 15 watts 230 volts AC surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp, suitable for roof/ceiling including connecting with and including 3 core flexible copper conductor cable of suitable size complete all as specified and directed. (Make: Havells Cat Part No. LHEBABP51Z1 W015 / Bajaj Cat Part No. BPSLR-15W-LED WH RD SD / Crompton Cat Part No. LCRP-15-CDL or equivalent in makes as per Appendix 'C').
S&F LED light fitting 1 x 10 Watt bulk head luminaries including LED light, driver, holder including LED lamp and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. (Make: Havells Cat Part No. BIBWP 10W LED / Crompton Cat Part No. LBHP-10-CDL / Halonix Cat Part No. HLBH-21-10-CW or equivalent in makes as per Appendix 'C').
S&F LED light fitting 1 x 20 Watt, 230 Volts AC, decorative box type with driver holder including LED tube light and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. (Make: Havells Cat Part No. LUMILINEPLUSNEOBS 20WLED 865SPCSSIND / Halonix Cat Part No. HLB-03-20-CW-AL-SQ / Bajaj Cat Part No. BCLAB 20W LED P or equivalent in makes as per Appendix 'C').
S&F LED light fitting mirror type with high output diffuser 2 feet 1 x 10 Watt, 230 Volts AC, decorative type with driver holder including LED lamp and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. (Make: Havells Cat Part No. LUMILINEPLUSBS 10WLED 865SPCSS / Philips Cat Part No. BNO21 LED 12S6500PSUGR / Benlo Cat Part No. BL04BAT10WT5 or equivalent in makes as per Appendix 'C').
S&F LED light fitting, out door building security light of 20 Watt 240 Volts with high pressure die cast aluminium housing and heat resistant cover with driver, lamp bracket, impact and corrosion resistance including thermal management in multiple optics complete with IP 65/ 66 protection including bracket made of 32 mm dia GI tube light grade of 1 m length, bent to shape required including 2 Nos of flat iron brackets duly welded with nuts, bolts and washers etc., including electric connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. (Make: Halonix Cat Part No. HLSLD-14-20-CWDL-R / Benlo Cat Part No. BL18SL20W(ULT) / Bajaj Cat Part No. ENXTP 20LWH PO PC SD or equivalent in makes as per Appendix 'C').
S&F Ceiling fan complete with fan blades, down rod, electronic regulator and accessories, 230 Volts, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC), complete and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F Ceiling fan complete with fan blades, down rod, electronic regulator and accessories, 230 Volts, 1400 mm sweep, minimum air delivery 245 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC), complete and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
S&F Exhaust fan made from sturdy Engineering plastic, AC single phase, 230 Volts, 250 mm sweep with blades, frame, louvers and shutter including connecting with and including three core flexible copper cable of required length of size 23/0.0076 from ceiling rose/ connector to fan terminal, fixing the fan with suitable size of nuts, bolts, washers complete all as specified and directed. (Make: Bajaj Model No. Maxima DXI 250mm or equivalent in makes as per Appendix 'C').
S&F Exhaust fan, steel body heavy duty, AC 230 Volts, single phase, 380 mm sweep with blades, frame, louvers and shutter including connecting with and including three core flexible copper cable of required length of size 23/0.0076 from ceiling rose/ connector to fan terminal, fixing the fan with suitable size of nuts, bolts, washers complete all as specified and directed.
S&F Sheet metal enclosure VTPN as MCCB incomer and MCB SP outgoing 4 way 415 V AC double door surface / flush mounting made with CRCA sheet steel, powder coated IP-43 protection with and including isolated neutral bar, insulated bus bar assembly, complete all as specified and directed. (Make:-INDOASIAN Cat No. 811888 or equivalent in makes as per Appendix 'C').
S&F Sheet metal enclosure MCCB TPN for mounting of MCCB 415 V AC surface / flush mounting made with CRCA sheet steel, powder coated, complete all as specified and directed. (Make:-INDOASIAN Cat No. 811985 or equivalent in makes as per Appendix 'C').
S&F Sheet metal enclosure MCB SPN DB 6 way 230 V AC surface / flush mounting, double door, with 200 Amp rated bus bar, IP-43 protection, powder coated, complete all as specified and directed. (Make:-INDOASIAN Cat No. 811806 or equivalent in makes as per Appendix 'C').
S&F Moulded Case Circuit Breaker (MCCB) 4 pole 415 Volts 50 Hz of capacity 125 Amp with rupturing capacity 25 KA, Ics = 100% of Icu, suitable for VTPN DB as incomer with spreader terminal, complete all as specified and directed. (Make:-INDOASIAN Cat No. 840053 or equivalent in makes as per Appendix 'C').
S&F Moulded Case Circuit Breaker (MCCB) 4 pole 415 Volts 50 Hz of capacity 100 Amp with rupturing capacity 25 KA, Ics = 100% of Icu, suitable for VTPN DB as incomer with spreader terminal, complete all as specified and directed. (Make:-INDOASIAN Cat No. 840052 or equivalent in makes as per Appendix 'C').
S&F Moulded Case Circuit Breaker (MCCB) 4 pole 415 Volts 50 Hz of capacity 63 Amp with rupturing capacity 25 KA, Ics = 100% of Icu, suitable for TPN DB as incomer with spreader terminal, complete all as specified and directed. (Make:-INDOASIAN Cat No. 840050 or equivalent in makes as per Appendix 'C').
S&F Moulded Case Circuit Breaker (MCCB) 4 pole 415 Volts 50 Hz of capacity 40 Amp with rupturing capacity 25 KA, Ics = 100% of Icu, suitable for TPN DB as incomer with spreader terminal, complete all as specified and directed. (Make:-INDOASIAN Cat No. 840018 or equivalent in makes as per Appendix 'C').
S&F Moulded Case Circuit Breaker (MCCB) 4 pole 415 Volts 50 Hz of capacity 40 Amp with rupturing capacity 16 KA, Ics = 100% of Icu, suitable for TPN DB as incomer with spreader terminal, complete all as specified and directed. (Make:-INDOASIAN Cat No. 840018 or equivalent in makes as per Appendix 'C').
S&F Miniature Circuit Breaker (MCB) triple pole and neutral 415 Volts 50 Hz with rupturing capacity 10 KA, 'B' curve, fixed in MCB DB with connection, testing and commissioning, complete all as specified and directed for the following current carrying capacity:-
S&F Miniature Circuit Breaker (MCB) single pole and neutral 415 Volts 50 Hz of current carrying capacity 63 Amp with rupturing capacity 10 KA, 'B' curve, fixed in MCB DB with connection, testing and commissioning, complete all as specified and directed.
S&F Miniature Circuit Breaker (MCB) single pole and neutral 240 Volts 50 Hz of current carrying capacity 40 Amp with rupturing capacity 10 KA, 'B' curve, fixed in MCB DB with connection, testing and commissioning, complete all as specified and directed.
S&F Miniature Circuit Breaker (MCB) single pole and neutral 240 Volts 50 Hz of current carrying capacity 32 Amp with rupturing capacity 10 KA, 'B' curve, fixed in MCB DB with connection, testing and commissioning, complete all as specified and directed.
S&F Miniature Circuit Breaker (MCB) single pole and neutral 240 Volts 50 Hz of current carrying capacity 16 Amp with rupturing capacity 10 KA, 'B' curve, fixed in MCB DB with connection, testing and commissioning, complete all as specified and directed.
S&F Miniature Circuit Breaker (MCB) single pole 240 Volts 50 Hz of current carrying capacity 63 Amp with rupturing capacity 10 KA, 'B' curve, fixed in MCB DB with connection, testing and commissioning, complete all as specified and directed.
S&F Miniature Circuit Breaker (MCB) single pole 240 Volts 50 Hz of current carrying capacity 40 Amp with rupturing capacity 10 KA, 'B' curve, fixed in MCB DB with connection, testing and commissioning, complete all as specified and directed.
S&F Miniature Circuit Breaker (MCB) single pole 240 Volts 50 Hz of current carrying capacity 6 to 32 Amp with rupturing capacity 10 KA, 'B' curve, fixed in MCB DB with connection, testing and commissioning, complete all as specified and directed.
NOTE (For Item No. 12.15 to 12.30): All MCCBs and MCBs shall be of same make only)
S&F Sluice valve 80 mm bore long body, class PN-1, cast iron body with flanged ends as per IS : 1538 (FF) and drilled with forged stainless steel spindle, non rising type and cast iron wheel head, IS: 14846 marked including neoprene rubber gasket, nuts, bolts, washers etc. and fixed in position complete all as specified and directed.
S&F Valve, reflux, with by-pass arrangement , 50 mm dia/bore (NRV) for pump set and fixed in position complete all as specified and directed.
S&F Foot Valve conforming to IS: 4038, 63 mm dia/bore and fixed in position complete all as specified and directed.
Supplying, installing, testing and commissioning of Monoblock pumping set with induction motor of capacity 3.75 KW (5 HP) working on 3 phase 415 volts, AC supply coupled with pump having discharge between 5.1 LPS head 36 mtr head, suction size 65 mm, discharge size 50 mm, provision of air release valve complete all as per model No KDS- 538 + of Kirloskar make or equivalent in makes specified in Appendix 'C'; fixed on common base frame made out from MS structure with suitable PCC foundation complete all specified and directed.
M&L Cutting existing common header (MS) of size 300 mm dia pipe line at west side pump house in position for taking new branch pipeline connection for 80 mm dia GI pipe with tail pieces one side flanged and one side plain including necessary cutting, welding, gaskets, new tee branch piece reducing 300 dia to 80 mm branch connection including necessary excavation and earthwork and making good surfaces complete all as specified and directed.
M&L Construction of Fly ash bricks masonry valve pit chamber of size 0.60 m x 0.60 m x 0.60 m (depth) internal dimensions with 15 cm thick foundation using PCC 1:4:8 type D-2 over 15cm thick hard core, 23 cm thick fly ash brick wall built in cement and sand mortar 1:4, 15mm thick internal plaster including 50 mm thick PCC 1:3:6 bedding, 3mm thick MS sheet cover with 40mm x 40mm x6mm MS angle iron frame fixed in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) coping with 25mm x 6mm flat iron hold fast with handle and locking arrangement including necessary painting steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer, excavation, earth work, returning & filling in any type of soil and disposal of surplus soil at a distance of not exc. 50 m, complete all as specified.
INCOMING: MCCB TPN of capacity 32 Amps, 25KA -01 No. Ics = 100% icu.
OUTGOING: (a) MCB TPN, of capacity 16 Amps, 10 KA'B' curve -02 No.
(b) Complete power and control panel wiring with single core PVC insulated FRLS, multistranded copper conductor cable of size 2.5 /4.0 sq mm for MCB TPN, Starter, volt meter, Amp meter and indicating lamp for phase indication of ON/OFF indication complete. appropriate size for MCB TPN, Starter, volt meter, Amp meter and indicating lamp for phase indication of CN/OFF indication complete.
(c) Phase indicator LED based lamp in R,Y,B colours -01 set
(d) DOL starter with sheet metal enclosure complete with contactor and over load relay with range 6-12 Amp complete all as per L&T cat No SS 94351 - 2 Nos including suitable size of single core PVC insulated multi stranded Copper cable of size 4.0 sq mm from starter panel to motor terminal box complete all as directed.
M&L for road cutting for laying G.I. pipe for protection of cable upto depth of 90 cm including making good the disturbed road surfaces and redressing with filling plain cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregates complete all as specified and directed.
S&F Energy saving and environmental friendly long life LED street light fitting of 35/ 36 Watt 230 Volt, outdoor type, made up of high pressure die cast aluminium housing and heat resistant toughened glass cover with seal, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 with top opening driver cover and interchangeable driver for easy maintenance, electronic driver high efficiency longer life, protection against high serge, high / low voltage cut-off, open / short circuit protection and high power LED as lighting source including fittings & connecting new street light on pole bracket and PVC insulated cable with multistranded copper conductor of size 1.5 Sq.mm three core drawn through pole from pole junction box to street light fittings connector complete all as specified and directed. (Make: Halonix Cat Part No. HLSLD-14-36-CWDL-R / Havells Cat Part No. ENDURASUNDOWNSL 35WLED 765PASYBOPC / Bajaj Cat Part No. EXNT P35L WH PO PC SD or equivalent make given in Appendix 'C'.)
S&F Street light brackets made out of 40 mm dia GI light grade pipe duly bend by hot forging after filling of sand of length 1.50 metre including two pairs of MS flat iron strip 35 mm x 4 mm clamp of suitable size with necessary GI nuts, bolts - 02 Nos with flat washers 3 mm thick - 2 Nos including painting with aluminium paint over one coat of red oxide primer to the MS claps and bracket etc. complete and fixing on walls / poles complete all as specified and directed.
S&F Pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 250 x 200 x 105 mm (internal) comprising 01 No MCB single pole of capacity 6 Amp 240 Volts and one number heavy duty connector block of polycarbonate body with 4 terminals for loop in & loop out suitable for three phase street light system including nuts and bolts and connecting up complete with MS clap fabricated from 25 x 3 mm flat iron, nuts, bolts and washers etc. complete all as specified and directed.
Supply, install, testing & commissioning step down distribution transformer of capacity 200 KVA, outdoor type, energy efficient level-III confirming to Amendment No 1 Aug 2016 to IS: 1180 (Part-I) 2014, copper wound, HT-11 KV, 3 phase, LT- 433 Volts AC 3 phase 50 Hz, oil immersed, naturally air cooled. delta connected on primary side (11 KV HV side) and star connected on secondary side (433 V LV side) in accordance with vector group DYN 11 with neutral brought out on secondary LV side with tapping at ± 2.5% ± 5 % ± 7.5 % off load tap changer gear in steps of 2.5% including initial oil filling to appropriate level having dielectric breakdown strength ≥50 KV and all standard fittings a per IS: 1180 Part-I, 2014, mounted on and including PCC platform, fencing and steel gate as per TD Drg No CEPZ/98/TD/6. The unit rate of transformer shall include the following accessories / fittings / specifications:-
(a) Non detachable rating & terminal marking plates
(b) Lifting lugs for main tank and top cover.
(c) Earthing terminals with lugs - 02 Nos
(d) Thermometer pocket with cap along with dial type thermometer - 01 No
(e) Externally hand operated off circuit tap changing device with locking arrangement.
(f) Oil conservator tank with oil filling hole & cap and oil level gauge.
(g) Silica gel dehydrating breather with first charged silica gel.
(h) Top filler valve with plug.
(j) Drain cum bottom filter valve with plug.
(k) Air vent, explosion vent, fings etc.
(l) Unidirectional reversible roller - 04 Nos
(m) HV bushing - 03 Nos
(n) LV bushing - 04 Nos
(o) First fill oil.
(p) Base channel 100 x 50mm, 460 mm long with holes to make them suitable for fixing on a platform or plinth including making locking arrangement.
(q) First fill of fresh oil confirming to relevant IS and tested upto 50 KV dielectric strength.
(r) Extra bushing for neutral outside the L.T. cable box for providing independent earthing for neutral.
(s) Provision of two numbers danger boards 250 x 200 mm size made out of 1.6 mm this MS plate, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour, one at H.T. side and other on L.T. side.
(t) Any other fittings /accessories so as to confirm the whole transformer to IS:1180-2014.
NOTES:
i) Contractor shall submit technical, constructional and safety features drawings for approval of GE.
ii) Acceptance of transformer shall be subject to factory inspection for routine tests as per IS & ANSIC-57.12.90 (latest revision) in the OEM factory in presence of rep of Accepting Officer before dispatch from factory and Pre-commissioning tests after installation by SEI of Zone.
Blank
Supply and fix Gang operated air break switch of load disconnecting switch 11 KV 200 Amp with 12 insulators triple pole each pole consisting of galvanised steel base HT insulator as per BSS / SS non ferrous knife and screen loaded contact, arching arms of adequate section to break magnetising current tilting type complete with square shaft of GI, adequate length for phase separation, operating handle complete with locking arrangement with lock and key in both OFF and ON position, with suitable clamps nuts bolts complete for fixing only channel, making all electrical connection /jumpers with bottle lugs, commissioning and testing complete along with supply and fix new drop out expulsion fuse HT 11 KV rating of upto 50 Amp mounted on insulator and steel frame complete all heavy fuse barrel with fuse element complete set confirming to IS : 1818 as specified and as directed.
Supply install, testing and commissioning of automatic power factor correction panel of capacity 100 KVAR working on 415 volt, 50 HZ AC supply 3 phase, floor mounting cubical design, factory fabricated made out of 3 mm thick CRCA sheet, CPRI approved, duly powder coated, dust and vermin proof, provision for ventilation, angle iron frame support and base frame 100 mm height. Panel shall be 0f suitable size to accommodate the items mentioned below and having separate compartment /chambers for cable gallery bus bar switch dear etc. all as specified and comprising of the following:-
(a) MCCB 200 Amps, 4 pole, 25 KA, lcs =100% lcu, 415 volts AC - 01 Nos (Incomer)
(b) Copper bus bar of rating 200 Amp per Phase and 200 Amps per Neutral - 01 Set.
(c) APFC Relay, 8 Stages Micro processed based suitable for 415 V, 3 phase, AC supply - 01 No.
(f) Phase indicating lamp (Red, Yellow Blue) - 01 Set.
(h) Capacitor On/Off Indicating lamp LED type and push buttons - 08 Sets.
(j) Control wiring with 2.5 Sq.mm flexible copper conductor cables - 01 Job.
(k) Exhaust fan (Heavy duty) 230V, AC, 100 mm sweep with timer control - 02 Nos.
(l) Power wiring from bus bar to MCB and MCB to Capacitor back with suitable size of copper conductor cable of 4/6/10 Sq.mm as required.
(m) Capacitor Bank, MD XL type, 415 V, 50Hz, AC supply of following capacity:-
i) 25 KVAR - 02 Nos.
ii) 15 KVAR - 02 Nos.
iii) 10 KVAR - 01 No.
iv) 5 KVAR - 02 Nos.
(n) MCB TP, D Curve, 415 Volts 10 kA of following current rating:-
i) 63 Amp - 02 Nos.
ii) 32 Amp - 02 Nos.
iii) 25 Amp - 01 No.
iv) 10 Amp - 02 Nos.
(o) Power Contactors with 2 NO + 2 NO, 3 pole, 415Volts, 50 Hz, AC supply Capacitor duty MOC type suitable for following capacity of capacitors:-
i) 25 KVAR - 02 Nos.
ii) 15 KVAR - 02 Nos.
iii) 10 KVAR - 01 No.
iv) 5 KVAR - 02 Nos.
Supply, installation, testing and commissioning outdoor cubical feeder pillar box / LT Panel suitable for 3 phase 4 wire 415 volts 50 Hz system and size not less than 1.6 m x 1.3 m x 0.5 m, powder coated, weather, dust and vermin proof, factory fabricated, totally enclosed, front & rear opening doors type, IP-54 class protection, made out of 3.00 mm thick CRCA sheet metal outer and 2.0 mm thick for inner compartments conforming to IS: 8623, panel shall be of suitable size for housing bus bars, LT switchgears and measuring instruments, frame made out of MS angle iron frame made out of 50x50x6 mm cut to size, welded, bent to shape, cubical fabricated truly to box type, hinged panel board opening handles, locking arrangements, provided with sufficient circular holes at the bottom sheet for entry of plated cable glands and aluminium lugs suitable for incoming and outgoing cables, provided with PVC rubber bushes to spare holes, including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 volts grade IS 694 marked or PVC sleeved copper strips of appropriate sizes but not less than 2.50 Sqmm, including provision of PCC platform and grouting panel legs in PCC block so that the bottom of panel shall be at minimum 45 cm above ground level and 45 cm embedded in concrete, all accessories prewired complete with computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone and skull board with and including the following controls and accessories:-
(a) Aluminium bus bar 600 Amp capacity for Phase-R-Y-B and 600 Amps for neutral mounted on epoxy based insulator installed with coloured sleeves - 01 Set (3 Phase and 1 neutral)
(b) Incoming - 4 Pole MCCB 315 Amp, 50 Hz, 415 volt with rupturing capacity 35 KA with adjustable thermal and magnetic settings including connection, Ics = 100 % Icu - 01 No
(c) Outgoing- (i) MCCB, 4 Pole, 200 Amp adjustable type, Ics = 100 % Icu, 415 V, 50 Hz with breaking capacity 25 KA - 01 No (APFC Panel)
(ii) MCCB, 3 Pole, 160 Amp adjustable type, Ics = 100 % Icu, 415 V, 50 Hz with breaking capacity 25 KA - 01 No (Adm Block Panel 2)
(iii) MCCB, 3 Pole, 125 Amp adjustable type, Ics = 100 % Icu, 415 V, 50 Hz with breaking capacity 25 KA - 01 No (For FDB 4)
(iv) MCCB, 3 Pole, 100 Amp adjustable type, Ics = 100 % Icu, 415 V, 50 Hz with breaking capacity 25 KA - 01 No (For FDB 3)
(v) MCCB, 3 Pole, 40 Amp adjustable type, Ics = 100 % Icu, 415 V, 50 Hz with breaking capacity 25 KA - 01 No (For FDB 5)
(vi) MCCB TP 25 KA rupturing capacity 25 Amp adjustable type - 01 No (Pump house)
(ix) Phase indicating LED lamp (Red, Yellow Blue) - 01 Set.
(d) Panel wiring with suitable capacity of copper conductor cables of 1100 V grade.
(e) PCC foundation 1:3:6 type C-1 of suitable size as directed by Engineer-in-Charge.
NOTES:
(i) Panel shall be manufactured by the reputed manufacturer who is possession of type test certificate by CPRI not older than ten years.
(ii) Rate quoted shall be inclusive of complete excavation and earthwork in any kind of soil as per site requirement.
Supply, installation, testing and commissioning outdoor cubical feeder pillar box / LT Panel suitable for 3 phase 4 wire 415 volts 50 Hz system and size not less than 1.0 m x 0.8 m x 0.5 m, powder coated, weather, dust and vermin proof, factory fabricated, totally enclosed, front & rear opening doors type, IP-54 class protection, made out of 3.00 mm thick CRCA sheet metal outer and 2.0 mm thick for inner compartments conforming to IS: 8623, panel shall be of suitable size for housing bus bars, LT switchgears and measuring instruments, frame made out of MS angle iron frame made out of 50x50x6 mm cut to size, welded, bent to shape, cubical fabricated truly to box type, hinged panel board opening handles, locking arrangements, provided with sufficient circular holes at the bottom sheet for entry of plated cable glands and aluminium lugs suitable for incoming and outgoing cables, provided with PVC rubber bushes to spare holes, including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 volts grade IS 694 marked or PVC sleeved copper strips of appropriate sizes but not less than 2.50 Sqmm, including provision of PCC platform and grouting panel legs in PCC block so that the bottom of panel shall be at minimum 45 cm above ground level and 45 cm embedded in concrete, all accessories prewired complete with computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone and skull board with and including the following controls and accessories:-
(a) Aluminium bus bar 300 Amp capacity for Phase-R-Y-B and 300 Amps for neutral mounted on epoxy based insulator installed with coloured sleeves - 01 Set (3 Phase and 1 neutral)
(b) Incoming - 4 Pole MCCB 160 Amp, 50 Hz, 415 volt with rupturing capacity 35 KA with adjustable thermal and magnetic settings including connection, Ics = 100 % Icu - 01 No
(c) Outgoing- (i) MCCB, 3 Pole, 125 Amp adjustable type, Ics = 100 % Icu, 415 V, 50 Hz with breaking capacity 25 KA - 01 No (Adm Block)
(ii) MCB SPN, B Curve, 415 Volts 16 Amp, 10 kA - 02 Nos. (Parking & Guard Room)
BLANK
(vi) Phase indicating LED lamp (Red, Yellow Blue) - 01 Set.
(d) Panel wiring with suitable capacity of copper conductor cables of 1100 V grade.
(e) PCC foundation 1:3:6 type C-1 of suitable size as directed by Engineer-in-Charge.
NOTES:
(i) Panel shall be manufactured by the reputed manufacturer who is possession of type test certificate by CPRI not older than ten years.
(ii) Rate quoted shall be inclusive of complete excavation and earthwork in any kind of soil as per site requirement.
Supply, installation, testing and commissioning outdoor cubical feeder pillar box / LT Panel suitable for 3 phase 4 wire 415 volts 50 Hz system and size not less than 0.8 m x 0.7 m x 0.5 m, powder coated, weather, dust and vermin proof, factory fabricated, totally enclosed, front & rear opening doors type, IP-54 class protection, made out of 3.00 mm thick CRCA sheet metal outer and 2.0 mm thick for inner compartments conforming to IS: 8623, panel shall be of suitable size for housing bus bars, LT switchgears and measuring instruments, frame made out of MS angle iron frame made out of 50x50x6 mm cut to size, welded, bent to shape, cubical fabricated truly to box type, hinged panel board opening handles, locking arrangements, provided with sufficient circular holes at the bottom sheet for entry of plated cable glands and aluminium lugs suitable for incoming and outgoing cables, provided with PVC rubber bushes to spare holes, including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 volts grade IS 694 marked or PVC sleeved copper strips of appropriate sizes but not less than 2.50 Sqmm, including provision of PCC platform and grouting panel legs in PCC block so that the bottom of panel shall be at minimum 45 cm above ground level and 45 cm embedded in concrete, all accessories prewired complete with computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone and skull board with and including the following controls and accessories:-
(a) Aluminium bus bar 150 Amp capacity for Phase-R-Y-B and 150 Amps for neutral mounted on epoxy based insulator installed with coloured sleeves - 01 Set (3 Phase and 1 neutral)
(b) Incoming - 4 Pole MCCB 80 Amp, 50 Hz, 415 volt with rupturing capacity 25 KA with adjustable thermal and magnetic settings including connection, Ics = 100 % Icu - 01 No
(c) Outgoing- (i) MCCB, 3 Pole, 63 Amp adjustable type, Ics = 100 % Icu, 415 V, 50 Hz with breaking capacity 25 KA - 01 No (Officer Mess)
(ii) MCB TPN, C Curve, 415 Volts 16 Amp, 10 kA - 01 No. (For Street light)
(iii) MCB SPN of capacity 16 Amp - 02 Nos. (Labour amenity & Religious Hall)
(vi) Phase indicating LED lamp (Red, Yellow Blue) - 01 Set.
(vii) Astronomical time switch provided with 250 mA fuse unit externally at the input including power contactor ML 1.5, 3 pole with coil voltage 230 VAC for automatic street light On/ OFF fitted inside steel enclosure - 01 No.
(d) Panel wiring with suitable capacity of copper conductor cables of 1100 V grade.
(e) PCC foundation 1:3:6 type C-1 of suitable size as directed by Engineer-in-Charge.
NOTES:
(i) Panel shall be manufactured by the reputed manufacturer who is possession of type test certificate by CPRI not older than ten years.
(ii) Rate quoted shall be inclusive of complete excavation and earthwork in any kind of soil as per site requirement.
Supply, installation, testing and commissioning outdoor cubical feeder pillar box / LT Panel suitable for 3 phase 4 wire 415 volts 50 Hz system and size not less than 0.9 m x 0.8 m x 0.5 m, powder coated, weather, dust and vermin proof, factory fabricated, totally enclosed, front & rear opening doors type, IP-54 class protection, made out of 3.00 mm thick CRCA sheet metal outer and 2.0 mm thick for inner compartments conforming to IS: 8623, panel shall be of suitable size for housing bus bars, LT switchgears and measuring instruments, frame made out of MS angle iron frame made out of 50x50x6 mm cut to size, welded, bent to shape, cubical fabricated truly to box type, hinged panel board opening handles, locking arrangements, provided with sufficient circular holes at the bottom sheet for entry of plated cable glands and aluminium lugs suitable for incoming and outgoing cables, provided with PVC rubber bushes to spare holes, including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 volts grade IS 694 marked or PVC sleeved copper strips of appropriate sizes but not less than 2.50 Sqmm, including provision of PCC platform and grouting panel legs in PCC block so that the bottom of panel shall be at minimum 45 cm above ground level and 45 cm embedded in concrete, all accessories prewired complete with computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone and skull board with and including the following controls and accessories:-
(a) Aluminium bus bar 200 Amp capacity for Phase-R-Y-B and 200 Amps for neutral mounted on epoxy based insulator installed with coloured sleeves - 01 Set (3 Phase and 1 neutral)
(b) Incoming - 4 Pole MCCB 125 Amp, 50 Hz, 415 volt with rupturing capacity 25 KA with adjustable thermal and magnetic settings including connection, Ics = 100 % Icu - 01 No
(c) Outgoing- (i) MCCB, 3 Pole, 100 Amp adjustable type, Ics = 100 % Icu, 415 V, 50 Hz with breaking capacity 25 KA - 01 No (OR Accn)
(ii) MCCB, 3 Pole, 63 Amp adjustable type, Ics = 100 % Icu, 415 V, 50 Hz with breaking capacity 25 KA - 01 No (For Cook House and Dinning Hall)
(iii) MCB SPN, C Curve, 415 Volts 20 Amp - 04 No. (For Scooter shed, Store, Armoury & Ors Institute)
(vi) Phase indicating LED lamp (Red, Yellow Blue) - 01 Set.
(d) Panel wiring with suitable capacity of copper conductor cables of 1100 V grade.
(e) PCC foundation 1:3:6 type C-1 of suitable size as directed by Engineer-in-Charge.
NOTES:
(i) Panel shall be manufactured by the reputed manufacturer who is possession of type test certificate by CPRI not older than ten years.
(ii) Rate quoted shall be inclusive of complete excavation and earthwork in any kind of soil as per site requirement.
Supply, installation, testing and commissioning outdoor cubical feeder pillar box / LT Panel suitable for 3 phase 4 wire 415 volts 50 Hz system and size not less than 0.8 m x 0.8 m x 0.5 m, powder coated, weather, dust and vermin proof, factory fabricated, totally enclosed, front & rear opening doors type, IP-54 class protection, made out of 3.00 mm thick CRCA sheet metal outer and 2.0 mm thick for inner compartments conforming to IS: 8623, panel shall be of suitable size for housing bus bars, LT switchgears and measuring instruments, frame made out of MS angle iron frame made out of 50x50x6 mm cut to size, welded, bent to shape, cubical fabricated truly to box type, hinged panel board opening handles, locking arrangements, provided with sufficient circular holes at the bottom sheet for entry of plated cable glands and aluminium lugs suitable for incoming and outgoing cables, provided with PVC rubber bushes to spare holes, including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 volts grade IS 694 marked or PVC sleeved copper strips of appropriate sizes but not less than 2.50 Sqmm, including provision of PCC platform and grouting panel legs in PCC block so that the bottom of panel shall be at minimum 45 cm above ground level and 45 cm embedded in concrete, all accessories prewired complete with computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone and skull board with and including the following controls and accessories:-
(a) Aluminium bus bar 100 Amp capacity for Phase-R-Y-B and 100 Amps for neutral mounted on epoxy based insulator installed with coloured sleeves - 01 Set (3 Phase and 1 neutral)
(b) Incoming - 4 Pole MCCB 40 Amp, 50 Hz, 415 volt with rupturing capacity 16 KA with adjustable thermal and magnetic settings including connection, Ics = 100 % Icu - 01 No
(c) Outgoing- (i) MCB, TP, 32 Amp, Ics=100 % Ics, 415 V, 50 Hz with breaking capacity 10 KA - 02 Nos. (JCOs Mess)
(ii) MCB, TPN, 16 Amp capacity, 'C' curve 415 V, 50 Hz with breaking capacity 10 KA - 01 No (For Tradesman Shop)
(iii) MCB SPN, C Curve, 415 Volts 16 Amp - 02 No. (Spare)
(vi) Phase indicating LED lamp (Red, Yellow Blue) - 01 Set.
(d) Panel wiring with suitable capacity of copper conductor cables of 1100 V grade.
(e) PCC foundation 1:3:6 type C-1 of suitable size as directed by Engineer-in-Charge.
NOTES:
(i) Panel shall be manufactured by the reputed manufacturer who is possession of type test certificate by CPRI not older than ten years.
(ii) Rate quoted shall be inclusive of complete excavation and earthwork in any kind of soil as per site requirement.
S&F Health faucet brass chromium plated with 8 mm dia, 1 m long flexible tube chromium finish spring type & wall hook fixing to 15mm bore of pipe all as specified and directed.
S&F two way Bib tap 15mm chromium plated all as specified and directed.
M & L for providing pre cast RCC cable route indicator using M-25 (design Mix) concrete of height 800 mm x width 300 mm x thickness 120 mm duly reinforced having top circular section, provided with PCC 1:4:8 type D2 using 40 mm grade stone aggregate as in foundation of suitable size as director including engraving letters "MES 11 KV HT" on route indicator duly painted in synthetic enamel paint complete all as shown in drawing No CEPZ/2023/TD/01 sheet 1/1.
Provide Provisional Sum for : (a) Volley ball court as per drawing No. CEPZ/2018/TD/11 sheet 1/1 (b) Basket ball ground as per drawing No. CEPZ/2018/TD/10 sheet 1/1 (c) Cable duct in Pump house building
Horizon Construction
N. H. Saluji & Associates
K R TRADERS
United Sales Corporation
Sharda Infratech
Beejay Associates Contracts Pvt Ltd
V M MATERE INFRASTRUCTURES INDIA PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid