Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹32.4 LAccepted-Finance | ₹32.4 L | 1 | Accepted-Finance 1 |
| 2 | 2₹33.2 LRejected-Finance | ₹33.2 L | 2 | Rejected-Finance 2 |
| 3 | 3₹34.0 LRejected-Finance C 6 9 YAMUNA VIHAR DELHI 53 | NEW DELHI | DELHI | 110001 | ₹34.0 L | 3 | Rejected-Finance 3 |
Tender Value
₹36.7 L
EMD Value
₹73,500
Closing Date
27 Feb 2026, 3:00 pmClosed
EEE/KPZ
EEE/KPZ
Up gradation of storm water Pumps at Rana Pratap Bagh i/c Electrical Panel replacement, installation of APFC Panel, cables, rising main, suction and delivery pipe lines, provision of bar screen etc. as reqd
2026_MCD_267808_1
TC/ENGG./EEE/KPZ/2025-26/53.1
Open Tender
Electrical Works
90 days
EEE/KPZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹73,500
18 Mar 2026
18 Feb 2026
27 Feb 2026
18 Feb 2026
27 Feb 2026
18 Feb 2026
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.150 mm X 75 mm X 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 250 mm X 60 mm deep
Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator8 way, Double door
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 150mm widthx50mm depth x1.6 mm thickness
Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :150 mm dia
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
Supplying and fixing PVC batten/ angle holder including connection etc. as required.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Demolishing cement concrete manually/ by mechanical meansincluding disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
P & F of M.S. Bend with required nut bolts & packing sheet etc complete as required of following Dia:- 350 mm (8 mm thick),length 0.75 m
P & F of M.S. Blind Flange with required nut bolts & packing sheet etc complete as required of following Dia. 350 mm (25 mm thickness)
P & F of M.S. Flange with required nut bolts & packing sheet etc complete as required of following Dia:- 350 mm (25 mm thickness)
P& F/Replacement of M.S. black pipe (9.5 mm thickness) confirming to IS:3589 with required nut bolts & packing sheet etc. complete as required of following Dia. - 350 mm, 9.5 mm thick
SITC of Electrical Horizontal Centrifugal Pump Set with non clog impeller to handle storm/mixed/sewage water having minimum discharge of 350 m3/hr at head -15 Mtrs, RPM -1450 RPM (ind.) having suction and delivery size 150 mm dia mounted on a common base frame coupled with Min, 40 HP or suitable rating three Phase 415 volt, 50 Hz supply Electrical Motor completed as required M.O. C. as Packing, Gland casing- C.I.,Impeller C.I., Shaft 40 CB complete with tyre coupling , coupling guard and foundation bolts.
Providing & Fixing Auto transformer starter 50HP (without oil) conforming to ISS specification, tapping provided from 40, 60 & 80% of line voltage fitted with fix and moving contacts ETP grade copper to provide long life fitted with 3 magnetic overload relay of dash pot type adjustable from full load to twice of full load earthing terminal provided suitable for places where motor starting load is high etc. complete as required.
"SITC of Horizontal Centrifugal pump set with Non-clog solid handling impeller to handle storm/ mixed/ sewage water having minimum Discharge of 220 m3/hr at Head15 Mtrs, RPM - 1450 RPM (ind.) having suction and delivery size(125mm and 100 mm dia. respectively) mounted on a common base frame coupled with Min. 25 HP or suitable rating three phase, 415 volt, 50 Hz supply electrical Motor complete as required. M.O.C. as Packing: Gland Casing- CI, Impeller- CI, Shaft- 40C8 complete with tyre coupling, coupling guard and foundation bolts."
16 sq. mm lSI marked, FRLS PVC insulated, single core copper conductor cable
Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312 (Part 1 & 2), PN 1.6 complete as required (a) NRV 150mm
P& F/Replacement of M.S. black pipe (9.5 mm thickness) confirming to IS:3589 with required nut bolts & packing sheet etc. complete as required of following Dia. - 350 mm, 9.5 mm thick
P & F of M.S. Blind Flange with required nut bolts & packing sheet etc complete as required of following Dia. (a)80 mm (10 mm thickness)
Supplying fixing testing and commissioningof non rising spindle slucie valve of CI body with wedge bronze ring confirmoning to IS 14846 and SS , ISI 6603 marked complete PN 1.6 complete as required(a) 80mm
P & F of M.S. Bend with required nut bolts & packing sheet etc complete as required of following Dia:- 80mm short bend C Class
P & F of M.S. Bend with required nut bolts & packing sheet etc complete as required of following Dia:- 150 mm short bend C Class
P & F of M.S. flange with required nut bolts & packing sheet etc complete as required of following Dia:- 80mm ( 10 mm thickness)
P & F of M.S. flange with required nut bolts & packing sheet etc complete as required of following Dia:- 150 mm ( 10 mm thickness)
Providing and Fixing MS Black Pipe confirmoning to IS:- 3589 Gr 330 with packing sheets etc. as required of following dia 150 mm (5.4 mm thickness)
Providing and Fixing MS Black Pipe confirmoning to IS:- 3589 Gr 330 with packing sheets etc. as required of following dia 80 mm (4.85 mm thickness)
Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312 (Part 1 & 2), PN 1.6 complete as required (a) NRV 80mm
Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312 (Part 1 & 2), PN 1.6 complete as required (a) NRV 150 mm
Providing and fixing of 600 mm sweep Air circulator, complete with blades, jaal workable on 220/ 240 volts AC supply etc as reqd.
Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
Supplying, installation, Testing & Commissioning of 18-22 watt LED surface mounted Batten light of CRCA Sheet Body (Thickness ≥ 0.50 mm) material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineerin-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness ≥ 0.50 mm)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 250 A, 25 KA,TPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 400 A, 35 KA,TPMCCB
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Eligibility_criteria_Tender_Condition.pdf
Tender Documents • 0.68 MB
MCD_GCC_Circulars_2025.pdf
Tender Documents • 12.97 MB
BOQ_311467.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid