| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹35.2 LAccepted-AOC | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹45.0 L+₹7.6 L (20.3%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹50.0 L+₹12.7 L (33.9%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹53.3 L+₹15.9 L (42.6%)Rejected-Finance 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹68.1 L+₹30.8 L (82.3%)Rejected-Finance | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
4 May 2022, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
REPAIR AND MAINT OF UG CABLES, ACSR CONDUCTOR, POLES, LT DISTRIBUTION SYSTEM, SECURITY / STREET LIGHTS AND CONNECTED WORKS AT MIRAN SAHIB UNDER GE JAMMU
2022_MES_517454_1
GEJC-06/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹90,000
Yes
7 Jul 2022
9 Apr 2022
6 May 2022
9 Apr 2022
4 May 2022
22 Apr 2022
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep in any type of soil, getting out and levelling of bottom surface to required level for poles / stay assembly / cable complete all as specified and as directed.
Description same as per Ser Item No 1.00 here-in-before but exceeding 1.5 metre deep but not exceeding 3.0 metre deep complete all as specified and as directed.
Material and labour for road cutting, PCC hard standing as per site requirement including excavation for laying of GI pipe and making good the disturbed surfaces all as per existing surface complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25m thick complete all as specified and directed.
Removing excavated material from site to a distance not exceeding 50 metre away and depositing where directed not exceeding 1.5 metre from the starting point complete all as specified and as directed.
Material and labour in replacement of GI pipe light grade 80 mm bore for cable protection as a guard pipe complete all as specified and as directed.
Material and labour in replacment of GI pipe light grade 50 mm bore for cable protection as a guard pipe complete all as specified and as directed.
Supply and laying well burnt old size sub class 'B' bricks laid flat with width equal to length of brick perpendicular to the direction of cable, adjacent / abutting each other complete all as specified and as directed by Engineer-in-Charge in trenches over the cable for protection.
Supplying and laying in trenches clear sand for cushioning underground cable 8 cm below and 15 cm above complete in level all as specified and as directed.
Material and labour for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation of electric poles, struts, PCC blocks etc including necessary form work complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in foundation of assembly, bed concrete including necessary formwork and fair finish to exposed surfaces without using extra cement complete all as specified, struts, PCC blocks etc including necessary formwork complete all as specified and as directed.
Material and labour for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of poles and similar work including necessary formwork and fair finish to exposed surfaces without using extra cement complete all as specified and as directed.
Taking out old / unserviceable underground LT cables and connections including pipes, bricks or precast concrete cable cover etc from trenches / walls / poles of any cross sectional area and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from site complete all as specified and as directed.
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10 Sqmm, 2 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16 Sqmm, 2 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 35 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 50 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 70 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 95 Sqmm, 3.5 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing/connection, suitable thimble should be used as per site situation.
Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge. Note: - Wherever cable fixing/connection, suitable thimble should be used as per site situation.
Supply and fixing in replacement of 1100 Volt Arial bunched conductor having phase conductor of multistranded compacted circular aluminium conductor screen of extruded semi conducting compound, extruded XLPE insulated, insulation screen of extruded semi conducting compound over all metallic screen of copper tape extruded PVC type ST-2 sheathed twisted around bare aluminium alloy messenger generally as per IS-7098 Part-II of size 3 x 50 Sqmm + 1 x 50 Sqmm, 1 X 35 Sqmm and 1 X 16 Sqmm complete with dead end clamp, suspension clamp, eye hook, welding and cable jointing kit as per site requirement with the existing LT disribution system complete all as specified and as directed.
Dismantling / taking up of LT unserviceable pre-stressed concrete / steel poles of any size and shape and including taking out dismantled portion of poles embedded in ground after necessary demolition of concrete foundation and making good disturbed ground surface properly and disposal thereof complete all as specified and as directed by Engineer-in-Charge. Note: - Earth work for taking out of poles shall be measured and paid separately under relevant item of this Schedule.
Material and labour for steel tubular swagged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 meters long) including two coats of silver paint over a one coat of red oxide paint complete with strip of black and white strips having 30cm of width upto 1.5 metre height from top of coping all as specified and as directed including taking out old unserviceable PCC pole complete all as directed by Engineer-in-Charge. Note: - Excavation, foundation concrete, preservative treatment etc will be measured and paid separately.
Material and labour for pre-stressed concrete pole 9.0 metre long 102mm X 172 mm at top and 12 mm and 279 mm at bottom class 10 with strip of black and white strips having 30 cm of width upto 1.5 metre height from top of coping including taking out old unserviceale PCC pole complete all as specified and directed by Engineer-in-Charge.
Dismantling of ACSR conductors or disturbed span including line spacer and keeping serviceable materials in safe custody for re-use and unserviceable materials removing from the site(s) complete all as specified and as directed.
Labour for rectification of fault related ACSR jumpers, insulators binding wire by removing old one and replacement with new wire binding or rejumper as required etc complete all as specified and as directed. Note: - Material shall be measured and paid separately under supply only.
Supply and fixing ACSR conductor of any size and type from overhead HT / LT poles including binding at site to insulator with suitable size of binding wire etc including taking down existing worn out old broken ACSR conductor of any size and type and length at any position from LT / HT poles complete all as specified and as directed.
Fixing only by re-straining, tightening of ACSR conductors of any size / type on HT / LT poles including necessary new aluminium binding wire for fixing with insulator / PVC sleeves for jumper etc as required complete all as specified and as directed. Note: - Serviceable ACSR conductors shall be obtained from item No. 27 here-in-before.
Material and labour in replacement of galvanised steel wire 4.0 mm dia for continuous earth wire and cradles hexagonal / rectangular shall be provided and securely fastened to each pole and connected with earth ordinarily and cradle guarding where required complete including dismantling existing GI wire all as specified and directed.
Dismantling cross arms of mild steel channel or angle sections etc. and keeping serviceable materials in safe custody for re-use and / or unserviceable materials, removing from the site(s) complete all as specified and directed.
Material and labour in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections i.e. mild steel channel or angle sections etc. including new nuts, bolts, washers as required dia / length in size, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive one primer coat of red oxide, one under coat and one finishing coat of silver paint (1st quality) as required complete as specified and as directed.
Fixing only serviceable cross arm, mild steel channel, angle section obtained from item No 32 here-in-before as ordered and inclusive of one coat of aluminium paint including preparation of old steel surfaces complete all as specified and directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 120 Sqmm complete all as specified and as directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 70 / 95 Sqmm complete all as specified and as directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 50 Sqmm complete all as specified and as directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 35 Sqmm complete all as specified and as directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 25 Sqmm complete all as specified and as directed.
Supply and fixing in replacement of onload changeover switch AC-23 (side handle) in sheet metal enclosure of capacity 200 Amp, 415 Volts, 3 phase, four pole complete all as specified and as directed.
Dismantling LT stay assembly, of any size and unserviceable materials, removing from the site(s) complete all as specified and as directed. Note: - (a) Unserviceable stay assembly shall be taken off / dismantled at ground level and making good disturbed ground surface. (b) Earthwork for demolition of cement concrete shall be included in quoted rate.
Material and labour for stay assembly with accessories and GI stay rod 16 mm dia 1900 mm long, stay wire 7/4 mm stranded galvanised including mild steel stay plate 300 mm x 300 mm x 6 mm and galvanised thimble, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size with overall dimensions 90 mm x 140 mm clearance of hole 25.5 mm complete all as specified and shown in electrical plate No 01 of SSR Part - I including taking down old unserviceable stay assembly all as directed. Note: - Excavation, stay clamps and concrete work etc will be measured and paid separately.
Dismantling insulators, any type, any size and keeping serviceable materials in safe custody for re-use and / or unserviceable materials removing from the site complete all as specified and as directed.
Material and labour in replacement of insulator pin type, porcelain, vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 Volts grade complete all as specified and as directed.
Material and labour in replacement of insulator pin type, polymer composit material including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 Volts grade complete all as specified and as directed.
Fixing only serviceable pin type porcelain, vitreous, (white / brown or green) insulator for 1100 Volts grade of any type obtained from item No 43 here-in-before complete all as specified and as directed.
Material and labour in replacement of insulator shackle type, porcelain, vitreous, white, brown or green, shall be in one piece and shall have a groove on the side and a hole for a cotter pin and two galvanised bolts 12 mm dia and nuts with or without a pair of straps in size 31 x 3 mm as indicated size height 75 mm and dia 90 mm, for working pressure 1100 Volts complete as specified and as directed.
Fixing only serviceable shackle type porcelain, vitreous (white / brown or green) insulator of any size and shape for 1100 Volts grade obtained from item No 43 here-in-before complete all as specified and as directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 metre deep below normal ground level with top edge of the earth plate not less than 1.5 metre below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and including dismantling and taking down old unserviceable complete all as specified and as directed.
Supply and fix outdoor / indoor end termination joint heat shrinkable 1.1 KV grade cable complete with jointing material (Epoxy Based) and accessories suitable for 3½ or 4 core XLPE armoured aluminium conductor cable of size 10 to 50 Sqmm complete all as specified and as directed.
Supply and fix outdoor / indoor end termination joint heat shrinkable 1.1 KV grade cable complete with jointing material (Epoxy Based) and accessories suitable for 3½ or 4 core XLPE armoured aluminium conductor cable of size 70 to 150 Sqmm complete all as specified and as directed.
Supply and fix outdoor / indoor end termination joint heat shrinkable 1.1 KV grade cable complete with jointing material (Epoxy Based) and accessories suitable for 3½ or 4 core XLPE armoured aluminium conductor cable of size 185 to 300 Sqmm complete all as specified and as directed.
Supply and fix outdoor / indoor end termination joint heat shrinkable 1.1 KV grade cable complete with jointing material (Epoxy Based) and accessories suitable for 3½ or 4 core XLPE armoured aluminium conductor cable of size 400 Sqmm complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for 3½ or 4 core XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for 3½ or 4 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for 3½ or 4 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and as directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for 3½ or 4 core XLPE armoured aluminium conductor cable of size 240 to 400 Sqmm complete all as specified and as directed.
Supply and fixing PVC flat fibre separator for LT line 1100 Volt overhead conductor 3 / 4 / 5 wire system for maintaining horizontal spacing of conductor complete with nut and bolt in a span complete as specified and directed.
Supply and fixing in replacement insulation rubber matting sheet of size 1 metre x 2 metre x 10 mm conforming to ISI electric shock proof 1100 Volt grade complete all as specified and as directed.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 120 Sqmm, 3.5 core complete all as specified and as directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 150 Sqmm, 3.5 core complete all as specified and as directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 185 Sqmm, 3.5 core complete all as specified and as directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 240 Sqmm, 3.5 core complete all as specified and as directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 300 Sqmm, 3.5 core complete all as specified and as directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply only for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 400 Sqmm, 3.5 core complete all as specified and as directed by Engineer-in-Charge. Note: - Wherever cable fixing / connection, suitable thimble should be used as per site situation.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 400 Sqmm complete all as specified and as directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 300 Sqmm complete all as specified and as directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 240 Sqmm complete all as specified and as directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 185 Sqmm complete all as specified and as directed.
Labour for taking out all incoming / outgoing electric connection from LT panel / starter / motor / voltage stabilizer carefully for repair to cable / rectification the fault and re-connecting in position after repair and preparation the cable and fixing complete with nut, bolts, washers for cable size 120 to 400 Sqmm including preparation of 3.5 core cable, 4 wire each alongwith connected items like thimble, insulation tape and will be considerable in this job complete all as specified and as directed.
Supply and fixing in replacement, connecting and commissioning and testing of company make (automatic and manual operation) power factor improvement panel of capacity 30 KVAR for 63KVA Transformer including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor / Indoor) type panel factory made, weatherproof, dust and vermin proof (IP-54 / IP-42) suitable for 1100 V / 440 V grade 3 phase 50 Hz AC supply floor mounted, fabricated out of 14 SWG mild steel sheet and having four No's angle iron legs made out of 40 x 40 x 6mm 60 cm long angle iron below frame with front door and side / back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 Sqmm / extension strips and connected with suitable size thimbles, lugs duly painted with L&T grey epoxy powder coating after suitable chemical treatment, legs duly embedded in ground in PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting, with required sheet metal enclosures, thimbles, all as specified and directed by Engineer-in-Charge. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. The panels manufactured by original manufacturer only (dvepl, tricolite, L&T and Legrand) will be accepted and factory inspection will be done by GE / AGE at original manufacturer plant only.and all other electric incoming and outgoing connections with PVC insulated multistranded flexible copper cable of suitable size and PVC flexible conduit medium quality as required and comprising of the following: -
Incoming feeder: - (a) Incomer MCCB 100 Amp, Three Pole, Terminal based release with adjustable O/L, Adj S/C Setting Class II Front Face, 36 KA rupturing capacity, Ics=100%Icu, Isolation with positive break indication with double break contacts, standard extended rotary handle, spreaders, phase barrier. Make: - ABB / Schneider / L&T - 1 No. (b) Metering section - Digital Ammeter (0-200) Amps, Digital Volt Meter (0-500) Volts, RYB Indicating Lamps, 1 Set Control fuses, CT's - 3. (c) Insulated busbar of Aluminium of 125A capacity for 3 phase, fixed on insulators, busbar should be PVC sleeved with red, Yellow, Blue Colour, busbar support should be of Smc / Dmc - 1 set. (d) Multi 6 step 440 V, 5 A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display.
Outgoing feeder: - (e) Accessories for 1 KVAR Capacitor Bank - 1 No's: - Capacitor Duty Contactor 1 KVAR with Damping Resistors which limits in rush current 440 Volt, 3 phase, 50 Hz, coil - 220 VAC, MCB TP 6 A having breaking capacity 10 KA with standard duty capacitor, on/off indicators, Start / stop push button. Make: - Schneider / L&T / ABB. (f) Accessories for 2 KVAR Capacitor Bank - 2 No's: - Capacitor Duty Contactor 2 KVAR with Damping Resistors which limits in rush current 440 Volt, 3 phase, 50 Hz, coil - 220 VAC, MCB TP 16 A having breaking capacity 10 KA with standard duty capacitor on/off indicators, Start / stop push button. Make: - Schneider / L&T / ABB. (g) Accessories for 7 KVAR Capacitor Bank - 1 No's: - Capacitor Duty Contactor 7 KVAR with Damping Resistors which limits in rush current 440 Volt, 3 phase, 50 Hz, coil - 220 VAC, MCB TP 20 A having breaking capacity 10 KA with standard duty capacitor on/off indicators, Start / stop push button. Make: - Schneider / L&T / ABB. (h) Accessories for 10 KVAR Capacitor Bank -1 No's: - Capacitor Duty Contactor 10 KVAR with Damping Resistors which limits in rush current 440 Volt, 3 phase, 50 Hz, coil - 220 VAC, MCB TP 25 A having breaking capacity 10 KA with standard duty capacitor on/off indicators, Start / stop push button. Make: - Schneider / L&T / ABB. (j) Accessories for 5 KVAR Capacitor Bank - 2 No's: - Capacitor Duty Contactor 15 KVAR with Damping Resistors which limits in rush current 440 Volt, 3 phase, 50 Hz, coil - 220 VAC, MCB TP 16 A having breaking capacity 10 KA with standard duty capacitor on/off indicators, Start / stop push button. Make: - Schneider / L&T / ABB. (k) Accessories for 20 KVAR Capacitor Bank - 2 No's: - Capacitor Duty Contactor 20 KVAR with Damping Resistors which limits in rush current 440 Volt, 3 phase, 50 Hz, coil - 220 VAC, MCB TP 50 A having breaking capacity 10 KA with standard duty capacitor on/off indicators, Start/stop push button. Make: - Schneider / L&T / ABB. (l) Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230 VAC 1500 RPM, 160 cu.m/h flying leads.
(m) Automatic Power Factor controller steps relay micro processor based for switchting ON and OFF of capacitors to display of voltage, current, Active power, apparent power display of COS Ø, THD voltage, THD current, alarm indication for defective step, low power factor and excess temperature. The relay having volt free c/o contact, automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement. Switching programm : LIFO combi Filter, manual mode built in under and over voltage release with auto reset large voltage input band of 90 V to 400 volt, 45 to 65 HZ, current measuring 10MA-5A suitable for CT x / 1A and x / 5A commissioning without additional setting and programming. Three decimal power reading. Phasing out of fault capacitor bank Automatically. Make: -Schneider / Minitex / C&S. (n) All accessories prewired with suitable size copper wire with stand high temperature, housed in cubical panel made out of 14 swg thick mild steel sheet factory made duly powder coated front and rear door openable with locking arrangement complete with foundation as required or recommended by manufacturer. Make of APFC Panel: - Tricolitre, Dvepl, Legrand, L&T. Note: - APFC Panel shall be manufactured by original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. The panels manufactured by original manufacturer only (dvepl, tricolitre, L&T and Legrand) will be accepted and factory inspection will be done by GE / AGE at original manufacturer plant only.
Material and labour for replacement of old burnt out aluminium bus bar and connected link bar with proper colour coating with insulation tape of current rating 630 / 400 Amps including replacement of old rusted nut and bolts, washers complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement unserviceable indicators LED set of three pieces as per existing size and sample complete all as directed by Engineer-in-Charge.
Supply and fixing in replacement Ampere meter analog type 0-400 Amp CT with suitable set of size 96 Sqmm square type flush panel mounted complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement Volt meter analog type 0-500 Volt 96 Sqmm square type flush panel mounted complete all as specified and as directed by Engineer-in-Charge.
Material and labour for replacement of MCCB 3 Pole, current rating 100 Amp, thermal setting adjustable type 70%-100% rupturing capacity 16 kA at 415V, 50Hz complete all as specified and as directed.
Material and labour for replacement of MCCB 3 Pole, current rating 125 Amp, thermal setting adjustable 70%-100% rupturing capacity 16 kA at 415V, 50Hz complete all as specified and as directed.
Material and labour for replacement of MCCB 4 Pole, current rating 160 Amp, thermal setting adjustable 70%-100% rupturing capacity 36 KA at 415V, 50Hz complete all as specified and as directed.
Material and labour for replacement of MCCB 4 Pole, current rating 200 Amp, thermal setting adjustable 70%-100% rupturing capacity 36 KA at 415V, 50Hz complete all as specified and as directed.
Material and labour for replacement of MCCB 4 Pole, current rating 250 Amp, thermal setting adjustable 70%-100% rupturing capacity 36 KA at 415V, 50Hz complete all as specified and as directed.
Material and labour for replacement of MCCB 4 Pole, current rating 400 Amp, thermal setting adjustable 70%-100% rupturing capacity 36 KA at 415V, 50Hz complete all as specified and as directed.
Material and labour for replacement of MCCB 4 Pole, current rating 630 Amp, thermal setting adjustable 70%-100% rupturing capacity 50 KA at 415V, 50Hz complete all as specified and as directed.
Supply and fixing in replacement of onload changeover switch AC-23 (side handle) in sheet metal enclosure of capacity 100 Amp, 415 Volts, 3 phase, four pole complete all as specified and as directed.
Taking down unserviceable street / security light fitting of any type from the pole / building after disconnecting electric connection carefully complete all as specified and as directed. Note: - Repair / replacement of spares shall be measured separately.
Supply and fixing in replacement of distribution board with supply and fix time switches astro type (having longitude and latitude of Indian cities in memory) 250 V single phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete all as specified and as directed.
Supply and fixing in replacement of LED flood light fitting of capacity 200 Watt including inbuilt surge protection as per requirement LED flood light fittngs along with IP-65/66 protection complete all as specified and as directed.
Labour charges for repair / maint to old / unserviceable LED security / street / flood light / high mast light of any capacity including taking down existing fitting from pole / building for replacement of unserviceable driver, cable terminal block and connection wire and refixing the same in position after repair including testing all as specified and directed by Engineer-in-Charge. Notes: - (i) Spares shall be measured and paid separately under respective item. (ii) Sufficient Electrician and Helper shall be deputed daily to concerned sub division during office hours to ascertain the repairs to be carried out for lights under his area of residence. (iii) Electronic drivers, if required to be replaced shall be measured and paid separately as under relevant items of this BOQ as supply only. (iv) Necessary arrangements for carrying out repairs shall be undertaken by the contractor.
Supply and fixing in replacement of electronic driver of capacity 45 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of electronic driver of capacity 60 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of electronic driver of capacity 90 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of electronic driver of capacity 120 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of electronic driver of capacity 200 watt of existing make for LED Flood light fitting complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for servicing solar street light including cleaning of solar panels, checking and cleaning battery and all connection terminals, distilled water topup, solar battery charging controller, LED driver complete all as specified and directed.
Material and Labour for solar street light lead acid battery 12V, 75 AH, fixed as in repairs complete all as specified and directed.
Material and labour for MPPT Solar PWM controller suitable for battery sizes 12 / 24 / 36 / 48V, 40 / 60A including connection and testing, fixed as in repairs complete all as specified and as directed.
Supply and fixing in replacement of PVC insulated and sheathed cable of size 1.5 Sqmm 3 core aluminium conductor multistranded 1100 Volt grade 230 Volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement monocrystalline solar photovoltaic 12V, 180 W panel suitable for solar street light including fixing on existing mounting brackets with appropriate angle 45˚ to 60˚ to attain maximum efficiency including connecting and testing, fixed as in repairs, complete all as specified and as directed.
Supply and fixing in replacement fabrication bracket made out of GI tubing suitable for 45 / 60 / 90 watt LED light grade upto 1.2 metres length, bend to shape suitable for security light fitting with necessary mild steel clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc and including taking out unserviceable bracket and removing from site of work complete all as specified and as directed.
Supply and fixing in replacement SMC pole mounted box of size 250 X 200 X 100 mm with hinged door including clamp, nuts, bolts and washers complete all as specified and as directed and including following accessories: - (a) MCB SP 10 Amp, 10 KA 'C' series mounted on din rail-1 No. (b) Connector block suitable for 3 phase, 4 wire minimum 10 Sqmm cable - 1 No.
Supply and fixing in replacement LED solar street light fitting 12 watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and as directed. Note: - Excavation and earth work shall be measured separately.
M/s. Aggarwal Engineers
vishesh engineers
Prakash Trading Corporation
M/S Shiv Enterprises
Bidder Name
Prakash Trading Corporation
Sarbat Construction Co
M/S Shiv Enterprises
M/s. Aggarwal Engineers
vishesh engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .