| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC A T ROAD CHABUA DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹39.0 L+₹1.0 L (2.74%)Rejected-Finance VILLAGE GOROIMARI PO HALESWAR TEZPUR 784104 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784104 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹39.5 L+₹1.5 L (4.07%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹41.2 L+₹3.2 L (8.49%)Rejected-Finance A T ROAD CHABUA NEAR ST LUKAS HOSPITAL PO CHABUA DIST DIBRUGARH ASSAM 786 184 | CHABUA | DIBRUGARH | ASSAM | 786184 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹41.2 L+₹3.3 L (8.57%)Rejected-Finance NAV PUKHARI ROAD MILLAN PALLY PO DIST TINSUKIA ASSAM 786 125 | TINSUKIA | DIBRUGARH | ASSAM | 786125 | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
20 Feb 2025, 6:00 pmClosed
GE AF Chabua
Office of GE AF Chabua, pin-786102
As per BOQ details
2024_MES_684079_2
615/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Chabua
As per tender document
8 documents required · 8 mandatory
₹500
GE AF Chabua
₹70,000
Yes
25 Apr 2025
21 Jan 2025
22 Feb 2025
21 Jan 2025
20 Feb 2025
6 Feb 2025
Amount
M&L for dehydration & filteration of voltage stabilizer/isolation transformer oil by dehydration plant (bringing plant at site) including testing of sample before and after dehydration and filteration to achieved 40 KV at 2.5 mm gap complete all as specified and directed by Engr-in-ChargeNote : (i) The filteration of the voltage stabilizer /isolation transformer oil shall be carried out at different locations of the AF Stn Chabua. (ii) The report before filteration & after filteration to be submitted by contractor . (iii) Oil for topping up will be measured and paid separately. (iv) Centrifuging Machine with all T&P & testing eqpt required for dehydration to be arranged by contractor.
Supply & toping up of new voltage stabilizer/isolation transformer oil (in sealed barrel) conforming to IS 335 std having dielectric strength 40 KV at 2.5 mm gap after initial dehydration complete all as specified. Make : Savita/Castrol/Power True/Truoil.
Supply and fixing in repair digital voltmeter, ranging from 0 to 500 Volts, including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge.
Supply and fixing in repair digital ammeter, ranging from 0 to 400 Amps (with CT of suitable ratio), including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge.
S & F in repairs Indicator Lamps (LED type) including providing necessary electrical connections (to accommodate in panel board) complete all as directed by the Engr-in-Charge.
M & L for rewinding 433 Volts LV coils of voltage stabilizer/isolation transformer of using proper size super enameld copper wire suitable for working voltage 1.1 KV including three layer insulated material as per existing size of core including testing and commissioning complete all as specified and directed. NOTE :- i). Oil filtration,supply of new oil will be measured separately. ii). All petty parts including nut, bolts, gasket minor weldings are deemed to be included the rate quoted. iii). The rate for taking out,refixing after repair,both side transportation, lifting /unloading of voltage stabilizer/isolation transformer by crane /manual should be deemed to include in the rate quoted.
Dismantling and taking out old worn out reversible synchronus motor from the voltage stablizer and supply and fix reversible servo motor (3 Kgs.) with RC, single phase 230 Volts all as specified and directed.
Dismantling and taking out old worn out reversible synchronus motor from the voltage stablizer and supply and fix reversible servo motor (10 Kgs.) with RC, single phase 230 Volts all as specified and directed.
Dismantling and taking out old worn out reversible synchronus motor from the voltage stablizer and supply and fix reversible servo motor (20 Kgs.) with RC, single phase 230 Volts all as specified and directed.
Supply and fix in replacement of Transformer suitable for 50 KVA Servo voltage stabilizer all as specified and ditrected at site
Supply and fix in replacement of Transformer suitable for 60/63 KVA Servo voltage stabilizer all as specified and ditrected at site
Supply and fix in replacement of Transformer suitable for 100 KVA Servo voltage stabilizer all as specified and ditrected at site
Supply and fix in replacement of Transformer suitable for 200 KVA Servo voltage stabilizer all as specified and ditrected at site
Supply and fix in replacement of Transformer suitable for 300/315 KVA Servo voltage stabilizer all as specified and ditrected at site
Supply and fix in replacement of Transformer suitable for 500 KVA Servo voltage stabilizer all as specified and ditrected at site
Supply and fix in replacement of Transformer suitable for 630 KVA Servo voltage stabilizer all as specified and ditrected at site
Supply and fix in replacement of Dimmer suitable for 50 to 60 KVA Servo voltage stabilizer all as specified and ditrected at site
Supply and fix in replacement of Dimmer suitable for 100 KVA Servo voltage stabilizer all as specified and ditrected at site
Supply and fix in replacement of Dimmer suitable for 200 KVA Servo voltage stabilizer all as specified and ditrected at site
Supply and fix in replacement of Dimmer suitable for 300/315 KVA Servo voltage stabilizer all as specified and ditrected at site
Supply and fix in replacement of Dimmer suitable for 500 KVA Servo voltage stabilizer all as specified and ditrected at site
Supply and fix in replacement of Dimmer suitable for 630 KVA Servo voltage stabilizer all as specified and ditrected at site
Supply and fix in replacement of Dimmer suitable for 1000 KVA Servo voltage stabilizer all as specified and ditrected at site
Dismantling and taking out old worn out servo contro box from the voltage stablizer and supply and fix new Servo Control Box suitable for voltag stabilizer capacity up to 1000 KVA and testing complete all as specified and directed.
Dismantling and taking out defected PCB from the voltage stablizer and supply and fix new Servo circuit card (PCB) suitable for voltage stabilizer capacity up to 1000 KVA and testing complete all as specified and directed at site.
S & F in repairs carbon brush of voltage stabilizer complete all as specified and directed.
Supply and fix in replacement of 1 KVA ,single phase, Air cooled isolation transformer,Nos of phases- Single,Ratio- 1:1,Input voltage 240 V +/- 2.5%, Output voltage 240 V +/- 2.5 % complete all as specified and ditrected at site
M&L for spray painting of servo voltage stabilizer/isolation Transformer, preparation of old painted surfaces of steel body by brushing/cleaning stain, greasy spots with thinner outside of voltage stabilizer/Isolation transformer indoor/outdoor type capacity 10 KVA to 30 KVA to match with existing colour as per direction by Engr-in-Charge.
All as per ser item No 28 above nere-in-before but capacity of 50 KVA to 100 KVA
All as per ser item No 28 above nere-in-before but capacity of 200 KVA to 315 KVA
All as per ser item No 28 above nere-in-before but capacity of 500 KVA to 630 KVA
S & F in repair top cover gasket/cock sheet suitable for 10 KVA to 50 KVA Voltage Stabilizer/Isolation transformer complete all as specified and directed at site.
All as per ser item No 32 above nere-in-before but capacity of 60/63 KVA to 160 KVA
All as per ser item No 32 above nere-in-before but capacity of 200 KVA to 315 KVA
All as per ser item No 32 above nere-in-before but capacity of 500 KVA to 630 KVA
All as per ser item No 32 above nere-in-before but capacity of 1000 KVA
S & F in repairs control wiring of voltage stabilizer capacity of 200 KVA to 315 KVA complete all as specified and directed.
S & F in repairs main big gear of voltage stabilizer suitable for 200 KVA to 300 KVA complete all as specified and directed.
S & F in repairs high low voltage cut off circuit of voltage stabilizer complete all as specified and directed.
Singhs Construction (BID ID -3244535)
M/S Dee Dee Singhania & Sons (BID ID -3244107)
M/s Sashi Enterprise (BID ID -3244149)
M/s Pramillabh Construction (BID ID -3244118)
M/S RK Trading (BID ID -3244448)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .