Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance JOGI LANKAR RAINAWARI JOGI LANKAR RAINAWARI LANKAR RAINAWARI LANKAR RAINAWARI SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Finance | Not Admitted-Finance Others-Has quoted below 25% of estimated rates. Also, has submitted representation about wrongly quoting of rates in some items. |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
21 Apr 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, ED-3rd srinagar
Office of Executive Engineer, ED-3rd srinagar
Rate Contract for carrying out Restoration, Maintenance and HT-LT Network improvement Works for the year 2025-26 in respect of ESD Watalkadal, ED-3rd (Stage Contract)
2025_PDD_275010_1
ED-III /01 of 2025-26, Dated- 01/04/2025
Open Tender
Electrical Works
Item Rate
2 days
Office of Executive Engineer, ED-3rd srinagar
Refer SBD, Technical Drawings and Specification
7 documents required · 7 mandatory
₹500
Executive Engineer, ED-3rd srinagar
₹10,000
15 May 2025
1 Apr 2025
22 Apr 2025
1 Apr 2025
21 Apr 2025
10 Apr 2025
1 Apr 2025 - 18 Apr 2025
Amount
Supply & Installation of
11 Mtr ST Pole ST-410 SP56 S.T. poles well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above & bottom plate 35cm*35cm, 5mm thick fully welded.
9 Mtr ST Pole ST-410, SP-33 S.T. poles well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above & bottom plate 35cm*35cm, 5mm thick fully welded.
8 Mtr ST Pole ST-410, SP-15 S.T. poles well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above & bottom plate 35cm*35cm, 5mm thick fully welded.
9 Mtr. Long PCC Pole-WL-300Kg
8 Mtr. Long PCC Pole- WL-250Kg
Installation (including loading, unloading and transportation upto 4 Km from Divisional store to different sites (including Manual Carriage upto 100 Mtr at site)-Material to be provided Departmentally) of
11 Mtr ST Pole ST-410 SP56
9 Mtr ST Pole ST-410, SP-33
8 Mtr ST Pole ST-410, SP-15
9 Mtr. Long PCC Pole- WL-300Kg
8 Mtr. Long PCC Pole-WL-200Kg
Dismantling of damaged/Old Poles alongwith allied Materials and transportation of same to divisional store including loading and unloading
11 Mtr ST Pole
09 Mtr ST Pole
08 Mtr ST Pole
9 Mtr PCC Pole
8 Mtr PCC Pole
9/8 Meter Wooden poles along with Fixtures
Dismantling & re-erection of damaged/Old Poles alongwith allied Materials of same within the radius of 50 Mtrs of initial site
11 Mtr ST Pole
09 Mtr ST Pole
08 Mtr ST Pole
8 Mtr PCC Pole
9 Mtr PCC Pole
9/8 Meter Wooden poles along with Fixtures
Re- Straightening of Tilted Poles complete job
Manual Carriage Charges for Steel Tabular Pole 11Mtr/9mtr/8 mtr for every additional 50 mtr (including unloading/Loading)
Manual Carriage Charges for PCC 9mtr/8 mtr for every additional 50 mtr (including unloading/Loading)
Supply, laying and stringing of ACSR conforming with the Indian Standard specification IS: 398 (PLI)-1976 and IS : 398 (PL II)- 1976 or the latest version thereof.
30 Sqmm ACSR
50 Sqmm ACSR
100 Sqmm ACSR
Laying & stringing (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-(Material to be provided Departmentally) of ACSR conforming with the Indian Standard specification IS: 398 (PLI)-1976 and IS : 398 (PL II)- 1976 or the latest version thereof.
30 Sqmm ACSR
50 Sqmm ACSR
100 Sqmm ACSR
Dismantling of ACSR Conductor and transportation of same to divisional store including loading and unloading
30 Sqmm ACSR
50 Sqmm ACSR
100 Sqmm ACSR
Dismantling of ACSR Conductor & relaying/re-erection (including for re- Straightening of loose Conductor/Fallen Conductor after opening of bindings and refixing thereof).
30 Sqmm ACSR
50 Sqmm ACSR
100 Sqmm ACSR
Supply & Installation of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Supply, fabrication and fixing (including loading, unloading and transportation of Channel Iron X-arm/V cross Arm 100x50x50x6 mm,75x40x6mm (Galvanized as per IS) incluging Top Bracket, Clamps & Braces , (Galvanized as per IS)
Supply and Fixing of GI Pole Support Clamp including GI Nut and Bolts with washers.
11 Mtr Pole with size - 50x8x376 mm
9 mtr pole with size - 50x8x376 mm
8 mtr with size 50x 8x 332 mm
8 mtr or 9 mtr PCC with size 50x8x441mm
Supply and Fixing of Cable tie 4.8 x 250 mm (each packet contains 100 Nos.)
Supply and Fixing of Cable end caps
Supply & Installation of Insulating Piercing Connectors
Supply & Installation of 3 Phase SMDB (Service Main Distribution Box) IP54 made from 20 SWG CRCA MS sheetby Deep drawn method with connection terminals for R,Y, B & N as per specifications. Internal size of the box shall be 225mm x 285mm x 120mm used for connection through ABC line and for giving connections to the consumers 3phase-1 incoming 4 outgoing I/C- 1, O/G-2-4 (200 A, 0.415 kV) for RYB Phase. The DB should have Bottom entry of Cable with proper Glands/grommets-Safety Screws and Back Clamp suitable for 11/9/8 Mtr ST Pole or 9/8 mtr PCC poles with Nuts/bolts. The job also includes disconnection/reconnection of consumer energy meter including providing of aluminium lugs, if required.
Supply and fixing (including loading, unloading and transportation) of Nuts and Bolts full thread of sizes Galvanized as per IS
Supply & Installation (including loading, unloading and transportation) of 11KV Pin Insulators with Pins (5KN)
Providing and laying of earthing of earthing complete by GI Pipe 40 mm or GI rod 20 mm 2.5 mtr long through GI Strip
Providing and laying of Earthing of Substation---Excavation of earth pit of dia 650mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI strip for neutral earthing of size 25mm*3mm for connection of transformer body, G.O Set & lightening Arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials & earth chamber made of brick masonry with RCC slab cover.
Supply & Installation (including loading, unloading and transportation) of Danger Plate With Clamps as per Standards.
Supply & Installation (including loading, unloading and transportation) of GI Barbed Wire.
Supply & Installation (including loading, unloading and transportation) of Anti-Climbing Device with Clamps
Supply and Painting of ST poles with one coat of Red Oxide primer and two coats of Aluminum paint.
Installation of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Fabrication and fixing (including loading, unloading and transportation of Channel Iron X-arm/V cross Arm 100x50x50x6 mm/75x40x6mm (Galvanized as per IS) incluging Top Bracket, Clamps & Braces, (Galvanized as per IS) (Material to be Provided Departmentally including loading/ unloading/ transportation upto 4 Km from Divisional stores to different Sites)
Fixing of GI Pole Support Clamp including GI Nut and Bolts with washers for LT ABC Bare messenger with eye hook (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
11 Mtr Pole with size - 50x8x376 mm
9 mtr pole with size - 50x8x376 mm
8 mtr with size 50x 8x 332 mm
8 mtr or 9 mtr PCC with size 50x8x441mm
Fixing of Cable tie (each packet contains 100 Nos.) (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Fixing of Cable end caps (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Installation of Insulating Piercing Connectors (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Installation of 3 Phase SMDB (Service Main Distribution Box) IP54 made from 20 SWG CRCA MS sheetby Deep drawn method with connection terminals for R,Y, B & N as per specifications. The job also includes disconnection/reconnection of consumer energy meter including providing of aluminium lugs, if required. (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Fixing (including loading, unloading and transportation) of Nuts and Bolts full thread of sizes Galvanized as per IS (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Installation (including loading, unloading and transportation) of 11KV Pin Insulators with Pins (5KN) (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Laying of earthing of earthing complete by GI Pipe 40 mm or GI rod 20 mm 2.5 mtr long through GI Strip (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Installation (including loading, unloading and transportation) of Danger Plate With Clamps as per Standards. (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Installation of GI Barbed Wire (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Installation of Anti-Climbing Device with Clamps (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Painting of ST poles with one coat of Red Oxide primer and two coats of Aluminum paint. (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Providing of material and laying of Cement bottoming of poles
1:2:4 Mix as per REC Standards 0.66 M3 per Pole
1:2:4 Mix as per REC Standards 0.48 M3 per Pole
1:2:4 Mix as per REC Standards 0.40 M3 per Pole
Providing of material and laying of Stone pad (300x300x75 mm)
Supply & Installation (including loading, unloading and transportation) of 16 KN Polymer Shackle Insulator alongwith G.I. U-Clamps/pole collar for Shackle insulators
Supply and Fixing of PG Clamps for 30/ 50 mm² ACSR Conductor
Supply and Fixing of PG Clamps for 100 mm² ACSR Conductor
Supply and Fixing of PG Clamps for 150 mm² ACSR Conductor
Laying of Stone pad (300x300x75 mm) (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Installation (including loading, unloading and transportation) of 16 KN Polymer Shackle Insulator alongwith G.I. U-Clamps/pole collar for Shackle insulators (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Fixing of PG Clamps for 30 / 50 mm² ACSR Conductor (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Fixing of PG Clamps for 100 mm² ACSR Conductor (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Fixing of PG Clamps for 150 mm² ACSR Conductor (Material to be Provided Departmentally including loading/unloading/transportation upto 4 Km from Divisional stores to different Sites)
Supply, Laying & Installation of 11 kV, 3- Core XLPE flat strip Armoured, FRLS Cable
Laying & Installation of 11 kV, 3- Core XLPE flat strip Armoured, FRLS Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Dismantling of damaged/Old 11 kV, 3- Core XLPE Cable of different sizes and transportation of same to divisional store including loading and unloading
Dismantling & re-erection of damaged/Old 11 kV, 3- Core XLPE Cable of different sizes within the radius of 50 Mtrs of initial site
Supply, Laying, Installation of 11 kV, Single core Aluminium Flat strip Armoured XLPE Cable, FRLS
Laying, Installation of 11 kV, Single core Aluminium Flat strip Armoured XLPE Cable, FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Dismantling of damaged/Old 11 kV, 1- Core XLPE Cable of different sizes and transportation of same to divisional store including loading and unloading
Dismantling & re-erection of damaged/Old 11 kV, 1- Core XLPE Cable of different sizes within the radius of 50 Mtrs of initial site
Supply, Laying, Installation of 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
Laying, Installation of 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Dismantling of damaged/Old 3½ Core Cable,1.1kV Grade, Armoured, XLPE Cable of different sizes and transportation of same to divisional store including loading and unloading
Dismantling & re-erection of damaged/Old 3½ Core Cable,1.1kV Grade, Armoured, XLPE Cable of different sizes within the radius of 50 Mtrs of initial site
Supply, Laying, Installation of Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type including Lugs/Thimbles/Clamps
Laying, Installation of Single Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS type (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Dismantling of damaged/Old 1- Core Cable,1.1kV Grade, Armoured, XLPE Cable of different sizes and transportation of same to divisional store including loading and unloading
Dismantling & re-erection of damaged/Old 1- Core Cable,1.1kV Grade, Armoured, XLPE Cable of different sizes within the radius of 50 Mtrs of initial site
Supply, Laying, Installation of Single Core Cable,1.1kV Grade, Un-Armoured, XLPE Insulated Stranded Conductor FRLS type including Lugs/Thimbles/Clamps
Laying, Installation of Single Core Cable,1.1kV Grade, Un-Armoured, XLPE Insulated Stranded Conductor FRLS type (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Dismantling of damaged/Old 1- Core Cable,1.1kV Grade, Un-Armoured, XLPE Cable of different sizes and transportation of same to divisional store including loading and unloading
Dismantling & re-erection of damaged/Old 1- Core Cable,1.1kV Grade, Un-Armoured, XLPE Cable of different sizes within the radius of 50 Mtrs of initial site
Supply & Installation of HT Air Bundled Cable on ST/PCC Poles including Lugs/Thimbles/Clamps
35 mm² AB (HT) Cable (3x35+1x70 insulated) mm² XLPE (11 kV, 3C + Earth)
35 mm² AB (HT) Cable (3x35+1x35 mm² insulated) mm² XLPE
50 mm² AB (HT) Cable (3x50 + 1x70 insulated )mm² XLPE (11 kV, 3C + Earth)
70 mm² AB (HT) Cable (3x70+1x70 insulated)mm² XLPE (11 kV, 3C + Earth)
70 mm² AB (HT) Cable (3 x 70 + 1x95 insulated)mm² XLPE(11 kV, 3C + Earth)
95 mm² AB (HT) Cable (3x95+1x95 insulated)mm² XLPE(11 kV, 3C + Earth)
120 mm² AB (HT) Cable (3x120 + 1x95 mm²) XLPE(11 kV, 3C + Earth)
185 mm² AB (HT) Cable (3x185+1x120 insulated) mm² XLPE(11 kV, 3C + Earth)
Installation of HT Air Bundled Cable on ST/PCC Poles (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
35 mm² AB (HT) Cable (3x35+1x70 insulated) mm² XLPE (11 kV, 3C + Earth)
35 mm² AB (HT) Cable (3x35+1x35 mm² insulated) mm² XLPE
50 mm² AB (HT) Cable (3x50 + 1x70 insulated )mm² XLPE (11 kV, 3C + Earth)
70 mm² AB (HT) Cable (3x70+1x70 insulated)mm² XLPE (11 kV, 3C + Earth)
70 mm² AB (HT) Cable (3 x 70 + 1x95 insulated)mm² XLPE(11 kV, 3C + Earth)
95 mm² AB (HT) Cable (3x95+1x95 insulated)mm² XLPE(11 kV, 3C + Earth)
120 mm² AB (HT) Cable (3x120 + 1x95 mm²) XLPE(11 kV, 3C + Earth)
185 mm² AB (HT) Cable (3x185+1x120 insulated) mm² XLPE(11 kV, 3C + Earth)
Dismantling of damaged/Old HT Air Bundled Cable of different sizes and transportation of same to divisional store including loading and unloading
Dismantling & re-erection of damaged/Old HT Air Bundled Cable of different sizes within the radius of 50 Mtrs of initial site
Supply & Installation of LT Air Bundled Cable on ST/PCC Poles including Lugs/Thimbles/Clamps
35 mm² AB (LT) Cable ( 3 x 35 + 1 x 16 + 1 x 25 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 insulated)mm² XLPE (1.1kV, 3+1 C, Al)
70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 mm²) XLPE (1.1kV, 3+1 C, Al)
120 mm² AB (LT) Cable ( 3 x 120 + 1 x 25 + 1 x 95 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
185 mm² AB (LT) Cable ( 3 x 185 + 1 x 16 + 1 x 95 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
Installation of LT Air Bundled Cable on ST/PCC Poles (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
35 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 mm²) XLPE (1.1kV, 3+1 C, Al)
50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 mm²) XLPE (1.1kV, 3+1 C, Al)
70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 mm²) XLPE (1.1kV, 3+1 C, Al)
120 mm² AB (LT) Cable ( 3 x 120 + 1 x 16 + 1 x 70 mm²) XLPE (1.1kV, 3+1 C, Al)
185 mm² AB (LT) Cable ( 3 x 185 + 1 x 16 + 1 x 95 mm²) XLPE (1.1kV, 3+1 C, Al)
Dismantling of damaged/Old LT Air Bundled Cable of different sizes and transportation of same to divisional store including loading and unloading
Dismantling & re-erection of damaged/Old LT Air Bundled Cable of different sizes within the radius of 50 Mtrs of initial site
Providing and fixing of Aluminum Lugs/Thimbles of sizes
Fixing of Aluminum Lugs/Thimbles of sizes
Installation (including loading, unloading and transportation from one site to different sites (store/workshop/sites) upto the radius of 4 KM) (which includes arrangement of crane/sleepers/Trucks etc)
Dismantling of Distribution Transformer (including loading, unloading and transportation from one site to different sites (store/workshop/sites) upto the radius of 4 KM) (which includes arrangement of crane/sleepers/Trucks etc)
Installation of Distribution Transformer
Supply & Installation of LT Distribution Box for (As per the Specifications Enclosed).
25 kVA DTR with 40 Amp MCCB 3P 16 kA for incomer & 25 Amp MCCB 3P 16 kA/10 kA 1 No each (=2No.) for Outgoing Circuits.
63 kVA DTR with 100 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 1 No. and 63 Amp MCCB 3P 16 kA 1 No.s for Outgoing Circuits.
100 kVA DTR with 160 MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits
200 kVA DTR with 315 Amp MCCB 3P 25 kA for incomer & 160 Amp MCCB 3P 16 kA 3 No.s for Outgoing Circuits.
250 kVA DTR with 400 Amp MCCB 3P 36 kA for incomer & 200 Amp MCCB 3P 16 kA 1 No. and 160 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits.
400 kVA DTR with 630 Amp MCCB 3P (36 KA) adjustable 1 No. for incomer & 200 Amp 3 P (16 KA) 4 No.s fixed for Outgoing Circuits
630 kVA DTR with 1000 Amp MCCB 3P (36 KA) adjustable 1 No. for incomer & 250 Amp MCCB 3 P (25 KA) 2 No.s fixed & 200 Amp MCCB 3 P (25 KA) 3 No.s for Out going.
Supply & installation of LT Distribution Box for1600 Amp 4P ACB Drawal type , Breaking Capacity 50kA with enclosure
Supply & installation of LT Distribution Box for MCCB 630 Amp adjustable type 4P 36 KA with Box for 1 MVA DT
Installation of LT Distribution Box for (As per the Specifications Enclosed). (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally) of Distribution Transformer
25 kVA DTR with 40 Amp MCCB 3P 16 kA for incomer & 25 Amp MCCB 3P 16 kA/10 kA 1 No each (=2No.) for Outgoing Circuits .
63 kVA DTR with 100 Amp MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 1 No. and 63 Amp MCCB 3P 16 kA 1 No.s for Outgoing Circuits.
100 kVA DTR with 160 MCCB 3P 16 kA for incomer & 100 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits
200 kVA DTR with 315 Amp MCCB 3P 25 kA for incomer & 160 Amp MCCB 3P 16 kA 3 No.s for Outgoing Circuits.
250 kVA DTR with 400 Amp MCCB 3P 36 kA for incomer & 200 Amp MCCB 3P 16 kA 1 No. and 160 Amp MCCB 3P 16 kA 2 No.s for Outgoing Circuits.
400 kVA DTR with 630 Amp MCCB 3P (36 KA) adjustable 1 No. for incomer & 200 Amp 3 P (16 KA) 4 No.s fixed for Outgoing Circuits
630 kVA DTR with 1000 Amp MCCB 3P (36 KA) adjustable 1 No. for incomer & 250 Amp MCCB 3 P (25 KA) 2 No.s fixed & 200 Amp MCCB 3 P (25 KA) 3 No.s for Out going.
Installation of LT Distribution Box for 1600 Amp ACB Drawal type 36 kA with enclosure for 1 MVA DT (including loading, unloading and transportation from Divisional store to different sites-Material to be provided Departmentally)
Installation of LT Distribution Box for MCCB 630 Amp adjustable type 4P 36 KA with Box for 1 MVA DT (including loading, unloading and transportation from Divisional store to different sites upto 4 Km-Material to be provided Departmentally)
Supply & Installation of LT Fuse Set (Customised) for Distribution Transformers as per KPDCL Drawing no. CE/P&P/DRG/2023/LTFS/001 (enclosed)
Installation of LT Fuse Set (Customised) for Distribution Transformers (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Supply, fabrication and installation of Transformer Pad/G.I Channel Bedding including GI Pipe/Channels/Braces/ Clamps/Collars of sizes for Substations including frame for LA, GO etc
25 KVA- (250 Kg of GI includes Channels/Braces of sizes including Clamps /Collars)
63 KVA (300 Kg of GI includes Channels/Braces of sizes including Clamps /Collars)
100 KVA (300 Kg of GI includes Channels/Braces of sizes including Clamps /Collars)
200 KVA (300 Kg of GI includes Channels/Braces of sizes including Clamps /Collars)
250 KVA (300 Kg of GI includes Channels/Braces of sizes including Clamps /Collars)
400 KVA- (450 Kg of GI includes Channels/Braces/GI Pipes including Clamps /Collars)
630 KVA- (450 Kg of GI includes Channels/Braces/GI Pipes of sizes including Clamps /Collars)
1 MVA - (450 Kg of GI includes Channels/Braces/GI Pipes of sizes including Clamps /Collars)
Fabrication and installation of Transformer Pad/G.I Channel Bedding including GI Pipe/Channels/Braces/ Clamps/Collars of sizes for Substations including frame for LA, GO etc (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
25 KVA- (250 Kg of GI includes Channels/Braces of sizes including Clamps /Collars)
63 KVA (300 Kg of GI includes Channels/Braces of sizes including Clamps /Collars)
100 KVA (300 Kg of GI includes Channels/Braces of sizes including Clamps /Collars)
200 KVA (300 Kg of GI includes Channels/Braces of sizes including Clamps /Collars)
250 KVA (300 Kg of GI includes Channels/Braces of sizes including Clamps /Collars)
400 KVA- (450 Kg of GI includes Channels/Braces/GI Pipes including Clamps /Collars)
630 KVA- (450 Kg of GI includes Channels/Braces/GI Pipes of sizes including Clamps /Collars)
1 MVA - (450 Kg of GI includes Channels/Braces/GI Pipes of sizes including Clamps /Collars)
Supply & Installation of 11 KV Horn, Gap (fuse 3-phase 200A) as per Relevant IS
Installation of 11 KV Horn, Gap (fuse 3-phase 200A) as per Relevant IS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
Supply,Installation of Gapless Surge Arrestor, 9 KV, 10 KA, Lighting Arrestor Set Heavy duty with Polymer Housing, Station type conforming to IEC-99-4 Capable of withstanding Maximum continuous operating voltages (M.C.O.V)
Installation of Gapless Surge Arrestor, 9 KV, 10 KA, Lighting Arrestor Set Heavy duty with Polymer Housing, Station type conforming to IEC-99-4 Capable of withstanding Maximum continuous operating voltages (M.C.O.V) (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
Supply & Installation of 11KV 200 Amperes, Triple pole switches Gang Operated (G.O. Set) conforming: IS-2544, IS: 5340 (Part-III) and SS: 9921 (Part-I -V)
Installation of 11KV 200 Amperes, Triple pole switches Gang Operated (G.O. Set) conforming: IS-2544, IS: 5340 (Part-III) and SS: 9921 (Part-I -V) (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
Supply & Installation of Suspension/Tension Clamp with eye hook
Installation of Suspension/Tension Clamp with eye hook (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
Supply and Fixing of Mid Span Straight Through Jointing Kit for 11 kV ABC 50-95mm2
Supply and Fixing of Mid Span Straight Through Jointing Kit for 11 kV ABC 120-185mm2
Supply and Fixing of Straight Through Joints for Straight Through Jointing Kit for 70-120 mm², 11 KV Single Core Cable
Supply and Fixing of Straight Through Joints for Straight Through Jointing Kit for 150-185 mm², 11 KV Single Core Cable
Supply and Fixing of Straight Through Joints for Straight Through Jointing Kit for 240-300 mm² mm², 12 KV Single Core Cable
Supply and Fixing of Straight Through Joints for Straight Through Jointing Kit for 400-500 mm², 11 KV Single Core Cable
Supply and Fixing of Straight Through Joints for Straight Through Jointing Kit for 630-800 mm², 11 KV Single Core Cable
Supply and Fixing of Straight Through Jointing Kit upto 50-95 mm², 11 KV Three Core Cable
Supply and Fixing of Straight Through Jointing Kit upto 120-185 mm², 11 KV Three Core Cable
Supply and Fixing of Straight Through Jointing Kit upto 240-300 mm², 11 KV Three Core Cable
Supply and Fixing of Straight Through Jointing Kit upto 400- 500 mm², 11 KV Three Core Cable
Supply and Fixing of Straight Through Jointing Kit upto 25-50 mm², 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
Supply and Fixing of Straight Through Jointing Kit upto 70-95 mm², 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
Supply and Fixing of Straight Through Jointing Kit upto 120-150 mm², 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
Supply and Fixing of Straight Through Jointing Kit upto 185-240 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
Supply and Fixing of Straight Through Jointing Kit for 300 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
Supply and Fixing of Straight Through Jointing Kit upto 400 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
Supply and Fixing of Straight Through Jointing Kit upto 500 -630 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS
Fixing of Mid Span Straight Through Jointing Kit for 11 kV ABC 50-95mm2 (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Mid Span Straight Through Jointing Kit for 11 kV ABC 120-185mm2 (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Joints for Straight Through Jointing Kit for 70-120 mm², 11 KV Single Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Joints for Straight Through Jointing Kit for 150-185 mm², 11 KV Single Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Joints for Straight Through Jointing Kit for 240-300 mm² mm², 12 KV Single Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Joints for Straight Through Jointing Kit for 400-500 mm², 11 KV Single Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Joints for Straight Through Jointing Kit for 630-800 mm², 11 KV Single Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Jointing Kit upto 50-95 mm², 11 KV Three Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Jointing Kit upto 120-185 mm², 11 KV Three Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Jointing Kit upto 240-300 mm², 11 KV Three Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Jointing Kit upto 400- 500 mm², 11 KV Three Core Cable (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Jointing Kit upto 25-50 mm², 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Jointing Kit upto 70-95 mm², 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Jointing Kit upto 120-150 mm², 3½ Core Cable,1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Jointing Kit upto 185-240 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Jointing Kit for 300 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Jointing Kit upto 400 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Jointing Kit upto 500 -630 mm², 3½ Core Cable, 1.1kV Grade, Armoured, XLPE Insulated Stranded Conductor FRLS (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Supply & Fixing of Straight Through Cable Jointing Kit for50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
Supply & Fixing of Straight Through Cable Jointing Kit for 70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
Supply & Fixing of Straight Through Cable Jointing Kit for 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 25 + 1 x 95 insulated) mm² XLPE (1.1kV, 3+1 C, Al)
Fixing of Straight Through Cable Jointing Kit for 50 mm² AB (LT) Cable ( 3 x 50 + 1 x 16 + 1 x 35 insulated) mm² XLPE (1.1kV, 3+1 C, Al) (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Cable Jointing Kit for 70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 insulated) mm² XLPE (1.1kV, 3+1 C, Al) (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Straight Through Cable Jointing Kit for 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 25 + 1 x 95 insulated) mm² XLPE (1.1kV, 3+1 C, Al) (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Supply and Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 70 - 95 mm²
Supply and Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 120 mm²
Supply and Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 150 - 185 mm²
Supply and Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 240 - 300 mm²
Supply and Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 400 mm²
Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 70 mm² to 95 mm²
Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 120 mm²
Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 150 mm² to 240 mm²
Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 300 mm²
Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 400 mm²
Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 630 mm²
Supply and Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 800 mm²
Supply and Fixing of Heat Shrinkable Outdoor Cable Termination Kit for 11 kV ABC 50-95 mm²
Supply and Fixing of Heat Shrinkable Outdoor Cable Termination Kit for 11 kV ABC 120-185 mm²
Supply and Fixing of Heat Shrinkable End termination for 3½ C, 35-50 mm²
Supply and Fixing of Heat Shrinkable End termination for 3½ C, 70-150 mm²
Supply and Fixing of Heat Shrinkable End termination for 3½ C, 35-50 mm²
Supply and Fixing of Heat Shrinkable End termination for 3½ C, 35-50 mm²
Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 70 - 95 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 120 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 150 - 185 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 240 - 300 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of 11 kV Heat Shrinkable Outdoor Cable End termination for 3C, 400 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 70 mm² to 95 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 120 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 150 mm² to 240 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 300 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 400 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 630 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Heat Shrinkable Cable End termination kit for 11 kV 1C Cable 800 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Heat Shrinkable Outdoor Cable Termination Kit for 11 kV ABC 50-95 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Heat Shrinkable Outdoor Cable Termination Kit for 11 kV ABC 120-185 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Heat Shrinkable End termination for 3½ C, 35-50 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Heat Shrinkable End termination for 3½ C, 70-150 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Heat Shrinkable End termination for 3½ C, 35-50 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Fixing of Heat Shrinkable End termination for 3½ C, 35-50 mm² (including loading, unloading and transportation from Divisional store to different sites upto 4 KM-Material to be provided Departmentally)
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.
All kinds of soil
Ordinary Rock
Providing of Stone Soling (Supplying, Laying, spreading and compacting stone aggregate of 90 mm to 45 mm
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form work
Engaging labour for carrying out pruning/ branch cutting of trees
Unskilled
Semi-Skilled
Skilled
Installation (including Transportation, loading and unloading from Divisional store to different sites) of Single Phase Energy Meter including Clamps/Collar (Energy Meter to be provided Departmentally)
Installation (including Transportation, loading and unloading from Divisional store to different sites) of 3 phase Smart Energy Meter including Clamps/Collar (Energy Meter to be provided Departmentally)
Supply & Installation of 16 mm² Cable (2C) from LT Line to meter ,1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes
Supply & Installation of 10 mm² Cable (2C) from LT Line to meter ,1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes
Supply & Installation of 35 mm² Cable (2C) from LT Line to meter,1.1kV Grade, Armoured,XLPE Insulated Stranded Conductor FRLS type
Supply & Installation of 16 mm² Cable (4C) from LT Line to meter ,1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes
Supply & Installation of 10 mm² Cable (4C) from LT Line to meter ,1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes
Supply & Installation of 35 mm² Cable (4C) from LT Line to meter,1.1kV Grade, Armoured,XLPE Insulated Stranded Conductor FRLS type
Installation of 16 mm² Cable (2C) from LT Line to meter ,1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
Installation of 10 mm² Cable (2C) from LT Line to meter ,1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
Installation of 35 mm² Cable (2C) from LT Line to meter,1.1kV Grade, Armoured,XLPE Insulated Stranded Conductor FRLS type (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
Installation of 16 mm² Cable (4C) from LT Line to meter ,1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
Installation of 10 mm² Cable (4C) from LT Line to meter ,1.1k V Grade, Armoured, PVC Insulated Stranded Conductor FRLS type including Aluminum Lugs/thimbles of sizes (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
Installation of 35 mm² Cable (4C) from LT Line to meter,1.1kV Grade, Armoured,XLPE Insulated Stranded Conductor FRLS type (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally)
Supply and fixing of Mounting arrangement of Single Meter as per the KPDCL Approved drawing no. CE/P&P/Dwg./2023/LTMA/001, Dated : 10-04-2023
Supply and fixing of Mounting arrangement of Double Meters as per the KPDCL Approved drawing no. CE/P&P/Dwg./2023/LTMA/002 or 3, Dated : 10-04-2023
Supply and fixing of Mounting arrangement of Three Meters as per the KPDCL Approved drawing no. CE/P&P/Dwg./2023/LTMA/004, Dated : 10-04-2023
Supply and fixing of Mounting arrangement of Four Meters as per the KPDCL Approved drawing no. CE/P&P/Dwg./2023/LTMA/005, Dated : 10-04-2023
Supply and fixing of Polypropylene weather proof outdoor type Meter Box for Single Phase Meter along with Zinc plated clamps
Fixing of Polypropylene weather proof outdoor type Meter Box for Single Phase Meter along with Zinc plated clamps including loading and unloading from Divisional Stores to Different Sites
Supply and fixing of Polypropylene weather proof outdoor type Meter Box for Three Phase Meter along with Zinc plated clamps
Fixing of Polypropylene weather proof outdoor type Meter Box for Three Phase Meter along with Zinc plated clamps
Supply & Installation of Polypropylene weather proof outdoor type Meter Box for 4 Single Phase Meter along with Zinc plated clamps
Installation of Polypropylene weather proof outdoor type Meter Box for 4 Single Phase Meter along with Zinc plated clamps including loading and unloading from Divisional Stores to Different Sites
Transportation charges for material (including ST/PCC Poles/ACSR/DT etc) beyond 4 Km from store to different sites
Hiring the vehicle (Pick Up etc) for whole day (fuel to be provided departmentally) for Carriage/Transportion of Material including loading and unloading from Divisional Stores to Different Sites or From one location to another.
Supply & Installation of 11kV Pilfer resistant metering cubicle for 3phase 4 wire metering system made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Panel having two compartments upper Meter compartment and lower CT/PT compartment. Provided with synthetic or semi synthetic gasket firmly glued to the sufrace, Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangments. The metering panel shall be provided with two No MS channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening the LV chamber door.
Supply & Installation of Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5. The CT ratio shall be as under:
2.5 /5 for 25kVA DT
5/5 for 63kVA DT
7.5/5 for 100 kVA DT
15/5 for 200 kVA DT
20/5 for 250 kVA DT
25/5 for 400 kVA DT
50/5 for 630 kVA DT
75/5 for 1 MVA DT
Supply & Installation of 11kV/ 110 V, Three phase epoxy resin cast PT with rated burden 15VA per phase and accuracy class 0.5 or better and conforming to IS:3156 (part-I&II) amended upto date with proper colour coded identification. PTs shall be of uniform insulating and withstand separate source 23kV pf for one minute.
Supply and Fixing of Bus Bar details:CTs bus bar:- 40x6 mm copper strip or adequate size PTs bus bar: Copper wire 8 SWG or 30x0.6mm copper flat strip to connect PT terminal or adequate size duly insulated by the monoplast tape
Supply & Installation of PVC Copper wire flexible multi-strand of required size for secondary connections for CT wiring the minimum wire size shall be 4 mm2 (RYB) and for PT wiring minimum wire size shall be 2.5 mm2 (RYB).
Supply and fixing of Copper Lugs preferably ring type duly crimped for termination of wires and tapes
Supply and fixing of Grounding bus of minimum 40mm copper, 25cm long fixed to the unit in HV chamber. TheCTs, PT meter and 11kV Cable sheath shall be grounded to the bus through groundingwire (green) of min size 10mm2
Supply & Installation of 3Ph, 3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energymeters DLMS CompliantCategory 'C' with RS232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) metersfor measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc. (make L&T, Secure,ABB)
Supply and fixing of Independent flexible PVC pipes for CT wiring and PT wiring of appropriate size from HTcompartment to meter compartment
Supply and fixing of Pedestal made out of MS Channel of size 75 x 40 mm or angle iron of size 65 x 65 x 5 mm,duly painted as per site requirement for mounting of metering panel including concretefoundation wherever required including cost of nuts and bolts
Supply and fixing of 3 Core 11 kV Aluminium cable XLPE armoured 35 mm2 including cost of clamp for its fixingwhere ever required.
Supply and fixing of Cable termination kits suitable for 3 x 35 mm2 XLPE Cable(indoor/outdoor)
Installation of 11kV Pilfer resistant metering cubicle for 3phase 4 wire metering system made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Panel having two compartments upper Meter compartment and lower CT/PT compartment. Provided with synthetic or semi synthetic gasket firmly glued to the sufrace, Dust, weather and Vermin proof and shall comply degree of protection IP 65 both the chambers having one sided hinged door arrangments. The metering panel shall be provided with two No MS channels of size 100 x 50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening the LV chamber door. (Including unloading/loading/transportation from store to site)
Installation of Single Phase, Single core, single ratio, Epoxy resin Cast Current Transformers suitable for 11kV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part-I & II) amended upto date. ISF shall be upto 5The CT ratio shall be as under:(Including unloading/loading/transportation from store to site)
2.5 /5 for 25kVA DT
5/5 for 63kVA DT
7.5/5 for 100 kVA DT
15/5 for 200 kVA DT
20/5 for 250 kVA DT
25/5 for 400 kVA DT
50/5 for 630 kVA DT
75/5 for 1 MVA DT
Installation of 11kV/ 110 V, Three phase epoxy resin cast PT with rated burden 15VA per phase and accuracy class 0.5 or better and conforming to IS:3156 (part-I&II) amended upto date with proper colour coded identification. PTs shall be of uniform insulating and withstand separate source 23kV pf for one minute. (Including unloading/loading/transportation from store to site)
Fixing of Bus Bar details:CTs bus bar:- 40x6 mm copper strip or adequate size PTs bus bar: Copper wire 8 SWG or 30x0.6mm copper flat strip to connect PT terminal or adequate size duly insulated by the monoplast tape (Including unloading/loading/transportation from store to site)
Installation of PVC Copper wire flexible multi-strand of required size for secondary connections for CT wiring the minimum wire size shall be 4 mm2 (RYB) and for PT wiring minimum wire size shall be 2.5 mm2 (RYB). (Including unloading/loading/transportation from store to site)
Installation of 3Ph, 3 Wire HT CT/PT operated Fully static Smart Tri-Vector Energymeters DLMS CompliantCategory 'C' with RS232 port for modem compatibility. 11kV/110V, Ph-Ph (3P,3W) metersfor measurement of different electrical parameters including Active Energy (kWh/ MWh), Reactive Energy (kVArh/MVArh), Apparent Energy (kVAh/ MVAh) etc. (make L&T, Secure,ABB) (Including unloading/loading/transportation from store to site)
Laying, Installation of 3 Core 11 kV Aluminium cable XLPE armoured 35 mm2 including cost of clamp for its fixingwhere ever required. (Including unloading/loading/transportation from store to site)
Fixing of Cable termination kits suitable for 3 x 35 mm2 XLPE Cable(indoor/outdoor) (Including unloading/loading/transportation from store to site)
Supply & Installation of 11 KV Link Set
Installation of 11 KV Link Set (Including unloading/loading/transportation from store to site)
Supply & Installation of G.I Mukey for Shackle Insulators with bolt of (50x6)mm
Installation of G.I Mukey for Shackle Insulators with bolt of (50x6)mm (Including unloading/loading/transportation from store to site)
Supply & Installation of G.I Pole Collars for different sizes
Installation of G.I Pole Collars for different sizes
Supply & Installation of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Installation of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally
Supply & Fixing of GI Wire 6 SWG & 8 SWG
Fixing of GI Wire 6 SWG & 8 SWG (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally
Supply & Fixing of GI Strip
Fixing of GI Strip (including loading, unloading and transportation from Divisional store to different sites upto 4 KM -Material to be provided Departmentally
Dismantling of iron of sorts and transportation of same to divisional store including loading and unloading
Disconnection of Power Connections of Energy Meter(1 Phase / 3 Phase)/MSD Box from Bare Conductor and reconnection to LT AB Cable by use of Piercing Connectors (Piercing connectors to be provided separately)
Relocation of Energy Meters (1 Phase / 3 Phase) (Smart/Conventional) from one Pole to another complete job.
Connecting of Energy Meters (Smart/Conventional) to MSD Box including Lugs/thimbles/nuts/bolts
Supply & Installation of MCB's "C" Curve
Installation of MCB's "C" Curve (Material to be provided Departmentally)
Supply & Installation of MCCB's
40/63/100 Amps,36 kA, 4P adjustable
160 Amps, 36 kA, 4P adjustable
200 Amps, 36 kA, 4P adjustable
250 Amps, 36 kA, 4P adjustable
400 Amps, 36 kA, 4P adjustable
630 Amps, 36 kA, 4P adjustable
Installation of MCCB's (Material to be provided Departmentally)
40/63/100 Amps,36 kA, 4P adjustable
160 Amps, 36 kA, 4P adjustable
200 Amps, 36 kA, 4P adjustable
250 Amps, 36 kA, 4P adjustable
400 Amps, 36 kA, 4P adjustable
630 Amps, 36 kA, 4P adjustable
Boring by HDD Drilling
Supply and laying of HDPE Pipe including excavation, Back filling and laying
Outer Dia 180 mm Inner Dia 152 mm
Outer Dia 160 mm Inner Dia 148 mm
Outer Dia 120 mm Inner Dia 108 mm
Outer Dia 90 mm Inner Dia 78 mm
Outer Dia 50 mm Inner Dia 38 mm
Supply and laying of HDPE Pipe
Outer Dia 180 mm Inner Dia 152 mm
Outer Dia 160 mm Inner Dia 148 mm
Outer Dia 120 mm Inner Dia 108 mm
Outer Dia 90 mm Inner Dia 78 mm
Outer Dia 50 mm Inner Dia 38 mm
SOLARCITY ELECTRICALS AND SUPPLIERS (BID ID -2358515)
M/S GM ELECTRICALS AND MECHANICAL (BID ID -2358303)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .