Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹44.3 L+₹1.1 L (2.63%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹63.9 L+₹20.7 L (47.9%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹64.5 L+₹21.3 L (49.4%)Rejected-AOC 94 D POCKET J AND K DILSHAD GARDEN DELHI DELHI 110095 UDYAM DL 02 0018675 07AHCPD1811D1Z7 B R | SHAHDARA | DELHI | 110095 | L4 | Rejected-AOC L4 | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Hard copy of the following are not submitted by the agency
1 Tender fee/MSME etc. 2. Declaration of EMD as per Proforma Annexure “Câ€of NIT 3. Unconditional acceptance
As per NIT clause 5 (vi) vide page no. 5&6 agency tender is hereby rejected. |
Tender Value
Refer Docs
Closing Date
21 Sept 2021, 6:00 pmClosed
MANAGER EE
IAA VASANT KUNJ NEW DELHI
Annual Maintenance Contract of 11KV 415V Substation Equipment ic Operation and Maintenance of the complete power supply system at Indian Aviation Academy and Hostel block of Indian Aviation Academy Vasant Kunj New Delhi
2021_AAI_87654_1
IAA/Engg.(E)/NIT/AMC/ Power-House/2021-22
Open Tender
Electrical Works
Item Rate
730 days
IAA VASANT KUNJ NEW DELHI
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
INDIAN AVIATION ACADEMY NIAMAR SOCIETY
Exempted
22 Dec 2021
9 Sept 2021
27 Sept 2021
10 Sept 2021
21 Sept 2021
14 Sept 2021
10 Sept 2021 - 13 Sept 2021
Amount
SH-I: Operation & Maintenance of Substation installation
Operation & Maintenance of 11KV/415V Sub-station equipments i/c HT panel, Transformers, Gensets & MV Panels including trouble shooting, preventive maintenance and break down maintenance as required as per good engineering practice, recommendations of the manufacture and instructions of Engineer-In-Charge and as per specification enclosed located at IAA substation by deploying following manpower on all working days i/c Sunday & Holidays.
Senior Supervisor in G Shift i/c Sunday & Holidays (1 no. in each shift & Reliever shall be provided on Weekly Off)
Electrician on round the clock basis i/c Sunday & Holidays (1 no. in each shift & Reliever shall be provided on Weekly Off)
DG Operator on round the clock basis i/c Sunday & Holidays (1 no. in each shift & Reliever shall be provided on Weekly Off)
Khallasi on round the clock basis i/c Sunday & Holidays (1 no. in each shift & Reliever shall be provided on Weekly Off) & (1 nos. in General Shift 6 days a week).
Extra Manpower required for misc. works in case of any emergency for following manpower as & when required:-
Wireman (Skilled)
Khallasi (Unskilled)
SH-II: R & M Works
Dehydration & Filtration of Transformer oil with High Vaccum Filtration Machine to achieve BDV up to the level of relavent IS Dielectric strength as required i/c submission of oil test reports from government approved laboratory after dehydration of oil as and when required.
Testing of Dielectric strength (BDV) of Transformer oil on yearly basis or as & when required for 02 nos. 2 MVA transformers & submission of report from government approved laboratory i/c collection of sample from site, transportation to lab complete as required. (1 Job includes complete testing of oil sample from 01 transformer)
Supply & Toping up the transformer oil in conservator tank upto the recommended level with fresh/treated transformer oil as & when required.
Complete Testing & Calibration of all type of Relays of 12 KV Compact VCB HT Panel i/c submission of report for the same complete as per site requirement.
Servicing & Testing of 12 KV Compact VCB HT Panel i/c servicing of 05 Nos. 630A rating compact VCB Breaker, 2 Nos. PT i/c checking & tightening of connections etc. i/c submission of report from OEM or its Authorised Dealer complete as required on yearly basis. (01 Job- Complete servicing & testing of complete HT panel i/c all the compact VCB breakers, PTs etc.)
Overhauling and Servicing of following rating ABB make ACB of LT Panel.
Rewinding of following openwell pump motors as & when required with enemelled copper winding wire, varnishing i/c greasing replacement of bearings/ bush, repairing of shaft including transporatation charges completed as required. (All dismantle material belongs to the contractor)
3.0 HP, 3 Phase Submersible Pumps
5.0 HP, 3 Phase Submersible Pumps
Supply of following consumables, registers & other material:
Old Cotton Dhoti (nominal size 2m x 1m)
PVC Cotton (ISI make) (1.80cm x 8mm x 0.125 mm)
HT Tape (1 Roll of 3 Nos.)
CRC Bottle (500ml)
Distilled Water
Log Book DG Sets
Log Book Power House
Maintenance Registers
Supply of Silica Gel for Breather
SH- III DSR ITEMS
DSR Items Percentage above/below CPWD Schedule of Rates for E&M (2018) works totaling to Rs.1,00,000/- (Item to be executed as per the site requirement) (All DSR items Rate to be taken excluding GST)
ANAND AND COMPANTY
Suncity Enterprises
NATIONAL SAFETY ENGINEERS
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .