Loading…
Loading…
Tender Value
₹11.9 L
EMD Value
₹23,837
Closing Date
9 Jul 2026, 5:00 pm7d left
RAVI Ladwal
ED - Rewari
Construction of Phase III and IV Non Residential building in Sainik School at Gothra Tappa Khori in District Rewari (VIP Guest House Block) (Pdg. Air Conditioners only).
2026_HRY_533051_1
202618A255A7 86D5 41A0 A9C2 29A1E6CCB08D668BAR
Open Tender
Civil Works
86 days
GOTHARA TAPPA KHORI
2 documents required · 2 mandatory
₹1,000
₹23,837
Yes
2 Jul 2026
2 Jul 2026
10 Jul 2026
2 Jul 2026
9 Jul 2026
2 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | S.I.T.C of UPVC hard Drain Pipe Make: Ploypack, AKG, Dplast. | 300 | Metre | 1 | ₹300 |
| 1.02 | S.I.T.C of flexible pipe 2` white heavy duty. | 300 | Metre | 2 | ₹600 |
| 1.03 | S.IT.C of 4 Core 2.5sqmm copper wire ISI mark Make Plaza / Havells / Polycab / R.R. Kabel / KEI | 350 | Metre | 3 | ₹1,050 |
| 1.04 | COPPER REFRIGERANT PIPING
Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitableadjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm (New HSR 23.35.14.4) | 300 | Metre | 4 | ₹1,200 |
| 1.05 | COPPER REFRIGERANT PIPING
Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitableadjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm (New HSR 23.35.14.1) | 300 | Metre | 5 | ₹1,500 |
| 1.06 | CASSETTE TYPE SPLIT UNITS
25.11.4 Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 230/415V plus 10%, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filtration and ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electro technical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.
Heating and Cooling
1.5 TR with 3 Star BEE Rating (New HSR 25.11.4.7) | 10 | Each | 6 | ₹60 |
| 1.07 | CASSETTE TYPE SPLIT UNITS
25.11.4 Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 230/415V plus 10%, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filtration and ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electro technical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.
Heating and Cooling
2.0 TR with 3 Star BEE Rating (New HSR 25.11.4.8) | 4 | Each | 7 | ₹28 |
| 1.08 | S.I.T.C. of wall mounted stand for outdoor unit | 14 | Each | 8 | ₹112 |
| 1.09 | S.I.T.C. of 5 KVA voltage stabilizer copper wound with 170 upto 270. Suitable for operation on 230V, Hz-10% 50Hz 1 phase AC supply
Make Blue bird/V-guard/Blue guard | 14 | Each | 9 | ₹126 |