Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
24 Sept 2024, 6:00 pmClosed
GE UTILITY ELEC SUPPLY
GE UTILITY ELEC SUPPLY DELHI CANTT-10
REPAIR MAINTENANCE AND REPLACEMENT OF LT PANELS MCCB ACB CHANGE OVER SWITCH EARTHING AT KABUL LINE BAIRD PLACE KOTWALI LINE CEDZ OFFICE CDA ARMY AND ASSOCIATED AREA OF AGE SLDC ES UNDER GE U ELECT SUPPLY DELHI CANTT 10
2024_MES_669749_1
GE ELEC/D-38/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELEC SUPPLY
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE UTILITY ELEC SUPPLY
₹90,000
Yes
8 Nov 2024
2 Sept 2024
25 Sept 2024
2 Sept 2024
24 Sept 2024
16 Sept 2024
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil) for laying of cables or GI pipe and getting out including levelling of bottom suface to required level complete all as specified and directed by Engr-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables and in substation ducts for cushioning of cables etc, complete all as specified and directed by Engr-in-Charge. (Note :Measurement should be after punning down)
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sq cm laid in trenches for cable protection etc complete all as specified and directed by Engr-in-Charge.
Returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engr-in-Charge.
Removing excavated material (ie soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all as specified and directed by Engr-in-Charge.
Supply and lay GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc of 80 mm bore dia complete all as specified and directed by Engr-in-Charge.
All as per item No 7.00 above but of size 50 mm bore dia complete all as specified and directed by Engr-in-Charge.
All as per item No 7.00 above but of size 40 mm bore dia complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement of factory made and tested, Bus bar chamber, outdoor pedestal type, suitable for LT 415 volts 3 phase 4 wire, 50 Hz , AC supply system, having duly insulated four Nos aluminum bus bars (having Multiple holes), of rating 800 Amps , installed on epoxy / SMC type insulator The panel shall be dust and vermin proof, IP-65 Protection class and made of 3.15 mm CRCA MS sheet and 40x40x5mm thick angle iron base frame work, suitable for connection of multiple LT cables of diff size, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement of minimum size 75 cm x 60cm x 45 cm ( box size excluding legs) and mounted on angle iron pedstal 45 cms above groungd level all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc incl necessary PCC work for foundation as directed. Note :- (i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimbles. (ii) Costruction of Foundation & taking out of the old connected cables and reconnection of the same with new thimbles, gland of suitable size are deemed to the above quoted rate. (iii) The feeder piller should have louvers & air vent gasket for natural flow of air. (iv) The bottom of the outer shell contains a detachable plate having provn of entry of armoured cable of adequate size with glands. (v) Danger plate should be fixed on both side of the panel.
S&F in replacement of Air circuit breaker 4 pole 1000 Amps 50 KA with Microprocessor release manual drawout Adjustable type including dismantling & taking out old unserviceable ACB from panels & fabrication works to MS sheet/cutting the BUS bar for proper fitting etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Air circuit breaker 4 pole 800 Amps 50 KA withwith Microprocessor release manual drawout Adjustable type including dismantling & taking out old unserviceable ACB from panels & fabrication works to BUS bar for proper fitting etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of UNSV MCCBs of capacity 630 Amps, TP, 50 KA, 415 Volts 50 Hz, AC, with adjustable thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed by Engr-in-Charge.
Same all as per ser item No 19.00 above, but rating of MCCB 400 Amp, 36 KA complete all as specified and directed by Engr-in-Charge.
Same all as per ser item No 19.00 above, but rating of MCCB 250 Amp, 36 KA complete all as specified and directed by Engr-in-Charge.
Same all as per ser item No 19.00 above, but rating of MCCB 200 Amp, 25 KA complete all as specified and directed by Engr-in-Charge.
Same all as per ser item No 19.00 above, but rating of MCCB 160 Amp, 25 KA complete all as specified and directed by Engr-in-Charge.
Same all as per ser item No 19.00 above, but rating of MCCB 125 Amp, 25 KA complete all as specified and directed by Engr-in-Charge.
Same all as per ser item No 19.00 above but rating of MCCB 100 Amp,25KA complete all as specified and directed by Engr-in-Charge.
S&F in replacement On load change over switch of capacity 400 Amps, four pole, 415 volts, AC, 50 Hz alongwith connected bus bars also complete all as specified and directed by Engr-in-Charge.
S&F in replacement On load change over switch of capacity 630 Amps, four pole, 415 volts, AC, 50 Hz alongwith connected bus bars also complete all as specified and directed by Engr-in-Charge.
M&L for disconnecting burnt end or portion of cable removing the cable from loop including necessary excavation & earth work in soft/loose soil relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals( set of 4 x terminals) including fixing of new lugs for 50 Sqmm 3½ / 4 to 400 Sqmm of LT cable to main switch /panel including taping of XLPE cables complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Voltmeter 0-500 V digital type per existing size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Ammeter 0-400/800 Amp digital type per existing size complete all as specified and directed by Engr-in-Charge.
S&F in replacement of indicator lamp for RYB phases complete all as specified and directed by Engr-in-Charge.
S&F in replacement LT current transformer having ratio 800/5 Amp , 15 VA, Class 0.5 Complete all as specified and directed by Engr-in-Charge
All as per Srl item No.28 herein before but CT ratio 400/5 Amp complete all as specified and directed by Engr-in-Charge.
All as per Srl item No 28 herein before but CT ratio 250/5 Amp complete all as specified and directed by Engr-in-Charge.
S&F in replacement Mild steel sliding door bolts 200 mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed by Engr -in-Charge.
Earthing complete in replacement with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 25 X 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in soft/loose soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991). The quoted rates shall include the following:- (a) Excavation and earth work for drilling hole for electrode in soft/loose Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed. (d) 40 mm nominal bore medium grade GI protection pipe for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
M&L for painting of LT panel boards out door/in door of size above 8.00 Sqmm floor/leg mounted installed at different locations including preparation of exposed surface by removing old paint from the body, cleaning the surface with thinner and applying two coats of synthetic enamelled smoke grey paint complete all as specified and directed by Engr-in-Charge.
All as per srl item No 33.00 here-in-before but of size 5.0-8.0 Sqmm complete all as specified and directed by Engr-in-Charge.
All as per srl item No 33.00 here-in-before but of size below 5.00 Sqmm complete all as specified and directed by Engr-in-Charge.
M&L for cutting and removing grass, vegetation bushes etc from surrounding of installation/LT Panel /Four Pole structure/Sub Stations and removing all rubbish to a distance not exceeding 50m complete all as specified and directed by Engr-in-Charge.
S&F in replacement CRCA MS sheet of thickness 3.15 mm powder coated finish over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer with apran for cable entry closing locking arrangement including all fixing acessories i.e. suitable size of hinge, nuts, bolts, washers, cutting and welding works etc in the existing panels as per site condition complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing, testing and commissioning in replacement of LT underground cables of following sizes, 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-7098, Part-II marked, laid in trenches/ duct/ under road/ footpath/ etc or against re-routing / diversion from residential buildings/ road/ footpath etc complete all as specified and directed by Engr In Charge.
25 Sqmm 3.5 core
35 Sqmm 3.5 core
50 Sq mm 3.5 core
70 Sq mm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as directed for the size 16 to 25 Sqmm x 3.5 /4core complete all as specified and directed by Engr-in-Charge.
All as per item No 39.0 but of size 35 to 50 Sqmm x 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item No 39.0 but of size 70 to 95 Sqmm x 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item No 39.0 but of size 120 to 150 Sqmm x 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item No 39.0 but of size 185 to 240 Sqmm x 3.5 core complete all as specified and directed by Engr-in-Charge.
S&F in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections cable of size 16 Sqmm 2 core complete all as specified and directed by Engr-in-Charge.
All as per Sr item No 44.0 above but of size 10 Sqmm complete all as specified and directed by Engr-in-Charge.
All as per Sr item No 44.0 above but of size 6 Sqmm complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate in mass concrete and filling for foundation of Panel or similar works complete all as specified and directed by Engr-in-Charge.
Demolition of path/concrete in ground floors or pavings nexc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge.
M&L for Cement Concrete type C-1 mix, 1:3:6 (20mm graded aggregate) finishing the top surfaces fair and even complete all as specified and directed by Engr-in-Charge.
Dismantling the existing unserviceable (damaged/broken) PCC electric pole of any type and size, from ground after necessary excavation & breaking of concrete foundation & encasing the pole including making good the disturbed surfaces complete all as specified and directed by Engr-in-Charge.
M&L for preparation of painted surface of LT Panel of any size for fixing of FLOURCENT REFELCTIVE LETTERING as follows of approved colours complete all as specified and directed by Engr-in-Charge. (a) Re-write the details (as given by the Engr In Charge) of Incoming & outgoing circuits (not more than-8 Nos), on the LT panels in capital letters of size not less than 30 mm width and 40 mm height and works not exceeding 80 letters per panel. (b) "LT PANEL" should be re-write on both front and back side of the LT Panel size not less than 50 mm width and 60 mm height.
S&F in the existing LT panel, OFF load change over switch in replacement of capacity 400 Amps, four pole, 415 volts, AC, 50 Hz alongwith connected of existing cables complete all as specified and directed by Engr-in-Charge.
S&F in the existing LT panel, OFF load change over switch in replacement of capacity 200 Amps, four pole, 415 volts, AC, 50 Hz alongwith connected of existing cables complete all as specified and directed by Engr-in-Charge.
M&L for spreading of stone aggregate of size 40 mm in surounding area of outdoor LT Panel manually without damaging any equipments, cable or parts , spreading & levelling of finished gravel uniformaly in layers n. ecc. 15 cm thick watered and rammed to true surfacecomplete all as specified and directed by Engr-in-Charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
ALLIED CONSTRUCTION (BID ID -3111336)
Rajindera Enterprises (BID ID -3109862)
mayur enterprises (BID ID -3098846)
Ridhi engineers and builders (BID ID -3111780)
DS CONSTRUCTION (BID ID -3106990)
MV Engineers And Contractors (BID ID -3098081)
Vijay Electricals (BID ID -3107962)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .