Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.7 CrAccepted-Finance 1103 RACHIT SUNSHINE UTWANDI ROAD TIDKE NAGAR NASHIK | ₹15.7 Cr | 1 | Accepted-Finance L-1 |
| 2 | 2₹16.6 CrRejected-Finance | ₹16.6 Cr | 2 | Rejected-Finance h |
| 3 | 3₹18.2 CrRejected-Finance HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | ₹18.2 Cr | 3 | Rejected-Finance h |
| 4 | Rejected-Technical | - | - | Rejected-Technical all techincal document are Not clae |
| 5 | Rejected-Technical | - | - | Rejected-Technical all techincal document are Not clae |
Tender Value
₹17.7 Cr
EMD Value
₹8.8 L
Closing Date
18 Oct 2023, 6:00 pmClosed
Executive Engineer Public Works Division Sangamner
Office of the Executive Engineer Public Works Division Sangamner
Construction of 30 Beded Rural Hospital and Residential Quarters at Sanvantsar, Tal.Kopargaon Dist.Ahmednagar
2023_PWR_950255_1
PWD SGM/ Notice No.23 for 2023-2024-1
Open Tender
Civil Works - Buildings
720 days
TAL.KOPARGAON
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,540
₹8.8 L
13 Mar 2024
4 Oct 2023
20 Oct 2023
4 Oct 2023
18 Oct 2023
4 Oct 2023
Amount
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 meter) By Mechanical means
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 metre to 3.0 metre) By Mechanical means
Conveying materials obtained from road cutting including all lifts, laying in layers of 20 centimeter to 30 centimeter breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50 meter to 300 meter inclusive from the site of excavation to the site of deposition as directed.
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15 centimetre to 20 centimetre. including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 0.5 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 0.5 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 Cement Mortor diametre about 30 -60 centimetre deep at 15 centimetre centre to centre as close to the wall as possible and to inject 0.5 percent of aldrin or clorophyrifos at the rate of 7.5 litres per hole and sealing the same with proper filling and covering 10 years guarantee on bond paper.
Providing soling using 80 milimetre size trap metal in 15 centimetre layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand Vertical Shaft Impactor Grade finely washed etc)
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand Vertical Shaft Impactor Grade finely washed etc)
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand Vertical Shaft Impactor Grade finely washed etc) (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand Vertical Shaft Impactor Grade finely washed etc) (A) GROUND FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand Vertical Shaft Impactor Grade finely washed etc) (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand Vertical Shaft Impactor Grade finely washed etc) (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand Vertical Shaft Impactor Grade finely washed etc) (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Ceement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand Vertical Shaft Impactor Grade finely washed etc) (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite / quartzite / gneiss metal for Reinforced Cement Concrete canopy as per detailed designs and drawings including steel centering, formwork, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing etc. complete (excluding reinforcement), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand Vertical Shaft Impactor Grade finely washed etc) (A) GROUND FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Ceement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand Vertical Shaft Impactor Grade finely washed etc) (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with Cement Mortor 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand Vertical Shaft Impactor Grade finely washed etc) (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing in position Thermo Mechanical Treatment Ferrous material - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. (B) FIRST FLOOR
Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in Cement Mortor 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.
Providing fly ash brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing Second class fly ash brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 millimetre diameter / two hoop iron strips 25 millimetre x 1.60 millimetre at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in Cement Mortor 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with Cement Mortor 1:3 admixed with approved water proofing compound and finally top finishing with average 20 millimetre thick layers of same mortar added with jute fiber at 1 Kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetre X 300 millimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rupees 500/- including ponding test etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing water proof bedding for flooring of Bath and Water Closet 25 millimeter thick in Cement Mortor 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. (A) GROUND FLOOR
(D) THIRD FLOOR
Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per American Society of Testing and Materials) C 1549 and ASTM C 1371 respectively, Volatile Organic Compounds less than 10 cc/gram. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing internal cement plaster 12 millimeter thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing internal cement plaster 20 milimetre thick in two coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material of Ambuja / Mor Chap or equivalent make ) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1 kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing fine cement finish 1.5 millimetre thick over green plaster surface including scaffolding curing etc. complete. (A) GROUND FLOOR
Providing patti/ band 75 milimetre wide on plastered surface 12 milimetre to 15 milimetre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing patti/ band 100 milimetre wide on plastered surface 12 milimetre to 15 milimetre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing patti/ band 150 millimetre wide on plastered surface 12 millimetre to 15 millimetre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Rrinforced Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / Burnt Brick masonry and or tying by binding wire etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595 milimetre x 595 milimetre having 15 milimetre thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600 x 600 milimetre made from hot dipped Galvanised Iron steel sections ion silhouette profile, rotary stitched double webbed white with 6 milimetre reveal profile (white/black), wherein, main T runner of size 42 milimetre x 14 milimetre between main tee 600 milimetre center-tocenter and secondary cross T of size 33 x 14 x 0.43 milimetre thick of length 600 milimetre long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200 milimetre x 600 milimetre resting on periphery wall Profile wall section 19 milimetre (7+7) x 19 milimetre x0.40 thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using Galvanised Iron soffit cleats of size 25x35x1.6 milimetre of required length fixed to the ceiling with 6 milimetre diametre and 50 milimetre long dash fastener, 4 milimetre diametre Galvanised Iron adjustable rods with powder-coated/good quality Galvanised Iron level adjustment clips of 35 x 35 x 0.8 milimetre spaced @1200, center-to-center along main T all complete at all heights as per the specifications, drawings and as per the directions of Engineer-in-charge. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and Reinforced Cement Concrete beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to Indian Standard 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying vitrified mirror / glossy finish tiles having size 590 millimeter to 605 millimeter x 590 millimeter to 605 millimeter of 8 to 10 millimeter thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.b) Skirting (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 milimetre thickness of having a strength of 300 kilogram/Square centimetre of approved quality and shape on a bed of crushed sand of 25 to 30 milimetre thick including skirting joints and cleaning etc. complete (A) GROUND FLOOR
Providing and laying ceramic tiles having size 30 centimeter. x 45 centimeter confirming to corresponding Indian Standard for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimeter x 30 centimeter and confirming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortor 1:3 curing and cleaning etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. (A) GROUND FLOOR
Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/ dado/ window boxing etc. on Cement Mortor 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying machine cut machine Polished Kota stone flooring 25 milimetre to 30 milimetre thick and required width in plain/ diamond pattern on bed of 1:6 Cement Mortor including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces, (excluding the primer coat.) etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and applying 2 coats of 100% Pure acrylic low Volatile Organic Compound sand Alkylphenol Ethoxylates & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1mm. Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low Volatile Organic Compounds & Odour putty. This surface should be primed with water based low Volatile Organic Compounds Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 centimetre. Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5mm The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etc complete, as directed by Engineer in charge. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetre X 40 millimetre X 5 millimetre with oil painting, etc. complete (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing Country teak wood Four leaf paneled shutters, 35 millimeter thick style and rail and 25 millimeter thick panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete. (A) GROUND FLOOR
Fire Door 45 milimetre 1HR FRL (60/60) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to Indian Standard: 3614 Part 2. Providing of make 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the Indian Standard: 3614 Part 2 and British Standard: 476 part 22 at National Test House, Governmentt of India laborator and/or with Central Building Research Institute, Goverment of India undertaking with standard heating conditions as specified in Indian Standard:3614 Part II 1992 and British Standard: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer. a) Door Frame: Supplying brand frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 kilogram/cubic metre) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per Indian Standard:401and kiln seasoned to moisture below 15% as per Indian Standard:1141 of section 120 X 60 milimetre spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10 milimetre x 4 milimetre affixed in the slit of the Frame for fire and smoke sealing, etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
Fire Door 45 milimetre 1HR FRL (60/60) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to Indian Standard: 3614 Part 2. Providing of Tufwud make 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the Indian Standard: 3614 Part 2 and BS: 476 part 22 at National Test House, Goverment of India laborator and/or with Central Building Research Institute, Goverment of India undertaking with standard heating conditions as specified in Indian Standard:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer. b)Shutter : Providing of 65 milimetre thick asbestos free composite - 3 criteria - fire, heat and smoke check Accoustic Door Shutter with flame guard of 120 minutes Indian Standard: 3614 part -II comprising of 2 x 9 milimetre Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per Indian Standard:401and kiln seasoned to moisture below 15% as per Indian Standard:1141 frame work of 100x32 milimetre with 32milimetre thick infill of ceramic fiber (density 128Kgs/CMT), vermaculite mix faced with 6 milimete Fire retardant High Density ply, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of In tumescent paint of minimum 200 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10 milimete x 4 milimetre concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. (A) GROUND FLOOR
(B) FIRST FLOOR
Providing and fixing 34 millimetre thick moulded door shutter consisting of solid core single leaf flush door of 30 millimetre thickness lipped with 15 millimetre ( 5millimetre x 3) thick x 30 millimetre width on one style and top rail and 10 millimetre (5millimetre x 2) thick x 30 millimetre width on other style and bottom rails. The inner panels laminated with 2 millimetre thick termite proof, water proof and fire resistant moulded Poly Vinyl Chloride sheet with 2, 4, 6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 millimetre plain and /or pre lam Poly Vinyl Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Poly Vinyl Chloride lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 metre x 2.40 metre with aluminium door frame of powder coated section 101.60 x 44.75 millimetre, 3.18 millimetre thick and shutter comprising of powder coated section having bottom and lock rail of size 150 millimetre x 44.5 millimetre x 3.00 millimetre thick top rails 47.62 x 44.45 millimetre x 3.00 millimetre thick, vertical style 47.62 x 44.45 millimetre, 3.00 millimetre thick and for shutter plain glass panes 5 millimetre thick for top panels and 12 millimetre thick both side laminated phenol bonded particle board panels for bottom panels etc., Indian Standard Institute, mark , heavy duty, Hydraulic floor spring of 150 kilogram capacity, having heavy duty concealed lock, necessary beading, glazing clips, Poly Vinyl Chloride gaskets, 250 millimetre length tower bolts, 150 millimetre diagram pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc. Complete (B) FIRST FLOOR
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and Fixing 30 millimetre thick " FACTORY MADE BOTH SIDE PRELAMINATED SOLID PANEL Poly Vinyl Chloride DOOR SHUTTER consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 millimetre for styles and 15 X l5 millimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Vinyl Chloride 'C ' channel made from 5 millimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubicmetre, of size 30 millimetre thickness 70 millimetre width out of which 50 millimetre shall be flat and 20 millimetre shall be tapered in 45 angle on either side forming stiles; and 5 millimetre thick, 95 millimetre wide Poly Vinyl Chloride sheet out of which 75 millimetre shall be fait and 20 millimetre shall be tapered in 45 on the inner side to form top and bottom rail and 115 millimetre wide Poly Vinyl Chloride sheet out of which 75 millimetre shall be fait and 20 millimetre shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5 millimetre (+/- 0.25) thick Poly Vinyl Chloride strip of 20 millimetre width is to be stuck on the bottom side of the 'c' channel prelaminated paneling of 5 millimetre (+/- 0.25) thick Poly Vinyl Chloride sheet to be fitted inside the Mild Steel frame welded / sealed to the styles and rails with 5 millimetre (+/- 0.25) x 30 mm Poly Vinyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc, 10 millimetre thickness (5 millimetre (+/-0.25) x 2 Numbers ) 20 millimetre wide cross Poly Vinyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 Numbers Mild Steel powder coated but hinges of size 100 millimetre x 25 millimetre x 2 millimetre using 32 millimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 millimetre size steel screws including fixture fasting. Complete as per direction of engineer -in -charge . (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing in position. (as per Indian Standard1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 milimetre at weight 0.547 kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 milimetre at weight 0.695 kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 milimetre at weight 0.659 kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram/Running metre. Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram/Running metre. And handle section 40 x 18 x 1.25 milimetre at weight 0.417 kilogram/Running metre. and top section 40 x 18 x 1.25 milimetre at weight 0.417 kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts etc, complete. With powder coating with box (B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 X 38.10 X 0.90 millimetre at weight 0.637 kilogram per Running metre. with window frame bottom track section 92 X 31.75 X 1.30 millimetre at weight 1.070 kilogram per Running metre. Top and side track section 92 X 31.75 X 1.30 millimetre at weight 0.933 kilogram per Running metre. The shutter should be of bearing bottom 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. Inter locking section 40 X 18 X 1.10 millimetre at weight 0.469 kilogram per Running metre. and handle and top section 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to Indian Standard. 6524-1983 having 6 millimetre diametres bars 3 Numbers And stirrups @ 250 millimetre centre to centre and fixing in wall with 6 Numbers of hold fast of 12 millimetre diametre bars 500 millimetre long including primer and oil painting etc, complete) frame size 60 millimetre x 100 millimetre. (B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kilogram per squaremetre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 millimetre diametre and vertical pipe of 38 millimetre dia at 0.60 metre centre to centre or as required and horizontal pipes of 25 millimetre diametre in three rows, all pipes of 2 millimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimetre diametre above newel post of 75 millimetre diameter etc. complete (Prior approval of sample and brand by Executive Engineer is necessary before use) (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing Chromium Plated 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing 25millimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber]. (A) GROUND FLOOR
Providing and fixing 15 milimetre diametre screw down bib/ stop tap of brass including necessary socket union nut complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing 20 milimetre diametre screw down bib/ stop tap of brass including necessary socket union nut complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing screw down 15 milimetre diametre wheeled stop tap of brass including necessary sockets/union nut complete (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing push cock (Self closing tap) symet type of 15 mm dia. including necessary socket, testing etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 63 x 45 centimetre size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, Chromium Plated Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. (A) GROUND FLOOR
(B) FIRST FLOOR
Providing and fixing 15 centimeter x 10 centimeter salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying concrete pipes of Indian standard Non Pressure class of 150 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. (A) GROUND FLOOR
Providing and laying concrete pipes of Indian standard Non Pressure class of 300 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. (A) GROUND FLOOR
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and airtight Cast Iron cover of 75 kilogram with lid and frame fixed in cement concrete.
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Warepipes, Brick Masonry, plastering from inside and Cast Iron lid cover of 75 kilogram with lid and frame fixed in cement concrete. (A) GROUND FLOOR
Providing and fixing 450 millimetre X 550 millimetre size superior type Belgium mirror with 16 milimetre diametre nickel plated towel rod etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing chromium plated towel rod 16 millimetre diametre and 75 centimetre in length including all accessories complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing Chromium Plated Angular stop clock with wall flange of approved make including necessary sockets/union nut etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing Chromium Plated BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing 40 millimetre diametre Ball cock medium type with Poly Vinyl Chloride float including sockets and necessary fittings and tested as per municipal requirements etc. complete. (B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing 15 millimetre diametre Ball cock medium type with Poly Vinyl Chloride float including sockets and necessary fittings and tested as per municipal requirements etc. complete. (B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing wall mixer with overhead shower,shower arm,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing Chromium Plated wall mixer with provision for overhead shower with 115 milimetre long bend pipe and wall flange of approved make including necessary sockets/union nut etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing Orissa Pan of size 580 x 445 x 260 milimetre with approved make flush valve including trap, Cast Iron soil and vent pipe upto outside face of wall including 100 milimetre diametre Cast Iron plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing white Opal series European type wall-hung, of size 400 milimetre x 370 milimetre x 575 milimetre with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 milimetre diametre Cast Iron plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with Poly Vinyl Chloride 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 milimetre diameter Poly Vinyl Chloride flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. (A) GROUND FLOOR
Providing and fixing 75 milimetre diametre stabiliser pipe/ Poly Vinyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing 100 milimetre diametre stabiliser pipe/ Poly Vinyl Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing High Density Polyethylene container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres (B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing on walls/ ceiling/ floor 15 milimetre diametre Chlorinated Poly Vinyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing on walls/ ceiling/ floor 20 milimetre diametre Chlorinated Poly Vinyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing on walls/ ceiling/ floor 25 milimetre diametre Chlorinated Poly Vinyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing on walls/ ceiling/ floor 32 milimetre diametre Chlorinated Poly Vinyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing on walls/ ceiling/ floor 40 milimetre diametre Chlorinated Poly Vinyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing on walls/ ceiling/ floor 50 milimetre diametre Chlorinated Poly Vinyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing 15 centimetre rigid Poly Vinyl Chloride Nahani trap including Poly Vinyl Chloride grating ,bend,connectingpiece of Unplasticised Poly vinyl Chloride pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Executive Engineer is necessary before use) (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing Poly vinyl Chloride Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly vinyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40 milimetre from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly vinyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 years guarantee bond for payment) (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying in trenches 15 milimetre diametre Chlorinated Poly Vinyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying in trenches 20 milimetre diametre Chlorinated Poly Vinyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying in trenches 25 milimetre diametre Chlorinated Poly Vinyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying in trenches 32 milimetre diametre Chlorinated Poly Vinyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying in trenches 40 milimetre diametre Chlorinated Poly Vinyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying in trenches 50 milimetre diametre Chlorinated Poly Vinyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete. (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing in position Unplasticised Poly vinyl Chloride ultra violet stabilized 110 milimetre outer diameter cowl dome confirming to Indian Standard-4985 including making joints with solvent cement etc. complete (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing Glass self 125 milimetre wide and 600 milimetre long with necessary chromium plated brackets providing Tear Wood gutties etc. complete (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
(B) FIRST FLOOR
Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. Reinforced Cement Concrete pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, Glass Fiber Reinforced Concrete admixtures, Colour pigments, Fiber up to thick of 230 milimetre/ 25 milimetre including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) (A) GROUND FLOOR
(B) FIRST FLOOR
Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre Base Metal Thickness ( BMT ) (0.5 milimetre TCT ), Hi-strength steel with min.550 Mega Pascal yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Square Metre) (A) GROUND FLOOR
(B) FIRST FLOOR
Supply, fixing and installation of 4 milimetre thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 milimetre thick, total thickness of aluminium composite panels not to be less than 4 milimetre, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 milimetre X25 milimetre X 3 milimetre thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 milimetre X 1200 milimetre and fixed to the building structure as per design through 50 milimetre X 50 milimetre X 5 milimetre Mild Steel angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of Superintending Engineer is necessary before inclusion of this item in estimate) (A) GROUND FLOOR
(B) FIRST FLOOR
Providing and fixing 90 centimetre X 60 centimetre Granite plate engraving 10 centimetre. height letter, figures including painting the lefters / figures with approved colour and shade complete. (A) GROUND FLOOR
Providing and fixing in position alluminium strips of size 50 milimetre x 3 milimetre for nosing the steps including fixing with screws and raval plugs, bending and cutting to the required shape and size, finishing with paint, necessary mortar bedding of 1:3 cement mortar to get exact line and level including watering and curing etc.complete (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing lightening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25 millimeter diametre 1.2 millimeter thick with multiple points head 1.2 metre long ( Heavy Duty) welded or clamped to Galvanised Iron pipe pole B grade 50 millimeter diametre of requiired length with Mild Steel round bnase plate 25 centimetre diametre and 10 millimeter thick at bottom embeded in cement concrete 1:3:6 foundation of size 45 centimetre diametre x 45 centimetre Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 centimetre with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 kilogram charcoal and salt with altemate layers of charcoal and salt and Galvanised Iron pipe 40 millimeter diametre 2 meter length burried in earth upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item. (A) GROUND FLOOR
Supply, fixing and installation of 4 milimetre thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 milimetre thick, total thickness of aluminium composite panels not to be less than 4 milimetre, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 milimetre X25 milimetre X 3 milimetre thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 milimetre X 1200 milimetre and fixed to the building structure as per design through 50 milimetre X 50 milimetre X 5 milimetre Mild Steel angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of Superintending Engineer is necessary before inclusion of this item in estimate) (A) GROUND FLOOR
Providing soak pit of size 120 centimetre X 120 centimetre X 120 centimetre including excavating and filling with brick-bats. (A) GROUND FLOOR
RWH - Shallow Percolation Pit providing, constructing 2.0 metre deep shallow depth percolation pit comprising of 1.0 metre diametre pre-cast Reinforced Cement Concrete rings, 300 milimetre thick side filling around outside of Reinforced Cement Concrete rings (annular space) with 40 milimetre size boulders including filling of percolation pit up to 0.5 metre depth (from bottom up) with 25-75 milimetre clean washed gravels followed by 0.5 metre depth of 10-25 milimetre of clean washed stones followed by 0.5 metre of washed river fine aggregate (natural sand/crushed sand Vertical Shaft Impactor grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand Vertical Shaft Impactor grade finely washed etc.) media layer including covering with Reinforced Cement Concrete slab, manhole frame & cover, Poly Vinyl Chloride rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge (A) GROUND FLOOR
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per American Society of Testing and Materials):-0.30% Flammability as per American Society of Testing and Materials Tensile strength:-115 Mega Pascal Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid Poly Vinyl Chloride: -100 milimetre Outlet pipe size rigid Poly Vinyl Chloride:-80 milimetreGas outlet rigid Poly Vinyl Chloridewith Valve: 20 milimetre Bacteria immobilization Poly Vinyl Chloride mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below c) Up to 25 user size (1.5 metre x 1.0 metre x 1.0 metre), Capacity of biodgester:-1500 liters, Area of top, bottom and side walls:- 8 square metre, Area of partition walls: 2 square metre, Total weight of frp: - 82.80 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5 milimetre, One Number of inside partitions: - 3, Minimum thickness of partition wall: 3milimetre (A) GROUND FLOOR
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per American Society of Testing and Materials):-0.30% Flammability as per American Society of Testing and Materials Tensile strength:-115 Mega Pascal Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid Poly Vinyl Chloride -100 milimetre Outlet pipe size rigid Poly Vinyl Chloride:-80 milimetre Gas outlet rigid Poly Vinyl Chloride with Valve: 20 milimetre Bacteria immobilization Poly Vinyl Chloride mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below d) Up to 40 user size (2.0 metre x 1.0 metre x 1.0 metre), Capacity of biodgester:-2000 liters, Area of top, bottom and side walls: - 10 square metre, Area of partition walls: 3 square metre, Total weight of frp: - 106.20 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5 milimetre, One Number of inside partitions: - 3, Minimum thickness of partition wall: 3 milimetre (A) GROUND FLOOR
Providing and laying in situ cement concrete M30 with tremix treatment for 200 milimetre thickness for flooring with groove cutting of 4 milimetre wide and 20 milimetre deep with necessary refilling with bitumen etc. complete.
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimetre x 450 millimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimetre thick supports with kadappah top 35 to 40 millimetre thick and polished granite 16 to 20 millimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete.
.(C) SECOND FLOOR
Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 milimetre stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 Kilogramload bearing capacity of trolley made out of 20 milimetre Poly Urethane Conformal coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 milimetre Stainless Steel decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge) (B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 milimetre thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 milimetre thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete (A) GROUND FLOOR
(B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing stainless steel sink of size 600 x 510 x 200 milimetre incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. (B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and fixing Chromium Plated sink cock with raised J" shaped swinging casted spout of approved make including necessary sockets/ union nut etc. complete." (B) FIRST FLOOR
.(C) SECOND FLOOR
Providing and laying in trenches 32 milimetre diametre heavy grade having embossed as Indian Standard Institute Mark galvanised iron pipes of 3.89 ilokramg/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in Public Work Department chowky or as directed etc. complete.
Providing and laying in situ cement concrete M -30 with tremix treatment for 200 millimetre thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 millimetre wide and 20 millimetre deep with necessary refilling with bitumen ( excluding reinforcement) with Natural sand etc. complete.with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.
Providing and fixing 50 milimetre diametre medium class Galvanised Iron pipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in cement concrete block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etc. complete.
Providing and erecting 1.5 metre high wire fencing with seven rows of barbed wire supported on Mild Steel Angles ( 50 millimetre x 50 millimetre x 6 millimetre) at 2.5 Metres, Center to center including excavating pits for foundqtion, fixing post in cement cocnrete 1:4:8 of size 45 x 45 x 45 centimetre fastening the wire and painting the Mild Steel Angles with one coat of red lead primer and two coats of painting etc.complete.
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material
Supplying hard murum/ kankar at the road site, including conveying and stacking complete.
Spreading hard murum/ soft murrum/ gravel or kankar for side width complete
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete.
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ Vertical Shaft Impactor grade finely washed crushed sand) conforming to Indian Standard: 383, the size of coarse aggregate not exceeding 25 millimetre, , cement content not to be less than 150 Kilogram per Cubic metre, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Megapascale at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.
Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ Vertical Shaft Impactor grade finely washed crushed sand) conforming to Indian Standard 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @ 0.6 metre X 0.6 metre centre to centre, admeasuring 80 milimetre at bottom and 40 milimetre at top with depth of 75 milimetre and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.
Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (appraox. 25% larger than the initial 3 milimetre.to 4 milimetre. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer. (A) Contraction and longitudinal joints (15 milimetre. deep x 8 milimetre.wide)
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to Indian Standard 3395 : 1997 below concrete pavement including all materials and labour complete.
Providing and fixing in position Thermo Mechanical Treatment Ferrous material 500, 25 milimetre diametre dowel bars precoated with anticorrosive epoxy paint of required Diametre 60 centimetre Long and at 30.00 centimetre. Centre to Centre and wherever directed including handling, straightening, necessary cutting supported by Thermo Mechanical Treatment Ferrous material 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating half length with bituminous paint as directed etc. complete.
Providing and fixing in position TThermo Mechanical Treatment Ferrous material 500, tie bars precoated with anticorrosive epoxy paint of 12 millimetre diametre 70 centimetres long and at 30.00 centimetres Centre to Centre and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening , supported by assembly of Thermo Mechanical Treatment Ferrous material 500, chairs with proper alignment etc. complete.
Cutting transverse contraction joints 3 to 4 milimetre wide and depth 60 milimetre. in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 milimetre. wide at top having depth of 15 milimetre. as directed by Engineer incharge.
Conveying materials obtained from road cutting including all lifts, laying in layers of 20 centimeter to 30 centimeter breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50 meter to 300 meter inclusive from the site of excavation to the site of deposition as directed.
Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 milimetre thickness of having a strength of 300 kilogram/Square centimetre of approved quality and shape on a bed of crushed sand of 25 to 30 milimetre thick including skirting joints and cleaning etc. complete
Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 milimetre depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete )
Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 milimetre between rough shahabad and Reinforced Cement Concrete walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 milimetre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.
Providing and laying vitrified matt fininsh tiles having size 590 milimetre to 605 milimetre x to 605 milimetre of 8 to 10 milimetre thickness and confirming Indian Standard. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring
Providing and laying vitrified stone effect finish tiles having size 590 to 605 milimetre x 590 to 605 milimetre of 8 to 10 milimetre thickness and confirming to Indian Standard. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including required position laid on a bed of 1:4 cement mortarincluding neat cement float, filling joints, curign and cleaning etc. complete. b) Skirting
Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to old plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 millimetre with lock plate of 3.15 millimetre thickness reinforced with 35 x 35 x 5 millimetre angle section fitted with sliding bolts and handles for both sides, deep Mild Steel channel section of depth and thickness not less than 65 millimetre and 3.15 millimetre respectively with hold fast arrangements, Mild Steel Bracket plate 300 x 300 x 3.15 millimetre minimum size and shape with square bar, suspension shaft of minimum 32 millimetre diameter, hood cover of Mild Steel sheet not less than 0.9 millimetre thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (Indian Standard 62481979) (With mechanical gear)
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 X 38.10 X 0.90 millimetre at weight 0.637 kilogram per Running metre. with window frame bottom track section 92 X 31.75 X 1.30 millimetre at weight 1.070 kilogram per Running metre. Top and side track section 92 X 31.75 X 1.30 millimetre at weight 0.933 kilogram per Running metre. The shutter should be of bearing bottom 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. Inter locking section 40 X 18 X 1.10 millimetre at weight 0.469 kilogram per Running metre. and handle and top section 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box
Boring work (including transport.) 200/215 milimetre diameter in the soil / gravel surface Bore diameter of 150 milimetre in solid rock. This includes diameter drilling work. (Wet drilling) MJP Bore Well SSR Shedule 'B' A (item no 1)
After completion of drilling bore well, capacity test by flushing (air lift method) is measured with 90 degree "V" notch. MJP Bore Well State Schedule Rate Shedule 'B' A (item no 2)
180 milimetre diameter Poly Vinyl Chloride Casing pipe (8 kilogram / centimetre2) (Indian Standard 4985-1988) In exceptional circumstances / Casing pipes with a rock surface and if more than 40 feet of casing pipe is required, the casing should be used with the technical approval of the Deputy Engineer and Geologist.
180 milimetre diameter Poly Vinyl Chloride Casing pipe (8 kilogram / centimetre2) (Indian Standard 4985-1988) Casing lowering, grounding
180 milimetre diameter cap for Poly Vinyl Chloride pipe.
Preparing Lawn (30 centimetre depth) : Excavated the ground to a required depth of 30 centimetre .removing and conveying unwanted stuff to arequired distence as directed. Filling fresh garden soil /silt and manure in excavated area in 3:1 proportion to a height. of 30 centimetre .Mixing garden soil and manure thrughly well leveling watering the same.. planting ready plants of edging /border at distance of 25 centimetre apart by watering,sterring of casualitys ,etc complete.
Preparing Edging or border : Excavating the ground to a required depth of 20 centimetre in the required area removing and conveying unwanted stuff, rubbish to the required distance as directed. Filling the excavated part with fresh soil and maure in 3:1 proportion to a required height to 20centimetre. Mixing, levelling, watering the same.Planting rooted edging/border plants at distance of 20 centimetre apart watering,weeding,stirring of soil, replacing casualties, pruing if necesaary etc.complete.
Preparing clipped Hedge:- Excavating the ground to a required depth of 30 centimetre. Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil & manure in excavated area in 3:1 proportion to a height of 30 centimetre. Mixing garden soil & manure thoroughly, well leveling, watering on previous night. Planting Hedge plants of required species in two rows. Distance between two rows & between two plants will be 25 centimetre. Maintaining till well established by watering, weeding, strring the soil and clipping if necessary etc. complete. (R.A. No.5)
Preparing Flower Bed:- Excavating the ground to a required depth of 30 centimetre. Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil & manure in excavated area in 3:1 proportion to a required height of 30 centimetre. Mixing garden soil & manure thoroughly, well leveling, watering on previous night. Planting seedling of required annuals 25 centimetre. apart Maintaining till well established by watering, weeding, strring replacing of casualties etc. complete. (R.A. No.6)
Preparing Canna Bed:- Excavating the ground to a required depth of 30 centimetre. Removing rubbish & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil & manure in excavated area in 2:1 proportion to a required height of 30 centimetres. Mixing garden soil & manure thoroughly, well leveling, watering on previous night. Planting well leveling, watering on previous night. Planting well developed Canna rhizomes 40 centimetre apart. Maintaining till well established by watering, weeding, Strring replacing, casualatie etc. complete. (R.A. No.7)
Preparing Shrubbery : Excavating the ground to required depth of 30 centimetre, removing and conveying unwanted stuff to a required distance as directd. Filling fresh garden soil & Manure in excavated area in 3:1 proportion to a height of 30 cms. Mixing garden soil and manure thoroughly well levelling, watering on previous night. pl,anting well developed shrubs plant 0.5 Metres apart as directed and maintaining till well established by watering,weeding,stirring, replacing casualties etc. complete.
Planting small and medium size ornamental/Flowering plant:- Diggin pit with size 0.6 metre x 0.6 metre x 0.6 metre, removing and conveying unwanted stuff to a required distance as directed. Filling the pit with fresh garden soil & Farm Yard maure upto a height of 0.60 metre in 3:1 proportion. Mixing sol and manure thoroughly well, levelling, watering the same previous night. Planting suitable ground covers as directed in staggering pattern, distance between two rows 25 centimetre. watering and maintaining till well established.
Planting large flowering/Shady trees 9 height 2 metre:Digging pit with size 0.9 metre x 0.9 metre x 0.9 metre removing and conveygin unwated stuff to a required distance as directed. Filling the pit with approved excavated amterial upto a height of 0.3 metre and remaining height of 0.6 metre with fresh soil and maure in 3:1 proportion. Mixing soil and manure toroughly well leveling as directed, watering previous night,panting one or two year old minimum 2 meter height, healthy sapling as per specifications.Maintaining tell well established by watering, weeding, stirring of soil replacing of casualties etc. complete.
Rose plant :- Excavating pit with size 0.3 x 0.3 x 0.3 metre removing and conveying unwanted stuff to a required distance as directed. Filling fresh garden soil and manure in excavated area in 3:1 proportion to a required height to 0.3 metre. Mixing garden soil & manure thoroughly well,,levelling, watering on previous night.Planting 10 to 50 centimetre height healthy plant of required rose varietyh.Maintaing till well established by watering,weeding, stirring,replacing of casualties etc complete.
Mogra plant / Creepers/Climbers :- Excavating pit with size 0.3 x 0.3 x 0.3 metre removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a height of 0.15 metre and remaining height of 0.15 metre with fresh garden soil and manure in 3:1 proportion.Mixing garden soil & manure thoroughly well,,levelling, watering on previous night.Planting one or two year old healthy plant as per specifications.Maintaing till well established by watering,weeding, stirring,replacing of casualties etc complete.
Preparing ground covers: Excavating the ground to a required depth of 20 centimetre. removing & conveying umwanted stuff, rubbish to the required distance as directed. Filling the Excavated area with fresh garden soil & F.Y. Manure in 3;1 proportion to a height of 20 centimetre. Mixing, levelling watering the same previous night. Planting suitable ground covers as directed in staggering pattern, distance between two rows 25 centimetre., watering and maintaining till well established.
Farm Yard Manure: Supplying on site well decayed, well dried, well powdered, without clods and free from stones, dried grass and other rubbish material. The colur of the manure generally be black. The manure will be measured by measuring box. (Farma) (Item includes Transporting, loading unloading etc.) lead charges for 20 kilometre is considered.
Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along road side making the ground clean by showel and phavaras etc. complete. Specification No. As directed by Engineer in charge. State Schedule Rate I.No. 21.33, Sr.No. 737, P.No. 201
SUB WORK NO. 1 ( Transformer Work ) Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(UE), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V 1 core 95 sq. mm. aluminium conductor complete erected with lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & erecting end pole D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100mm x 116 mm x 11 m Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 400 Amps as incomer & 6 Nos.200 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete.
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).
Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Supplying, installing, testing & commissioning 3 phase, 22/0.433 kV, 50 Hz., 160 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40℃ by thermometer in oil and 45℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer) off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 704 Watts at 50% load, 2048 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL.
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.
Providing and making second class Burnt Brick masonry with conventional /I.S. type bricks in cement mortar 1:6 in foundation sand plinth of inner walls /in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
Making cement concrete foundation including excavation (60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles)
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
SUB WORK NO. 2 ( D.G. Set ) Supplying, erecting, testing and commissioning of diesel generating set with alternator of 125 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 21.4 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 230 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 100 kVA up to 125 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. (WITH NOTE )
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).(3.8*1.5)
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. (3.8*1.5*0.3)
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying, installing, testing and commissioning FR, XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 &IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
SUB WORK NO. 04 ( Internal E.I. ) Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & laying HMS PVC conduit 32 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(WITH NOTE 3)
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(WITH NOTE 3)
Supplying and erecting mains with 4x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(WITH NOTE 1)
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(WITH NOTE 3)
Supplying and erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(WITH NOTE 1)
Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (WITH NOTE 1)
Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (with note 3)
Supplying and erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (with note 3)
Supplying and erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (with note 1)
LT Cables Supplying, erecting & terminating XL HFFR insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XL HFFR insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Point Wiring Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type bell-push with indicator 2 modules 6A /10A, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type buzzer 220 / 250V, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW
Supplying and erecting Electronic type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply.
Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan.
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Light Fittings & Fans Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips omplete with 3 years warranty.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 25 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner
Supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM with speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin 5A. plug top complete with moisture proof treatment and ‘E’ class insulation.
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
WATER COOLER & UPS Supplying and erecting storage type water heater 25 litres capacity having standing loss <0.511kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal function cut-out, valve) with total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete. specification no. AP-WH/STWH
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave with backup time of 1.5 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Distribution Boards with RCCB, MCB & MCCB Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 12 poles, on iron /GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 poles for incoming and 10 poles for outgoing SP MCB’s on iron/ GI frame as per specification no. SW- SWR/MCBDB
Providing, erecting and commissioning 2 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 16/ 25A complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying, erecting & commissioning 4 pole RCCB 100A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
APFC & Cable Trays Supplying and erecting 50 kVAr, 3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
EARTHING SCHEDULE Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.
Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB
Supplying and erecting panel mounting type digital voltmeter having three and half digit LED display, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5 ,AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
Supplying and erecting panel mounting type digital ammeter having three and half digit LED display, external CT operated, calibrated for suitable to operate on 500V, 0 to 1000A having accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs and mounting hardware on provided panel complete with calibration certificate from manufacturer.
LIGHTING ARRESTER Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
SUB WORK NO. 05 ( LV System ) TELEPHONE SYSTEM Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connectionsB complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying & erecting 10 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW
Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification No. WG-TW
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete.
Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete.
Supplying, installing, testing & commissioning IP telephone instrument as per specification complete.
NETWORKING SECTION Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying, installing and testing UTP connector (RJ-45) as per specification No.WG-NAS/UTPC.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected.
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and fixing 2 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 12U wall mount rack (Dimension-DxWxH – 500x600x635 mm) as per specification No. WG-NAS/RAK
Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 0.5 hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete
SUB WORK NO. 06 ( Lift ) Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.
SITC of Electric Traction Passenger cum Stretcher/ Hospital Lift with Rated capacity :- 15 Passenger/1020Kg · Floors :- G+1 floor (2 Stops/2 Landings) · Travel :- 8 mtrs · Location of Lift Machine:- MR/MRL [applicable for Passenger Lift with MRL only & Stretcher/Hospital Lift with MR & MRL] · Rated speed :- 1.0 mps VS · Car/Landing door clear opening of 800 mm wide x 2000mm high · Clear Car size of 1000 mm wide x 2400 mm deep x 2250mm high · Lift shaft available having clear size of 2200 mm wide x 3000 mm deep, 1500 mm Pit depth, 4800 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days min. with 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
SUB WORK NO. 07 ( Fire Fighting System ) Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.( with note 2)
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with ecessary coupler plates & hardware.
Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1600 to 1800 LPM at 70 to 55 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 30kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 1600 to 1800 LPM at 70 to 50 m head driven by 45 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine, exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, screen of SS end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 100 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting 150 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting 200 mm dia. cast iron double flange sluice valve complete with PN16 pressure rating, as per specification no. FF-VL/SV
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 200 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting stainless steel double outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ
Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting M.S./CRCA cabinet for housing Fire Brigade /SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
Supplying and erecting 20/25 mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF AFAS/SD
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051 Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
Supplying, erecting, testing and commissioning rust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete.
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
Supplying and installing auto glow (Viewing up to 15 mtr length) fire signages in PVC/Vinyl 4/6mm thick sheet or as per sample approved by client viz fire hydrant,fire hydrant,fire extinguishers,fire exists,fire door,fire hose box,fire & Electrical & safety etc size 300mm* 100 mm(Rates are taken from previously sanctioned estimate D1104512022-23 Mumbai subdivision vide letter no 173/2022-23 )
Supplying and installing auto glow (Viewing up to 15 mtr length) fire signages viz fire hydrant,fire hydrant,fire extinguishers,fire exists,fire door,fire hose box,fire & Electrical & safety etc size 450mm* 150 mm (Rates are taken from previously sanctioned estimate D1104512022-23 Mumbai subdivision vide letter no 173/2022-23 )
SUB WORK NO. 08 ( Water Pump ) Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, fixing and commissioning MCB type change over switch 4 pole, 25A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete.
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB
Supplying and erecting 525 V 3 phase, 50 Hz., MPP type capacitor having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of metalised polypropylene condensers (MPP) with the standard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee.
Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 120 to 390 LPM discharge at 55 to 11 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP
Supplying & erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.
Supplying & erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos)
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
Supplying & erecting flat flexible 3 core 1.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying, installing, testing and commissioning FR, XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete.
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.
Supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete.
SUB WORK NO. 09 ( Air Conditioning System ) Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC
Supplying, installing, testing & commissioning split type room air conditioning unit 2.5TR to 2.7TR capacity with refrigerant R32 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/WAC
Supplying, installing, testing & commissioning split type room air conditioning unit 2.8TR to 3.2TR capacity with refrigerant R32 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete.
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete.
Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system.
Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
SUB WORK NO. 10 ( Solar Water System ) Supplying, installing, testing and commissioning of ETC solar water heating system without heat exchanger type of 500 LPD capacity with SS water tank of 0.5 mm thickness conforming to IS1239 Part-I :2004 complete as per specification no. ESD-SHWS-ETC
Supplying and erecting GI pipe 25 mm dia B class 4.05 mm thickness with resin bonded flap rock wool /glass wool insulation, with necessary material as per specification No. ESD-HWP/TGP
Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
Supplying and erecting 40/50 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
Providing and fixing high-density polyethylene (HDPE) container one piece moulded triple layer water tank made out of high density polyethylene and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity up to 20000 litres.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting non return valve 25 mm dia in position made of gun metal complete.
SUB WORK NO. 011 ( Transformar for Staff Qtr ) Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(UE), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V 1 core 95 sq. mm. aluminium conductor complete erected with lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & erecting inline cut point end pole D. P. Structure for 11/0.415 kV, 100 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 200 Amps as incomer & 6 Nos.100 Amps Kitkat /MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box, Transformer Belt etc. as per drawing (min. 176 Kg. iron work) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete.
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).
Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Supplying, installing, testing & commissioning 3 phase, 22/0.433 kV, 50 Hz., 100 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40℃ by thermometer in oil and 45℃ by the resistance method in winding at full load rating, with HV tapping (with off load tap changer) off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 499 Watts at 50% load, 1733 Watts at 100% load as per IS:1180(part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL.
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.
Supplying and erecting triple pole mini feeder pillar with 500V, 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP
SUB WORK NO. 012 ( Internal E.I. for Staff Qtr ) Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & laying HMS PVC conduit 32 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(WITH NOTE 3)
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(WITH NOTE 3)
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(WITH NOTE 3)
Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW (WITH NOTE 3)
Point Wiring Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type bell-push with indicator 2 modules 6A /10A, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW
Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan.
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Light Fittings & Fans Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Distribution Boards with RCCB, MCB & MCCB Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 poles for incoming and 10 poles for outgoing SP MCB’s on iron/ GI frame as per specification no. SW- SWR/MCBDB
Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB
LT Cables & End Termination Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
LIGHTING ARRESTER Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
EARTHING SCHEDULE Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 &IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Spectrum Infrastructure
Harsh Constructions Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid