Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹90.9 LAccepted-AOC PLOT NO G 36 SECTOR 20 NAVI MUMBAI 400614 | THANE | MAHARASHTRA | 400614 | 1 | Accepted-AOC Lowest tenderer | |
| 2 | 2₹94.2 L+₹3.3 L (3.67%)Rejected-Finance NORTH SITE TROMBAY MUMBAI 400 085 | MUMBAI SUBURBAN | MAHARASHTRA | 400085 | 2 | Rejected-Finance Being other than lowest |
Tender Value
₹82 L
EMD Value
₹1.5 L
Closing Date
2 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sr DDG and CE
Director General Naval Project (MB) Naval Dockyard SBS Road Mumbai 400023
PROVISION OF 400 BAR HP AIR STATION AT A-13 BUILDING (INS VAJRABAHU) AT NAVAL DOCKYARD MUMBAI
2021_MES_416509_1
8518_1
Open Tender
Civil Works
Lump-sum
365 days
NAVAL DOCKYARD MUMBA
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
DGNP Mumbai
₹1.5 L
Yes
9 Jun 2021
28 Jan 2021
9 Apr 2021
28 Jan 2021
2 Apr 2021
19 Mar 2021
90 days
Amount
Lump sum price worked out by the contractor for “BUILDING WORK ” as listed in Schedule ‘A’ Part I
Lump sum price worked out by the contractor for “SITE CLEARANCE,EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the contractor for “INTERNAL ELECTRIFICATIONS” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the contractor for “RCC DUCT” as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the contractor for “HARD STANDING AND AREA DRAINAGE” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY AND FIRE FIGHTING ” as listed in Schedule ‘A’ Part VI
SCHEDULE 'A PART VII ( MISC B/R AND E/M WORKS Preparation of newly untreated steel surfaces of any description, applying two coats of anticorrosive epoxy paint over a coat of primer including preparation on all steel surface etc complete all as specified and directed.
Fire extinguisher CO₂ type 4.5 kg ISI marked all as specified and as directed by Engineer in Charge.
Fire extinguisher DCP type 6.0 kg ISI marked all as specified and as directed by Engineer in Charge..
MCB, SPN, "C" curve,230 volts, 50 Hz, 63 Amps, 10 KA, ISI marked complete all as specified and directed.
MCB, SP, "C" curve, 230 volts, 50 Hz, 6-32 Amps, 10 KA, ISI marked complete all as specified and directed .
Exhaust fan, 450 mm Sweep,1400 RPM, single phase 230/240 volts AC,50 Hz with louvers & shutters and all accessories pre-wired and including connecting up with twin core twisted flexible copper cable with suitable size complete all as specified and directed.
40 W LED batten light complete with all accessories pre wired and including connecting with twin core,twisted flexible Copper conductor cable of size 1.5 sqmm from ceiling rose to light fitting all as specified and directed by Engineer in Charge. Model : Bajaj make Cat No. BLTRU 40W WH VIVA or euivalent make of Philips / Crompton.
20 W LED batten light complete with all accessories pre wired and including connecting with twin core,twisted flexible Copper conductor cable of size 1.5 sqmm from ceiling rose to light fitting all as specified and directed by Engineer in Charge. Model : Bajaj makeCat No. BLTRU 20W WH VIVA or euivalent make of Philips / Crompton.
30W LED security / street light complete with all accessories pre wired and including connecting with twin core,twisted flexible Copper conductor cable of size 1.5 sqmm from ceiling rose to light fitting, suitable size MS clamps and brackets for supporting light fitting complete all as specified and directed by Engineer in Charge. Model : Bajaj make Cat No. BCLST 30 W LED or euivalent make of Philips / Crompton.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specifiedd and as directed.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground levelat any type of strata) with top edge of earth plate not less than 1.5 meters below ground level connected by 32 X 6 mm GI strip as earth lead by means of brass nuts and bolt,thimbles, check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20 mm graded stone aggregate,with fair finish,internal surface of concrete chamber shall be given internal dia 300mm x 300 mm ,15 mm thick plaster in CM 1:4,funnel with wire mesh ,RCC pit cover of 320 x 320 x 80 mm size (1:2:4) Type B1 using 20 mm graded stone aggregate reinforced with XPM and charcoal ,dust and common salt all as shown in electrical plate No 3 of MES SSR Part -1 (2009) and specified including and provision of GI strip upto 7.5 mtr long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade ,including all excavation and earth work and connecting the earthing strip to panel including testing on completion complete all as specified and directed. by Engr-In-Charge. ( for main LT panel) Note: (1) RCC pit cover shall be precast of RCC (1:2:4) type B1, 80 mm thick reinforced with XPM weighting not less than 4 kg/Sqm in lieu of CI cover. (2) Cost of additional GI strip more than 7.5 meter will be measured and paid seperately under relevant item
Material and Labor for Design,Supply, Fabrication, Installation, testing and Commissioning factory made, MCCB, indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts,3 phase and neutral, 50 Hz AC supply system, made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLS cable of adequate size (minimum 1.5 sq mm ), required civil works/anchoring bolts for grouting, PCC foundation etc with and including following:- a) MCCB 400 Amps, 35 KA ,50 Hz adjustable overload ,adjustable short circuit pritection ,Ics=100%Icu (1 Sec) - 01 No (b) RYB incomer supply indicator lamp LED type -01 set with MCB for control.
Material and Labor for Design,Supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, indoor type, totally enclosed, dust and vermin proof, suitably ventilated, floor mounted, 415 volts,3 phase and neutral, 50 Hz AC supply system, fuly compartmentalized front openable , made out of 2 mm thick CRCA sheet steel, protection of enclosure IP- 54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work/support made out of suitable size of angle iron/flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded Copper conductor FRLSH cable of adequate size (minimum 1.5 sq mm ), required civil works/anchoring bolts for fixing, PCC foundation etc with and including following:-
(iii) Phase Indication lamps (RYB) LED type- 01 no ( Set of three) (iv) MCB SP 2 Amps,"C" series for control protection RYB phases (set of 3 ) - 01 set OUT GOING a) MCCB 4 pole 200 Amps, 35 KA, Ics=100%Icu),50Hz thermal magnetic setting 0.8 to 1.0, adjustable short circuit setting 6-10 - 02 Nos (for compressors) b) MCB SPN, 230 volts, 50 Hz, 63 Amps,10KA, 'C' curve - 01 No ( for 8 way SPN DB). Notes for Item No 1.18 &1.19- 1. Panel manufacturers should have in house powder coating plant with minimum 8 tanks pre treatment of MS sheet facilities, dust free spray paint booth. (8 tanks pre treatment process includes: degreasing / water rinsing / de-rusting / water rising / activation / phosphating / water rinsing / passivation). 2. Thickness of powder coating shall not be less than 80 microns and test certificate for poder coating shall be furnished along with LT panel. 3. The panel manufacturer should have following certification: (i) CPRI certification Degree of protection IP-54 (should have IEC:61439 as applicable.
(ii) CPRI certification short circuit withstand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA. (iii) CPRI certification rated current for short circuit not less than 5000A 4. MCCB/ACbs provided should be capable for on line setting of current. 5. All electrical switch gear like MCCBs,MCBs and ACbs should be of same make. 6. Drawing of panel board should be got approved from GEbefore fabrication. 7. panel board shall be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2.
RENJIN CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .