Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 CrAccepted-AOC PANCHAYAT COLONY G EXTENSION NAHARLAGUN DISTRICT PAPUMPARE ARUNACHAL PRADESH 791110 | NAHARLAGUN | PAPUMPARE | ARUNACHAL PRADESH | 791110 | ₹27.4 Cr Quoted ₹27.5 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹28.6 CrRejected-AOC | ₹28.6 Cr | L2 | Rejected-AOC Not lowest |
| 3 | L3₹46.5 CrRejected-AOC | ₹46.5 Cr | L3 | Rejected-AOC Not lowest |
| 4 | L4₹50.1 CrRejected-AOC 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹50.1 Cr | L4 | Rejected-AOC Not lowest |
| 5 | L5₹50.6 CrRejected-AOC CITY TOWER BUILDING ROOM NO 306 CIRCULAR ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | ₹50.6 Cr | L5 | Rejected-AOC Not lowest |
| Sl No | Description | Qty | Unit | ASHIS DHAWA L2 | HTE INFRA LLP L3 | D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED L4 | M/S ALLIED CONSTRUCTION L5 | M/s Yarkum Agency L1 |
|---|---|---|---|---|---|---|---|---|
| 0.00NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. | ||||||||
| 1.10 | Lumpsum price workedout by the tenderer for BUILDING & STRUCTURE WORKS as listed in Schedule ‘A’ Part-I(A) | 1 | Lump-sum | 18,75,00,000 ₹18.8 Cr | 34,60,37,500 ₹34.6 Cr | 37,39,39,290.43 ₹37.4 Cr | 38,79,52,040 ₹38.8 Cr | 18,00,00,000 ₹18 Cr |
| 1.20 | Lumpsum price workedout by the tenderer for CAST-IN-SITU PILE as listed in Schedule ‘A’ Part-I(B) | 1 | Lump-sum | 21,74,650 ₹21.7 L | 22,60,490 ₹22.6 L | 23,61,233 ₹23.6 L | 24,74,992.5 ₹24.7 L | 19,00,000 ₹19 L |
| 2.00 | Lumpsum price workedout by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II | 1 | Lump-sum | 44,62,000 ₹44.6 L | 25,51,500 ₹25.5 L | 30,10,356 ₹30.1 L | 34,28,673 ₹34.3 L | 37,00,000 ₹37 L |
| 3.00 | Lumpsum price worked out by the bidder/ tenderer for MISC ITEMS - I as listed in Schedule 'A' Part-III. | 1 | Lump-sum | 24,89,900 ₹24.9 L | 36,52,500 ₹36.5 L | 36,01,220 ₹36.0 L | 37,73,675 ₹37.7 L | 20,00,000 ₹20 L |
| 4.00 | Lumpsum price worked out by the bidder/ tenderer for FIRE FIGHTING SYSTEM as listed in Schedule 'A' Part-IV | 1 | Lump-sum | 29,58,500 ₹29.6 L | 43,44,681 ₹43.4 L | 53,27,567 ₹53.3 L | 47,01,648 ₹47.0 L | 26,00,000 ₹26 L |
| 5.00 | Lumpsum price worked out by the bidder/ tenderer for FIRE ALARM SYSTEM as listed in Schedule 'A' Part-V. | 1 | Lump-sum | 47,04,500 ₹47.0 L | 61,93,907 ₹61.9 L | 1,00,31,797 ₹1.0 Cr | 58,26,786 ₹58.3 L | 39,00,000 ₹39 L |
| 6.00 | Lumpsum price worked out by the bidder/ tenderer for LIGHTNING PROTECTION as listed in Schedule 'A' Part-VI. | 1 | Lump-sum | 59,31,250 ₹59.3 L | 51,84,700 ₹51.8 L | 71,91,744 ₹71.9 L | 54,99,828 ₹55.0 L | 46,00,000 ₹46 L |
| 7.00 | Lumpsum price worked out by the bidder/ tenderer for AUTOMATIC SPRINKLE SYSTEM as listed in Schedule 'A' Part-VII. | 1 | Lump-sum | 3,88,000 ₹3.9 L | 5,97,000 ₹6.0 L | 7,68,813 ₹7.7 L | 5,65,212 ₹5.7 L | 4,00,000 ₹4 L |
| 8.00 | Lumpsum price worked out by the bidder/ tenderer for ROAD / PATH / CULVERT / HARDSTANDING as listed in Schedule 'A' Part-VIII. | 1 | Lump-sum | 4,12,25,000 ₹4.1 Cr | 5,84,31,600 ₹5.8 Cr | 5,64,48,612 ₹5.6 Cr | 5,62,70,707.6 ₹5.6 Cr | 3,80,00,000 ₹3.8 Cr |
Updated dates
Tender Value
₹32.2 Cr
EMD Value
₹15 L
Closing Date
25 Dec 2025, 6:00 pmClosed
CE SHILLONG ZONE
CE SHILLONG ZONE SPREAD EAGLE FALLS, SHILLONG MEGHALAYA 793011
PROVISION OF TECHNICAL STORAGE SHED AT NARANGI UNDER GE GUWAHATI
2025_MES_732667_1
89774/GUA/E8
Open Tender
Civil Works
920 days
NARANGI
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,000
₹15 L
19 Mar 2026
25 Sept 2025
29 Dec 2025
25 Sept 2025
25 Dec 2025
11 Dec 2025
Amount
NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Lumpsum price workedout by the tenderer for BUILDING & STRUCTURE WORKS as listed in Schedule ‘A’ Part-I(A)
Lumpsum price workedout by the tenderer for CAST-IN-SITU PILE as listed in Schedule ‘A’ Part-I(B)
Lumpsum price workedout by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the bidder/ tenderer for MISC ITEMS - I as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the bidder/ tenderer for FIRE FIGHTING SYSTEM as listed in Schedule 'A' Part-IV
Lumpsum price worked out by the bidder/ tenderer for FIRE ALARM SYSTEM as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the bidder/ tenderer for LIGHTNING PROTECTION as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the bidder/ tenderer for AUTOMATIC SPRINKLE SYSTEM as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the bidder/ tenderer for ROAD / PATH / CULVERT / HARDSTANDING as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule 'A' Part-IX
Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule 'A' Part-X
Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule 'A' Part-XI
Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule 'A' Part-XII
Lumpsum price worked out by the bidder/ tenderer for INTERNAL WATER SUPPLY as listed in Schedule 'A' Part-XIII.
Lumpsum price worked out by the bidder/ tenderer for DEMOLITION OF BUILDINGS as listed in Schedule 'A' Part-XIV.
Sch 'A' Sec-XV (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Rough excavation and bringing approved earth (as approved by Garrison Engineer) from sources outside defence land including cost of earth, royality if any, transportation, taxes for area filling/forming embankments including raising (any height from EGL)/lowering by approved earth and including raising earth spreading in layers not exc 30 cm thick each layer,watering, compaction with 8 tonne to 12 tonne power roller and finished to required size and shape etc,any high from EGL complete all as specified and directed. Note: . (i) Earth required for the item, shall be supplied by contractor, from out side MOD land at his own arrangment. (ii) All cost of procurement of earth including cost of transportation, roualties, taxes etc. shall be deemed to be included in the unit rate quoted by the contractor. (iii) With referance to clause 3.6 of MES schdule Part-II on serial page No 18 it is clarified that measurement of the above item shall be of finalised embankment/traverse of filled earth after consolidation and 10% deduction shall be made from measured and calculated volume to allow for increase in bulk.
S&F LED Bulb 9 Watt ,230 Volt, 50 Hz suitable for batten holder complete all as specified and directed.
S&F LED building security light fitting of 25 Watt, including LED lamp complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece, high pressure die cast aluminium alloy, monolithic construction totally enclosed, dust and water proof with minimum IP65 protection as per IS-10322-1982(Part-I) with latest amendments and input voltage range 140-300 VAC, frequency 50-60Hz, P.F should be more than 0.9 with THD(I) less than 10%, cool white color and. Fitting should be provided with min 4 KV surge protection, constant current constant voltage driver, high voltage withstanding capacity upto 300 VAC and also have double phase protection, no load, open circuit and short circuit protection, Light fitting suitable for ambient temperature from minus 10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure minimum IP65 degree protection. The lumen output shall not be less than be 110 lumens per watt, life should not less than 40Khr, color index 6000K and must be certified by the relevant test report Fitting should fixed on pole using and including 1.2m long 32 mm or 25 mm dia GI pipe light grade bend to shape and fixed using two nos clamps fabricated using MS Flat iron 40x5mm including necessary nut bolts and washers and making all electrical connection complete all as specified and directed
S&F blanking plate suitable for fixing in MCB DB complete all as specifified and directed.
S&F Flameproof rotary switch weatherproof 16 Amps, single pole with separate terminal chamber made in die cast Aluminium alloy LM6 with IP66 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete all as specified and as directed. Make: Sudhir/ Bharat/ Crompton or equivelent makes. NOTE: 5 Nos flame proof lights shall be controlled by one flame proof rotary switch complete all as specified and directed..
S&F Flameproof switch socket & plug combined, weatherproof 16/20 Amps DP with 3 pin plug top with separate terminal chamber made in die cast Aluminium alloy LM6 with IP66 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete all as specified and directed.
S&F Flameproof / weather proof MCB Distribution board SPN 10 way made in die cast Aluminium alloy LM6 with IP65 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete with and including internal bus bar & wiring up to terminal complete all as specified and directed.
S&F Surge protection device (SPD) single phase and neutral, 16 KA, T1+T2- limp 8 kA per pole fixed in distribution board and making connections complete all as specified and directed. (for flameproof SPN DBs).
S&F Flameproof, weatherproof LED Bulk Head light 30 Watt having flying saucer design with 120 degree beam angle lens , 6500K with 120LM/watt & LED driver made in die cast Aluminium alloy LM6 with IP65 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete all as specified and directed.
S&F Flameproof, weatherproof LED wellglass light 45 Watt having flying saucer design with 120 degree beam angle lens , 65000 K with 120LM/watt & LED driver made in die cast Aluminium alloy LM6 with IP65 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete all as specified and directed.
S&F Flameproof, weatherproof LED tube light 1x18 watt 4 feet including tube rode 18/20 watt and cable entries and stopping plugs, made in die cast Aluminium alloy LM6 with IP65 ingress protection with all stainless steel and painted with epoxy based powder coated structured paint shade as per IS:5-631 having temp class T6 certified by CIMFR (Central Institute of Mining and Fuel Research) & PESO (Petrolium and Explosives Safety Organization) complete all as specified and directed.
M&L for white laminated boards 3 feet x 2 feet including necessary aluminium frame work complete all as specified and directed.
S&F Ready made grass turf (with minimum 5cm of soil covering the grass roots and obtained from any source outside defence land and laid in slope of traverse) complete all as specified and directed.
Supply, laying, connection and testing 400 mm bore, ductile iron pressure pipe centrifugaliy cast (spun) with spigot and socket ends, class K-9 and confirming to IS 8329-2000 with push on rubber gasket jointing inside with cement mortar lining and outside zinc coating with finishing layer of back bitumen / blue epoxy coating duly ISI marked in any length laid in trenches complete all as specified and directed.
S&F 400 mm dia, PN 1.6 rated CI Sluice valve, conforming to IS 14846: 2000, having CI body, wedge, bonnet, stuffing box, gland, handwheel, thrust plate, GM body ring, wedge ring, wedge nut, CS bolts & nuts, SS stem, flange drilling standard end connection conforming to IS 1538: 1993, etc. along with necessary accessories complete as as specified and directed.
S&F 250 mm bore , PN 1.6 GI Puddle Flange designed & manufactured as per IS 1560-3.1 & BS 4504 for suction of fire pumps from water tank all complete all as specified and directed
Supply, Install, Testing and commissioning of a remote annunciator with supervised wireless link to the FACP, showing Alarm / Supervisory / Fault with zone / device text. Polling interval ≤10s; loss-of-comms trouble ≤60s. Back - lit LCD, LEDSs (Alarm, Supervisory, Fault, Power, Link), internal buzzer (≥75 dB @ 1 m) with silence key as permitted. Power 230 V AC with charger and batteries sized for ≥ 24 h standby + 30 min alarm. Enclosure IP54 for indoor brigade room. Provide mounting hardware, pairing, signal survey, labels, and commissioning records complete all as specified and directed.
S&F Data line Surge Protection Device (SPD) sitable for RS-485, two stage, replaceable Modules, single phase and neutral, T2 -limb, Imax 20 KA per pole complete fixed in FACP & Repeater Panel and making connections complete all as specified and directed
M & L flame retardant low smoke & low halogen fire alarm armoured cable having stranded class 2 copper conductor conforming to EN60228, insulated with XLPE type GP8 conforming to BS 7655-1.3. extruded inner sheath with PVC conforming to BS 5467, armoured with galvanized steel round wire and sheathed with extruded FRPL PVC conforming to BS 5467, suitable for voltage rating 600/1000V, maximum operation temperature 90°C, maximum conductor temperature at short - circuit 250°C, Red in colour, including laying, termination and ferruling complete as specified and directed.(For Repeater Panel)
S&F perforated hot dipped galvanized iron Cable tray of size 100 X 50 X 1.6 mm, having galvanization thickness not less than 50 microns and perforation not more than 17.5% including fittings viz, joints, bends, tees, etc, in convenient sections of length complete including cable tray supports and associated accessories, all as specified and directed
M&L for Loop in loop out cable junction box of FRP weather proof for outdoor installation of size 155 mm x 210 mm x 92 mm suitable for 10-16 Sqmm cable, and having IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit with terminals , combi climate cable glands of IP 66 / 67 for cable entry and grommets IP 65 for conduit for cable exit with and including 01 No. MCB SP 6 Amps, 10 kA,C curve overload and short circuit protection, terminals as PVC connector heavy duty 32 Amps, 4 way for cable necessary fixing arrangements and with cable glands complete all as specified and directed.
S&F street light bracket arm of length not less than 1.5 m made out of GI tubing, 32 mm bore, light grade fied to pole, etc with suitable size flat iron clamp, nuts , bolts including paintng with two coats of aluminium paint over a coat of red oxide, zonc chrome primer on steel surfaces complete all as specified and directed.
M&L for copper strip size 25x3 mm as earth contunity conductor for main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing as required complete all as specifed and directed.
M&L for Pre-cast RCC LT cable rout indicator with and including necessary PCC and excavation work for grouting/ fixing of route indicator complete all as specifed and directed.
Boring holes under road pavement by bocky manually in any type of soil upto 150 mm bore complete all as specified and as directed.
Supply, Installation, Testing and Commissioning of Outdoor type RTU based Monitoring / Annunciating cum feeder pillar Control Panel of suitable size made out of 1.6mm thick CRCA sheet. The street light control panel shall be able to monitor and control minimum 90 single phase street lights of upto in the circuit of 30 lights of maximum 63W each and shall consist of the following equipments. (i) RTU shall have (commercial grade) minimum 800Mhz processor with 512MB RAM, with suitable Analog Inputs / Outputs and Digital Inputs / Outputs + 20% spare capacity, 02 nos. RS485 communication ports, 1 no. Ethernet port. ModBus and DNP3 compatibility, Aux. supply 24V DC, Program memory backup facility for 180 days, Real time clock, Operating temperature range O to 70·c. with inbuilt GPRS modern (4G enabled with at least 150MBPS speed) with suitable external antenna, capable of sending data remotely and SMS as well; including the cost of communication for 24 months. The RTU shall be NABL certified as per IEC 61010-1 (clause 6.8}-Dielectric and IEC 60255-27 (clause 10.5.3) -Impulse testing. (Make: Schneider, Siemens, GoPower, RightWatts, Regin) The RTU shall have a remote webpage for operation; the remote webpage shall have capability to integrate 50 such RTUs. The webpage standard design shall be capable of controlling street Lights using a web link over Internet connection.
Supply, Installation, Testing & Commissioning of multifunction meters with RS485 for mounting on main distribution panel using existing current transformers. The meter shall be of acc cl 1.0 and shall be able to record V, A, KW, KWh, PF, F. In addition, All meters shall also be able to record THD (current and voltage) with all wiring cabling, cutting of cabinets, complete all as specified and directed.
Supply, Installation, Testing & Commissioning of LT current transformer of Rishabh/ AE for rating upto 20A suitable for above meter and the street lighting panel, along with all cabling arrangement complete all as specified and directed.
Supply, Installation, Testing & Commissioning of Android App to control and monitor street lighting loops (including OFF/ ON, Status, energy consumption, 20 parameters from multifunction meter) on hourly basis alongwith real time alerts (within 10 seconds) complete all as specified and directed.
Supply, installation, testing and commissioning electrical LT Feeder Pillar Box, outdoor cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 3.15 mm thick with 2 mm thick for internal compartment duly powder coated fixed on angle iron pedestal mad eout of 50x50x6mm with cable chamber for individual feeders for incoming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventilation including suitable size of cable entry, copper bus bar suitable for 250 Amps current carrying capacity with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCB,s (intake point) will be carried out with TPN copper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeves and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 mtr height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal complete all as specified and directed by the Engg-in-charge ( Feeder piller box shall be consisting of the following):- (a) MCCB 200 Amps 4 pole 50 Hz 415 volts, Ics = 100 % Icu, with thermal magnetic release having rupturing capacity 25 KA- 1 No. ( As incommer). (b) MCCB 20 Amps 3 pole 50 Hz 415 volts, Ics = 100 % Icu, with adjustable overload setting having rupturing capacity 18 KA- 10 Nos. ( Outgoings). (c) 3 Phase digital multifunction meter model "A" class 0.5, 5 Amps with relay - 1 No. (d) Indicating lamp 240 Volts LED type - Set of three (RYB).
Supply, installation, testing and commissioning electrical LT Feeder Pillar Box, outdoor cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 3.15 mm thick with 2 mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6mm with cable chamber for individual feeders for incoming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventilation including suitable size of cable entry, copper bus bar suitable for 200 Amps current carrying capacity with suitable connections from MCCB out going to main bus bar shall be carried out with TPN copper bus bars of suitable rating and connections from main bus bar to out going MCCB,s (intake point) will be carried out with TPN copper bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeves and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 mtr height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal complete all as specified and directed by the Engg-in-charge ( Feeder piller box shall be consisting of the following):- (a) MCCB 63 Amps 4 pole 50 Hz 415 volts, Ics = 100 % Icu, with thermal magnetic release having rupturing capacity 25 KA- 1 No. ( As incommer). (b) MCCB 20 Amps 4 pole 50 Hz 415 volts, Ics = 100 % Icu, with adjustable overload setting having rupturing capacity 18 KA- 02 Nos. ( Outgoings). (c) 3 Phase digital multifunction meter model "A" class 0.5, 5 Amps with relay - 1 No. (d) Indicating lamp 240 Volts LED type - Set of three (RYB).
M&L for LLDPE 10 user septic tank designed to carry sewage and sullage water including execavation in any type of soil , PCC (1:4:8) type D2 below foundation,vent shaft,connection complete all as specified and directed
M&L for soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 Concrete, including intercepting chamber, screen chamber made of Brick masonry in cement morter, RCC cover slab in M-25 / SFRC cover interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 m dia X 3.0 m effective depth complete all as specified and directed.
Boring for Bored cast in situ piles of dia 450 mm and 11 metre long in soil and getting out and disposal of spoil to a distance not exceeding 50 metres using DMC method (Direct mud circulation) complete all as specified and directed.
M&L for reinfored cement concrete M-30 Design mix (using 20 mm graded crushed stone agrregate) as in cast-in-situ bored pile from cut off level excluding HYSD bars for reinforcement, but including temporary metal sheating upto 1.5m provided as guide, cost of all materials mixing, laying with mechanical vibrators, ramming, consolidating, finishing and curing etc. and vertical load (cyclic) as per ISI specification; complete all as specified and directed. Note: The rate include for wastage allowance of 1.5m from cut off level due to inter mixing of clay slurry with concrete.
Carrying out initial pile load tests for 450 mm dia pile by anchor reaction method as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed.
Conducting low strain integrity test on required diameter RCC cast-in-citu piles, data analysis and submission of report. (min 10 piles per visit) complete all as specified and directed.
Carrying out routine pile load tests for 450 mm dia pile by anchor reaction method as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed.
ASHIS DHAWA (BID ID -3501408)
HTE INFRA LLP (BID ID -3501481)
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED (BID ID -3501568)
M/S ALLIED CONSTRUCTION (BID ID -3507446)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.74 MB
1CONTENTS_TENDER.pdf
Tender Documents • 3.71 MB
BOQ_820337.xls
BOQ • 0.50 MB
14FAD_merge.pdf
Additional Documents • 8.65 MB
Download all tender documents and submit your bid