Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance INDEX NO B 33 NC R O KRALPORA DISTT BUDGAM SRINAGAR J K 190019 | SRINAGAR | BUDGAM | JAMMU AND KASHMIR | 190019 | Admitted-Finance |
| 2 | Admitted-Finance 15 BAGHE ISLAM NEAR NH BY PASS BRIDGE LAL NAGAR CHANAPORA SRINAGAR JAMMU KASHMIR 190015 | SRINAGAR | JAMMU AND KASHMIR | 190015 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE 970 EWS C/O 56 APO PIN 913970
REPAIR AND MAINT OF INTERNAL WIRING, INCL ELECTRIC FITTINGS, FIXTURES AND CONNECTED ITEMS IN OTM AND MD ACCN AT JAKLI RC UNDER GE 970 EWS
2023_MES_606169_1
GE 970 EWS-20/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 970 EWS C/O 56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹60,000
Yes
25 Jul 2023
28 Jun 2023
21 Jul 2023
28 Jun 2023
19 Jul 2023
12 Jul 2023
Amount
Taking down old and unserviceable submain wiring any size of two core including earth wire complete including batten/ conduit and make good the disturbed surface to match the existing surface complete all as directed
Taking down old and unserviceable alumunium point wiring in batten/ conduit and make good the disturbed surface to match the existing surface, complete all as specified and directed by Engr-in-charge.
Taking down old and unserviceable, distribution board any type including/ sheet metal enclosures, after removing all connection and make good the disturbed surface all as directed by Engr-in-chanrge
M&L for Point wiring using FRLS-H PVC insulated unsheathed, multistranded copper conductor cable 1.5 sqmm drawn through and including PVC conduit of min 20 mm dia by Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc fo concealed conduit wiring with modular flush box metal of GI sheet minimum 1.8 mm thick with earth terminal for safety, flush metal GI box of required modules as per site requirement and modular plate with support frame white in colour of required modules, 3mm thick including all fittings i.e. tees, bands and junction boxes, screws etc. complete for One light/Fan point controlled by one switch 6 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sq mm earthing) Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. Note:- (a) wiring shall be done by using colour coding (b) Earth wire shall be of green colour. (Make:-Finolex/Grandlay/Polycab/ L&T/KEI/Havells)
All as item No 4 above One 3 pin socket outlet, 5 Amp socket outlet on same board with other switches.
All as per item No 4 above but One 3 pin switch socket outlet, 5 Amp on independent board.
All as per item No 4 above but one 3 pin 15 Amps socket outlet independent but below the switch board of light points in the same vertical plane, using FRLS-H PVC insulated unsheathed, multistranded copper conductor cable 2.5 sqmm drawn through and including PVC conduit of min 20 mm dia by Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc for concealed conduit wiring with modular flush box metal of GI sheet minimum 1.2 mm thick with earth terminal for safety, flush metal GI box of required modules as per site requirement and modular plate with support frame white in colour of required modules, 3mm thick including all fittings i.e. tees, bands and junction boxes, screws etc. complete for power point controlled with cables, 2.5 sq. mm size, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. (2.5 Sqmm for Phase and neutral and 2.5 Sqmm for earthing) (Make:-Finolex/Grandlay/Polycab/L &T/KEI/Havells)
All as per item No 4 above but One light point controlled by two 2-way switches, with cables 1.5 sq. mm size.
Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC casing & caping on surface of wall, not less than 25mm width confirming to IS 9537 (Part-III) 1983, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box with 1.8 mm wall thickness, of suitable size for modular type switch with cover plate & frame, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green) (Make:-Finolex/Grandlay/Polycab/L &T/KEI/Havells)
As per item No 9 above but One 3 pin 5 amps switch socket outlet point on independent board complete all as specified and directed. (Make:-Finolex/Grandlay/Polycab/L &T/KEI/Havells)
All as per item No 9 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch. (Make:-Finolex/Grandlay/Polycab/L &T/KEI/Havells)
As per item No 9 above but One bell / buzzer point controlled by one bell push on independent board complete all as specified and directed. (Make:-Finolex/Grandlay/Polycab/L &T/KEI/Havells)
Supply and fixing bell push,flush type 5 Amps complete all as specified and directed. Make : Anchor/Havells
Supply and fixing buzzer dingdong AC 230 Volts, single pole, 50 Hz complete all as specified and directed.
Supply and fixing switch piano 15 Amp, flush type single pole, ISI marked One Way switch omplete all as specified and directed.
Supply and fixing switch piano, flush type single pole, one way 5 Amps 3 pin, ISI marked for the same board complete all as specified and directed.
Supply and fixing socket outlet 3 pin, 15 Amp, flush type , ISI marked complete all as specified and directed.
Supply and fixing socket outlet 2 in 1, 3 pin, 5 amp flush type ISI marked for the same board complete all as specified and directed.
Supply and fixing switch socket combination 5 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed.
Supply and fixing Switch piano, flush type single pole 5 Amps two Way complete all as specified and directed.
Supply and fixing ceiling rose, 3 phase/PVC/polycarbonate, isolated body type complete all as specified and directed.
Supply & Fixing in repair LED lights fitting 18W LED 6000K (4Ft), (Warm/ Warm White) 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as per specified and directed.
Supply and fixing in repair LED light fitting 2 feet, 10 watt 220 V AC (Warm/ White) decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as per specified and directed.
M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVC conduit 20mm dia medium Grade concealed in walls/roof/floors complete all as directed. Notes:- (i) Two wires of 4 sqmm and one wire of 4.0 sqmm and one run of PVC conduit shall be measured as one unit.
M&L for Sub Main wiring complete with copper conductor, multi stranded, FRLS, PVC insulated and sheathed, 6 Sq mm, two run 1100 volts grade, incl drawn through PVC suitable size counduit and 6 Sqmm single run for earthing complete all as directed. Notes:- (i) Two wires of 6.0 sqmm and one wire of 6.0 sqmm and one run of PVC conduit shall be measured as one unit.
M&L for Sub Main wiring complete with copper conductor, multi stranded, FRLS, PVC insulated and sheathed, 10 Sq mm, two run 1100 volts grade, incl drawn through PVC suitable size counduit and 10 Sqmm single run for earthing complete all as directed. Notes:- (i) Two wires of 10.0 sqmm and one wire of 10.0 sqmm and one run of PVC conduit shall be measured as one unit.
Supply and fixing in repair round shape NIMBUS LED PANEL 15 W RD 6500 K (Havells) Round Recess 6500 K 15 watt (Warm/ Warm White) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size completecomplete all as specified and directed. Make : NIMBUS LED PANEL 15 W RD 6500 K (Havells) or equivalent in Bajaj/Philips/GE lighting
Supply and fixing in repair round shape 36 watt 220 volts AC recessed mounting type low depth aesthetically designed LED 2x2 feet flat (Warm/ Warm White) panels, with high efficiency PMMA diffuser soft glare free light (Warm/ Warm White) suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. (Make:-Cat Part No Dominto LED BCTBLR 36W LED FP CW of Bajaj equivalent Havells/Indoasian/Legrand/Philips)
Supply and fixing Sheet Metal enclosure double door for DBs when MCBs to be used TPN-4 Way with 200 Amp rated bus bar complete all as specified and directed.
Supply and fixing Sheet Metal enclosure double door for DBs when MCBs to be used SPN- 8 Way with 200 Amp rated bus bar complete all as specified and directed.
Supply and fixing Sheet Metal enclosure double door for DBs when MCBs to be used SPN- 12 Way with 200 Amp rated bus bar complete all as specified and directed.
Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 Volts complete all as specified and directed.
Supply and fixing in repair 415V 10KA 'C' curve miniature circuit breaker (MCB) TPN and current carrying capacity 63 Amp in the DB complete with connection testing and commissioning . Make: Havells/Legrand/Anchor IN "C' Series(Make: Havells Havells/Legrand/L &T/Indoasian/ABB/Siemens)
Supply and fixing in repair amp rating 240V, 10KA curve miniature circuit breaker (MCB) SPN and current carrying capacity 40 Amps in the MCB DB complete with connection testing and commissioning Make: Havells/Legrand/Anchor IN "C' Series(Make: Havells Havells/Legrand/L &T/Indoasian/ABB/Siemens)
Supply and fixing repair amp rating 240V, 10KA curve miniature circuit breaker (MCB) SP and current carrying capacity 5-32 Amps in the MCB DB complete with connection testing and commissioning (Make: Havells/Legrand/Anchor IN "C' Series(Make: Havells Havells/Legrand/Indoasian/ABB/Siemens)
Supply and fixing in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd at site complete all as per specified and directed.(Make: Havells/Legrand//Indoasian/ABB/Siemens)
Supply and fixing in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply & fix in repair Bulk head fitting energy saving 10 W LED with opal diffuser light fitting including necessary fixing arrangements including LED bulb complete all as specified and directed. Make : Havells/Bajaj/C&S.
Renewal of Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for :-(a) Excavation and earth work or drilling hole for electrode in any type of soil (b) PCC pit in cement concrete 1:2:4 TYPE B-1 (.c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified.(e) 15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead.(f) Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion. (On testing after completion if the desired earth resistance (i.e less than 3 ohms) is not obtained the earthing will be redone at no extra cost)
M/S SMYLE AND CO
M/S RAFIQ AHMAD SOFI AND SONS
G N Constructions
ms new dar water star
M/S Manzoor and Co
M/S Noor Mohammad Shalla
M/S Sultan Enterprises
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .