| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 CrAccepted-AOC | ₹21.6 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹23.0 CrRejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹23.0 Cr | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹27.3 CrRejected-Finance | ₹27.3 Cr | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹29.9 CrRejected-Finance | ₹29.9 Cr | L4 | Rejected-Finance NOT BEING L1 |
Tender Value
₹27.5 Cr
EMD Value
₹15 L
Closing Date
15 Jun 2022, 6:00 pmClosed
CHIEF ENGINEER CG GOA
CHIEF ENGINEER CG GOA 403806
PROVISION OF OTM ACCN AND ALLIED FACILITIES CGAOT AT BANGALORE
2022_MES_517737_1
82080/E8
Open Tender
Civil Works
540 days
BANGALORE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (I) (CG) GOA
₹15 L
Yes
4 Oct 2022
11 Apr 2022
17 Jun 2022
11 Apr 2022
15 Jun 2022
1 Jun 2022
Amount
SCHEDULE "A" Part - I (BUILDING WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II (SITE CLEARANCE, AREA DEVELOPMENT, EXCAVATION & EARTHWORK) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III(INTERNAL ELECTRIC SUPPLY OTHER THAN HANGAR) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLYOTHER THAN HANGAR) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD PATH, CULVERT AND HARDSTANDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (DISPERSAL AREA) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (LIGHTNING PROTECTION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII(DG SET/AVIATION OBSTRUCTION LIGHT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIV (LIFTS) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XV (REFRIGERATION & AC) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XVI (COMPOUND WALL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XVII (FLAG MAST) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XVIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
(iii) The following electric points and fixtures shall be provided inside the hangar: 1. 3 Phase industrial socket 32 A - 06 Nos. 2. 3 Phase industrial socket 63 A with MCB control - 04 Nos 3. 1 Phase industrial socket 32A - 06 Nos 4. 6A/16A socket outlet - 20 Nos 5. Air Circulators 600mm Sweep industrial type self standing/wall mounted -16 Nos. (iv) S& F wind driven turbo ventilators fixed each per 100 sqm (min diagonal 14.5 mtrs) of roof plan area of hanger.The turbo ventilators shall be of average capacity of 1500 to 2000 CFM with neck diameter 700-750 mm and 42 nos fins. Top plate and bottom rings shall be made of high grade stainless steel (SS-304) and fins of high grade aluminium H-140 of minimum thickness 0.71mm. The base of hopper shall be constructed with UV stabilsed FRP of minimum thickness 3 mm matching with roof sheet profile The rate shall be deemed to include fixing of FRP base alongwith ventilator and providing special leak proof tape from all sides making it totaly water tight etc. complete all as specified and driected.
(b) Design and Construction of Annxe bldgs (02 Nos) in G+2 configuration RCC framed constrcution in M-30 design mix, all as shown on drawings, particular specifications and tender documents. Note: Internal electrification and Internal water supply shall be provided all as shown on drawing and shall be measured and paid vide Sch A Part III & IV respectively) NOTE: (i) All item mentioned at Sl. No 18.01, 18.02 & 18.03 are part of lumpsum, irrespective of availibility of such items in any other part of Schedule 'A' (Provisional) (ii) Lumpsum cost of Sl. No 18.01, 18.02 & 18.03 shall be entered against Item No 18.01 (iii) In case of difference in Hangar size (Length, width and height) between BOQ item No 18.01 and size shown in drawing, higher size shall be taken for execution without any additional cost
Design and Construction of Administrative Building in G+2 including parking shed in configuration RCC framed constrcution in M-30 design mix, all as shown on drawings, particular specifications and tender documents. Note: Internal electrification and Internal water supply shall be provided all as shown on drawing and shall be measured and paid vide Sch A Part III & IV respectively)
Design and Construction of Logistics block with MT garage/MT section in G+2 configuration RCC framed constrcution in M-30 design mix mix, all as shown on drawings, particular specifications and tender documents. Note: Internal electrification and Internal water supply shall be provided all as shown on drawing and shall be measured and paid vide Sch A Part III & IV respectively)
Design and Construction of RCC underground sump 200000 litre capacity cum pump house of size as shown in the arch drawing in permanent specifications all as specifed in drawings and tender documents RCC framed construction in M-30 design mix concrete including excavation in soft disintegrated rock, PCC in foundation complete mix all, as shown on drawings, particular specifications and tender documents .Note: Internal electrification and Internal water supply shall be provided all as shown on drawing and shall be measured and paid vide Sch A Part III & IV respectively)
S&F aluminium bird proof mesh (jali) of thickness 2mm and short way mesh (SWM) inner opening 11 mm and long way mesh (LWM) inner opening 50 mm with strand width 3 mm of size, length 6m & width 1.5 m with anodizing 16-18 micron complete all as specified and directed. Note : Weight of bird proof aluminum jali shall be 2.3 Kg/sqm taken for any amendment during execution.
S&F supporting aluminium frame work shall be of panel size 4.0m x 2.0m with main aluminium Tee size 101mm x 45mm x 3.1mm thick & cross aluminium Tee size 40mm x 40mm x 5mm thick complete all as specified and directed.
ROAD/ PATH/ CULVERT/HARDSTANDING: M&L for 150 mm thick WMM in two layers (75mm each layer) , using graded stone aggregate, spread rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller.
M & L for PQC 200mm thick of flexural strength 40 Kg/Sqm in field using 420 kg of cement per cubic meter.
COMPOUND WALL: Supply and fix concertinal coil of 700mm outer dia made out of 2.60mm dia spring steel wire 230 gm (min) dipped with corrosion preventive fluid (rusilo 901) of castrol make including white colouur, each coil having in 50 turns (circles) and an average weight not less than 8.57 kg (plus or minus 5%) including hangle and speke at both ends of coil errected in position on top of mild steel angle by fixing with MS rod for securing including necessary welding/clipping to MS section etc complete all as specified and directed.
DISPERSAL AREA (Item No 18.10 to 18.17): M&L for 200 mm thick (compacted thickness) Granular Sub Base (GSB) using 63 mm stone aggregate Grade-V (75mm -0.075mm) using natural sand, crushed gravel, crushed stone material. Surface to be laid, formedrolled usingvibratory roller of min 80KN weight and consoildated to required gradient and camber as specified. Rolling to be continued till density achieved is at least 98 % of maximum dry density for the laid surface.
M&L for WMM 150 mm thick ( compacted thickeness ) in layers of 75 mm each, using graded crushed stone aggregate of grading (53mm-0.075mm)and granular material premixed with water. Surface to be laid, formed, rolled using smooth wheeled roller of min 80KN weight and consolidated to required gradient and camber as specified. Rolling to be continued till density achieved is at least 98 % of maximum dry density for the laid surface.
M&L for 125 mm thick DLC of grading (26.5mm - 0.075mm) with 7 days compressive strength of 10Mpa with minimum cement content of 180Kg/Cum. Design mix, laying spreading and compaction using vibratory roller of minimum 80 KN weight to required gradient and camber as specified. Rolling to be continued till density achieved is atleast 98 percent of maximum dry density of the laid surface.
M&L for HDPE sheet, 400 micron thick laid and secured oversand cushion
M&L 200 mm thick PQC in pavement/ hardstanding of flexrual strength of 45 kg/sqcm including formwork in field using non circular synthetic fibre as per manufacturer's recommendation complete all as specified (Non Circular fibre rate considered seperately) Note :- K-Value of subgrade is considered 3Kg/Sqcm/cm. Before execution K Value is required to be tested.
M&L for forming 25 mm wide Expansion joint in 200 mm thick concrete pavement and filling with 25 mm thick premoulded high density filler board HD 100 as specified and provn of 30 mm dia polythene back up rod and top 15 mm primed & filled with polyurethene based sealant (backup material) over two coats of approved primer , before 30 minutes to pouring the sealant all as per manufacturers instruction . The concrete surface of the joints shall be made dry and free of dirt and vaccume cleaned by a mechanical device.The joint performance warranty shall be of 10 years.
M&L for forming Dummy joints of 8mm wide and polyurtethene back up rod of 10mm dia and top 15 mm primed & filled with polyurethene based sealant (backup material) over two coats of approved primer , before 30 minutes to pouring the sealant all as per manufacturers instruction . The concrete surface of the joints shall be made dry and free of dirt and vaccume cleaned by a mechanical device.The joint performance warranty shall be of 10 years.
M&L for forming Construction joints of 10mm wide and 25mm depth and polythene back up rod of 12mm dia and top primed & filled with polyurethene based sealant (backup material) over two coat of approved primer , before 30 minutes to pouring the sealant all as per manufacturers instructions. The concrete surface of the joints shall be made dry and free of dirt and vaccume cleaned by a mechanical device.The joint performance warranty shall be of 10 years.
EXTERNAL ELECTRIC SUPPLY: Supply and Installation of 11 KV Compact Sub Station with non extensible RMU consisting of 1 No manually operated 11 KV/630 Amps VCB in SF6 insulated stainless enclosure,HT Cable/Bus bar ,1 No transformer 500 KVA,11KV/433 CRT dry type & associated LT devices(ACB/MCCB/bus bar/Cable)
Supply Install, and commissioning LT feeder pillar Outdoor, type made out of 3.15 mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounting plate, frame and canopy, confirms to IEC61439-2 with following asseccories suitable for incoming/outgoing arrangements:- (a)Incomer - ACB 630 A ,4 pole ,65 kA (b) Outgoings (i) MCCB 4 pole 200 A ,50 KA- 04 Nos (ii) MCCB 4 pole 160 A , 36 KA- 01 No (iii) MCCB 2 pole 32A ,10 KA- 04 Nos (iv) MCCB 4 pole 100 A, 35 KA - 02 Nos (v) Digital panel meter for voltAmp/Volt/KWH&PF, necessary CT - 01 No (vi) LED indicating lamp set- 01 Set of three
Supply Install, and commissioning LT feeder pillar Outdoor, type made out of 3.15mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounting plate, frame and canopy, confirms to IEC61439-2 with following asseccories suitable for incoming/outgoing arrangements:- (a) Incomer :- ACB 800A 4 pole ,50 KA- 01 Nos Outgoings :- (b)ACB 630A 4 pole ,50 KA- 01 Nos (c) MCCB 315 4 pole ,50 KA- 01 Nos (d) MCCB 200A 4 pole ,50 KA- 01 Nos (e) LED indicating lamp set- 01 Set of three (f) Digital panel meter for voltAmp/Volt/KWH&PF, necessary CT - 01 No
Supply Install, and commissioning LT feeder pillar Outdoor, type made out of 3.15 mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounting plate, frame and canopy, confirms to IEC61439-2 with following asseccories suitable for incoming/outgoing arrangements:- (a)Incomer - MCCB 200 A ,4 pole ,50 kA (b) Outgoings (i) MCCB 4 pole 100 A ,50 KA- 02 Nos (ii)MCCB 4 pole 63 A, 25 KA - 02 Nos (iii) MCB DP 32 A - 04 Nos (iv) Digital panel meter for voltAmp/Volt/KWH&PF, necessary CT - 01 No (v) LED indicating lamp set- 01 Set of three
Supply Install, and commissioning LT feeder pillar Outdoor, type made out of 3.15 mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounting plate, frame and canopy, confirms to IEC61439-2 with following asseccories suitable for incoming/outgoing arrangements:- (a)Incomer - MCCB 200 A ,4 pole ,50 kA (b) Outgoings (i) MCCB 4 pole 160 A ,50 KA- 02 Nos (ii)MCCB 4 pole 63 A, 25 KA - 02 Nos (iii) Digital panel meter for voltAmp/Volt/KWH&PF, necessary CT - 01 No (iv) LED indicating lamp set- 01 Set of three (v) Digital time switch and contactor - 01 No
Supply Install, and commissioning LT panel board indoor, type made out of 2 mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounting plate, frame and canopy, confirms to IEC61439-2 with following asseccories suitable for incoming/outgoing arrangements:- (a)Incomer - MCCB 40 A ,4 pole ,50 kA (b) Outgoings (i) MCCB 4 pole 32 A ,16 KA- 03 Nos (ii) DOL Starter 3Hp motor -02 Nos (iii) Digital panel meter for voltAmp/Volt/KWH&PF, necessary CT - 01 No (iv) LED indicating lamp set- 01 Set of three
FIRE FIGHTING: Supply and fix Foot Valve conforming to IS 4038, 150 mm dia
Supply and fix Foot Valve conforming to IS 4038, 100 mm dia
Supply and fix Mild Steel class 'C' diesel pump exhaust pipe 150mm dia with one layer of10mm thick asbestos rope insulation and including all fitting clamp/ structural steel supports complete
Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Cast Iron Water supply mains of size 50 mm dia.
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1100 Volts grade. (a)3 Core, 1.5 Sq mm,
(b) 6 Core, 1.5 Sq mm,
Supply,install testing and commisssioning water cum foam monitor stainless steel base flange, reducer, pipe, swivel joint hand wheel, drain valve, aqua form nozzle, dewep tube with stainer, ball valve, PVC helical pick up tube with hangar NB 100mm nozzle 80mm flow 750 GPM @ 7 bar, rotation horizantal 360°, vertical 125°with painted fire, red colour all as specified and directed.
Supply and fixing S.S Foam Tank Made out of 3mm thick SS 304 plate with required nozzles, stand, level gauge, coupling, jointing materials, etc, with all required accessories of capacity 200 Ltrs and all as specified and directed.
AFFF 3% Foam Concentrate, as per IS:4989, Part-II and all as specified and directed.
Supply, Installation,Testing & commissioning of MECHANICAL FOAM type fire extinguisher of 9 Ltrs confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply, Installation,Testing & commissioning of Trolley Mounted MECHANICAL FOAM type fire extinguisher of 45 Ltrs Kg confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply, Installation,Testing & commissioning of DRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 6 Kg confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply, Installation,Testing & commissioning of Trolley Mounted DRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 25 Kg confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS : 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets.
Supply and installation at approved location approved make Fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & Showel etc, complete.
Supply and fix sided LED signage with built in battery backup for 2 hrs, Make- Bajaj or equivalent, Cat No. BESL 03 LED SSD WBB Red 220209
EXTERNAL WATER SUPPLY: Supply and lay pipe galvanized, “Medium class”, including fittings 63 mm dia.
Supply and fix Foot Valve conforming to IS 4038, 65 mm dia
Supply, install, testing and commissioning of Monoblock pump set 3Hp/2.2KW, 525-275 Lpm 15-24m head with GM impeller, stainless steel shaft, mechanical scale etc including necessary fixing arrangement etc all as specified and directed.
Construction of valve chamber with inner clear dimension 600 x 600 x 900mm suitable for 80mm sluice Valves with PCC (1:4:8) 150mm thick type D2 for foundation, Brick masonary 230mm wall in CM (1:4), PCC (1:2:4) 75mm type B1 for coping, rendering in CM (1:4) 15mm thick including provisiion of 3mm thick MS sheet cover and 25 x 25 x 3mm angle frame embeded in coping with two coats of synthetic enamel paint over a coat of red oxide primer with locking arrangements including necessary earth work complete all as specified and directed by Engr-in-charge
Supply, install, testing and commissioning of active loop repeater panel with inbuilt memory, RS 485 card, 24V DC power supply etc all as specified and directed. Note: Location of panel shall be approved by user
DG SET: Supply & installation testing and commissioning of silent Diesel Engine driven generating set 415 Volts, 3 phase 4 wire, engine as per IS: 10001/ 10002 and alternator as per IS: 13364 complete with foundation, AMF control panel with necessary meters and sound proof canopy and foundation etc.of capacity upto 82.5 KVA. Note: DG Sets has to confirm latest CPCB-II emmission norms and efficiency as per ECBC.
AVIATION OBSTRUCTION LIGHT: Supply and fix aviation obstruction LED type of Bajaj cat No 110731 BGAV 302 LED, 240 V, with timer switch and contactor inside the enclosure
REFRIGERATION & AIR CONDITIONING: Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA
INTERNAL ELECTRIC SUPPLY: Supply and fixing LED lights fitting 34W surface mounting down light , 220V, AC decorative with driver, including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make: Havells Cat part No :PLUTOSURFAC2X2PLS34WLED857S or Euivalant in Phillips/Wipro/Bajaj
Supply and fixing LED Flood Light fitting 200 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with necessary fixing arrangement as shown in drawing.. Make: Havells CAT Part No: JETAVALOURFLL200WLED757OINTWBLTG / Phillips/ Bajaj/Wipro
Supply and fixing LED Exit signage light fitting 3 Watt 230 V AC with 2 hr Battery Back up Make: Bajaj Cat Part No: BESL 03 LED SSD WBB Red/Havells/Wipro/Phillips
Supply and fixing LED Staircase signage light fitting 3 Watt 230 V AC with 2 hr Battery Back up Make: Bajaj Cat Part No: Staircase signage DSDWBB/Havells/Wipro/Phillips
S & F BEE 3 star rated energy efficient BLDC high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a down road of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed.
S & F energy efficient non-metallic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. VENTILUS 10" or equivalent model of Usha, Havells or BAJAJ
S&F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery not less than 900 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No.TRANS AIR 12" or equivalent model of Usha, Havells or BAJAJ
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type LT Panel for Annex I of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides open able with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge.(for Annex buiding)Note: Electrical panells shall be provided with CO2 /clean agent local application system with cylinder located outside the panells (For Annexe Bldg) The Panel shall comprise of the following:
[A] BUSBAR CHAMBER [I] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [I] 200 A, 415 V, Ices = 100% Ice = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ire), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc. [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [iii] Digital Multifunction meter with KWH and Karsh, Voltage, current, PF functions [C] OUTGOING [i] 63 A, 415 V, Ices = 100% Ice = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, Qty 4 Nos(For Each floor+1 spare)
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor cubical compartmental type LT panel Annex II of suitable size, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides open able with hinged double doors and locking arrangement, IP 43 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by engineer-in-charge.(for Adm Blding) The Panel shall comprise of the following:
[A] BUSBAR CHAMBER [I] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [I] 125 A, 415 V, Ices = 100% Ice = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ire), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload), etc. [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [iii] Digital Multifunction meter with KWH and Karsh, Voltage, current, PF functions [C] OUTGOING [i] 40 A, 415 V, Ices = 100% Ice = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, Qty 2 Nos [ii] 32 A, 415 V, Ices = 100% Ice = 50 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, Qty 1 Nos
S & F RCBO conforming to IS 12640 (Part 2): 2016, assembled for AC applications having front face indication for earth leakage fault, sliding shutters, IP 20 protected 35 mm² terminals, colour coded on/off indication on dolly, integrated label holder, etc complete all as specified and directed.
63 A, 100 mA, FP 415V, 50 Hz RCBO
32 A, 30 mA, DP 230V V, 50 Hz RCBO
40 A, 100 mA, FP 415V, 50 Hz RCBO
Supply and fix PVC FRLS cable duct fixed on wall with un slotted type non slip cover including with all accessories including fixing plug, cable tie attachment, wire retainer mounting clamp angle/corner duct, channel ports etc with following size. (FOR COMMUNICATION CABLE)
100mmX50mm
32mmX20mm
32mmX16mm
Supply & fix surface mounted LED batten light fittings 40W with metallic body DMMA diffuser, heavy duty driver THD<10% including connecting up with twin core twisted cable. Make Havells cat No; STOUT PLUS 1200BS 40W LED
INTERNAL WATER SUPPLY: Supply & fixing 15mm dia Two way bib taps (Fancy type), cast copper alloy with crutch or butterfly handle, screwed down,screwed for iron/CPVC pipes complete all as specified.
Supply & fixing of Health faucet with wall hook Make Hindware Model No F160027 or equivalent 15mm dia.
WATER HEATER: Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rated, including fastners/nut bolts complete for fixing arrangement and all as directed by Engr-in-charge.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid