Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L1 | Accepted-AOC BEING LOWEST AND REASONABLE. | |
| 2 | L2₹32.0 L+₹3.1 L (10.7%)Rejected-Finance 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹33.2 L+₹4.4 L (15.1%)Rejected-Finance 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹38.2 L+₹9.4 L (32.4%)Rejected-Finance | L4 | Rejected-Finance Being not lowest |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
26 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE KOLKATA
Headquarter Commander Works Engineers Military Engineer Services No1 National Library Avenue Alipore Kolkata700 027
REPAIR MAINT OF HT NETWORK SYSTEM AND ITS ALLIED WORKS UNDER GE (FW) KOLKATA
2023_MES_605613_1
8277/E-18/23-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(FW) KOLKATA
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE FORT WILLIAM KOLKATA
₹92,000
28 Aug 2023
26 Jun 2023
3 Aug 2023
26 Jun 2023
26 Jul 2023
11 Jul 2023
26 Jun 2023 - 3 Jul 2023
Amount
Excavation in trenches manually without using JCB not exc 1.5m wide and not exceeding 1.5m depth for foundation laying of cables etc and getting out in soft / loose soil complete all as specified and directed.
Returning, filling including spreading, leveling, watering and well ramming in layers n.exc 25cm in soil complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5 mtr above the strating point as in soil complete all as specified and directed.
Disconnecting and Taking down / out unserviceable HT, XLPE cable 6.6 KV of size 70 Sqmm to 300 Sqmm 3 Core of any description from trenches, Floors, walls, GI Pipes etc and seggrating serviceable cables, pipes, bricks etc including keep in safe custody for re-use and removing unserviceable cable complete all as specified and directed by Engineer-in-Charge. Note:- (i) Any damage / punctured into HT cable if takes place during taking down / up shall be responsibility of contractor and damege HT cable will be replaced by contractor by providing new cable of same size without any extra cost. (ii) Before laying meggaring the complete cable in presence of Engineer-in-Charge shall be done. (iii) Necessary earthwork shall be measured and paid separately under appropriate items of this BOQ.
Laying of XLPE under ground cable after rectifying the defects (Serviceable cable obtained from Item No 4 here-in-before) 6600 Volt grade, Cross sectional area 70 Sqmm to 300 Sqmm, 3 Core including Jointing and Testing complete all as specified and directed.
Supply and laying of XLPE insulated (Earthed), screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 6.6 KV grade, cross sectional area 95 Sqmm, 3 Core complete all as specified and directed.
All as per item No 6 here-in-before but cross sectional area 240 Sqmm, 3 Core
All as per item No 6 here-in-before but cross sectional area 300 Sqmm, 3 Core
Supply, Jointing and testing of cable jointing kit for 6.6 KV(Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 70 Sqmm to 120 Sqmm complete all as specified and directed.
All as per item No 9 here-in-before but of size 150 Sqmm to 225 Sqmm
All as per item No 9 here-in-before but of size 240 Sqmm to 400 Sqmm
Supply, Jointing and testing of cable jointing kit for 6.6 KV(Earthed) grade cable for indoor termination heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armored Aluminium conductor cable of size 70 Sqmm to 120 Sqmm complete all as specified and directed.
All as per item No 12 here-in-before but of size 150 Sqmm to 225 Sqmm
All as per item No 12 here-in-before but of size 240 Sqmm to 300 Sqmm
Supply, Jointing and testing of cable jointing kit for 6.6 KV(Earthed) grade cable for straight through heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armored Aluminium conductor cable of size 70 Sqmm to 95 Sqmm complete all as specified and directed.
All as per item No 15 here-in-before but of size 120 Sqmm to 185 Sqmm
All as per item No 15 here-in-before but of size 240 Sqmm to 300 Sqmm
Material and labour for dry river sand as in sand cushioning to under ground cable including punning down complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1, flat of size 300mm x 180mm x 40mm complete all as specified and directed.
Laying only serviceable precast concrete cable cover obtain from item no 4 here-in-before complete all as specified and directed.
Material and labour for making of bore to road link width for providing HDPE Pipe upto 110mm dia for passing armoured cable complete all as specified and directed.
Supply and fixing of HDPE pipe 100mm dia, PE 80 IS: 14333 grade, working pressure 10 KGF / CM2 including taking out old unserviceable one complete all as specified and directed.
Supply and fixing 100mm bore galvanized iron pipe (light grade) with all fittings, fixed complete to wall / ceiling or laid in floor including taking down old unserviceable GI pipe complete all as specified and directed.
Dismantling / Disconnecting electric connection of underground HT, XLPE Cable, 6.6 KV upto 70 to 300 Sqmm from both sides and locating the fault in HT cable upto 01 KM with fault locating machine in the entire length complete testing after reconnecting and commissioning of cable complete all as specified and directed. Note:- The work will be executed after obtaining proper shutdown from main power house as directed by Engineer-in-Charge.
Disconnecting HT/LT connection of transformer and opening up the top cover of transformer of capacity 500 KVA to 750KVA for checking the conditions to carryout repairs and overhauling, including draining out oil from the transformer in suitable container (containers shall be provided by the contractor) and repair to the transformer with replacement of parts (as required), checking the lead connection from winding to bus rods including necessary soldering/jointing etc and after complete repair refilling the dehydrated oil and topping up with new transformer oil, replacing perished gasket with new gasket of same size and testing on full load after connecting the HT/LT connections as per instructions of relevant BIS Code complete all as directed by Engineer-in-Charge. [Note: - The materials used for servicing will be measured and paid under separate item as supply only. All other minor spares/ materials and tools used for servicing not mentioned in the schedule (viz drain plug, bolts and nuts, materials and tools required for cleaning or core/ windings, tools required for cutting of gaskets etc) shall be deemed inclusive in the quoted rate. Dehydration and topping up of transformer oil at the time of servicing will be measured and paid under appropriate item in BOQ]
All as per ser Item No 25 here-in-before but transformer of capacity 315 KVA to 400 KVA
All as per ser Item No 25 here-in-before but transformer of capacity 200 KVA to 250 KVA
All as per ser Item No 25 here-in-before but transformer of capacity 75 KVA to 160 KVA
Supply only in repair HT bushing including gasket suitable for transformer of capacity 500 KVA to 750 KVA as required at site complete all as directed (for three phases)
All as per Item No 29 here-in-before but suitable for transformer of capacity 315 KVA to 400 KVA
All as per Item No 29 here-in-before but suitable for transformer of capacity 200 KVA to 250 KVA
All as per Item No 29 here-in-before but suitable for transformer of capacity 75 KVA to 160 KVA
Supply only LT bushing including gasket suitable for transformer of capacity 500 KVA to 750 KVA as required at site complete all as directed (for three phases & Neutral)
All as per Item No 33 here-in-before but suitable for transformer of capacity 315 KVA to 400 KVA
All as per Item No 33 here-in-before but suitable for transformer of capacity 200 KVA to 250 KVA
All as per Item No 33 here-in-before but suitable for transformer of capacity 75 KVA to 160 KVA
Supply only in repair of breather assembly complete with silica gel for transformers from above 315 KVA upto 750 KVA of any make, type and capacity of make complete all as specified and directed.
Supply only silica gel for transformer of any make, type and capacity or make complete all as specified and directed.
Supply only transformer oil ISI marked in sealed containers for topping up, conforming to IS-335 with dielectric strength of not less than 50 KV and testing for strength including recording results complete all as specified and directed. Note:- (i) Purchase vouchers alongwith manufacturer's test certificate shall be produced by the contractor before payment. (ii) Nos of sealed containers shall be recorded in MB. Make: CASTROL / IOCL(SERVO)/HP.
Material and labour for taking of insulating oil from transformer and check the Acid Test / Di-electric strength of oil with authorised laboratary as per IS:6792:2017 before De-hydration of transformer oil of any capacity of transformer complete all as specified and directed.
De-hydration and filtration of transformer oil by using dehydration and filtration plant, heating and filtration of oil to be carried out till the di-electric strength reaches 50 KV to 60 KV withstand for one minute is achieved for any capacity of transformer complete all as specified and directed.
Material and labour for MS Cross arms, bracings, supports etc. incl nuts, bolts, washers, welding, bending, drilling inclusive of two coats of aluminium paint over a coat of red oxide primer after preparation of surface including taking down old steel members complete all as specified and directed.
S&F of Cable Route indicator made out of Cast Iron plate 80mm dia fixed with MS angle iron 40x40x6mm having 60cm long showing MES HT cable size with voltage with two coats of synthetic enamel paint in brown colour over one coat of primer necessary Earth work and cement concrete 1:2:4 (20 mm crushed stone aggregate) Block of size 20cm x 20cm x 20cm including taking down old unserviceable cable route indicator complete all as specified and directed.
Dismantling old unserviceable gang operated Air breaker switch from two pole / four pole structure and Supply & fixing gang operated air breaker switch, triple pole, mechanically operated, mounted on insulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe, for current rating 200 Amps, out door type(conforming to IS specifications) HT 6.6 KV, triple pole with fixed contacts of phosphorus and bronze and a set of drop out HT fuse Assembly, Fuse carrier fitting, 9 insulator type mounted on MS channel operating rod with pad lock arrangement complete all as specified and directed
Material and labour for lightening arrestors HT expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amp of rating 6.6KV including taking down old unserviceable lightening arrestors complete all as specified and as directed.
All as per item no 45 here-in-before but for lightening arrestors of rating 33 KV
Callibration of microprocessor E/F and O/C relay of VCB complete and calibrating with portable relay test kit to set time and fault level and adjustment of setting with according to load & time with CESC for proper functioning complete all as specified and directed. Note:- Work shall be carried out all as per instruction of existing OEM and approval of GE.
S&F of Multi Function Meter LCD Display with Parameters - Amp, Volt, Freq, PF, RPM, % Load, % Unbal, Amp Phase angle, Maximum Demand including taking down / out unserviceable Multi Function Meter complete all as specified and as directed. Note:- Work shall be carried out all as per instruction of existing OEM and approval of GE.
S&F of bakelite kitkat with 2 / 5/ 10 Amps HRC fuse suitable for Vacuum Circuit Breaker 6.6 KV of capacity 400 / 630 / 800 Amps complete all as specified and as directed as in repair. Note:- Work shall be carried out all as per instruction of existing OEM and approval of GE.
S&F of indicator lamp LED 110 Volt AC with holder (R/Y/B in colour) suitable for Vacuum Circuit Breaker 6.6 KV of capacity 400 / 630 / 800 Amps complete all as specified and as directed as in repair. Note:- Work shall be carried out all as per instruction of existing OEM and approval of GE.
S&F of indicator lamp LED 24 Volt DC with holder (R/Y/B in colour) suitable for Vacuum Circuit Breaker 6.6 KV of capacity 400 / 630 / 800 Amps complete all as specified and as directed as in repair. Note:- Work shall be carried out all as per instruction of existing OEM and approval of GE.
S&F of Power Pack 110 V AC/110 V DC on VCB Panel as per site requirement complete all as specified and as directed as in repair. Note:- Work shall be carried out all as per instruction of existing OEM and approval of GE.
Repair / Maintenance of VCB 6.6 KV capacity by removing of trolly from VCB and checking mechanism system including dusting / cleaning by smooth brushing or dry cottopn and lubrication of moving mechanism system with suitable oil / grease including necessary inspection, ressembling, checking etc complete for smooth functioning of the equipments all as specified and directed.
Material and labour for repair and overhauling of 6.6 KV capacity VCBs of Sub Stn No 1 with dusting / cleaning by smooth brushing or dry cotton and lubricating of moving mechanism suitable with oil / grease and replacement of unserviceable / burnt out / worn out spare parts with new one as per existing make, duly commissioned in the VCBs at 6.6 KV bulk receiving centre including necessary inspection, reassembling, testing, re-commissioning etc complete for smooth functioning of the equipments to ensure desired result including taking down / dismantling of existing unserviceable spare parts of VCB complete all as instructed by authorised rep of OEM and directed by Engineer-in-Charge. Necessary replacement of following spare parts shall be deemed inclusive in unit quoed rate:- (i) Repair / replacement of vaccum interrupter bottle (03 Nos) for vaccum circuite breaker of 400 Amps in HT panel 6.6 KV grade complete all as specified and directed. (ii) Repair / replacement of Over Voltage and Over Current Closing Coil (01 Nos) suitable for Vaccum Circuit Breaker 6.6 KV of capacity 400 Amps complete all as specified and directed Note:- (i) Cost of spare parts which are needed to be replaced during maintenance work shall be deemed inclusive in quoted rate. (ii) After servicing of VCB, Health check up reports shall be submitted by the contractor. (iii) The old retrieved materials shall be deposited to MES store yard of AGE E/M-1]
Repair and overhauling of 6.6 KV capacity VCBs of Sub Stn No 4 with dusting / cleaning by smooth brushing or dry cotton and lubricating of moving mechanism suitable with oil / grease and replacement of unserviceable / burnt out / worn out spare parts with new one as per existing make, duly commissioned in the VCBs at 6.6 KV bulk receiving centre including necessary inspection, reassembling, testing, re-commissioning etc complete for smooth functioning of the equipments to ensure desired result including taking down / dismantling of existing unserviceable spare parts of VCB complete all as instructed by authorised rep of OEM and directed by Engineer-in-Charge. Necessary replacement of following spare parts shall be deemed inclusive in unit quoed rate:- (i) Replacement of CTs (03 Nos) with ratio 400/200/100/50/5 Amps suitable for Vaccum Circuit Breaker 6.6 KV of capacity 400 Amps including internal wiring from CTs to Ammeter and testing after completion of Job complete all as specified and directed. Note:- (i) Cost of spare parts which are needed to be replaced during maintenance work shall be deemed inclusive in quoted rate. (ii) After servicing of VCB, Health check up reports shall be submitted by the contractor. (iii) The old retrieved materials shall be deposited to MES store yard of AGE E/M-1]
Repair and overhauling of 6.6 KV capacity VCBs of Sub Stn No 2 with dusting / cleaning by smooth brushing or dry cotton and lubricating of moving mechanism suitable with oil / grease and replacement of unserviceable / burnt out / worn out spare parts with new one as per existing make, duly commissioned in the VCBs at 6.6 KV bulk receiving centre including necessary inspection, reassembling, testing, re-commissioning etc complete for smooth functioning of the equipments to ensure desired result including taking down / dismantling of existing unserviceable spare parts of VCB complete all as instructed by authorised rep of OEM and directed by Engineer-in-Charge. Necessary replacement of following spare parts shall be deemed inclusive in unit quoed rate:- (i) Replacement of PTs (03 Nos) with ratio 400/200/100/50/5 Amps suitable for Vaccum Circuit Breaker 6.6 KV of capacity 400 Amps including internal wiring from CTs to Ammeter and testing after completion of Job complete all as specified and directed. (ii) Replacement of Power Pack 110 volt AC / DC (01 Nos) suitable for VCB 6.6 KV of capacity 400 Amps complete all as specified and directed. Note:- (i) Cost of spare parts which are needed to be replaced during maintenance work shall be deemed inclusive in quoted rate. (ii) After servicing of VCB, Health check up reports shall be submitted by the contractor. (iii) The old retrieved materials shall be deposited to MES store yard of AGE E/M-1]
Repair and overhauling of 6.6 KV capacity VCBs of Main Power House with dusting / cleaning by smooth brushing or dry cotton and lubricating of moving mechanism suitable with oil / grease and replacement of unserviceable / burnt out / worn out spare parts with new one as per existing make, duly commissioned in the VCBs at 6.6 KV bulk receiving centre including necessary inspection, reassembling, testing, re-commissioning etc complete for smooth functioning of the equipments to ensure desired result including taking down / dismantling of existing unserviceable spare parts of VCB complete all as instructed by authorised rep of OEM and directed by Engineer-in-Charge. Necessary replacement of following spare parts shall be deemed inclusive in unit quoed rate:- (i) Replacement of PTs (03 Nos) with ratio 400/200/100/50/5 Amps suitable for Vaccum Circuit Breaker 6.6 KV of capacity 400 Amps including internal wiring from CTs to Ammeter and testing after completion of Job complete all as specified and directed. Note:- (i) Cost of spare parts which are needed to be replaced during maintenance work shall be deemed inclusive in quoted rate. (ii) After servicing of VCB, Health check up reports shall be submitted by the contractor. (iii) The old retrieved materials shall be deposited to MES store yard of AGE E/M-1]
Material and labour for preparation of old painted steel or iron surfaces of VCB Panel of any capacity by scrapping with steel wire brush/scrapper emery paper, etc. and applying one coats of synthetic enamel smoke grey paint (painting shall be done by spray machine) including writing of SM No, MES No etc. with approved colour synthetic enamel thick paint in white back ground complete all as specified and directed
Supply and laying of 2.5 mm thick insulated synthetic mat of confirming to IS 15652 : 2006 and meeting the requirement of IS 5216 (Part 1, 2 & 3) IS 8437, IFC - 479 Pub-1, alongwith suitable adhesive / chemibound, PU resin, water proofing compound and sealing materials as per in service recommendation of IS : 15652 class - B suitable for working voltage upto 6.6 / 11 KV with trolley movement complete all as specified and directed.
Material and labour in repair for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below the normal ground level, connected with and including galvanized earth strip of size 32 x 6mm thick connected to main test point as directed as earthing lead by means of nuts, bolts, washers of galvanized iron protected by 40mm dia (light grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (medium grade) watering pipe including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350 x 350 x 50mm reinforced with 8mm dia TMT bars @15 cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternative layers including necessary excavation and earth work in soft/ loose soil all as shown in Electric Plate No. 3 of SSR Part - I and testing including taking down old earthing complete all as specified and directed.
Supply and fixing earth continuity conductor or main earthing galvanised iron strip of size 32 x 6 mm fixed to VCB / Transformer / RMU etc complete all as specified and directed.
Ultimate Solution Company
INDIA ELECTRICAL EQUIPMENTS
TOTCO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .