Loading…
Loading…
Tender Value
₹2.0 Cr
EMD Value
₹4.0 L
Closing Date
17 Aug 2026, 11:00 am
Hosadurga road: Construction of Type-II 8 units staff quarters
25MYS26of24-07-26itno03
25MYS26of24-07-26itno03
Open
Works - General
12 Months
Ramanagara, Karnataka
₹0
₹4.0 L
24 Jul 2026
24 Jul 2026
3 Aug 2026
A-List of items that are covered under DSR
B-List of items that are not covered under DSR
A1-List of items that are covered under DSR
Item Breakup - A-List of items that are covered under DSR
88 mm, weighing not less than 170 gms 18.0 WATER SUPPLY 18.7S C.P.V.C. PIPES Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 18.7 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. ( Internal work - Exposed on wall ) 78 18.7.2 20 mm nominal dia Pipes Metre 80 335 26800 79 18.7.3 25 mm nominal dia Pipes Metre 100 401.55 40155 80 18.7.5 40 mm nominal dia Pipes Metre 110 702.95 77324.5 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & 18.8 fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 81 18.8.2 20 mm nominal dia Pipes Metre 90 537.6 48384 MYSORE DIVISION-ENGINEERING/SOUTH WESTERN RLY Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This 18.9 includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 82 18.9.5 40 mm nominal dia Pipes Metre 184 563.05 103601.2 18.15S BRASS FITTINGS Providing and fixing gun metal gate valve 18.17 with C.I. wheel of approved quality (screwed end) : 83 18.17.1 25 mm nominal bore Each 16 622.4 9958.4 84 18.17.3 40 mm nominal bore Each 3 826.1 2478.3 Providing and fixing ball valve (brass) of 18.18 approved quality, High or low pressure, with plastic floats complete : 85 18.18.3 25 mm nominal bore Each 16 464.05 7424.8 C.I. SLUICE VALVES/ FIRE HYDRANTS & 18.31S FIXTURES Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and 18.46 making long screws etc. complete (New work) : 86 18.46.3 25 mm nominal bore Each 16 439.25 7028 87 18.46.5 40 mm nominal bore Each 3 631.3 1893.9 18.48 Providing and placing on terrace (at all floor Per 8000 11 88000 levels) polyethylene water storage tank, IS : Litre 12701 marked, with cover and suitable 88 locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 18.49S C.P. BRASS FITTINGS Providing and fixing C.P. brass bib cock of 18.49 approved quality conforming to IS:8931 : 89 18.49.1 15 mm nominal bore Each 24 506.8 12163.2 Providing and fixing C.P. brass angle valve for 18.53 basin mixer and geyser points of approved quality conforming to IS:8931 90 18.53.1 15mm nominal bore Each 8 574.3 4594.4 18.59S AIR VALVE & WATER METER (BULK TYPE) 18.65 Providing and fixing PTMT soap Dish Holder Each 8 111.45 891.6 having length of 138mm, breadth 102mm, 91 height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 19.0 DRAINAGE 19.1S STONE WARE PIPES AND FITTINGS Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. 19.4 cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 19.4.1 100x100 mm size P type 19.4.1.1 With common burnt clay F.P.S. (non modular) Each 16 2707.65 43322.4 92 bricks of class designation 7.5 MYSORE DIVISION-ENGINEERING/SOUTH WESTERN RLY Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed 19.6 with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 93 19.6.1 100 mm dia. R.C.C. pipe Metre 30 507.05 15211.5 94 19.6.2 150 mm dia. R.C.C. pipe Metre 40 556.45 22258 95 19.6.3 250 mm dia. R.C.C. pipe Metre 50 899.8 44990 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation 19.9 concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement 19.9.1 concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 19.9.1.1 With common burnt clay F.P.S. (non modular) Each 3 12725 38175 96 bricks of class designation 7.5 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 19.30 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm 19.30.1 deep for single pipe line : 19.30.1.1 With common burnt clay F.P.S. (non modular) Each 12 6937.9 83254.8 97 bricks of class designation 7.5 22.0 WATER PROOFING 22.1S General MYSORE DIVISION-ENGINEERING/SOUTH WESTERN RLY 22.3 Providing and laying water proofing Sqm 80 769.6 61568 treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS: 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm 98 cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at1.7 kg. per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @1.7 kg/sqm). 22.6 Providing and laying water proofing Sqm 400 688.9 275560 treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than10 cm. (c) third layer of 1.5 mm thickness 99 consisting of slurry of cement @1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. Grading roof for water proofing treatment 22.14 with 22.14.1 Cement concrete 1:2:4 (1 cement : 2 coarse cum 15 8042.3 120634.5 100 sand : 4 graded stone aggregate 20 mm nominal size) 26.0 NEW TECHNOLOGIES AND MATERIALS 26.73S PREFAB/PRECAST TECHNOLOGY MYSORE DIVISION-ENGINEERING/SOUTH WESTERN RLY Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 26.86 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). 101 26.86.1 Frame size 45 x 70 mm Metre 82 705.85 57879.7 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white color and other side of board laminted with PVC foil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/kitchen cabinet etc. of required sizes comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index 26.89 of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. 102 26.89.2 25 mm thick Sqm 28 3889.15 108896.2 Total 23726297.35
Item Breakup - A1-List of items that are covered under DSR
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
HSDQRS.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo5.pdf Correction Slip No 5 to GCC 2022
ATTACHMENT
IRGCCApril2022.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo6.pdf Correction Slip No 6 to GCC 2022
ATTACHMENT
GCCACSCORRECTION.pdf
ATTACHMENT
ACS-3toGCC-2022.pdf
ATTACHMENT
JPOforcablecut.pdf
ATTACHMENT
Proforma161718.pdf
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo9.pdf Correction Slip No 9 to GCC 2022
ATTACHMENT
GCCAdvanceCorrectionSlipNo7.pdf Correction Slip No 7 to GCC 2022
ATTACHMENT
GCCAdvanceCorrectionSlipNo10.pdf Correction Slip No 10 to GCC 2022
ATTACHMENT
GCCAdvanceCorrectionSlipNo8.pdf Correction Slip No 8 to GCC 2022
ATTACHMENT
Correction slip to GCC 2022
ATTACHMENT
ACS-4toGCC-2022.pdf
ATTACHMENT
ACS-2toGCC-2022_2022-CE-1-CT-GCC-2022.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo5.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo6.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo9.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo7.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo10.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo8.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].