Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC AT BALANTAR POST PATHARA VIA KHALLIKOTE DIST GANJAM ORISSA 761029 | GANJAM | ODISHA | 761029 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.1 L+₹1.6 L (6.45%)Rejected-Finance AT AMRITPUR PO NB CHILKA VIA BALUGAON DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L2 | Rejected-Finance Other than L1. | |
| 3 | L3₹28.4 L+₹3.9 L (16.0%)Rejected-Finance AT AMRITPUR PO INS CHILKA DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹22.8 L
EMD Value
₹45,600
Closing Date
5 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINNER CHILKA
GE CHILKA ODISHA-752037
PROVISION OF RELIGIOUS INSTITUTE HALL AT INS CHILKA UNDER GE CHILKA
2023_MES_617614_1
GE/CHL/8818 OF 2023-24
Open Tender
Civil Works
Works
180 days
GARRISON ENGINNER CHILKA
MES Enlisted contractor of Class E Category a i
7 documents required · 7 mandatory
₹500
Yes
GE CHILKA
₹45,600
Yes
27 Oct 2023
7 Sept 2023
7 Oct 2023
7 Sept 2023
5 Oct 2023
16 Sept 2023
8 Sept 2023 - 14 Sept 2023
Amount
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil etc all as specified.
Excavating in trenches n.exc. 1.50m wide and n.exc. 1.50m in depth for foundation etc and getting out in any type of soil etc all completed.
M & L for plain cement concrete, type D-2 , 1:4:8 using 40mm graded stone aggregate as in foundations,filling and mass concrete etc all completed
Returnig filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm of soft/loose soil etc all complete.
Removing excavated surplus soil, n.exc. 50.0 m and depositing where directed at a level n.exc. 1.50m above the starting point etc all complete
Filling under floors or pavings with available soil, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc complete all as specified and directed.
Supply & Filling Moorum under floors or pavings with available soil, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering etc complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft beams, sides and soffits if any of foundation and plinth beams and similar works vertical or to batter of flat rough finished etc all complete.
M&L for RCC , M-30 (Design Mix) using 20mm graded stone aggregate as in Foundations, including rafts, footing foundation beams plinth beams ; bases for coumns, etc basement slabs under reamed piles and mass concrete complete all as specified and as directed.
Formwork to sides of pillars , posts, struts, piers, columns and stanchions of square, rectangular or polygonal of rough finished etc all complete
M&L for RCC , M-30 (Design Mix) using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
M & L for formwork to sides and soffits of floor or roof beam, beam hauchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams, etc of flat concrete surfaces fair finished
M & L for RCC M-30 Design mix (20 mm graded aggregates) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick of flat concrete surfaces fair finished.
M & L for RCC M-30 Design mix (20 mm graded aggregates)Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M & L for Formwork to chullah hoods, chajjas, troughs and similar items including edge of flat concrete surfaces fair finished
M & L for RCC M-30 Design mix (20 mm graded aggregates) Chajjas complete all as specified and as directed.
S&F TMT bar as in reinforcement 10mm dia and over cut to length, bent to shape required including cranking, bending spirally, hooking ends and binding with and including mild steel with (annealed) not less than 0.9mm dia.
Ditto all as per above item but 5mm dia and above TMT bar as in stirrups, spaces, binders nibs etc.
S&F TMT bar as in reinforcement 6 mm dia to 8mm , cut to length, bent to shape required, including cranking, bending hooking ends and binding with and including M.S wire annealed not less than 0.9 mm dia all as specified and directed.
M & L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified & directed by Engr-in-Charge.
M& L for Materials and Labour for rendering 15 mm thick in two layers (10 + 5 mm) with cement mortar (1:4) and top layer of 5 mm thick mixed with water proofing compound as per manufacturer's instruction on fair faces of brick work or concrete surface in walls, complete all as specified and directed. (Note: - Water proofing compound will be measured and paid separately)
M& L for rendering 10 mm thick cement plaster in cement mortar (1:6) on fair faces of brickwork or concrete surfaces in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 5 mm thick plaster in CM 1:3 on ceiling , surface finished even & fair with out using extra cement complete all as specified and as directed.
Supply only Integral water proofing compound.
M & L for 75 mm thick plain cement concrete (1:4:8) type D2 using 40 mm graded aggregate as in sub base in floor, complete all as specified and directed.
M & L for PCC type B-1 1:2:4, using 20mm graded stone aggregate as in cills, copings, bed plate, kerbs, lintel upto 1.5m spain and other similar bands complete all as specified and as directed.
M&L for coloured vitrified tiles 9 to 10mm thick (square/rectangular)area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles fixed over and including 15mm screed bed in CM 1:4 complete all as specified and directed.
S&F coloured vitrified tiles 9 to 10mm thick (square/rectangular)area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm inskirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles fixed over and including 10mm backing coat in CM 1:4 complete all as specified and directed.
S&F Glazed ceramic tiles in vertical surface 350x 450x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles fixed over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed.
M&L for 18 to 20mm thick mirror polished kota stone as in tread etc. set and jointed in neat cement slurry and pointed in coloured cement to match the colour of stone fixed over and including 20mm screed bed in CM 1:4 complete all as specified and directed.
M&L for 18 to 20mm thick mirror polished kota stone as in risers etc. set and jointed in neat cement slurry and pointed in coloured cement to match the colour of stone fixed over and including 10mm backing coat in CM 1:4 complete all as specified and directed.
M&L for Granite tiles 20mm thick machine cut,beded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
M&L for two coats of weather proof acrylic emulsion (Anti dust) paint exterior grade(100% acrylic) over a coat of primer including preparation of newly plastered external surfaces of walls of any description over 10cm width or girth etc on column/pillars, RCC chhajja and facia etc complete all as specified and as directed.
M&L for applying two coats of oil bound distemper over a coat of alkali resistant primer including preperation of newly plastered surface of wall and 1mm thick wall care putty complete all as specified and as directed.
M&L for applying three coats of white wash including preperation of newly plastered surface of ceiling complete all as specified and as directed.
Preparation of new wooden surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
M & L for 50 mm thick plain cement concrete (1:3:6) type C1 using 20 mm graded aggregate as in Plinth protection, complete all as specified and directed.
M&L for hard core of gauge not.exc 63mm of broken stone or boulder, deposited spread and leveled in layers not exc 15cm thick watered and rammed to a true surface complete all as specified and as directed
S&F 2nd class hardwood plain, solid straight chowkats and frame rebated on the solid, rounded or chamfered, put together with glue pinned at joints etc complete as specified size of frame 125x60mm filled with PCC 1:3:6 typeC-0 all as specified and directed
S&F 30mm thick flush shutters, solid core construction with block board core construction with block board core and plywood face panells commercial type on both faces incl 1mm thich decorative lamination on both faces and 6mm thick 1st class HW (Teak wood) beading all around on edges complete all as specified and directed.
S & F 35mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing lain,chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats as specified and directed by engr in charge .
Supply and fix, 125 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed, complete all as specified and directed.
Supply and fix, 125 mm long Aluminium anodised, handles of extruded section, fabricated type and fixed, complete all as specified and directed.
Supply and Fix, Aluminium Alloy, anodised, sliding door bolt, length of bolt 250 mm, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.
S&F wash hand basin vitreous china white flat back of size 580 X 450mm with brackets, complete including 15 mm bore fancy pillar tap CP complete all as specified and as directed.
S&F PVC connections 15mm size with PTMT nuts and washers for 600mm long pipe complete all as specified and directed.
S&F fancy type CP 15 mm dia bore of pipe angle stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all specified and as directed.
S&F 40 mm outer diameter of 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.
S&F 20 mm outer diameter of 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.
S&F 500 ltr capacity Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including provision of inlet, outlet overflow and wash out connections complete all as specified and as directed.
S&F 25 mm dia bore of pipe Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 25mm-455gms) complete all as specified and as directed.
S&F 32 mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end used for WHB complete all specified and as directed.
S&F 32 mm dia size PVC waste pipe with cup washers complete all as specified and as directed.
S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed.
S&F brass CP tubular towal rail 20mm dia , D type, 600mm long between flanges complete all specified and as directed.
S&F 25mm dia gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe as specified complete all as specified.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and aking curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement
S&F powder coated (Minimum 50 Micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F powder coated (Minimum 50 Micron) aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified
S&F anodised aluminium powder coated (Minimum 50 Micron) door shutters aluminium section weighing 0.55 kg/m including necessry joining cleats,glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges anodised aluminium snap beading screw etc.complete all as specified.
S&F powder coated aluminium Deco grill of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge.
M&L for 4.8mm thick sheet glass, ordinary quality and glazing with aluminium clips in square n exc 0.5 sq. m in each pane
M&L for Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture1.40mm and fixed with stainless steel wire staples or aluminium tube all as specified and directed.
M & L for Treating the backfill in contact with foundation and concrete surface at the rate of 7.5 litres of emulsion per square metre of vertical surface complete all as specified and directed.
M & L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface, complete all as specified and directed.
M & L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area, complete all as specified and directed.
M & L for Treating the soil along with external perimeter of building at the rate of 2.25 litres of emulsion per metre of perimeter wall complete all as specified and directed.
M&L for 10 mm thick cement screed or bedding layer in cement mortar 1:4 on concrete or bricks surface finished even and smooth without using extra cement to receive roof treatment, mixed with water proofing compound @2% by weight of cement , complete all as specified and as directed by Engr-in-Charge. Note - Water proofing compound shall be measured and paid separately.
M&L for water proofing roof treatment, consists of a five layered Atactic polypropylene modified polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.0 Kg/sqm, reinforced with polyster non woven fabric matt (weight not less than 150 gm/sqm), laid with LPG torch forced application over roof surface, with a side & end overlaps of minimum 100 mm, with and including priming the surface with a coat of hot blown bitumen of grade 85/25 @ 1.2 kg/Sqm each at top and bottom of the membrane as bonding material, and a coat of bituminous aluminium primer @ 100 gm/Sqm on top, including sealing all joints by thermo fusion, complete all as per manufacturer's instructions.
S&F curtain rod 25mm dia Powder coated aluminium alloy with fancy type brackets complete all as specified.
Excavating over areas,n. exc 1.5m deep and getting out in any type of soil etc all complete.
M&L 75mm thick PCC type B-1, 1:2:4 (using 20mm graded aggregate) as in floors complete all as specified and directed.
M&L forming constrution joint 30mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as specified.
M&L for 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces incl finished surface even and smooth finishing without using extra cement complete all as specified .
M&L for cement concrete type C1 1:3:6 using 20 mm graded aggregate as in coping complete all as specified.
M&L for cement concrete type B1 1:2:4 using 20 mm graded stone aggrigate as in surface channels and drains complete all as specified.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.complete all as specified.
Ditto all as per above item but add for each 25 mm girth or part thereof over or under 30 cm.
M&L for point wiring with 1.5sqmm PVC insulated unsheathed multistranded copper cable of FRLS grade with one run of 1.5sqmm PVC insulated copper cable as earth continuity drawn in concealed PVC Conduit not less than 20mm dia including pressed steel concealed modular MS box duly covered with modular plate for mounting switches/Sockets, accessories such as spacers, saddles, junction boxes for one light /5 amp socket controlled by one switch.
Ditto all as per above item one socket outlet, three pin, 5/6 Amp on the same board with other switches
Ditto all same as per above item but with 2.5 sqmm PVC insulated unsheathed multistranded copper FRLS grade cable with one run of 2.5 sqmm PVC insulated copper cable as earth continuity for power socket on independent board.
Supply and fixing of switch paino, flush type, single pole, one way, 5/6 Amp, complete all as specified.
Supply and fixing switch socket combination 2 in 1, 5 Amps flush type, 230V, complete all as specified.
Supply and fixing switch socket combination 5 in 1, 5/15 Amps, 230V, complete all as specified.
S&F ceiling rose surface backlite 3 terminals 65X50mm 230V including PVC Box of size 3"X3" round type.
S&F five stepped electronic socket type fan regulator as per site requirement to use in wiring 300 watt
M&L for sub main wiring with 2 runs of 6 sqmm PVC insulated unsehathed copper cable multistand 1100 V of FRLS grade with drawn in and including concealed PVC conduit not less than 25mm dia and one run of PVC insulated serviceable of 6sqmm as earth continuity conductor drawn in PVC conduit with accessories complete NOTE: 3 runs of 6 Sqmm and 1 run of conduit will be measured as one unit i.e RM
Supply and fix 1X18 Watt indoor type retrofit batten type luminaries complete with LED retrofit T8 polycarbonate tube of capacity 18 Watt with decorative holder and including connecting up with three core twisted flexible copper conductor cable with suitable size up to ceiling rose complete all as specified and as directed. Make : (i) Havells Cat Part No.REGALBATTENT8UPTO1X22WDSBSWH (Batten) and PHOTONULTRA+1213T8SSTL20WLED865SPC(LED Lamp) (ii) Wipro Cat Part No.W10921208 (Batten / Channel ) & LL13-181-65SE(LED Lamp) (iii) Bajaj cat part No for Batten :BLRB-DB118 &Tube : BLRB 18W CW / Philips Cat Part No.BN550WLED20-3000 as approved.H or equvalent to philips//CG/Surya roshini
Supply and fixing LED street light 25W, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-charge. Make: Bajaj/ Wipro/ Havells
Supply and fix of Ceiling fan white/Ivory in colour of 1200mm sweep BEE 5 star rating with all fittings complete all as specified and as directed. Make : Havells/Khaitan/Crompton Greaves/Usha
Supply & fix MCB DB 4 way TPN with 200 A rated bus bar,415 Volts, Double door complete. Make-L&T/Schneider/Legrand
Supply & fix MCB DB 4 way SPN with 200 A rated bus bar,240 Volts, Double door complete. Make-L&T/Schneider/Legrand
Supply & Fix MCB TPN 63 Amps 415 volt 50 Hz C series complete all as specified. Make-L&T/Schneider/Legrand
Supply & fix MCB SP 6 to 32 Amps rating 240 Volts, 10 KA, C curve. Complete with connection testing and commissioning. Make-L&T/Schneider/Legrand
Supply & fix 40 Amps SPN C Series MCB 240 Volts.10 KA, Complete with connection testing and commissioning. Make-L&T/Schneider/Legrand
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less than 1.5 M below ground level connected with galvanised earth wire 4 mm dia by means of bolts nuts check nuts and washers of galvanised iron to earth test point all as specified or indicated including necessary excavation and earth work any type of soil PCC (1:3:6) watering funnel, GI tubing 20 mm for watering all as specified and directed and all as shown in electrical plate No.5 of SSR part 1.
Supply and laid in trenches/walls steel water tubes galvanized medium grade complete including fittings of size 20 mm dia.
Supply and fix gun metal globe/gate valve with iron wheel head, screwed both ends for iron pipe of size 20 mm dia all as specified and directed
Cutting or screwing existing pipe of any insertion of tee of suitable size for branch connection dia complete all as specified and directed.
Material and labour for natural river sand as cushioning of cables, including spreading and punning down all as per clause No. 19.75 of SSR part-I complete all as specified and directed by Engineer in charge. Note : punned thickness shall be measured for payment purpose
Supply and lay well burnt/Fly ash brick of size 200x100x80mm locallly available as protection of cable in trenches complete all as specifed and as directed by Engineer in charge
Supply, laying and fixing testing of XLPE under ground cable of size 16 Sqmm 4 core, 1100 volt grade, insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor including connection with lugs, gland etc. complete all as specified and as directed. make : Polycab/Havells/Nicco/Gloster/Finolex
M& L for 40 mm dia GI pipe Light grade galvanised including fittings for cable protection and sealing both end after laying of U/G Cable completed all as specified and directed by engr in charge
D RAVICHANDRAN
VAIKUNTHA PARIDA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .